首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
High‐resolution capillary zone electrophoresis is used to distinguish transferrin glycoforms present in human serum, cerebrospinal fluid, and serum treated with neuraminidase and N‐glycosidase F. The obtained data are compared to mass spectrometry data from the literature. The main focus is on the analysis of the various asialo‐transferrin, monosialo‐transferrin, and disialo‐transferrin molecules found in these samples. The features of capillary zone electrophoresis and mass spectrometry are reviewed and highlighted in the context of the analysis of undersialylated and hypoglycosylated transferrin molecules. High‐resolution capillary zone electrophoresis represents an effective tool to assess the diversity of transferrin patterns whereas mass spectrometry is the method of choice to elucidate structural identification about the glycoforms. Hypoglycosylated transferrin glycoforms present in sera of alcohol abusers and normal subjects are structurally identical to those in sera of patients with a congenital disorder of glycosylation type I. Asialo‐transferrin, monosialo‐transferrin and disialo‐transferrin observed in sera of patients with a type II congenital disorder of glycosylation or a hemolytic uremic syndrome, in cerebrospinal fluid and after treatment of serum with neuraminidase are undersialylated transferrin glycoforms with two N‐glycans of varying structure. Undersialylated disialo‐transferrin is also observed in sera with high levels of trisialo‐transferrin.  相似文献   

2.
Human transferrin (Tf) is a model glycoprotein for congenital disorders of glycosylation (CDG) diagnosis. In the last few years, new CE-UV methods for intact Tf glycoforms analysis have been developed using nonvolatile BGEs and organic modifiers. However, the use of these BGEs does not allow the coupling of these procedures with electrospray MS (ESI-MS). In this study, a new CE-UV separation method of Tf glycoforms is developed, using a double-layer stable coating and a volatile BGE based on ammonium acetate. The separation method is optimized using standard Tf and their potential is demonstrated applying the method to the analysis of sera Tf from healthy individuals and CDG patients. The CE-UV separation method has been coupled to ESI-MS detection. Main parameters such as sheath liquid composition are optimized in order to obtain a good sensitivity. The CE-ESI-MS method has also been used in serum samples obtaining the separation of the different proteins present in serum and partial separation of Tf glycoforms. Different mass spectra and deconvoluted molecular masses were obtained for each sialoform, allowing unequivocal glycoform identification.  相似文献   

3.
分别用乙二胺、二乙胺、三乙胺将自制的以甲基丙烯酸缩水甘油酯(GMA)为单体、乙二醇二甲基丙烯酸酯(EDMA)为交联剂的整体柱修饰为弱、强阴离子交换整体柱。考察了该整体柱的性能,选择出分离蛋白质(牛血清白蛋白、溶菌酶和谷胱甘肽)的最佳实验条件,并在最佳分离条件下考察了这些蛋白质在整体柱上的色谱行为和该整体柱对纤维素降解酶的分离纯化情况。实验结果表明,该整体柱性能良好,可以实现对纤维素降解酶的快速分离与纯化。同时,实验也证明采用梯度洗脱可以实现对某些蛋白质的分离纯化。  相似文献   

4.
An on-line two-stage column chromatographic technique is described which combines reversed-phase and anion-exchange chromatography for the separation of purine nucleic acid components. The elution program applied, consisting of two gradient programmes, provides a separation of bases and nucleosides on the octadecyl silica column and a separation of the nucleotides on the anion-exchange column to which they have been switched at the beginning of the elution. This method is easy to modify for special problems and can be used when establishing a complete profile of purines.  相似文献   

5.
洪广峰  高明霞  晏国全  关霞  陶芊  张祥民 《色谱》2010,28(2):158-162
为了构建高效的离子交换/反相二维液相色谱(IEC/RPLC)分离平台系统,提高复杂蛋白质样品的分离效率,对色谱柱进行了评价与筛选。通过对实际人肝蛋白质样品的分离效果的比较,选择确定了TSKgel DEAE-5PW弱阴离子交换色谱柱(WAX)作为第一维色谱分离柱;考察了同一规格的10支代表性反相色谱柱(250 mm×4.6 mm, 5 μm, 30 nm, C4、C8或C18),通过评价其对尿嘧啶、硝基苯、萘和芴的分离性能以及对3种标准蛋白质样品的非特异性吸附、对人肝蛋白质样品的WAX馏分的分离效果,最终确定以Jupiter 300 C4反相色谱柱作为第二维色谱分离柱。对两维色谱柱的选择优化为蛋白质高效分离二维液相色谱平台的搭建提供了可靠基础。  相似文献   

6.
Summary An ion chromatographic method has been developed for the separation of Te (IV) and Se(IV) in hydrochloric acid mobile phases; the method has been used to determine tellurium in a high-purity non-stoichiometric semiconducting ZnCdTe-based material. Different cation-exchange columns (IonPac CS2, CS3, CS10), a mixed bed ion-exchange column (IonPac CS5), a multi-mode cation-exchange column (OmniPac PCX-500), anion-exchange columns (IonPac AS4, AS4A, AS5, AS5A, AS10, AS11) and a multi-mode anion-exchange column (OmniPac PAX-500) were evaluated for ion chromatographic separation of Se and Te and to study the chemical forms in which the analytes were eluted. The chromatographic data obtained enabled the calculation of both the sign and the chaarge of the eluting species.  相似文献   

7.
A simple method for the chromatographic separation of the different molecular forms of human transferrin according to their respective iron contents is described. The appropriate conditions were developed with a Mono-S cation-exchange column.  相似文献   

8.
卢素格  沈金灿  庄峙厦  王小如 《色谱》2005,23(2):164-167
建立了金属硫蛋白(MT)异构体及亚型异构体的色谱分离与质谱鉴别方法。将金属硫蛋白混合物通过弱阴离子DEAE Sephadex A-25离子交换柱,结合离线电感耦合等离子体质谱(ICP-MS)对锌诱导金属硫蛋白的两个异构体MT-1和MT-2进行分离和检测;利用Sephadex G-25凝胶排阻色谱柱对得到的两个金属硫蛋白异构体进行脱盐;探索脱盐后的金属硫蛋白异构体在不同色谱条件下的C18反相色谱柱上的保留行为,进而实现各个亚型异构体的分离;通过在线电喷雾质谱检测实现了对金属硫蛋白各个亚型异构体的鉴别。结果表明,通过优化色谱条件,由离子交换色谱及凝胶排阻色谱得到的金属硫蛋白各亚型异构体在酸性条件下均得到了良好的分离,质谱检测结果与前人的文献报道结果一致。该方法可使金属硫蛋白各异构体均达到最佳的分离效果。  相似文献   

9.
A high-performance affinity chromatographic system was constructed and shown to permit highly reproducible, rapid, automatic assays of serum glycated albumin (GA) by separation of albumin (Alb) on an anion-exchange column (Asahipak ES-502N) packed with a vinyl alcohol copolymer bearing diethylamino groups and consecutive separation of GA on a column packed with a vinyl alcohol copolymer bearing boronate groups. The first column selectively retained Alb free of other serum proteins and permitted at least a 95% recovery of sample Alb. The purity of the Alb peak was confirmed by two-dimensional electrophoresis. Chromatographic analyses of human serum Alb incubated with glucose on the second column showed that the peak area for GA increased in accordance with the incubation time and suggested selective adsorption of GA on the second column. Optimization of the conditions for the two-column system reduced the analysis time to 10 min. Analyses of human sera with the present system showed GA to be 16.1 +/- 1.1% (mean +/- S.D.) of total Alb in non-diabetic children and 39.9 +/- 9.1% (mean +/- S.D.) in diabetic children (0-17 years old).  相似文献   

10.
A validated ion chromatographic method for the determination of anionic impurities in clodronic acid or disodium clodronate is described. Separations are performed by using an anion-exchange column (IonPac AS5) and a sodium hydroxide gradient. Impurities are detected by suppressed conductivity without the need for derivatisation. The most important variable affecting the separation was shown to be the column temperature.  相似文献   

11.
该文以聚苯胺/石墨烯复合材料为涂覆材料,制备了一种涂覆型阴离子交换固定相。首先以苯胺和石墨烯为原料制备聚苯胺/石墨烯复合材料,并通过物理吸附涂覆在聚苯乙烯-二乙烯苯微球表面;然后以聚苯胺中的氮原子为反应位点,通过季铵化制备一系列具有不同交换容量的涂覆型阴离子交换固定相。通过扫描电镜(SEM)、傅里叶红外光谱(FT-IR)和元素分析(EA)对该涂覆型阴离子交换固定相进行表征,结果表明聚苯胺/石墨烯成功地涂覆在微球表面且发生了季铵化。通过分离常规阴离子和有机酸,对自制阴离子交换色谱柱的色谱性能进行评价。结果显示,8次季铵化的聚苯胺/石墨烯涂覆聚苯乙烯-二乙烯苯阴离子交换色谱柱对常规阴离子和有机酸呈现良好的分离效果。  相似文献   

12.
A precise and accurate gas-liquid chromatographic (GLC) method has been developed for the quantitative analysis of the neutral sugars L-fucose (6-deoxygalactose), mannose, galactose, and glucose in ethanol precipitates of human serum proteins. The chromatographic conditions and sample preparation resulted in short analysis time (20 min per run) and made routine analyses practicable (twelve samples per day). The alditol acetate derivatization yielded single derivatives for each sugar. Complete separation was achieved on a 2.0 m X 2 mm I.D. column with 2.0% Silar-7CP on Chromosorb W AW 80--100 mesh. The results of hydrolysis showed that the release of fucose and galactose preceded the release of mannose. Hydrolysis with AG 50 W-X8 (H+) ion-exchange resin in 0.5 N HCl at 100 degrees for 7 h optimized glycosidic bond cleavage with only minimal destruction of fucose, mannose and galactose. A combination of strong cation- and anion-exchange resin columns was used to remove chromatographic background of peptides, amino acids, amino sugars, and inorganic ions. An average R.S.D. of less than 4% with recovery of greater than 86% for the three sugars was achieved. The homogeneity of the chromatographic peaks for the neutral sugars of normal human serum glycoproteins was confirmed by GLC--mass spectrometry. Significantly elevated ratios of fucose, galactose, and mannose to serum protein were observed for patients with small cell lung and ovarian carcinomas.  相似文献   

13.
Weak anion-exchange and reversed-phase high-performance liquid chromatographic methods for peptide separations were compared using a tryptic digest of "rat small myelin basic protein". In these experiments, a number of tryptic peptides that were not resolved on the reversed-phase column could be separated on the weak anion-exchange column, and in other instances, as might be expected, reversed-phase chromatography provided better resolution of certain peptides than did the weak anion-exchange method. The results obtained strongly suggest that the combined use of these two methods of separation, which utilize different selectivities, can provide an excellent improvement in resolving power for a number of peptide separations.  相似文献   

14.
A highly selective ion chromatographic method for the determination of ammonium ions using an anion-exchange separation column with a bipolar ion exchanger was developed. The method is based on the reaction in a suppressor column between ammonium ions and nitrous acid formed from the eluent components followed by the negative conductimetric signal. The determination of more than 0.1 ppm of NH4+ in water is possible in the presence of 100-fold amounts of alkali metals and inorganic anions.  相似文献   

15.
Certain diagnostic, analytical and preparative applications require the separation of immunoglobulin G (IgG) from immunoglobulin M (IgM). In the present work, different ion-exchange methacrylate monoliths were tested for the separation of IgG and IgM. The strong anion-exchange column had the highest dynamic binding capacity reaching more than 20mg of IgM/ml of support. Additionally, separation of IgM from human serum albumin, a common contaminant in immunoglobulin purification, was achieved on the weak ethylenediamino anion-exchange column, which set the basis for the IgM purification method developed on convective interaction media (CIM) supports. Experiments also confirmed flow independent characteristics of the short monolithic columns.  相似文献   

16.
This paper describes an ion-exclusion chromatographic system for the rapid and selective determination of ammonium ion. The optimized ion-exclusion chromatographic system was established with a polymethacrylate-based weakly basic anion-exchange resin column (TSKgel DEAE-5PW) as the separation column, an aqueous solution containing 0.05 mM tetramethylammonium hydroxide (pH 9.10) as eluent with conductimetric detection for the analyte determination. Under the optimum chromatographic conditions, ammonium ion was determined within 2.3 min with a detection limit (S/N=3) better than 0.125 microM. Ammonium ion in rain and river waters was precisely determined using this ion-exclusion chromatographic system.  相似文献   

17.
The scale-up of the separation of hen egg-white proteins has been investigated using Whatman DE92 anion-exchange cellulose. Having developed suitable chromatographic conditions, a maximum binding capacity of 100 mg protein/ml packed DE92 was determined in a 25-ml column. The process was scaled up 1000-fold and the influence of batch and column techniques on the chromatographic step assessed. Data indicate column processes to be more efficient than batch in the adsorptive stage.  相似文献   

18.
A high-performance liquid chromatographic method for the quantification of rufloxacin in human serum and urine has been developed and validated. The compounds, rufloxacin and internal standard, are extracted from buffered serum and urine using dichloromethane. They are then separated on an anion-exchange column using 0.05 M phosphate buffer-acetonitrile (80:20, v/v). The eluate is quantified by measuring the ultraviolet absorbance at 296 nm. The lower limit of detection for the analyte is 0.1 microgram/ml in serum and 0.05 micrograms/ml in urine. The method is linear from 0.3 to 10 micrograms/ml for serum and 0.1 to 10 micrograms/ml for urine. The method has been applied in a pharmacokinetic study in volunteers.  相似文献   

19.
High‐resolution capillary zone electrophoresis is used to assess the transferrin profile in serum of patients with eight different congenital disorders of glycosylation that represent type I, type II, and mixed type I/II disorders. Capillary zone electrophoresis data are compared to patterns obtained by gel isoelectric focusing. The high‐resolution capillary zone electrophoresis method is shown to represent an effective tool to assess the diversity of transferrin patterns. Hypoglycosylated disialo‐, monosialo‐, and asialo‐transferrin in type I cases can be distinguished from the corresponding underdesialylated transferrin glycoforms present in type II disorders. The latter can be separated from and detected ahead of their corresponding hypoglycosylated forms of type I patients. Both types of glycoforms are detected in sera of mixed type I/II patients. The assay has the potential to be used as screening method for congenital disorders of glycosylation. It can be run with a few microliters of serum when microvials are used.  相似文献   

20.
An automatic system is described for the determination of various uronic and biouronic acids after chromatographic separation on an anion-exchange column. Elution is carried out with sodium acetate or acetic acid, and the colors developed with carbazole and after oxidation with chromic acid are determined in a multichannel photometer and recorded continuously.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号