首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 437 毫秒
1.
PurposeTo evaluate the perfusion parameters of inner and outer myometrium in healthy nulliparous and primiparous women who are and who are not currently using hormonal contraceptives by means of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI).Material and methodsWe performed pelvic 1.5 T DCE-MRI on 98 women: 18 nulliparous non-users, 30 nulliparous users, 12 primiparous non-users and 38 primiparous users of hormonal contraception (mean age respectively 26.4, 25.8, 30.23 and 28.18 years). The nulliparous non-users underwent DCE-MRI investigations during their follicular, ovulatory and luteal phase. Perfusion parameters (iAUC/volume, Ktrans, Kep and Ve) were assessed in the anterior and posterior junctional zone (JZ), outer myometrium and cervix.ResultsIn nulliparous non-users, the mean Ktrans and iAUC/volume showed a decrease from follicular to luteal phase (0.82 vs 0.55 min 1 for Ktrans, p = 0/027 and 1.28 vs 0.68 for iAUC/volume, p < 0.001). The anterior JZ demonstrated lower Ktrans (p = 0.050) and higher Kep (p = 0.012), in nulliparous non-users, lower Ktrans in nulliparous users (p < 0.001) and lower Ve in primiparous users (p = 0.012) than the anterior outer myometrium. Ktrans at the anterior and posterior JZ wall in nulliparous users was lower than in non-users (p = 0.001 and p = 0.013) and Ve at the anterior JZ wall in primiparous users was lower than in non-users (p = 0.044).ConclusionThis study provides data on normal perfusion parameters of inner and outer myometrium, which may be potentially useful in assisted reproductive therapy.  相似文献   

2.
PurposeTo quantify the differential plasma flow- (Fp-) and permeability surface area product per unit mass of tissue- (PS-) weighting in forward volumetric transfer constant (Ktrans) estimates by using a low molecular (Gd-DTPA) versus high molecular (Gadomer) weight contrast agent in dynamic contrast enhanced (DCE) MRI.Materials and methodsDCE MRI was performed using a 7T animal scanner in 14 C57BL/6J mice syngeneic for TRAMP tumors, by administering Gd-DTPA (0.9 kD) in eight mice and Gadomer (35 kD) in the remainder. The acquisition time was 10 min with a sampling rate of one image every 2 s. Pharmacokinetic modeling was performed to obtain Ktrans by using Extended Tofts model (ETM). In addition, the adiabatic approximation to the tissue homogeneity (AATH) model was employed to obtain the relative contributions of Fp and PS.ResultsThe Ktrans values derived from DCE-MRI with Gd-DTPA showed significant correlations with both PS (r2 = 0.64, p = 0.009) and Fp (r2 = 0.57, p = 0.016), whereas those with Gadomer were found only significantly correlated with PS (r2 = 0.96, p = 0.0003) but not with Fp (r2 = 0.34, p = 0.111). A voxel-based analysis showed that Ktrans approximated PS (< 30% difference) in 78.3% of perfused tumor volume for Gadomer, but only 37.3% for Gd-DTPA.ConclusionsThe differential contributions of Fp and PS in estimating Ktrans values vary with the molecular weight of the contrast agent used. The macromolecular contrast agent resulted in Ktrans values that were much less dependent on flow. These findings support the use of macromolecular contrast agents for estimating tumor vessel permeability with DCE-MRI.  相似文献   

3.
PurposeZero padding is a well-studied interpolation technique that improves image visualization without increasing image resolution. This interpolation is often performed as a last step before images are displayed on clinical workstations. Here, we seek to demonstrate the importance of zero padding before rather than after performing non-linear post-processing algorithms, such as Quantitative Susceptibility Mapping (QSM). To do so, we evaluate apparent spatial resolution, relative error and depiction of multiple sclerosis (MS) lesions on images that were zero padded prior to, in the middle of, and after the application of the QSM algorithm.Materials and MethodsHigh resolution gradient echo (GRE) data were acquired on twenty MS patients, from which low resolution data were derived using k-space cropping. Pre-, mid-, and post-zero padded QSM images were reconstructed from these low resolution data by zero padding prior to field mapping, after field mapping, and after susceptibility mapping, respectively. Using high resolution QSM as the gold standard, apparent spatial resolution, relative error, and image quality of the pre-, mid-, and post-zero padded QSM images were measured and compared.ResultsBoth the accuracy and apparent spatial resolution of the pre-zero padded QSM was higher than that of mid-zero padded QSM (p < 0.001; p < 0.001), which was higher than that of post-zero padded QSM (p < 0.001; p < 0.001). The image quality of pre-zero padded reconstructions was higher than that of mid- and post-zero padded reconstructions (p = 0.004; p < 0.001).ConclusionZero padding of the complex GRE data prior to nonlinear susceptibility mapping improves image accuracy and apparent resolution compared to zero padding afterwards. It also provides better delineation of MS lesion geometry, which may improve lesion subclassification and disease monitoring in MS patients.  相似文献   

4.
PurposeBiochemical imaging of glycosaminoglycan chemical exchange saturation transfer (gagCEST) could predict the depletion of glycosaminoglycans (GAG) in early osteoarthritis. The purpose of this study was to evaluate the relationship between the magnetization transfer ratio asymmetry (MTRasym) of gagCEST images and visual analog scale (VAS) pain scores in the knee joint.Materials and methodsThis retrospective study was approved by the institutional review board. A phantom study was performed using hyaluronic acid to validate the MTRasym values of gagCEST images. Knee magnetic resonance (MR) images of 22 patients (male, 9; female, 13; mean age, 50.3 years; age range; 25–79 years) with knee pain were included in this study. The MR imaging (MRI) protocol involved standard knee MRI as well as gagCEST imaging, which allowed region-of-interest analyses of the patellar facet and femoral trochlea. The MTRasym at 1.0 ppm was calculated at each region. The cartilages of the patellar facets and femoral trochlea were graded according to the Outerbridge classification system. Data regarding the VAS scores of knee pain were collected from the electronic medical records of the patients. Statistical analysis was performed using Spearman's correlation.ResultsThe results of the phantom study revealed excellent correlation between the MTRasym values and the concentration of GAGs (r = 0.961; p = 0.003). The cartilage grades on the MR images showed significant negative correlation with the MTRasym values in the patellar facet and femoral trochlea (r = −0.460; p = 0.031 and r = −0.543; p = 0.009, respectively). The VAS pain scores showed significant negative correlation with the MTRasym values in the patellar facet and femoral trochlea (r = −0.435; p = 0.043 and r = −0.671; p = 0.001, respectively).ConclusionThe pain scores were associated with the morphological and biochemical changes in articular cartilages visualized on knee MR images. The biochemical changes, visualized in terms of the MTRasym values of the gagCEST images, exhibited greater correlation with the pain scores than the morphological changes visualized on conventional MR images; these results provide evidence supporting the theory regarding the association of patellofemoral osteoarthritis with knee pain scores.  相似文献   

5.
PurposeTo explore the application of histogram analysis in preoperative T and N staging of gastric cancers, with a focus on characteristic parameters of apparent diffusion coefficient (ADC) maps.Materials and methodsEighty-seven patients with gastric cancers underwent diffusion weighted magnetic resonance imaging (b = 0, 1000 s/mm2), which generated ADC maps. Whole-volume histogram analysis was performed on ADC maps and 7 characteristic parameters were obtained. All those patients underwent surgery and postoperative pathologic T and N stages were determined.ResultsFour parameters, including skew, kurtosis, s-sDav and sample number, showed significant differences among gastric cancers at different T and N stages. Most parameters correlated with T and N stages significantly and worked in differentiating gastric cancers at different T or N stages. Especially skew yielded a sensitivity of 0.758, a specificity of 0.810, and an area under the curve (AUC) of 0.802 for differentiating gastric cancers with and without lymph node metastasis (P < 0.001). All the parameters, except AUClow, showed good or excellent inter-observer agreement with intra-class correlation coefficients ranging from 0.710 to 0.991.ConclusionCharacteristic parameters derived from whole-volume ADC histogram analysis could help assessing preoperative T and N stages of gastric cancers.  相似文献   

6.
PurposeTo compare enhanced Laws textures derived from parametric proton density (PD) maps to other MRI surrogate markers (T2, PD, apparent diffusion coefficient (ADC)) in assessing degrees of liver fibrosis in an ex vivo murine model of hepatic fibrosis imaged using 11.7T MRI.MethodsThis animal study was IACUC approved. Fourteen male, C57BL/6 mice were divided into control and experimental groups. The latter were fed a 3,5-dicarbethoxy-1,4-dihydrocollidine (DDC) supplemented diet to induce hepatic fibrosis. Ex vivo liver specimens were imaged using an 11.7T scanner, from which the parametric PD, T2, and ADC maps were generated from spin-echo pulsed field gradient and multi-echo spin-echo acquisitions. A sequential enhanced Laws texture analysis was applied to the PD maps: automated dual-clustering algorithm, optimal thresholding algorithm, global grayscale correction, and Laws texture features extraction. Degrees of fibrosis were independently assessed by digital image analysis (a.k.a. %Area Fibrosis). Scatterplot graphs comparing enhanced Laws texture features, T2, PD, and ADC values to degrees of fibrosis were generated and correlation coefficients were calculated.ResultsHepatic fibrosis and the enhanced Laws texture features were strongly correlated with higher %Area Fibrosis associated with higher Laws textures (r = 0.89). Without the proposed enhancements, only a moderate correlation was detected between %Area Fibrosis and unenhanced Laws texture features (r = 0.70). Correlation also existed between %Area Fibrosis and ADC (r = 0.86), PD (r = 0.65), and T2 (r = 0.66).ConclusionsHigher degrees of hepatic fibrosis are associated with increased Laws textures. The proposed enhancements could improve the accuracy of Laws texture features significantly.  相似文献   

7.
PurposeTo investigate if intravoxel incoherent motion (IVIM) modeled diffusion-weighted imaging (DWI) can be linked to contrast-enhanced (CE-)MRI in liver parenchyma and liver lesions.MethodsTwenty-five patients underwent IVIM-DWI followed by multiphase CE-MRI using Gd-EOB-DTPA (n = 20) or Gd-DOTA (n = 5) concluded with IVIM-DWI. Diffusion (Dslow), microperfusion (Dfast), its fraction (ffast), wash-in-rate (Rearly) and late-enhancement-rate (Rlate) of Gd-EOB-DTPA were calculated voxel-wise for the liver. Parenchyma and lesions were segmented. Pre-contrast IVIM was compared 1) between low, medium and high Rearly for parenchyma 2) to post-contrast IVIM substantiated with simulations 3) between low and high Rlate per lesion type.ResultsDfast and ffast increased (P < 0.001) with 25.6% and 33.8% between low and high Rearly of Gd-EOB-DTPA. Dslow decreased (− 15.0%; P < 0.001) with increasing Rearly. Gd-DOTA demonstrated similar observations. ffast (+ 10%; P < 0.001) and Dfast (+ 6.6%; P < 0.001) increased after Gd-EOB-DTPA, while decreasing after Gd-DOTA (− 4.2% and − 5.7%, P < 0.001) and were confirmed by simulations. For focal nodular hyperplasia lesions (n = 5) Dfast and ffast increased (P < 0.001) with increasing Rlate, whereas for hepatocellular carcinoma (n = 4) and adenoma (n = 7) no differences were found.ConclusionMicroperfusion measured by IVIM reflects perfusion in a way resembling CE-MRI. Also IVIM separated intra- and extracellular MR contrast media. This underlines the potential of IVIM in quantitative liver imaging.  相似文献   

8.
ObjectivesWe investigated changes in the optic tract and optic radiation in patients with multiple sclerosis (MS) by comparing unilateral and bilateral optic nerve damage assessed based on visual evoked potentials (VEPs) using advanced diffusion MR metrics.MethodsIn 21 MS patients, diffusion MRI was performed. Maps of fractional anisotropy, apparent diffusion coefficient (ADC), and mean kurtosis (MK) were computed. On the basis of the P100 latency in VEPs, the MS patients were divided into three groups: bilateral (n = 7), unilateral (n = 7), and no abnormality (n = 7). Their optic tracts and optic radiations were analyzed with diffusion MRI-based fiber tracking. We also investigated the correlations between diffusion parameters and VEPs (n = 21).ResultsIn the optic tract, the diffusion changes in each of the three groups showed step-like changes. The diffusion changes in the optic radiations of the unilateral group were similar to those in the normal VEP group. Only the bilateral group showed significantly higher ADC and lower MK relative to the other two groups (P < 0.05, Steel–Dwass multiple-comparison test). A significant positive correlation between VEP latency and ADC and a significant negative correlation between VEP latency and MK were observed (P < 0.01, Spearman's correction).ConclusionsWe first evaluated the relationship between VEPs and DKI and concluded that the lateral geniculate nucleus may compensate for unilateral damage in the pre-geniculate optic pathway via neural plasticity.  相似文献   

9.
PurposeTo determine magnetic resonance elastography (MRE)-derived stiffness of pancreas in healthy volunteers with emphasis on: 1) short term and midterm repeatability; and 2) variance as a function of age.MethodsPancreatic MRE was performed on 22 healthy volunteers (age range:20–64 years) in a 3 T–scanner. For evaluation of reproducibility of stiffness estimates, the scans were repeated per volunteer on the same day (short term) and one month apart (midterm). MRE wave images were analyzed using 3D inversion to estimate the stiffness of overall pancreas and different anatomic regions (i.e., head, neck, body, and tail). Concordance and Spearman correlation tests were performed to determine reproducibility of stiffness measurements and relationship to age.ResultsA strong concordance correlation (ρc = 0.99; p-value < 0.001) was found between short term and midterm repeatability pancreatic stiffness measurements. Additionally, the pancreatic stiffness significantly increased with age with good Spearman correlation coefficient (all ρ > 0.81; p < 0.001). The older age group (> 45 yrs) had significantly higher stiffness compared to the younger group (≤ 45 yrs) (p < 0.001). No significant difference (p > 0.05) in stiffness measurements was observed between different anatomical regions of pancreas, except neck stiffness was slightly lower (p < 0.012) compared to head and overall pancreas at month 1.ConclusionMRE-derived pancreatic stiffness measurements are highly reproducible in the short and midterm and increase linearly with age in healthy volunteers. Further studies are needed to examine these effects in patients with various pancreatic diseases to understand potential clinical applications.  相似文献   

10.
ObjectivesWe validate a 4D strategy tailored for 3 T clinical systems to simultaneously quantify function and infarct size in wild type mice after ischemia/reperfusion, with improved spatial and temporal resolution by comparison to previous published protocols using clinical field MRI systems.MethodsC57BL/6J mice underwent 60 min ischemia/reperfusion (n = 14) or were controls without surgery (n = 6). Twenty-four hours after surgery mice were imaged with gadolinium injection and sacrificed for post-mortem MRI and histology with serum also taken for Troponin I levels. The double ECG- and respiratory-triggered 3D FLASH (Fast Low Angle Shot) gradient echo (GRE) cine sequence had an acquired isotropic resolution of 344 μm, TR/TE of 7.8/2.9 ms and acquisition time 25–35 min. The conventional 2D FLASH cine sequence had the same in-plane resolution of 344 μm, 1 mm slice thickness and TR/TE 11/5.4 ms for an acquisition time of 20–25 min plus 5 min for planning. Left ventricle (LV) and right ventricle (RV) volumes were measured and functional parameters compared 2D to 3D, left to right and for inter and intra observer reproducibility. MRI infarct volume was compared to histology.ResultsFor the function evaluation, the 3D cine outperformed 2D cine for spatial and temporal resolution. Protocol time for the two methods was equivalent (25–35 min). Flow artifacts were reduced (p = 0.008) and epi/endo-cardial delineation showed good intra and interobserver reproducibility. Paired t-test comparing ejection volume left to right showed no significant difference for 3D (p = 0.37), nor 2D (p = 0.30) and correlation slopes of left to right EV were 1.17 (R2 = 0.75) for 2D and 1.05 (R2 = 0.50) for 3D.Quantifiable ‘late gadolinium enhancement’ infarct volume was seen only with the 3D cine and correlated to histology (R2 = 0.89). Left ejection fraction and MRI-measured infarct volume correlated (R2 > 0.3).ConclusionsThe 4D strategy, with contrast injection, was validated in mice for function and infarct quantification from a single scan with minimal slice planning.  相似文献   

11.
BackgroundPrevious studies have demonstrated a correlation between Expanded Disability Status Scale (EDSS) and Diffusion Tensor Imaging (DTI) metrics, but the conclusions were based on evaluations of the entire cervical spinal cord.ObjectivesThe purpose of this study was to quantify the FA and MD values in the spinal cord of NMO patients, separating the lesion sites from the preserved sites, which has not been previously preformed. In addition, we attempted to identify a correlation with EDSS.MethodsDTI was performed in 11 NMO patients and 11 healthy individuals using a 1.5-T MRI scanner. We measured the FA and MD at ROIs positioned along the cervical spinal cord. The mean values of FA and MD at lesion, preserved and spinal cord sites were compared with those of a control group. We tested the correlations between the mean FA and MD with EDSS.ResultsFA in NMO patients was significantly reduced in lesion sites (0.44 vs. 0.55, p = 0.0046), preserved sites (0.46 vs. 0.55, p = 0.0015), and all sites (0.45 vs 0.55, p = 0.0013) while MD increased only in lesion sites (1.03 × 10 3 mm2/s vs. 0.90 × 10 3 mm2/s, p = 0.009). The FA demonstrated the best correlation with EDSS (r =  0.7603, p = 0.0086), particularly at lesion sites.ConclusionsThe results reinforce the importance of the FA index and confirm the hypothesis that NMO is a diffuse disease.  相似文献   

12.
AimTo assess the value of callosal morphological and microstructural integrity in assessing different cognitive domains, fatigue and depression in mildly disabled multiple sclerosis (MS) patients.Materials and methodsWe assessed 29 mildly disabled MS patients and 15 healthy controls using 3T magnetic resonance images (T1-weighted, FLAIR and DTI) and neuropsychological tests assessing different cognitive functions, depression and fatigue. We compared the added value of morphological measures (corpus callosum area corrected for total intracranial volume, index, circularity and the more detailed thickness profile) and diffusion features (fractional anisotropy and mean diffusivity) in multilinear models including standard clinical and whole-brain parameters in assessing neuropsychological scores.ResultsEven in mildly disabled MS patients, a significant reduction of the corpus callosum (p < 0.001) was observed in comparison to healthy controls. Callosal area, index and circularity were significantly (p < 0.002) related to whole-brain white matter volume, T2 lesion load and deep grey matter volume, but not with cortical grey matter.The combination of commonly used imaging and clinical parameters explained between 7% (Fatigue) and 50% (processing speed, verbal memory) of the adjusted variance. Inclusion of the mean diffusivity increased the adjusted R2 significantly to 69% (p = 0.004) and 71% (p = 0.002) for visuospatial and verbal memory respectively.ConclusionOur results show that callosal features may be used as an alternative to measuring whole-brain volumes. Furthermore, the microstructural integrity of the corpus callosum can help to predict an MS patient's memory performance.  相似文献   

13.
PurposeTo investigate biexponential apparent diffusion parameters of prostate central gland (CG) cancer, stromal hyperplasia (SH), and glandular hyperplasia (GH) and compare with monoexponential apparent diffusion coefficient (ADC) value for discriminating prostate cancer from benign hyperplasia.Materials and MethodsTwenty-one CG cancer foci, 23 SH and 26 GH nodules in the CG were analyzed in 39 patients (19 with CG cancer, 20 with peripheral zone cancer but no CG cancer) who underwent preoperative conventional DWI (b-value 0, 1000 s/mm2) and a 10 b-value (range 0 to 3000 s/mm2) DWI. All of the cancer and hyperplastic foci on MR images were localized on the basis of histopathologic correlation. The ADC value of the monoexponential DWI, and the fast apparent diffusion coefficient (ADCf), slow apparent diffusion coefficient (ADCs) value and the fraction of ADCf (f) of the biexponential DWI were calculated for all of the lesions. Receiver operating characteristic (ROC) analysis was performed for the differentiation of CG cancer from SH and GH.ResultsThe ADC values (× 10? 3 mm2/s) were 0.87 ± 0.11, 1.06 ± 0.15, and 1.61 ± 0.27 in CG cancer, SH and GH foci, respectively, and differed significantly, yielding areas under the ROC curve (AUCs) of 1.00 and 0.80 for the differentiation of carcinoma from GH and SH, respectively. The ADCf (× 10? 3 mm2/s), ADCs (× 10? 3 mm2/s) and f for cancer were 1.92 ± 0.38, 0.53 ± 0.17, and 47.7 ± 6.1%, respectively, which were lower than the same values for GH (3.43 ± 0.65, 1.12 ± 0.21, 61.1 ± 8.7%) (all p < 0.01). The ADCf and ADCs for cancer were also lower than those for SH (3.11 ± 0.30, 0.79 ± 0.21) (all p < 0.01). The ADCf yielded AUCs (1.00, p > 0.01) that were comparable to those from ADC for the differentiation of cancer from GH, while ADCf yielded higher AUCs (0.92) compared with ADC (p < 0.01) for the differentiation of cancer from SH. ADCs and f revealed AUCs of 0.97 and 0.90, respectively, for the differentiation of cancer from GH, and the ADCs offered relatively lower AUCs (0.68) for differentiating cancer from SH.ConclusionBiexponential DWI could potentially improve the differentiation of prostate cancer in CG, and the ADCf of the biexponential model offers better accuracy than ADC.  相似文献   

14.
Among the subfamilies of Chrysomelidae, Cassidinae sensu lato (s.l.) includes 6000 species distributed in 43 tribes. Approximately 100 of these species were cytogenetically analyzed and most of them presented 2n = 18 = 16 + Xyp, which was smaller than 2n = 20 = 18 + Xyp considered basal for Polyphaga. However, some groups of species presented maintenance of the basal diploid number and others showed increase in this number. Certain species of the latter group also exhibited variation in the type of sex chromosome system (SCS). Considering the recent taxonomic revision accomplished for the Cassidinae s.l. species, the existence of phylogenetic relationship for some species of this subfamily, the high diversity of species of this group in the Neotropical region, and the low number of Cassidinae s.l. species karyotyped so far, the aim of the present work was to establish the main mechanisms involved in the karyotype evolution of this subfamily through the study of seven species of the Brazilian fauna and overview of the cytogenetic data. The individuals were collected in southeast and south of Brazil. The chromosomal preparations obtained from embryo and testes of adult males were stained with Giemsa solution. The species Agroiconota inedita (2n = 42 = 40 + Xyp), Charidotella (s.str.) immaculata (2n = 22 = 20 + Xyp), Charidotella (s.str.) sexpunctata (2n = 22 = 20 + Xyp), and Stolas chalybaea (2n = 24 = 22 + Xyp) revealed diploid number higher than that established as basal for Polyphaga and biarmed chromosomes. The karyotype of Cteisella confusa, Deloyala cruciata, and Metriona elatior showed the chromosomal formulae 2n = 18 = 16 + Xyp considered modal for Cassidinae s.l. and biarmed chromosomes. The seven species exhibited easily identified sex chromosomes due to their size and/or morphology. The analysis of meiotic cells of all the species showed pachytenes with a positively heteropycnotic block probably corresponding to the sex chromosomes; diplotenes with a high number of bivalents with two chiasmata and sex chromosomes in a parachute configuration, and metaphases II that confirmed the chromosomal morphology, the type of SCS, and the regular segregation of all chromosomes. The data regarding to the number and morphology of the chromosomes, their behaviour during meiosis, and type of SCS were inedit for the majority of these species. In relation to the all Cassidinae s.l. species that presented SCS of the Xyp type, A. inedita was that with the highest diploid number. Furthermore, this work reported for the first time the cytogenetic information of representatives of the genera Cteisella and Metriona. Taking into account the phylogenetic and cytogenetic data of Cassidinae s.l. species, the karyotype differentiation of this group seems to have occurred from the basal karyotype of Polyphaga by decrease in the chromosome number and subsequent increase in this number. Pericentric inversion, centric fusion and fission seem to have been the main mechanisms that promoted the evolution of the autosomes. However, in the sex chromosome evolution, the mechanisms involved were centric fission and/or chromosomal translocation.  相似文献   

15.
ObjectivesTo test the hypothesis that two-dimensional (2D) displacement encoding via stimulated echoes (DENSE) is a reproducible technique for the depiction of segmental myocardial motion in human subjects.Materials and methodsFollowing the approval of the institutional review board (IRB), 17 healthy volunteers without documented history of cardiovascular disease were recruited. For each participant, 2D DENSE were performed twice (at different days) and the images were obtained at basal, midventricular and apical levels of the left ventricle (LV) with a short-axis view. The radial thickening strain (Err), circumferential strain (Ecc), twist and torsion were calculated. The intra-, inter-observer and inter-study variations of DENSE-derived myocardial motion indices were evaluated using coefficient of variation (CoV) and intra-class correlation coefficient (ICC).ResultsIn total, there are 272 pairs of myocardial segments (data points) for comparison. There is good intra- and inter-observer reproducibility for all DENSE-derived measures in 17 participants. There is good inter-study reproducibility for peak Ecc (CoV = 19.64%, ICC = 0.8896, p < 0.001), twist (CoV = 33.11%, ICC = 0.9135, p < 0.001) and torsion (CoV = 13.96%, ICC = 0.8684, p < 0.001). There is moderate inter-study reproducibility for Err (CoV = 38.89%, ICC = 0.7022, p < 0.001).ConclusionDENSE is a reproducible technique for characterizing LV regional systolic myocardial motion on a per-segment basis in healthy volunteers.  相似文献   

16.
ObjectiveTo evaluate the value of enhanced T2 star-weighted angiography (ESWAN) in diagnosis and differential diagnosis of prostate cancer by comparing the multiple indices of ESWAN in benign prostatic hyperplasia (BPH), prostate cancer (PCa) and the normal peripheral zone (PZ).MethodsTraditional MRI and ESWAN were performed on forty-nine clinically-diagnosed PCa patients, sixty BPH patients, and forty-six normal adult males. The ESWAN indices (magnitude value, phase value, R2* value and T2* value) measured on different regions of interest (ROIs) were analyzed. Additionally, receiver operating characteristic (ROC) analysis was performed to obtain the area under the curve (AUC), sensitivity, specificity, and optimal cut-off points of PCa and BPH, PCa and PZ respectively.ResultsThe magnitude value, phase value, R2* value and T2* value of PZ were 1529.43 ± 254.43, 0.0689 ± 0.1619, 16.57 ± 8.11, 82.75 ± 53.87, respectively; the magnitude value, phase value, R2* value, and T2* value of PCa were 1540.18 ± 338.62, − 0.0176 ± 0.0919, 26.93 ± 11.31, and 45.99 ± 17.43, respectively; the magnitude value, phase value, R2* value, and T2* value of BPH were 1579.49 ± 285.28, 0.0209 ± 0.0839, 20.69 ± 3.95, and 51.56 ± 8.90, respectively. Compared with normal PZ, phase value of PCa was lower (t =  3.302, P = 0.001), R2* value higher (t = 5.326, P = 0.000), and T2* value lower (t =  4.570, P = 0.000); compared with BPH, phase value of PCa was lower (t =  2.261, P = 0.026), R2* value higher (t = 3.988, P = 0.000), and T2* value lower (t =  2.155, P = 0.033). When PCa and PZ were distinguished, the AUC of magnitude value, phase value, R2* value, and T2* value were respectively 0.539 (P = 0.510), 0.679 (P = 0.0007), 0.811 (P < 0.0001), and 0.762 (P < 0.0001); the diagnosis efficiency of R2* value was higher than that of T2* value (P = 0.037), while the diagnosis efficiency of T2* value was equivalent to phase value (P = 0.256). When PCa was differentiated from BPH, the AUC of magnitude value, phase value, R2* value, and T2* value were 0.518 (P = 0.752), 0.612 (P = 0.039), 0.705 (P = 0.0001), and 0.685 (P = 0.0006), respectively; there was no statistical difference in the diagnostic efficiency of phase value, R2* value, and T2* value.ConclusionsThe phase value, R2* value and T2* value can distinguish PCa and normal PZ, PCa and BPH, so they are valuable for the diagnosis and differential diagnosis of PCa, moreover, the diagnostic efficiency of R2* value is better than other indices.  相似文献   

17.
PurposeAim of this retrospective study was to compare diagnostic accuracy of proposed automatic normalization method to quantify the relative cerebral blood volume (rCBV) with existing contra-lateral region of interest (ROI) based CBV normalization method for glioma grading using T1-weighted dynamic contrast enhanced MRI (DCE-MRI).Material and methodsSixty patients with histologically confirmed gliomas were included in this study retrospectively. CBV maps were generated using T1-weighted DCE-MRI and are normalized by contralateral ROI based method (rCBV_contra), unaffected white matter (rCBV_WM) and unaffected gray matter (rCBV_GM), the latter two of these were generated automatically. An expert radiologist with > 10 years of experience in DCE-MRI and a non-expert with one year experience were used independently to measure rCBVs. Cutoff values for glioma grading were decided from ROC analysis. Agreement of histology with rCBV_WM, rCBV_GM and rCBV_contra respectively was studied using Kappa statistics and intra-class correlation coefficient (ICC).ResultThe diagnostic accuracy of glioma grading using the measured rCBV_contra by expert radiologist was found to be high (sensitivity = 1.00, specificity = 0.96, p < 0.001) compared to the non-expert user (sensitivity = 0.65, specificity = 0.78, p < 0.001). On the other hand, both the expert and non-expert user showed similar diagnostic accuracy for automatic rCBV_WM (sensitivity = 0.89, specificity = 0.87, p = 0.001) and rCBV_GM (sensitivity = 0.81, specificity = 0.78, p = 0.001) measures. Further, it was also observed that, contralateral based method by expert user showed highest agreement with histological grading of tumor (kappa = 0.96, agreement 98.33%, p < 0.001), however; automatic normalization method showed same percentage of agreement for both expert and non-expert user. rCBV_WM showed an agreement of 88.33% (kappa = 0.76,p < 0.001) with histopathological grading.ConclusionIt was inferred from this study that, in the absence of expert user, automated normalization of CBV using the proposed method could provide better diagnostic accuracy compared to the manual contralateral based approach.  相似文献   

18.
Currently several therapeutic applications of ultrasound in cancer treatment are under progress which uses cavitation phenomena to deliver their effects. There are several methods to evaluate cavitation activity such as chemical dosimetry and measurement of subharmonic signals. In this study, the cavitation activity induced by the ultrasound irradiation on exposure parameters has been measured by terephthalic acid chemical dosimetry and subharmonic analysis. Experiments were performed in the near 1 MHz fields in the progressive wave mode and effect of duty cycles changes with 2 W/cm2 intensity (ISATA) and acoustic intensity changes in continuous mode on both fluorescence intensity and subharmonic intensity were measured. The dependence between fluorescence intensity of terephthalic acid chemical dosimetry and subharmonic intensity analysis were analyzed by Pearson correlation (p-value < 0.05). It has been shown that the subharmonic intensity and the fluorescence intensity for continuous mode is higher than for pulsing mode (p-value < 0.05). Also results show that there is a significant difference between the subharmonic intensity and the fluorescence intensity with sonication intensity (p-value < 0.05). A significant correlation between the fluorescence intensity and subharmonic intensity at different duty cycles (R = 0.997, p-value < 0.05) and different intensities (R = 0.985, p-value < 0.05) were shown. The subharmonic intensity (μW/cm2) significantly correlated with the fluorescence intensity (count) (R = 0.901; p < 0.05) and the fluorescence intensity due to chemical dosimetry could be estimated with subharmonic intensity due to subharmonic spectrum analysis. It is concluded that there is dependence between terephthalic acid chemical dosimetry and subharmonic spectrum analysis to examine the acoustic cavitation activity.  相似文献   

19.
PurposeHepatic magnetic resonance elastography (MRE) is currently a breath-hold imaging technique. Patients with chronic liver disease can have comorbidities that limit their ability to breath-hold (BH) for the required acquisition time. Our aim was to evaluate whether stiffness measurements obtained from a navigator-triggered MRE acquisition are comparable to standard expiratory breath-hold, inspiratory breath-hold or free-breathing in healthy participants.Materials and methodsTwelve healthy participants were imaged using the four methods on a clinical 1.5 T MR system equipped with a product MRE system. Mean liver stiffness, and measurable area of stiffness (with a confidence threshold >95%) were compared between sequences using the concordance correlation coefficient. Repeatability of each sequence between two acquisitions was also assessed.ResultsThe standard BH expiratory technique had high concordance with the navigated technique (r = 0.716), and low concordance with the BH inspiration (r = 0.165) and free-breathing (r = 0.105) techniques. The navigator-triggered technique showed no statistical difference in measurable area of liver or in repeatability compared with the standard expiratory acquisition (p = 0.997 and p = 0.407 respectively). The free-breathing technique produced less measurable liver area and was less repeatable than the alternative techniques. The increase in acquisition time for navigator techniques was 3 min 6 s compared to standard expiratory breath-hold.ConclusionNavigator-based hepatic MRE measurements are comparable to the reference standard expiratory breath-hold acquisition in healthy participants.  相似文献   

20.
IntroductionWheelchair Users (WCUs) depend on their upper extremities for their daily living. Therefore, it is not unusual to find that shoulder pain (SP) is a problem for WCUs and reduces their participation in sport and leisure activities.ObjectivesThe aims of this study were 1 – to analyse skin temperature measured by infrared thermography (IRT) before (pre-test), one minute after (post-test) and 10 min after (post-10) the kinematic wheelchair propulsion test (T-CIDIF) of athletic wheelchair users; 2 – to evaluate the relationship between shoulder pain (SP) and Skin Temperature Asymmetry (ΔTsk) before and after (pre-test, post-test, post-10) the T-CIDIF, and to relate the SP with the kinematic variables of the T-CIDIF.Participants & interventions/procedureA volunteer sample of 12 wheelchair athletes completed an exercise test (T-CIDIF) in their own wheelchair. It consisted in a 30-s maximum test performed on two rollers. Two linear transducers connected to the rollers registered the number of propulsions, maximum and mean velocity and power of each arm. SP was assessed with the Wheelchair Users Shoulder Pain Index (WUSPI). Skin temperature (Tsk) of the anterior and posterior upper body was measured before and after the T-CIDIF by using an infrared camera. A total of 26 ROIs were evaluated with respect to the opposite side of the body to identify significant (ΔTsk).Results/main outcome measure(s)Significant differences were observed between the Tsk of the post-10 and pre-test in 12 ROIs, and between the post-10 and the post-test in most of the ROIs. These differences are attenuated when the ΔTsk is compared before and after exercise. Tsk tends to initially decrease immediately after the test and then significantly increase after 10 min of completing the T-CIDIF. The ΔTsk vs SP analysis yielded significant inverse relationships (from r = −0.58 to r = −0.71, p < 0.05) in 5 of the 26 ROI. No significant correlations between propulsion variables and SP questionnaire were found. All T-CIDIF variables were significantly correlated with the temperature asymmetries in multiple ROIs (from r = −0.86 to r = −0.58, from p < 0.05 to p < 0.001).ConclusionsThese results present indications that high performance wheelchair athletes exhibit similar capacity of heat production than able-bodied. The thermographic data inversely correlates with the SP and the kinematic variables, but the last is not related to SP. This work contributes to improve the understanding about temperature changes in wheelchair athletes during exercise, and could be used to assess the efficacy of various sports and rehabilitation programs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号