首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A collaborative study was conducted for the determination of paralytic shellfish poisoning (PSP) toxins in shellfish. The method used liquid chromatography with fluorescence detection after prechromatographic oxidation of the toxins with hydrogen peroxide and periodate. The PSP toxins studied were saxitoxin (STX), neosaxitoxin (NEO), gonyautoxins 2 and 3 (GTX2,3; together), gonyautoxins 1 and 4 (GTX1,4; together), decarbamoyl saxitoxin (dcSTX), B-1 (GTX5), C-1 and C-2 (C1,2; together), and C-3 and C-4 (C3,4; together). B-2 (GTX6) toxin was also included, but for qualitative identification only. Mussels, both blank and naturally contaminated, were mixed and homogenized to provide a variety of PSP toxin mixtures and concentration levels. The same procedure was followed with clams, oysters, and scallops. Twenty-one test samples in total were sent to 21 collaborators who agreed to participate in the study. Results were obtained from 18 laboratories representing 14 different countries. It is recommended that the method be adopted First Action by AOAC INTERNATIONAL.  相似文献   

2.
A novel method for the determination of paralytic shellfish poisoning (PSP) toxins using high-performance liquid chromatography with fluorescence detection was developed. The fluorescent derivates of neosaxitoxin (neoSTX), saxitoxin (STX), gonyautoxins 1 and 4 (GTX1+4), and gonyautoxins 2 and 3 (GTX2+3) were separated on a μBondapak NH2 column (300 mm × 3.9 mm, 10 μm) using water and acetate buffer (pH 6.5) as the mobile phase (1.00 mL min−1) in gradient mode with fluorescence detection at 390 nm (excitation at 330 nm). The linear ranges of neoSTX, STX, GTX1+4 and GTX2+3 were 3.31–331, 0.952–95.2, 3.78–378 and 0.124–12.4 ng mL−1, respectively. The detection limits of neoSTX, STX, GTX1+4 and GTX2+3 were 1.10, 0.32, 1.26 and 0.041 ng mL−1, respectively. The method was successfully applied to the determination of PSP toxins in microalgae. The recoveries ranged from 88±2% to 107±4% and the relative standard deviations were 0.16% to 4.4%. The procedure is also environmentally friendly because no organic solvent is used in the mobile phase.  相似文献   

3.
The prechromatographic oxidation LC method developed by Lawrence [J. Assoc. Off. Anal. Chem. 74, 404-409(1991)] for the determination of paralytic shellfish poisoning (PSP) toxins has been tested for the quantitative determination of PSP toxins in shellfish. All aspects of the method were studied and modified as necessary to improve its performance for routine regulatory purposes. The chromatographic conditions were changed to shorten analysis time. The oxidation reaction was tested for repeatability and the influence of the sample matrix on quantitation. An important part of the study was to quantitatively evaluate an ion exchange (-COOH) cleanup step using disposable solid-phase extraction cartridges that separated the PSP toxins into 3 distinct groups for quantitation, namely the C toxins, the GTX toxins, and the saxitoxin group. The cleanup step was very simple and used increasing concentrations of aqueous NaCl for elution of the toxins. The C toxins were not retained by the cartridges and thus were eluted unretained with water. The GTX toxins (GTX1 to GTX6 as well as dcGTX2 and dcGTX3) eluted from the cartridges with 0.05M NaCl while the saxitoxin group (saxitoxin, neosaxitoxin, and dcsaxitoxin) required 0.3M NaCl for elution. Each fraction was analyzed by LC after oxidation with periodate or peroxide. All of the compounds could be separated and quantitatively determined in spiked samples of mussels, clams, and oysters. The nonhydroxylated toxins could be quantitated at concentrations as low as about 0.02 microg/g (2 micro/100 g) of tissue while the hydroxylated toxins could be quantitated at concentrations as low as about 0.1 microg/g (10 microg/100 g). Average recoveries of the toxins through the complete cleanup procedure were 85% or greater for spiked extracts of oysters and clams and greater than 73% for mussels.  相似文献   

4.
A rapid liquid chromatographic (LC) method with postcolumn oxidation and fluorescence detection (excitation 330 nm, emission 390 nm) for the determination of paralytic shellfish toxins (PSTs) in shellfish tissue has been developed. Extracts prepared for mouse bioassay (MBA) were treated with trichloroacetic acid to precipitate protein, centrifuged, and pH-adjusted for LC analysis. Saxitoxin (STX), neoSTX (NEO), decarbamoylSTX (dcSTX), and the gonyautoxins, GTX1, GTX2, GTX3, GTX4, GTX5, dcGTX2, and dcGTX3, were separated on a polar-linked alkyl reversed-phase column using a step gradient elution; the N-sulfocarbamoyl GTXs, C1, C2, C3, and C4, were determined on a C-8 reversed-phase column in the isocratic mode. Relative toxicities were used to determine STX-dihydrochloride salt (diHCl) equivalents (STXeq). Calibration graphs were linear for all toxins studied with STX showing a correlation coefficient of 0.999 and linearity between 0.18 and 5.9 ng STX-diHCI injected (equivalent to 3.9-128 microg STXeq/100 g in tissue). Detection limits for individual toxins ranged from 0.07 microg STXeq/100 g for C1 and C3 to 4.1 microg STXeq/100 g for GTX1. Spike recoveries ranged from 76 to 112% in mussel tissue. The relative standard deviation (RSD) of repeated injections of GTX and STX working standard solutions was < 4%. Uncertainty of measurement at a level of 195 microg STXeq/100 g was 9%, and within-laboratory reproducibility expressed as RSD was 4.6% using the same material. Repeatability of a 65 microg STXeq/100 g sample was 3.0% RSD. Seventy-three samples were analyzed by the new postcolumn method and both AOAC Official Methods for PST determination: the MBA (y = 1.22x + 13.99, r2 = 0.86) and the precolumn LC oxidation method of Lawrence (y = 2.06x + 12.21, r2 = 0.82).  相似文献   

5.
Summary The development and application of chemical methods for monitoring paralytic shellfish poisoning (PSP) in coastal waters requires the availability of pure PSP standards. However only a few toxins are commercially available and only very small amounts of some of the other 18 PSP toxins identified are available at some research laboratories. A project is currently in progress for the isolation and purification of significant quantities of PSP toxins from contaminated mussels under the auspices of the Community Bureau of Reference of the Commission of the European Communities (BCR Programme). The PSP toxins from hepatopancreas of 500 kg of whole mussel were extracted and purified, and the following toxin profile was determined using a method based on Oshima et al. [1] GTX1, (24%), GTX2 (<1%), GTX3 (<1%), GTX4 (2.4%), GTX5 (5.8%), GTX6 (35.4%), C1 (11.5%), C2 (1.22%), neo-STX (11.4%), dc-STX (6.2%) and STX (2.4%). These toxins can be separated into three different fractions (STX-group, GTX-group and C-group), before proceeding to the purification of the individual toxins.  相似文献   

6.
Thin-layer chromatography (TLC) on Chromarods-SIII with the Iatroscan (Mark-5) and a flame thermionic detector (FTID) was used to develop a rapid method for the detection of paralytic shellfish poisoning (PSP) toxins. The effect of variation in hydrogen (H2) flow, air flow, scan time and detector current on the FTID peak response for both phosphatidylcholine (PC) and PSP were studied in order to define optimum detection conditions. A combination of hydrogen and air flow-rates of 50 ml/min and 1.5-2.0 l/min respectively, along with a scan time of 40 s/rod and detector current of 3.0 A (ampere) or above were found to yield the best results for the detection of PSP compounds. Increasing the detector current level to as high as 3.3 A gave about 130 times more FTID response than did flame ionization detection (FID), for PSP components. Quantities of standards as small as 1 ng neosaxitoxin (NEO), 5 ng saxitoxin (STX), 5 ng B1-toxins (B1), 2 ng gonyautoxin (GTX) 2/3, 6 ng GTX 1/4 and 6 ng C-toxins (C1/C2) could be detected with the FTID. The method detection limits for toxic shellfish tissues using the FTID were 0.4, 2.1, 0.8 and 2.5 micrograms per g tissue for GTX 2/3, STX, NEO and C toxins, respectively. The FTID response increased with increasing detector current and with increasing the scan time. Increasing hydrogen and air flow-rates resulted in decreasing sensitivity within defined limits. Numerous solvent systems were tested, and, solvent consisting of chloroform: methanol-water-acetic acid (30:50:8:2) could separate C toxins from GTX, which eluted ahead of NEO and STX. Accordingly, TLC/FTID with the Iatroscan (Mark-5) seems to be a promising, relatively inexpensive and rapid method of screening plant and animal tissues for PSP toxins.  相似文献   

7.
Paralytic shellfish toxins (PSTs), including gonyautoxins and saxitoxins, are produced by multiple species of microalgae and dinoflagellates, and are bioaccumulated by shellfish and other animals. Human exposure to PSTs typically occurs through ingestion of recreationally harvested contaminated shellfish and results in nonspecific symptomology. Confirmation of exposure to PSTs has often relied on the measurement of saxitoxin, the most toxic congener; however, gonyautoxins (GTXs), the sulfated carbamate derivatives of saxitoxin, may be present in shellfish at higher concentrations. To improve identification of PST exposures, our group has developed an online solid phase extraction hydrophilic interaction liquid chromatography method to identify GTX1–4 in human urine with tandem mass spectrometry. The reportable range varied for each analyte, with all falling within 0.899 and 250 ng/mL in urine with precision <15% and >85% accuracy as determined for all quality control samples. This new online method quantitates GTX1–4 following exposures to PSTs, supporting the work of public health authorities.  相似文献   

8.
The effect of pH on the oxidation of individual PSP toxins using both periodate and peroxide oxidations was studied. It was found that the optimum pH for individual toxins varied considerably. For periodate oxidations, pH 8.2 produced the maximum yield of fluorescent products for neosaxitoxin and GTX1/GTX4 while the non-hydroxylated toxins (saxitoxin, GTX2/GTX3, decarbamoyl saxitoxin, GTX5) showed optimum pHs from about pH 10-11.5. Neosaxitoxin and GTX1/GTX4 did not produce significant fluorescent oxidation products with peroxide oxidation at any of the pHs studied (pH 8.2-12.8). The non-hydroxylated toxins all showed optimum pHs above pH 12 with peroxide oxidation. Yields of fluorescent products of these toxins decreased substantially at pHs below pH 12. Neosaxitoxin and GTX1/GTX4 each produced three product peaks at pH 8.2 with periodate oxidation. There was no pH where these toxins produced predominantly a single oxidation product. Decarbamoyl saxitoxin always produced two oxidation products with both oxidation reactions at the pHs studied. However, the relative yields of the products changed with pH. At low pH the second eluting product predominated, while at higher pH values the first eluting product predominated. This pattern was observed for both oxidation reactions. The other non-hydroxylated toxins produced mainly single unique products with both oxidation reactions over the pH range studied. No single pH was found optimum for the oxidation of both hydroxylated and non-hydroxylated toxins without a significant compromise in yield of oxidation products. This has implications for the post column oxidation liquid chromatographic methods, since small changes in pH of the post column oxidant can both positively and negatively affect the yields of oxidation products of toxin mixtures leading to increased error in the subsequent quantitation of these compounds.  相似文献   

9.
A recently developed commercial rapid test kit (MIST Alert) was assessed for determination of the presence of paralytic shellfish poisoning (PSP) toxins in shellfish. Several commercially important shellfish species obtained from the UK shellfish toxin monitoring program, containing a range of total PSP toxicities as determined by the mouse bioassay (MBA), were tested. The kit detected toxin in all samples containing the European Community tolerance level of 80 microg saxitoxin (STX) equivalents/100 g shellfish flesh as determined by the MBA. With one exception, the kit detected toxin in all samples that contained >40 microg STX equivalents/100 g according to the MBA. Among samples in which the MBA did not detect toxin, the kit disagreed in 25% of the tests, although further analysis by liquid chromatography (LC) and MBA of some samples confirmed the presence of toxins. These results suggest that MIST Alert may be suitable as an initial screen for PSP toxins as part of routine monitoring programs, thereby greatly reducing the number of MBAs. Trials were also performed by nonscientific personnel to evaluate the ease of use and interpretation of results obtained by MIST Alert. The results indicated that the kits could be readily used and accurately interpreted by individuals with no technical or scientific background.  相似文献   

10.
A project was undertaken to develop mussel reference materials that were certified for their mass fractions of saxitoxin and decarbamoyl-saxitoxin. Fifteen laboratories from various European countries participated. Three of these had major responsibility for substantial parts of the work and overall coordination of the project. The project involved 4 main activities: (1) procurement and characterization of calibrants; (2) improvement of analytical methodology; (3) preparation of reference materials, including homogeneity and stability studies; (4) 2 interlaboratory studies and a certification exercise. The joint activities resulted in 3 homogeneous and stable reference materials: 2 lyophilized mussel materials with and without naturally incurred paralytic shellfish poisoning (PSP) toxins, and a saxitoxin enrichment solution. The reference materials were certified with respect to their saxitoxin and decarbamoyl-saxitoxin content. The lyophilized mussel material with PSP toxins (CRM 542) contained <0.07 mg saxitoxin x 2HCl/kg and 1.59 +/- 0.20 mg decarbamoyl-saxitoxin x 2HCl/kg. The lyophilized mussel material without PSP toxins (CRM 543) contained <0.07 mg saxitoxin x 2HCl/kg and <0.04 mg decarbamoyl-saxitoxin x 2HCl/kg. The certified value of the saxitoxin mass fraction in the saxitoxin enrichment solution (CRM 663) was 9.8 +/- 1.2 microg/g.  相似文献   

11.
Immunoassay methods for paralytic shellfish poisoning toxins   总被引:1,自引:0,他引:1  
The current status of immunochemical techniques for analysis of paralytic shellfish poisoning (PSP) toxins is summarized. Important aspects regarding production of the biological reagents necessary for immunochemical methods, the characteristics of polyclonal and monoclonal antibodies against saxitoxin and neosaxitoxin, and the importance of test sensitivity and specificity are discussed. Applications of immunochemical techniques for PSP toxins include microtiter plate enzyme immunoasays and enzyme-linked immunofiltration assays for toxin detection, and immunoaffinity chromatography (IAC) for sample extract cleanup. A major advantage of enzyme immunoassay (EIA) is simplicity and rapidity of the test procedure, and higher sensitivity than other methods. However, quantitative agreement between EIA and mouse bioassay is dependent on antibody specificity and the toxin profile in the shellfish; thus, both over- and underestimation of total toxicity may occur. For screening purposes, however, EIAs offer major advantages over the mouse bioassay, which is criticized in Europe because of animal welfare. A major application of antibodies against PSP toxins is their use for extract cleanup by IAC, which gives highly purified extracts, thereby enhancing determination of PSP toxins by conventional physicochemical methods such as liquid chromatography. IAC can also be used to isolate PSP toxins for preparation of analytical standard solutions.  相似文献   

12.
Ionspray mass spectrometry has been used to monitor the purification of saxitoxin, the parent compound in the family of toxins responsible for paralytic shellfish poisoning (PSP), from a strain of the dinoflagellate Alexandrium excavatum. Quantitative results obtained by flow-injection analysis are compared to those obtained by high-performance liquid chromatography with post-column oxidation and fluorescence detection. The coupling of liquid chromatography and capillary electrophoresis with ionspray mass spectrometry is described for the separation of mixtures of PSP toxins and the highly potent pufferfish toxin tetrodotoxin. Tandem mass spectrometry is used to provide the structural information, and the ability to distinguish isomeric PSP toxins both chromatographically and mass spectrometrically is demonstrated.  相似文献   

13.
At present, the analytical method for paralytic shellfish poisoning (PSP) toxins in shellfish is the mouse bioassay (MBA), which is an official method of the Association of Analytical Communities (AOAC [8]). However, the low sensitivity and concerns over the number of live animals required for testing have been cited as the major reason for seeking its replacement. In this report, we employed an open-sandwich immunoassay (OS-IA) to detect gonyautoxin (GTX2/3), a kind of PSP toxins. OS-IA, which utilizes the antigen-induced enhancement of antibody VH/VL interaction, can measure a small molecule antigen in a noncompetitive format. Hence it has a wider working range and shorter measurement time. We isolated anti-GTX2/3 antibody gene from a hybridoma GT-13A by screening a Fab-displaying phage library. Then the vectors for OS-IA were constructed, and examined for antigen concentration-dependency of the VH/VL interaction by OS-ELISA. As a result, in each case, signal intensity increases notably in a wide concentration range (0.1 to >1000 ng mL−1) of free GTX2/3, which was enough to cover its regulation value (80 μg 100 g−1) in many countries. So OS-IA will be widely applicable to detect PSP toxins in shellfish meats and in drinking water.  相似文献   

14.
A refined version of the pre-column oxidation liquid chromatography with fluorescence detection (ox-LC-FLD) official method AOAC 2005.06 was developed in the UK and validated for the determination of paralytic shellfish poisoning toxins in UK shellfish. Analysis was undertaken here for the comparison of PSP toxicities determined using the LC method for a range of UK bivalve shellfish species against the official European reference method, the PSP mouse bioassay (MBA, AOAC 959.08). Comparative results indicated a good correlation in results for some species (mussels, cockles and clams) but a poor correlation for two species of oysters (Pacific oysters and native oysters), where the LC results in terms of total saxitoxin equivalents were found to be on average more than double the values determined by MBA. With the potential for either LC over-estimation or MBA under-estimation, additional oyster and mussel samples were analysed using MBA and ox-LC-FLD together with further analytical and functional methodologies: a post-column oxidation LC method (LC-ox-FLD), an electrophysiological assay and hydrophilic interaction liquid chromatography with tandem mass spectrometric detection. Results highlighted a good correlation among non-bioassay results, indicating a likely cause of difference was the under-estimation in the MBA, rather than an over-estimation in the LC results.  相似文献   

15.
Paralytic shellfish poisoning (PSP) toxins are produced by certain marine dinoflagellates and may accumulate in bivalve molluscs through filter feeding. The Mouse Bioassay (MBA) is the internationally recognised reference method of analysis, but it is prone to technical difficulties and regarded with increasing disapproval due to ethical reasons. As such, alternative methods are required. A rapid surface plasmon resonance (SPR) biosensor inhibition assay was developed to detect PSP toxins in shellfish by employing a saxitoxin polyclonal antibody (R895). Using an assay developed for and validated on the Biacore Q biosensor system, this project focused on transferring the assay to a high-throughput, Biacore T100 biosensor in another laboratory. This was achieved using a prototype PSP toxin kit and recommended assay parameters based on the Biacore Q method. A monoclonal antibody (GT13A) was also assessed. Even though these two instruments are based on SPR principles, they vary widely in their mode of operation including differences in the integrated μ-fluidic cartridges, autosampler system, and sensor chip compatibilities. Shellfish samples (n = 60), extracted using a simple, rapid procedure, were analysed using each platform, and results were compared to AOAC high performance liquid chromatography (HPLC) and MBA methods. The overall agreement, based on statistical 2 × 2 comparison tables, between each method ranged from 85% to 94.4% using R895 and 77.8% to 100% using GT13A. The results demonstrated that the antibody based assays with high sensitivity and broad specificity to PSP toxins can be applied to different biosensor platforms.  相似文献   

16.
Analysis of paralytic shellfish poisons by capillary electrophoresis   总被引:3,自引:0,他引:3  
A capillary electrophoresis (CE) method with UV detection is described for the separation and determination of underivatized toxins associated with paralytic shellfish poisoning (PSP). Confirmation of the electrophoretic peaks was facilitated by mass spectrometric (MS) detection using an ionspray CE-MS interface and by high-performance liquid chromatography with fluorescence detection. The determination of PSP toxins, such as saxitoxin and neosaxitoxin, in toxic dinoflagellates and scallops is demonstrated and comparisons are made with existing techniques.  相似文献   

17.
The presence of paralytic shellfish poisoning (PSP) toxins has not been recorded in the Portuguese coast since 1995. A bloom of Gymnodinium catenatum occurred in the NW coast of Portugal in the autumn of 2005, and PSP profiles were determined in several inshore and offshore shellfish species by HPLC after pre-column oxidation. Most of the species studied contained a complex toxin profile, typically representative of contamination by G. catenatum. However, clams such as Spisula solida contained mainly decarbamoyl toxins, while less extensive transformation was found in Scrobicularia plana. In vitro incubation of S. solida digestive glands with PSP standards revealed a rapid transformation of carbamate and N-sulfocarbamoyl toxins into their corresponding decarbamate analogues. After 24 h, less than 5% of the carbamate or N-sulfocarbamoyl toxins tested remained. After a 24 h in vitro incubation of S. plana digestive glands, no decarbamate analogues were detected. Artificial toxification of S. plana with cultures of G. catenatum revealed the conversion into decarbamoyl analogues progressed slowly: initially dcGTX2+3 and dcSTX accounted only for 5% of total non N-1 hydroxilated toxins, after 6 days these toxins accounted for 41% of the toxin composition. In vitro incubations of digestive glands from other commercial bivalves did not reveal production of decarbamoyl analogues over a 24 h period.  相似文献   

18.
香港海域毒性微藻Alexandium tamarense的麻痹性贝毒研究   总被引:2,自引:0,他引:2  
对从香港海域底坭分离并培养的毒性微藻塔玛亚历山大藻(Alexandiumtamareuse)的毒性和麻痹性贝毒素的组成进行研究。由生物试验测得其毒性为4.11×10-6MU/cell,用高效液相色谱分析毒素的组成,结果表明所含麻痹性贝毒成分主要是膝沟藻毒素-2(GTX2),含量为94.13pg/cell,本研究所用的微藻毒素提取方法和高效液相色谱分析方法都比较容易和有效。  相似文献   

19.
AOAC Official Method 2005.06 LC-fluorescence detection (FLD) method is an official alternative to the mouse bioassay for the determination of paralytic shellfish poisoning (PSP) toxins in bivalve shellfish. To validate the method for species of relevance to the UK official control monitoring program, the method performance characteristics were tested for whole king and queen scallops. Validation showed that, while the performance was generally acceptable for the quantitation of non-N-hydroxylated toxins, poor toxin recovery and sensitivity was evident for the analysis of N-hydroxylated toxins following periodate oxidation. These effects occurred in a range of scallop samples with variable temporal and spatial sources. The effects were also noted in other laboratories following a small interlaboratory study. As a result, the method was refined to improve the recovery and sensitivity of analysis following the periodate oxidation step in the PSP method for scallops. Performance improved through alterations to the preparation of the periodate oxidant, use of higher volumes for C18 cleanup, and injection volumes in combination with the use of a king scallop matrix modifier for oxidation of N-hydroxylated toxin calibration standards. A single-laboratory validation of the refined method showed that the selectivity, linearity, sensitivity, recovery, and precision were acceptable and similar to values reported previously for AOAC Official Method 2005.06 in other bivalve species. Results showed the method to be rugged for all parameters investigated, including small changes to the composition of the new periodate reagent utilized in the refined method. The refined scallops LC method was subsequently compared with the European reference method. PSP-positive scallops showed an excellent agreement between the methods for queen and Atlantic scallops, with a small level of positive bias in the LC results for whole king scallops. These differences were related solely to the use of the highest toxicity equivalence factors for toxin epimeric pairs, with gonyautoxin (GTX)1,4 and GTX2,3 in particular present at high concentrations in the king scallops. Overall, the refined LC-FLD method improved the performance characteristics of AOAC Official Method 2005.06 for the determination of PSP toxins in whole king and queen scallops, and showed a good overall agreement between the official methodologies. It is, therefore, recommended as a more appropriate option for the routine monitoring of PSP toxins in these species.  相似文献   

20.
Baseline separation of seven paralytic shellfish toxins (PSTs), namely decarbamoylsaxitoxin (dcSTX), saxitoxin (STX), neosaxitoxin (NEO), gonyautoxin-2 (GTX-2), gonyautoxin-3 (GTX-3), gonyautoxin-1 (GTX-1), and gonyautoxin-4 (GTX-4), was achieved by using capillary ITP (CITP)/CE with UV detection. Separation parameters including duration time and voltage in CITP process, separation voltage, and pH and concentration of buffer were optimized. The developed method provided linear responses from 1.3 to 200 microM for the PSTs. The LOD ranged from 0.1 to 0.3 microM. PST extracts from two algal strains of Alexandrium tamarense were analyzed and the toxin concentrations in the samples were quantified with an internal standard method by using NEO as the internal standard. The algal extract of A. tamarense HK9301 contained 332 microM GTX-2 and 224 microM GTX-3, while the PSTs were not detected in the extract of A. tamarense CI01.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号