首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this paper, cellular automata are used to detect the nuclear tracks in the track images captured from the surface of CR-39 detectors. Parameters of the automaton as the states, neighborhood, rules and quality parameters are defined optimally for the track image data set under analysis. The presented method is a supervised computational algorithm which comprises a rule definition phase as the learning procedure. Parameter optimization is also performed to adapt the algorithm to the data set used.  相似文献   

2.
用20—1020 keV单能质子刻度CR-39固体核径迹探测器   总被引:1,自引:0,他引:1       下载免费PDF全文
用北京师范大学2×1.7MV串列加速器和400 kV高压倍加器产生的20—1020 keV单能质子束对CR-39固体核径迹探测器进行了刻度.为了保证质子的单能性和固体核径迹探测器上径迹密度不能超过106/cm2的要求,对两台加速器分别采用了不同方法控制质子辐照数量.在串列加速器上采用了狭缝加转盘的方法,在高压倍加器上采用了100 ns单次高压脉冲扫描束流的方法,既保持了质子的单色性,又达到了质子注量小于106/cm2关键词: 单能质子 固体核径迹探测器 CR-39  相似文献   

3.
4.
This paper presents the results of the influence of soft X-ray radiation on craters induced in SSNTDs by energetic α particles and protons of energy in the MeV range. We checked two detectors of the PM-355 and CR-39 types in order to verify and compare their resistance to the harsh conditions of high-temperature plasma experiments. To determine this effect some detector samples were first irradiated with α particles emitted from natural α particle sources and protons delivered by a particle accelerator. After that these samples were exposed to soft X ray radiation emitted from an X ray tube and also from the PF-1000 Plasma Focus facility. Doses during X ray irradiations varied from 0 up to tens of kGy. The irradiated samples were then etched in steps and track diameters were determined versus the absorbed dose and etching time and compared with those measured in samples not exposed to X ray radiation.  相似文献   

5.
A miniature diffusion chamber with a 25 × 4 × 0.5 mm CR-39 track etch detector (Pershore Moulding Ltd.), mounted on the 1.1 m long pole has been developed for radon gas measurements at 1 meter depth in the soil. For chemically etched CR-39 (7h, 70°C NaOH) and automatic track analysis the lowest detection limit of the chamber was found to be 0.5 MBq h m−3 and the useful exposure range from 2 to 20 MBq h m−3. The typical exposure time in the soil is between 2 to 14 days. The chamber was tested against the active AlphaGUARD PQ-2000 (Genitron Instruments GmbH) probe. The test yielded consistent results for soils with typical values of permeability and which are not miniature with water. The pilot measurements of radon gas in soil conducted with the miniature diffusion chambers around 48 buildings in Kraków and Silesia regions yielded an average radon concentration of 13 kBq m−3. The chambers are to be applied to measure radon concentration in soil before constructing new houses in order to avoid high radon risk areas.  相似文献   

6.
It has been demonstrated that high-energy heavy ions undergo fission while propagating in dielectric solids. Since these materials act as particle detectors because of their ability to retain primary ionization damage that can be fixed and enlarged with chemical etching, therefore, in principle, a complete kinematical analysis of fission events is possible. The crucial point in this regard is the availability of a well-calibrated range-energy relation, which is necessary for mass identification. We have developed an analytical method to convert the geometrical parameters of fission fragment tracks into physical parameters using an equation that expresses velocity as a polynomial of mass and range. A set of nine different polynomials was used to represent small regions of mass and range in order to improve accuracy. In the case of (15.9 MeV/u) Au ions incident normally on CR-39, we have found about 200 events which could be categorized as in-flight fission of Au ions inside the body of the detector. Mass distributions and cross sections of fission events have been calculated.  相似文献   

7.
Samples of CR-39, PM-355, and PM-500 plastic detectors were irradiated with carbon ions of energy ranging from 0.9 MeV to 14.7 MeV. After the irradiation the detector samples were etched for a period from 2 hrs to 10 hrs. Dependence of track diameters on the ion energy values for different etching times, and dependence of VT/VB as a function of incident carbon-ion energy, are presented.  相似文献   

8.
The paper concerns applications of LR-115A, CR-39 and PM-355 solid-state nuclear-track detectors (SSNTDs) for investigation of pulsed fluxes of protons below 300 keV. The proton streams were generated by the RPI-IBIS device operated with hydrogen puffing [Baranowski et al. 2000. Studies of hydrogen discharges in RPI-type devices with different electrode configurations. Czech. J. Phys. 50 (Suppl. S3), 101–107]. To perform ion mass- and energy-analysis, a Thomson mass-spectrometer equipped with a special input system and exchangeable detectors was used. A quantitative analysis of proton tracks upon Thomson parabolas was performed by means of an optical microscope equipped with a CCD camera. It made possible to measure proton tracks and to determine their statistics. The paper presents proton energy spectra recorded with the selected detectors, and responses of these detectors to protons of energy from about 30 to 300 keV. The results are important for verification of detector characteristics and for measurements of protons at different experimental conditions.  相似文献   

9.
In the present paper the sensitivity V of plastic nuclear track detectors CR-39 to the space radiation, accelerated heavy ions in wide LET range and α-particles is studied. Different approaches for V evaluation are considered and compared. Main attention is given to the method that is appropriate for the measurement of short range heavy secondaries of space radiation. Finally, the experimental verification of the designed V function is carried out via simulation of the secondaries with low energy α-particles in the vicinity of the Bragg peak.  相似文献   

10.
《Radiation measurements》2001,34(1-6):337-339
The paper presents an additional acceleration system, used to shift up an ion energy spectrum by 20 keV, and some examples of the ion parabolas registered by means of a Thomson-type spectrometer within the rod plasma injector (RPI-60) facility, designed for plasma physics and application studies. The use of the described acceleration system and CR-39 track detectors has enabled the registration of ions of energy above 20 keV to be performed. It made possible to measure the ion (e.g. deuteron) energy spectrum more exactly in the low-energy range, what is important for the determination of ion emission characteristics.  相似文献   

11.
Samples made of the CR-39 and PM-355 plastic nuclear track detectors (NTDs) as well as of the CN films were irradiated with quasi-monoenergetic beams of protons, alphas, N+-, and O+-ions produced by various accelerators. For different samples an energy value of the particle beams was changed from several hundreds keV to 3 or 4.5 MeV. After irradiation the detector samples were etched chemically under controlled conditions during periods lasting from 2 hrs to 20 hrs. Every 2 hrs track diameters were measured by means of an optical microscope. Differences in the crater diameters in the detectors etched in steps, and those etched continously, have been found to be smaller than 10 percent. The paper results detailed calibration diagrams showing a dependence of track diameters on the ion energy value for different etching times.  相似文献   

12.
The effect of additives and cure cyle parameters on pre and post irradiation annealing characteristics of CR-39 detectors has been investigated. Effect of pre and post irradiation annealing on bulk etch rate, sensitivity, track diameter and etching behaviour of various CR-39 detectors has been investigated.  相似文献   

13.
S M Farid 《Pramana》1985,24(3):475-484
Samples of Lexan and Makrofol-E polycarbonate plastic track detectors were exposed to 1·1 MeV/N 54 132 Xe-ions to investigate the thermal track fading properties of these plastics. The experimental results show that there is no effect of annealing on the bulk etch rate while the track etch rate decreases with annealing. The track diameter decreases with increase in annealing time and temperature. It is also observed that the track density is reduced as a result of annealing. The experiments reveal that the track lengths are, in general, decreased by the application of heat and that the oblique tracks are less stable than the vertical tracks. The decrease in diameter of 54 132 Xe-ion tracks in Makrofol-E due to heat treatment is faster than that of 54 132 Xe-ion tracks in Lexan.  相似文献   

14.
Computer programs have been developed to calculate track parameters and to plot track openings and wall profiles. The programs are based on equations derived for three-dimensional consideration of track development. All possible cases of track openings and wall profiles are obtainable from these equations. Results are given for lengths of major and minor axes, track depths and surface areas of track openings. Some examples of track openings and wall profiles are also presented.  相似文献   

15.
Abstract

The effects of neutron, gamma and alpha radiations on the alpha and fission fragment tracks registration and revelation properties of CR-39 detectors (CR-39 and CR-39(DOP) were studied. It was found that the ratio of the bulk etch rate of irradiated to unirradiated (VG(irr.)/VG(unirr.) detectors is linearly dependent on dose. An exponential decrease in fission track densities with increase in neutron fluence was observed. The ratio of VG(irr.)/VG(unirr.) was found to be high in CR-39 than that in CR-39(DOP) exposed to the same reactor neutron fluence. The decrease in fission track densities with increase in neutron fluence was observed to be faster in CR-39 than in CR-39(DOP). This indicates that doping with dioctyl phthalate improves the radiation resistance of CR-39 detectors. It was observed that in detectors exposed to an alpha flux of the order of 9.36 × 106 / cm2, the fission track density was reduced by 11% and thereafter it remained constant. The results also indicate that thermal neutron fluence up to 7.01 ×1011 neutrons/cm2 does not affect the alpha and fission track densities. I.R. spectra were also studied to find out the nature of chemical changes produced by these radiations on CR-39.  相似文献   

16.
《Radiation measurements》1995,25(1-4):175-176
The paper presents new results of the calibration of the standard CR-39 and super-grade PM-355 plastic detectors, which are applicable for the registration of the protons, deuterons, and 4He-ions. The calibration diagram show track diameters vs particle energy for different etching times.  相似文献   

17.
Two types of polymeric track detectors CR-39 and SR-90 were irradiated with protons, alpha particles, heavy ions and gamma-rays at different energies and fluences. After irradiation these detectors were analyzed with an FT-IR spectrometer of Jasco type 5300 in transmission and ATR modes. We have found that CO2 is produced not only by irradiation but also by polymerization. The amount of CO2 in the detector material is closely related to the latent track formation.  相似文献   

18.
A simple experimental technique has been described for measuring range and energy-loss of any heavy ion in any complex medium with the help of a sensitive solid state nuclear track detectors (SSNTDs). In this paper we present the results obtained from our measurements of ranges and energy-loss of 16.34 MeV/u238U in Makrofol-N using CR-39 track detector. Experimental ranges are compared with the corresponding theoretical values. The significance and scope of the present work are discussed.  相似文献   

19.
The molecular structure of SR-90 and CR-39 is very similar except that the average length of carbonate linkages in SR-90 is 1.6 times longer than in CR-39. However, the effect of vacuum and carbon dioxide (CO2) on the track registration of these two detectors is very different: 1) the sensitivity of CR-39 becomes very low in vacuum; the sensitivity of SR-90 does not go down to zero even after storage in vacuum for a long time; 2) the sensitivity of SR-90 decreases both in air and in vacuum but the original sensitivity can be restored by storing it in CO2 of 13 atm for several days. We also found that the sensitization of latent tracks by oxygen (O2) is effective only at the time of irradiation but the sensitization by CO2 is effective after irradiation.  相似文献   

20.
The paper reports on the analysis of responses of CN-type films and CR39-plastic nuclear track detectors (NTDs) to fast deutrons and nitrogen ions emitted from high-current Plasma-Focus (PF) facilities, as operated at SINS and INFIP. In order to separate the deutrons and nitrogen ions of different energy, the use was made of a Thomson-type mass-spectrometer adapted to measurements within dense plasma streams. Deutron and ion parabolaen were registered the CN-80 and CN-LR115 films as well as with the CR39 plastic NTDs, which were undergone routine etching procedures. On the basisof known characteristics of the spectrometer applied energy- and mass-scales for the obtained ion paraboale were determined. Using an optical microscope, a detailed analysis of track dimensions was performed in chosen points along the registered parabolae, and the calibration diagrams (i.e. a track diameter for the chosen ion energy and different etching times) were determined. Results of the calibration procedure, after comparing with other calibration data obtained with conventional particle accelerators, may be applicable for measurements of fast deutrons (i.g., in nuclear fusion experiments) and energetic nitrogen ions (i.g., in some plasma- and ion-facilities used for technological applications).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏