首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The LB 1000-PW detector is mainly used for determining total alpha, beta and gamma activity of low activity natural sources such as water, soil, air filters and any other environmental sources. Detector efficiency needs to be known in order to measure the absolute activity of such samples. This paper presents results on the total gamma counting efficiency of a Phoswich detector from point and disk sources. The directions of photons emitted from the source were determined by Monte Carlo techniques and the true path lengths in the detector were determined by analytical equations depending on photon directions. Results are tabulated for various gamma energies.  相似文献   

2.
The coherent (Rayleigh) to incoherent (Compton) scattering cross-section ratio of elements, in the range 6 ≤ Z ≤ 82, are determined experimentally for 145 keV incident gamma photons. An HPGe (High purity germanium) semiconductor detector is employed, at scattering angle of 50°, 70° and 90°, to record the spectra originating from interactions of incident gamma photons with the target under investigation. The intensity ratio of Rayleigh to Compton scattered peaks observed in the recorded spectra, and corrected for photo-peak efficiency of gamma detector and absorption of photons in the target and air, along with the other required parameters provides the differential cross-section ratio. The measured values of cross-section ratio are found to agree with theoretical predictions (corresponding to 4.939, 6.704 and 8.264 Å−1 photon momentum transfer) based upon non-relativistic form factor, relativistic form factor, modified form factor and S-matrix theory.  相似文献   

3.
A scintillation counting system has been constructed with the use of BC-400 and EJ-212 series plastic scintillators along with a subminiature photomultiplier tube to investigate the effect of increasing plastic scintillator thickness on system-integrated counts. Measurements have been carried out using four different gamma sources with different energies ranging from 6 keV to 1.332 MeV and a Ni-63 beta source with a maximum energy of 66 keV. Scintillator thicknesses ranged from 10 μm to 2500 μm. The response of the system was determined by measuring the integrated counts as a function of scintillator thickness. These experimental findings were used to empirically determine the optimum thickness of scintillator material with which to build a low energy beta detector which discriminates against high energy gamma photons in a mixed radiation field environment.  相似文献   

4.
Target photons mixed in the 144, 250 and 565 keV mono-energetic neutron calibration fields were measured using a cylindrical NaI(Tl) detector with 7.62 cm both in diameter and in length. The ambient dose equivalent H*(10) of the photons was evaluated by applying the “G(E) function” to the measured pulse height spectrum. Neutrons induce photons by nuclear reactions in the NaI(Tl) detector and affect the pulse height spectrum. In order to eliminate the influence of these neutron events, the time-of-flight technique was applied with operating the accelerator in the pulse mode. The ratios by the ambient dose equivalent H*(10) of the photons to the 144, 250 and 565 keV neutrons were evaluated to be 3.3%, 4.7% and 0.9%, respectively. Although high energy photons ranging from 6 to 7 MeV are emitted by the 19F(p,αγ)16O reactions, the dose of the target photons is low enough to calibrate neutron dosemeters except for ones with high sensitivity to the photons.  相似文献   

5.
In the course of this work, the experimental energy dependence of the OSL material beryllium oxide was determined for different radiation qualities. With the help of the radiation transport program AMOS the experimental setup was simulated. The calculated energy response differs from the experimental energy response. There is an underestimation for low energy photons caused by local saturation effects. For radiation with higher LET local structures of the detector can be saturated. The deposited energy doesn't contribute to the OSL effect. The detected dose is lower. The ratio between experimental and simulated energy response is called OSL efficiency. Subsequently the results were used to generate a model of local saturation for calculating the efficiency for different irradiation conditions. With the help of the model predictions for the detection efficiency for photons and electrons in the common energy range for personal and environmental dosimetry, reaching from 10 keV up to some MeV, are possible. The efficiency for electrons decreases with falling energy continuously. Photons show a similar effect, but for energies ranging from 40 to 80 keV the efficiency increases with decreasing energy. This can be explained by the interaction effects of the photons with the detector material. The experimental and modeled detection efficiencies can be used to calculate the readout of a BeO-OSL detector from dose values determined with radiation transport programs.  相似文献   

6.
Results of continuous spectral monitoring of indoor gamma background are reported for seismological application in one fault zone of the Western Caucasus. Background count rates were recorded every 5 min since 2004. Two detectors (a scintillation crystal CsI(Tl), 200 mm × 150 mm in a low background metal screen and a NaI(Tl) detector, 90 mm × 90 mm outside of the screen) were used. Various intervals of energy of gamma rays, for example, (2.50–3.40) MeV, (1.70–2.00) MeV, (1.35–1.55) MeV and others were analyzed. Averages for all measurements as well as seasonal and hourly changes of count rate of detectors were obtained. As an example, for the interval (1.70–2.00) MeV a minimal monthly count rate of detector CsI(Tl) was observed in June, and the maximal monthly count rate of detector NaI(Tl) was observed in July. Factors of correlation between different intervals of energy of gamma rays were also investigated. Strong changes of annual, monthly and daily factors were obtained.In each daily curve of all intervals of energy of gamma rays, the first Fourier harmonic was calculated. The deviations from 3σ (“splash”), which are upward or downward from the first harmonic, were compared with the seismological data. It was possible to correlate the low background dates of “splashes” with the dates of regional earthquakes through 9 ± 1 days.Change of ratio of count rate in different intervals of energy of gamma rays can be used to study processes of preparation of earthquakes.The factor of correlations between intervals (2.50–3.40) MeV and (1.70–2.00) MeV increased to almost 1.00 close to earthquakes. This effect was obtained in low background screen.Connection of the gamma data with the meteorological data was not obtained.  相似文献   

7.
The tabletop synchrotron light sources MIRRORCLE‐6X and MIRRORCLE‐20SX, operating at electron energies Eel = 6 MeV and Eel = 20 MeV, respectively, can emit powerful transition radiation (TR) in the extreme ultraviolet (EUV) and the soft X‐ray regions. To clarify the applicability of these soft X‐ray and EUV sources, the total TR power has been determined. A TR experiment was performed using a 385 nm‐thick Al foil target in MIRRORCLE‐6X. The angular distribution of the emitted power was measured using a detector assembly based on an NE102 scintillator, an optical bundle and a photomultiplier. The maximal measured total TR power for MIRRORCLE‐6X is Pmax? 2.95 mW at full power operation. Introduction of an analytical expression for the lifetime of the electron beam allows calculation of the emitted TR power by a tabletop synchrotron light source. Using the above measurement result, and the theoretically determined ratio between the TR power for MIRRORCLE‐6X and MIRRORCLE‐20SX, the total TR power for MIRRORCLE‐20SX can be obtained. The one‐foil TR target thickness is optimized for the 20 MeV electron energy. Pmax? 810 mW for MIRRORCLE‐20SX is obtained with a single foil of 240 nm‐thick Be target. The emitted bremsstrahlung is negligible with respect to the emitted TR for optimized TR targets. From a theoretically known TR spectrum it is concluded that MIRRORCLE‐20SX can emit 150 mW of photons with E > 500 eV, which makes it applicable as a source for performing X‐ray lithography. The average wavelength, = 13.6 nm, of the TR emission of MIRRORCLE‐20SX, with a 200 nm Al target, could provide of the order of 1 W EUV.  相似文献   

8.
It is an on-going challenge to verify the proton range in situ during proton therapy. Since the protons stop in target tissue, measurement of gamma-rays emitted either promptly from nuclear de-excitation or in pair from positron annihilation is the feasible method to monitor the proton range in-vivo. Using the technique of gamma collimation, we empirically demonstrated that the proton range and prompt gamma distribution are well correlated in the therapy energy range, and that measuring prompt gammas is a viable method for the clinical application. However, this collimation technique appears not to be applicable to passively scattered proton beams. The device chosen for gamma imaging in 2D is an electron tracking Compton camera, which images single-emission photons employing a gas chamber to induce Compton scattering. Images of prompt gammas were attained at the proton beam energy of 140 MeV. Measurements showed that gamma image in the energy range of 800-2000 keV provides a better match with the proton range compared to the image by lower energy gammas.  相似文献   

9.
《Radiation measurements》2007,42(2):256-262
The doubly differential collision cross-sections of the double-photon Compton process have been measured experimentally for 0.662 MeV incident gamma photons. The measurements are carried out using a single gamma detector, a technique avoiding the use of the complicated slow–fast coincidence set-up used till now for observing this higher order QED process. The energy spectra of detected photons are observed as a long tail to the single-photon Compton line on the lower side of the full energy peak in the recorded scattered energy spectrum. The measured values of the cross-section for different independent energy levels of one of the two final photons are of the same magnitude but show deviation from the corresponding values obtained from the theory. However, the present measurements are first of its kind and in view of the nature and order of deviations, the agreement of measured values with theory is quite satisfactory.  相似文献   

10.
The angular distribution of nucleons emitted in the 12C(γ,pn) reaction has been measured using tagged photons at the Mainz microtron MAMI. The variation of the reaction strength with the polar angles of the two emitted nucleons is reported for Eγ=120−150 MeV. The proton angular distribution peaks at more backward angles than the 2H(γ,p) differential cross section indicating a departure from the simple quasi-deuteron model of 2N photo-emission. The distribution shape is in reasonable agreement with microscopic theoretical models which include both π- and ρ-exchange. Received: 3 September 1997 / Revised version: 17 December 1997  相似文献   

11.
The objective of present experiment is to assign effective atomic number (Zeff) to samples of scientific interest (oxides of lanthanoids, also called rare earths, and alloys of lead and tin of known composition) and to measure stable iodine content of tissue (biological sample). An HPGe semiconductor detector, placed at 70° to the incident beam, detects gamma photons scattered from the sample under investigation. The experiment is performed on various elements with atomic number satisfying, 6 ≤ Z ≤ 82, for 145 keV incident photons. The intensity ratio of Rayleigh to Compton scattered peaks, corrected for photo-peak efficiency of gamma detector and absorption of photons in the sample and air, is plotted as a function of atomic number and constituted a fit curve. From this fit curve, the respective effective atomic numbers of the scientific samples are determined. The agreement of measured values of Zeff with theoretical calculations is found to be quite satisfactory. The measured intensity ratio from phantom (KI solutions, simulating thyroid content of stable iodine) varies linearly with KI concentration and provides stable iodine content of tissue.  相似文献   

12.
An alumina-silica glass cylinder with cerium-activated gadolinium bromide, 2.5 cm in diameter and 3 cm long was cast to form a scintillation detector for spectral analysis of nuclear radiation, especially gamma rays. The detector, operated with a conventional photomultiplier tube and associated power supply, amplifier, and multichannel analyzer, shows for the first time for this material system a set of spectra that include well-defined full-energy gamma-ray peaks from 59.5 keV to 2500 keV. The full-energy peaks were characterized in terms of pulse height linearity, resolution, and counting efficiency. Energy spectral resolution also was demonstrated for alpha particles, beta particles, and 239Pu/Be neutrons. Gamma-ray detection efficiency was comparable to a conventional NaI(Tl) detector of similar volume but peak resolution at 662 keV in this new detector type was currently only 27%, compared to about 7% for the NaI(Tl) detector. Improved light output and thus resolution is being sought by optimizing glass compositions and processing.  相似文献   

13.
New details of a well-known physical process—cascade transition—have been considered. The wave function of a system of two photons emitted in a cascade transition in the absence of a shift of the phase of the intermediate state was studied. The joint energy distribution density for two such photons is obtained by numerical calculation, and a correlation between their energies at certain probabilities of radiative transitions is ascertained. This phenomenon can be used to diagnose the plasma density.  相似文献   

14.
A new long counter has been constructed and calibrated with the inherent efficiency of 11.5 cm2 in the 2.5 MeV neutron field, and a relative flat energy response of 20% disparity within 0.5 MeV–15 MeV. Using this detector and another commercial DePangher counter, the departure of “point” assumption at near distance and the scattering background influence are investigated by performing three groups of experiments in low, middle and high scattering room. Simulation studies are also performed to supplement the experimental data.Two conclusions are deduced. First, the direct efficiency η is very sensitive when the source is very near, and the departure of point assumption is very evident at this situation. So, a revising method is tried to put forward, employing the on-site calibration with a known neutron source and theoretical calculated coefficient D = (η/ε)/(ηcf252cf252). And second, scattering backing counts are found mainly from the nearest wall or scatterers. However, the relatively uniform isotropic scattered neutrons contribute insensitive to the source-detector distance, which means the background tally can be eliminated by some simple ways.  相似文献   

15.
Chen XH  Zhai YH  Zhang D  Wu LA 《Optics letters》2006,31(16):2441-2443
Single-photon detectors are finding increasingly wide application in all branches of science and technology thus a precise knowledge of their quantum efficiency is an essential prerequisite. We have performed the first proof-of-principle demonstration of a means to determine the quantum efficiency by which no second detector or reference standard is required. This absolute self-calibration method is based on the time correlation of entangled photons pairs emitted in spontaneous parametric down conversion. The measured quantum efficiency of a Si avalanche photodiode single-photon detector agrees well with the product specifications.  相似文献   

16.
采用蒙特卡罗程序MCNP建立物理模型,对井型高纯锗探测器的效率进行虚拟刻度。模拟计算在密度为0.4,1.2 gcm-3的6种不同成分环境样品中,探测器对射线的探测效率,当能量高于0.10 MeV时,体源样品的探测效率主要与样品密度、射线能量相关。以土壤、水和植物油样品为代表,结合所选取的函数模型,确定了密度范围0.1~1.6 gcm-3的固体源、密度1.0 gcm-3的水溶液和密度0.92 gcm-3的油溶液体源的效率函数及参数。实验采用标准源,对探测效率模拟结果进行了验证,探测效率的模拟值与实验值符合较好,二者误差均在3%以内。说明MCNP程序可以较为准确地模拟计算井型高纯锗探测器对射线的探测效率,验证了该无源效率刻度方法的准确性和可行性。  相似文献   

17.
低能D(d,γ)4He辐射俘获反应截面的研究在聚变领域和天体物理等领域中起到非常重要的作用。由于受到标准γ源能量的制约,在研究D(d,γ)4He反应高能γ射线产额实验过程中不能用标准源进行效率刻度。采用实验测量与计算相结合的方法实现NaI探测器对23.8 MeV γ射线的效率刻度,先对6.13MeVγ射线效率进行实验刻度,然后用蒙卡程序MCNP-4C模拟计算出NaI探测器的效率曲线,再用实验数据与模拟结果进行对比校正,计算出NaI探测器在23.8MeV能量点对γ射线的探测效率。该方法对高能γ射线效率刻度给出了一种参考依据。In the study of D(d,γ)4He radiative capture reactions research, which is very important for fusion and astrophysics, the efficiency calibration of the detector is necessary. Due to the restriction on energy of the standard gamma source, the efficiency calibration of high-energy gamma-rays can not be calibrated by a standard source. In this paper, the method combining the experimental measurements and calculations for the efficiency calibrations of high energy gamma rays is given in the experiment of 6.13MeV gamma rays efficiency calibration using NaI detector, the efficiency curve of which is calculated by MCNP-4C and corrected experimentally. In this case, the detection efficiency of 23.8MeV gamma ray is known. The method provides a reference to high energy gamma ray efficiency calibration.  相似文献   

18.
The scattering and absorption differential cross sections for nonlinear QED process such as double photon Compton scattering have been measured as a function of independent final photon energy. The incident gamma photons are of 0.662 MeV in energy as produced by an 8 Ci137Cs radioactive source and thin aluminum foils are used as scatterer. The two simultaneously emitted photons in this process are detected in coincidence using two Nal(T1) scintillation detectors and a slow-fast coincidence set-up of 30 nsec resolving time. The measured values of scattering and absorption differential cross sections agree with theory within experimental estimated error.  相似文献   

19.
The available experimental data on the relative thermoluminescent efficiency of the LiF:Mg,Ti dosimetric peaks for protons are contradictory. There are several reports showing that the efficiency exceeds unity by even more than 30%, however, many others show the efficiency close to unity or even lower. These contradictory data might be a result of the real variability of TLD properties or of not perfectly reproduced experimental conditions.In an attempt to resolve this issue, the efficiency of 16 batches of LiF:Mg,Ti (MTS) detectors for 60 MeV protons produced at the IFJ Kraków over the last 20 years was measured. All values of the relative TL efficiency were found to exceed unity significantly, with an average of 1.09. Dispersion between different batches was very low, all data were within 4% of the mean value.In second part of experiment the dependence of the relative efficiency of LiF:Mg,Ti and LiF:Mg,Cu,P detectors on proton energy was determined. The efficiency for LiF:Mg,Ti dosimetric peaks was found to have a maximum of 1.20 at about 20 MeV. For LiF:Mg,Cu,P the relative efficiency decreases systematically with decreasing proton energy, from 0.96 at 56 MeV, to 0.61 at 11 MeV.  相似文献   

20.
This paper presents a method for a small, inexpensive mobile robot equipped with a single high resolution scintillation detector to quickly survey an area and convey information about local sources of gamma radiation to a remote human operator. This is achieved by surrounding the detector with a lead sheath that blocks all gamma-rays except those incident along the detector's axial direction. A 180° horizontal scan is performed by rotating the detector and a directional profile of gamma radiation is constructed. In addition, a 180° visual panorama of the local area is assembled using a camera mounted on the detector. A plot of the detector count rate versus angle is then overlaid on top of the visual panorama and visible peaks clearly indicate the direction of local gamma radiation sources. Measuring the energy spectrum of gamma-rays in each direction produces a 2D count frequency histogram where distinct peaks indicate the energy and direction of local gamma-ray sources allowing the identification of different radio-isotopes. The mobile robot can use the peaks as goal directions and autonomously move towards gamma-ray sources.  相似文献   