首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The paper proposes a readout circuit architecture with adjustable integration time for dual-band infrared detectors. The readout circuit uses direct injection to be combined with a capacitive trans-impedance amplifier. The amplifier is sharing between two pixels to reduce the complexity of the readout circuit. The proposed device reduces power consumption and area overhead compared to traditional structures. An experimental chip was fabricated using the TSMC 0.35 μm 2P4 M 5 V process. The resulting unit pixel layout area is 40 μm × 40 μm with input photocurrent ranging from 0.11 pA to 50 nA. CTIA mode is applicable from 0.11 pA to 10 nA, while DI mode is applicable from 3.3 pA to 50 nA. The maximum operating frequency of the chip are 4 MHz. The CTIA output swing is 1.2 V, the DI output swing is 2 V. The signal to noise ratio of the readout circuit is 65 dB and power consumption is less than 9.6 mW.  相似文献   

2.
A monolithic silicon CMOS optoelectronic integrated circuit (OEIC) is designed and fabricated using standard 0.35-μm CMOS technology. This OEIC monolithically integrates light emitting diode (LED), silicon dioxide waveguide, photodetector and receiver circuit on a single silicon chip. The silicon LED operates in reverse breakdown mode and can emit light at 8.5 V. The output optical power is 31.2 nW under 9.8 V reverse bias. The measured spectrum of LED showed two peaks at 760 nm and 810 nm, respectively. The waveguide is composed of silicon dioxide/metal multiple layers. The responsivity of the n-well/p-substrate diode photodetector is 0.42 A/W and the dark current is 7.8 pA. The LED-emitted light transmits through the waveguide and can be detected by the photodetector. Experimental results show that on-chip optical interconnects are achieved by standard CMOS technology successfully.  相似文献   

3.
FLIR Systems, Inc. has designed and fabricated the ISC0501 CMOS readout integrated circuit (ROIC) for quantum well infrared photodetectors (QWIPs). The ISC0501 is a two-color 1024 × 1024 format array with a 30 μm pixel pitch. The ROIC contains a separate analog signal path for each wavelength band. Separate signal paths allow the two-colors to have optimized detector biases, integration times, offsets and gains. This architecture also allows both colors to simultaneously sample a scene and readout the pixel data. This paper will describe the interface, design and features of the ROIC as well as a summary of the characterization test results. A sample image is included from a focal plane array (FPA) built by the Jet Propulsion Laboratory (JPL) using the ISC0501 ROIC with QWIP detectors designed by JPL.  相似文献   

4.
This paper presents a digital readout integrated circuit (DROIC) implementing time delay and integration (TDI) for scanning type infrared focal plane arrays (IRFPAs) with a charge handling capacity of 44.8 Me while achieving quantization noise of 198 e and power consumption of 14.35 mW. Conventional pulse frequency modulation (PFM) method is supported by a single slope ramp ADC technique to have a very low quantization noise together with a low power consumption. The proposed digital TDI ROIC converts the photocurrent into digital domain in two phases; in the first phase, most significant bits (MSBs) are generated by the conventional PFM technique in the charge domain, while in the second phase least significant bits (LSBs) are generated by a single slope ramp ADC in the time domain. A 90 × 8 prototype has been fabricated and verified, showing a significantly improved signal-to-noise ratio (SNR) of 51 dB for low illumination levels (280,000 collected electrons), which is attributed to the TDI implementation method and very low quantization noise due to the single slope ADC implemented for LSBs. Proposed digital TDI ROIC proves the benefit of digital readouts for scanning arrays enabling smaller pixel pitches, better SNR for the low illumination levels and lower power consumption compared to analog TDI readouts for scanning arrays.  相似文献   

5.
A series of sulfonated poly(2,6-dimethyl-1,4-phenylene oxide) (S-PPO) and sulfonated poly(ether ether ketone) (S-PEEK) at various sulfonation degrees were prepared and characterized for their degree of sulfonation, water uptake, ion exchange capacity, proton conductivity and methanol permeability. Based on the obtained results, the optimum samples were determined and subsequently blended together at different compositions. A single glass transition temperature (Tg) was determined for all blend samples, which was attributed to the presence of sulfonate groups on polymer backbones resulting in the formation of electrostatic cross-linking besides phenyl–phenyl interactions. Moreover, the molecular level of mixing in blends was verified through WAXS patterns. According to the membrane selectivity and hydrolytic stability measurements, 75 wt.% of S-PPO and 25 wt.% of S-PEEK was selected as the optimum composition. Afterwards, different amounts of an organically modified montmorillonite (MMT) were incorporated into the predetermined optimum composition matrices to reduce the methanol permeability of the resulted nanocomposite proton exchange membranes. The XRD patterns of nanocomposites revealed the exfoliated microstructure of the clay nanolayers in the polymeric matrices. Transport property measurements of nanohybrid membranes showed that the maximum selectivity parameter of 75 wt.% S-PPO/25 wt.% S-PEEK composition appeared in the presence of 1.5 wt.% of MMT, which is 1.53 times higher than the corresponding value for Nafion® 117. The DMFC single cell test of the optimum nanohybrids membrane at 5 M methanol feed showed an open circuit voltage of 0.77 V and maximum power density of 135 mW cm? 2 in comparison with 0.67 V and 108 mW cm? 2 for Nafion® 117, respectively. Fabricated nanohybrid membranes, thanks to their high selectivity, desirable transport properties and tenability, could be considered as promising polyelectrolytes for direct methanol fuel cell applications.  相似文献   

6.
A hybrid advanced oxidation process combining sonochemistry (US) and electrochemistry (EC) for the batch scale degradation of ibuprofen was developed. The performance of this hybrid reactor system was evaluated by quantifying on the degradation of ibuprofen under the variation in electrolytes, frequency, applied voltage, ultrasonic power density and temperature in aqueous solutions with a platinum electrode. Among the methods examined (US, EC and US/EC), the hybrid method US/EC resulted 89.32%, 81.85% and 88.7% degradations while using NaOH, H2SO4 and deionized water (DI), respectively, with a constant electrical voltages of 30 V, an ultrasound frequency of 1000 kHz, and a power density of 100 W L−1 at 298 K in 1 h. The degradation was established to follow pseudo first order kinetics. In addition, energy consumption and energy efficiencies were also calculated. The probable mechanism for the anodic oxidation of ibuprofen at a platinum electrode was also postulated.  相似文献   

7.
Future astronomical instruments call for large format and high sensitivity far infrared focal-plane arrays to meet their science objectives. Arrays as large as 128 × 128 with sensitivities equal to or better than 10−18 W/√Hz are set as targets for the far IR instruments to be developed within the next 10 years. These seemingly modest goals present a not-so-modest quantum leap for far IR detector technology whose progress is hampered by a number of complexities; chief among them the development of low noise readouts operating at deep cryogenic temperatures and a viable hybridization scheme suitable for far IR detectors. In an effort to incrementally develop large-format photoconductor arrays, we have fabricated a 2 × 16 Ge:Sb array using the SBRC190 readout – a cryogenic 1 × 32 CTIA readout multiplexer initially developed for SOFIA’s AIRES instrument. In this paper we report the results of the extensive parametric tests performed on this array showing an impressive noise performance of 2.2 × 10−18 W/√Hz and a DQE of 0.41 despite some design limitations. With such an encouraging performance, this prototype array will serve as a platform for our future developmental effort.  相似文献   

8.
Simultaneous direct irradiation with microwaves and ultrasound was used to determine total Kjeldahl nitrogen. The method involves chemical digestion in two steps, mineralization with sulfuric acid and oxidation with H2O2. The most influential variables for the microwave/ultrasound (MW/US)-assisted digestion were optimized using tryptophan as the model substance. The optimum conditions were: H2SO4 volume, 10 mL; H2O2 volume, 5 mL; weight of sample, 0.05 g; MW power, 500 W; US power, 50 W; digestion time, 7 min (i.e., 5 min mineralization and 2 min oxidation). A modification of the classical Kjeldahl (Hach) method and an US-assisted digestion method were used for comparison. The latter was also optimized; the optimum conditions were: H2SO4 volume, 10 mL; H2O2 volume, 5 mL; sonication time with H2SO4, 15 min; sonication time with H2O2,10 min; US power, 50 W; weight of sample, 0.05 g. Five pure amino acids and two certified reference materials (NIST standard reference materials 1547 (peach leaves), and soil, NCS DC 73322) were analyzed to assess the accuracy of our new MW/US-assisted digestion method, that was successfully applied to five real samples. The significant reduction in digestion time (being 30 min and 25 min for classical Kjeldahl and US-assisted digestion methods, respectively) and consumption of reagents show that simultaneous and direct MW/US irradiation is a powerful and promising tool for low-pressure digestion of solid and liquid samples.  相似文献   

9.
To improve DMFC (direct methanol fuel cell) performance, a new method using ultrasonic radiation is proposed and a novel DMFC structure is designed and fabricated in the present paper. Three ultrasonic transducers (piezoelectric transducer, PZT) are integrated in the flow field plate to form the ultrasonic field in the liquid fuel. Ultrasonic frequency, acoustic power, and methanol concentration have been considered as variables in the experiments. With the help of ultrasonic radiation, the maximum output power and limiting current of cell can be independently increased by 30.73% and 40.54%, respectively. The best performance of DMFC is obtained at the condition of ultrasonic radiation (30 kHz and 4 W) fed with 2 M methanol solution, because both its limiting current and output power reach their maximum value simultaneously (222 mA and 33.6 mW, respectively) under this condition. These results conclude that ultrasonic can be an alternative choice for improving the cell performance, and can facilitate a guideline for the optimization of DMFC.  相似文献   

10.
A heterojunction T2SL barrier detector which effectively blocks majority carrier leakage over the pn-junction was designed and fabricated for the mid-wave infrared (MWIR) atmospheric transmission window. The layers in the barrier region comprised AlSb, GaSb and InAs, and the thicknesses were selected by using k · P-based energy band modeling to achieve maximum valence band offset, while maintaining close to zero conduction band discontinuity in a way similar to the work of Abdollahi Pour et al. [1] The barrier-structure has a 50% cutoff at 4.75 μm and 40% quantum efficiency and shows a dark current density of 6 × 10−6 A/cm2 at −0.05 V bias and 120 K. This is one order of magnitude lower than for comparable T2SL-structures without the barrier. Further improvement of the (non-surface related) bulk dark current can be expected with optimized doping of the absorber and barrier, and by fine tuning of the barrier layer design. We discuss the effect of barrier doping on dark current based on simulations. A T2SL focal plane array with 320 × 256 pixels, 30 μm pitch and 90% fill factor was processed in house using a conventional homojunction pin photodiode architecture and the ISC9705 readout circuit. High-quality imaging up to 110 K was demonstrated with the substrate fully removed.  相似文献   

11.
The present work reports a novel dual-pulse ultrasound enhanced electrochemical degradation (US-ECD) process that synchronizes alternatively ultrasound pulses and potential pulses to degrade nitrobenzene in aqueous solution with a high percentage degradation and low energy consumption. In comparison to the test results generated from the conventional US-ECD and original electrochemical degradation (ECD) process, the dual-pulse US-ECD process increased degradation percentages to nitrobenzene by 2% and 17%, respectively, while energy used in the pulse process was only about 46.5% of that was used in the conventional US-ECD process. Test results demonstrated a superior performance of the dual-pulse US-ECD process over those of other conventional ones. Impacts of pulse mode, initial pH value, cell voltage, supporting electrolyte concentration and ultrasonic power on the process performances were investigated. With operation conditions optimized in the study at pH = 3.0, cell voltage = 10 V, ultrasonic power = 48.84 W, electrolyte concentration = 0.1 M and an experiment running time of 30 min, the percentage degradation of nitrobenzene could reach 80% (US pulse time = 50 ms and ECD pulse time = 50 ms). This process provided a reliable and effective technical approach to degrade nitrobenzene in aqueous solution and significantly reduced energy consumption in comparison to the conventional US-ECD or original ECD treatment.  相似文献   

12.
《Ultrasonics》2013,53(1):225-231
The design of high voltage pulser for air coupled ultrasound imaging is presented. It is dedicated for air-coupled ultrasound applications when piezoelectric transducer design is used. Two identical N-channel MOSFETs are used together with 1200 V high and low side driver IC. Simple driving pulses’ delay and skew circuit is used to reduce the cross-conduction. Analysis of switch peak current and channel resistance relation to maximum operation frequency and load capacitance is given. PSPICE simulation was used to analyze the gate driver resistance, gate pulse skew, pulse amplitude influence on energy consumption when loaded by capacitive load. Experimental investigation was verified against simulation and theoretical predictions. For 500 pF capacitance, which is most common for piezoelectric air coupled transducers, pulser consumes 650 μJ at 1 kV pulse and 4 μJ at 50 V. Pulser is capable to produce up to 1 MHz pulse trains with positive 50 V–1 kV pulses with up to 10 A peak output current. When loaded by 200 kHz transducer at 1 kV pulse amplitude rise time is 40 ns and fall time is 32 ns which fully satisfies desired 1 MHz bandwidth.  相似文献   

13.
Micro power generating devices were fabricated by using a gold electroplated coil and a permanent magnet. The electrical power was generated when the magnet reciprocated on the fabricated electroplated coil. The output power was increased as a function of vibration frequency. A measurement system, which convert a rotational motion of a motor into a linear motion, was designed and fabricated. The purpose of this work is to develop the micro power generating devices which convert the ambient vibration or oscillating energy into useful electrical energy. With changing vibration frequency from 0.5 to 8 Hz, the generated power increased linearly. The generated voltage was 106 mV at 3 Hz and 198 mV at 6 Hz. After using the step up circuit, the measured voltage was 81 mV at 3 Hz and 235 mV at 6 Hz. From above the frequency of about 4.5 Hz, the gain obtained by using the quadrupler circuit becomes larger than the loss without using that circuit.  相似文献   

14.
SB349 is the first 32 × 32 CTIA readout multiplexer specifically designed for far-IR photodetectors and is operable at cryogenic temperatures at least as low as 1.7 K. Four of these readouts can be butted together to form a 64 × 64 mosaic array. The array is multiplexed into eight parallel outputs and features eight selectable gain settings to accommodate various background levels, auto-zero for better input uniformity, and sample-and-hold circuitry. A special, 2-micron cryo-CMOS process was adopted to prevent freeze out and ensure low noise and proper operation at deep cryogenic temperatures. The read noise of the bare device at 4.2 K and under nominal sampling conditions was measured to be about 250e? for the 106fF signal capacitor with the well capacity of 400ke?. Hybridized to a typical germanium detector, the array should achieve NEP levels in the low 10–18 W/√Hz. An overview of the design and the latest results of the test and characterization of this device are reported in this paper.  相似文献   

15.
Low-voltage direct current was applied to beef, inoculated with Escherichia coli O157:H7 on the surface covered with a thin film of 0.15 M NaCl solution. Experiments were conducted with 15, 30, and 45 mA/cm2 currents; 1, 10 and 100 kHz frequencies; 30, 50 and 70% duty cycles, and 2, 8 and 16 min treatment durations. Increase in current intensity, frequency, duty cycle, and treatment duration increased the % reduction of E. coli. A maximum reduction of 98.9% was achieved. Sensory color analysis showed significant differences between treated and untreated beef. The maximum temperature rise of NaCl solution was 31.9 °C.  相似文献   

16.
We present a novel electrostatic discharge (ESD) protection circuit for GaAs radio frequency (RF) integrated circuits (ICs), which are targeted for 10 Gb/s fiber-optic communication applications. The robustness, parasitic impedance, and loading effect of the new ESD protection circuit are studied and compared with the conventional diode-based ESD protection technique. Two versions of this type of ESD protection circuit were fabricated with a 60-GHz InGaP heterojunction bipolar transistor (HBT) technology. These two circuits can withstand, respectively, 2700 and 5000 V human body model (HBM) ESD stress and provide a similar level of ESD protection to RF ICs. The corresponding impedances of the off state are represented by an equivalent shunt capacitance and shunt resistance of 0.22 pF and 500 Ω, and 0.5 pF and 250 Ω, at 10 GHz. This ESD protection circuit can protect the 10 Gb/s RF ICs against much higher level ESD stress than conventional diode-based ESD protection circuits even with smaller size.  相似文献   

17.
This paper reports the first demonstration of the megapixel-simultaneously-readable and pixel-co-registered dual-band quantum well infrared photodetector (QWIP) focal plane array (FPA). The dual-band QWIP device was developed by stacking two multi-quantum-well stacks tuned to absorb two different infrared wavelengths. The full width at half maximum (FWHM) of the mid-wave infrared (MWIR) band extends from 4.4 to 5.1 μm and the FWHM of a long-wave infrared (LWIR) band extends from 7.8 to 8.8 μm. Dual-band QWIP detector arrays were hybridized with custom fabricated direct injection read out integrated circuits (ROICs) using the indium bump hybridization technique. The initial dual-band megapixel QWIP FPAs were cooled to 70 K operating temperature. The preliminary data taken from the first megapixel QWIP FPA has shown system NEΔT of 27 and 40 mK for MWIR and LWIR bands, respectively.  相似文献   

18.
Experiments on resonator micro-optic gyro (RMOG) with a digital proportional integral (PI) feedback scheme are performed. In this experimental setup, the key rotation sensing element is a polarization maintaining silica waveguide ring resonator (WRR) with a ring length of 7.9 cm and a diameter of 2.5 cm. A good linearity of 0.0015% over a wide range of ± 2 × 104 °/s can be achieved for the RMOG theoretically. The optimal digital PI feedback scheme is adopted in the frequency servo loop to reduce the reciprocal frequency fluctuations due to the WRR resonance frequency and laser frequency drifts. Residual equivalent input fluctuation can be reduced as low as 0.03 °/s/√Hz based on the optimal digital PI feedback scheme, which is close to the shot noise limited spectral density 0.02 °/s/√Hz of the RMOG with the input optical power of 0.2 mW. Relationship between RMOG output signal and angular rate is obtained from ± 0.1 °/s to ± 5 °/s. The standard deviation of the residuals between RMOG output results and linear fit curve is 0.066 °/s. For an integration of the processing circuit, all the processing circuit is implemented by a field programmable gate array (FPGA) instead of instruments. The output of this digitalized RMOG is obtained over a range of ± 550 °/s. The linearity of this digitalized RMOG is 0.0169%.  相似文献   

19.
Solar conversion efficiency of dye-sensitized solar cells was improved by UV–O3 treatment of TiO2 before and/or after sintering. The enhancement was resulted from the removal of the residual organics originated from the TiO2 precursor pastes, increased adsorption of dyes to the TiO2, surface, and longer diffusion length and shorter electron transit time of electrons through the TiO2 mesoscopic structure. The power conversion efficiency of the cells reaches to 7.2% with the open circuit voltage of 0.71 V, the short circuit current density of 15.2 mA/cm2 and the fill factor of 0.67 under illumination with AM 1.5 (100 mW/cm2) simulated sunlight.  相似文献   

20.
The effect of ultrasound (US) stimulation on the shear viscosity of aqueous polyvinyl alcohol (PVA) solution was studied when the solution was exposed to US at 23, 43, 96, and 141 kHz. The US stimulus showed a marked decrease of the shear viscosity of the solution in the order of 43 > 96 > 23 > 141 kHz, respectively, under US power dissipation of 8.5, 8.9, 8.9, and 8.8 W. Subsequently, when US exposure was stopped, the shear viscosity of PVA reverted to its original value. The US stimulation was analyzed with the US power transmitted through the PVA aqueous media. Furthermore, FT-IR spectra measured at different durations of US exposure, suggest that hydrogen bonds in the PVA segments were broken by the US exposure. We conclude that structural changes of the hydrogen bonded crosslinks of PVA were induced to include water molecules for the re-forming of crosslinks of aqueous PVA.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号