首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this work, personal thermoluminescence dosimeter (TLD) cards type of GN-6770 (holder type 8806) from Harshaw were used for personal neutron dosimetry. The response of the dosimeters has been determined in terms of the personal absorbed dose and personal dose equivalent for different neutron energy components, based on the recommendations of ICRP-60 and ICRU-49. Neutron irradiation was performed using a 5 mCi Am–Be neutron source. The TLD reader, type Harshaw 6600, was installed and calibrated for accurate neutron doses equivalent to gamma-ray doses. It was found that fast neutron doses measured by TLD (badges or cards) are in agreement with those measured by neutron TE (tissue equivalent gas) ionization chambers and neutron monitors. Thermal neutron doses measured by TLD cards were overestimated when compared with those measured by neutron monitors. Additional Cd was used to reduce thermal neutron doses to be in agreement with actual thermal doses. Other configurations for TLD crystals are also suggested for accurate thermal neutron dose measurements.  相似文献   

2.
A set of five 241Am–Be neutron sources are utilized in research and teaching at King Fahd University of Petroleum and Minerals (KFUPM). Three of these sources have an activity of 16 Ci each and the other two are of 5 Ci each. A well-shielded storage area was designed for these sources. The aim of the study is to check the effectiveness of shielding of the KFUPM neutron source storage area. Poly allyl diglycol carbonate (PADC) Nuclear track detectors (NTDs) based fast and thermal neutron area passive dosimeters have been utilized side by side for 33 days to assess accumulated low ambient dose equivalents of fast and thermal neutrons at 30 different locations around the source storage area and adjacent rooms. Fast neutron measurements have been carried out using bare NTDs, which register fast neutrons through recoils of protons, in the detector material. NTDs were mounted with lithium tetra borate (Li2B4O7) converters on their surfaces for thermal neutron detection via and nuclear reactions. The calibration factors of NTD both for fast and thermal neutron area passive dosimeters were determined using thermoluminescent dosimeters (TLD) with and without a polyethylene moderator. The calibration factors for fast and thermal neutron area passive dosimeters were found to be 1.33 proton tracks and 31.5 alpha tracks , respectively. The results show variations of accumulated dose with the locations around the storage area. The fast neutron dose equivalents rates varied from as low as up to whereas those for thermal neutron ranged from as low as up to . The study indicates that the area passive neutron dosimeter was able to detect dose rates as low as 7 and from accumulated dose for thermal and fast neutrons, respectively, which were not possible to detect with the available active neutron dosimeters.  相似文献   

3.
Results of the investigation concerning thermoluminescence (TL) responses to X, gamma and neutron radiation fields for crystals of complex fluoride K2GdF5 undoped and doped with varying concentrations of Dy3+ ions are presented. Crystals doped with 5.0 at% Dy3+ have shown the most efficient TL response, with a linear response to doses for all the radiation fields. In the X rays range, the maximum TL response has been found to be 15 times more than the response for gamma. The fast and thermal neutron TL outputs were evaluated for K2Gd0.95Y0.05F5 and the contribution of the gamma component in the TL curve was estimated.  相似文献   

4.
A spherical-type neutron dose monitor has been developed for the use of area monitoring around the neutron producing fields. Considering the practical fields that neutrons coming from multiple directions, the study has been performed using MCNP simulation, in order to estimate the resultant direction of the sources and to find a suitable method of H1(10) evaluation. This was done by irradiating the monitor using two neutron sources of different energies and intensities; placed at an angle between them. A parallel neutron beam of 50 cm radius with wide energy was used for the irradiation. The direction of the neutron sources was determined comparing the responses of 12 thermo-luminescent detectors (TLDs) of first layer between single and two directional sources. It was found that in most of the cases, the direction of the source was estimated to be the average angle or near the average angle of single sources. Using a linear combinational equation the method has been developed for evaluating the dose from the mean values of selected detectors of two consecutive depths of TLDs and the TLD of core depth. It was found that the ratio of the calculated to the expected dose was almost close to unity which indicates that the method can be used for evaluating the dose with good accuracy.  相似文献   

5.
This work presents an estimation of the neutron dose distribution for common bladder cancer cases treated with high-energy photons of 15 MV therapy accelerators. Neutron doses were measured in an Alderson phantom, using TLD 700 and 600 thermoluminescence dosimeters, resembling bladder cancer cases treated with high-energy photons from 15 MV LINAC and having a treatment plan using the four-field pelvic box technique. Thermal neutron dose distribution in the target area and the surrounding tissue was estimated. The sensitivity of all detectors for both gamma and neutrons was estimated and used for correction of the TL reading. TLD detectors were irradiated with a Co60 gamma standard source and thermal neutrons at the irradiation facility of the National Institute for Standards (NIS). The TL to dose conversion factor was estimated in terms of both Co60 neutron equivalent dose and thermal neutron dose. The dose distribution of photo-neutrons throughout each target was estimated and presented in three-dimensional charts and isodose curves. The distribution was found to be non-isotropic through the target. It varied from a minimum of 0.23 mSv/h to a maximum of 2.07 mSv/h at 6 cm off-axis. The mean neutron dose equivalent was found to be 0.63 mSv/h, which agrees with other published literature. The estimated average neutron equivalent to the bladder per administered therapeutic dose was found to be 0.39 mSv Gy?1, which is also in good agreement with published literature. As a consequence of a complete therapeutic treatment of 50 Gy high-energy photons at 15 MV, the total thermal neutron equivalent dose to the abdomen was found to be about 0.012 Sv.  相似文献   

6.
We discuss the development and characterisation of a new in situ spin exchange optical pumping (SEOP) based 3He neutron spin filter polarisation device. We present results from a recent test of the prototype system developed with the Institut Laue-Langevin. The polariser was installed on the polarised reflectometer CRISP at ISIS in the analyser position. The 3He was pumped continuously in situ on the beamline. The system also integrated a 3He adiabatic fast passage spin flipper that allowed reversal of the 3He and therefore neutron polarisation state, allowing for measurement of all four polarisation cross-sections. The system was run for a number of days reaching a 3He polarisation of 63%.  相似文献   

7.
Apoorva G. Wagh 《Pramana》2008,71(4):797-807
Bragg reflections from single crystals yield angular widths of a few arcsec for thermal neutron beams. The Bonse-Hart proposal to attain a sharp, nearly rectangular profile by Bragg reflecting neutrons multiply from a channel-cut single crystal, was realized in its totality three and a half decades later by achieving the corresponding Darwin reflection curves for 5.23 Å neutrons. This facilitated SUSANS (Super USANS) measurements in the Q ~ 10?5 Å?1 range. The polarized neutron option was introduced into the SUSANS set-up by separating the up- and down-spin neutron beams by ~10 arcsec with a magnetic (air) prism. The neutron angular width has recently been reduced further by an order of magnitude to ~0.6 arcsec by diffracting 5.3 Å neutrons from a judiciously optimized Bragg prism. This constitutes the most parallel monochromatic neutron beam produced to date. I present the first SUSANS spectra probing the Q ~ 10?6 Å?1 domain, recorded with this beam.  相似文献   

8.
With the new brilliant neutron sources and the developments of novel optical elements, neutron spin echo (NSE) spectroscopy evolves to tackle new problems and scientific fields. The new developments pave the way to complex experimental set-ups such as the intensity modulated variant of NSE (IMNSE), a powerful technique which was introduced some 20 years ago but found limited use up to now. With the new compact supermirror or He3 polarizers IMNSE becomes attractive for a broad range of applications in magnetism, soft matter and biology. A novel development along this line is the polarimetric NSE technique, which combines IMNSE and the zero-field polarimeter Cryopad to access components of the scattered polarization that are transverse to the incoming polarization. Polarimetric NSE is the method of choice for studying chiral fluctuations, as illustrated by new results on the reference helimagnet MnSi.  相似文献   

9.
In this paper, the effect of neutron irradiation on sapphire single crystal with fast neutron of 1.0×1018 and 1.0×1019 neutrons/cm2 has been investigated along with the effect of annealing temperature. It is found that the colorless transparent sapphire single crystals were turned yellow after 10 MeV fast neutron irradiation at room temperature. There are peaks at 206, 230, 258, 305, 358 and 452 nm after neutron irradiation. And the intensity of optical absorption bands decrease with wavelength and annealing temperature. A new absorption peak at 452 nm was found after isothermal annealing at 400 °C for 10 min, which was ascribed to F2+ color center. Because of the recombination of interstitial ions and vacancies, color centers were almost removed after annealing at 1000 °C. The TL peaks were found to shift to higher temperature after neutron irradiation. And a higher fluence of the neutron irradiation would result in deep traps revealed as the new TL peaks at 176 and 227 °C.  相似文献   

10.
We describe here a method of performing adiabatic fast passage (AFP) spin flipping of polarized 3He used as a neutron spin filter (NSF) to polarize neutron beams. By reversing the spin states of the 3He nuclei the polarization of a neutron beam can be efficiently reversed allowing for the transmission of a neutron beam polarized in either spin state. Using an amplitude modulated frequency sweep lasting 500 ms we can spin flip a polarized 3He neutron spin filter with only 1.8×10−5 loss in 3He polarization. The small magnetic fields (10-15 G) used to house neutron spin filters mean the 3He resonant frequencies are low enough to be generated using a computer with a digital I/O card. The versatility of this systems allows AFP to be performed on any beamline or in any laboratory using 3He neutron spin filters and polarization losses can be minimised by adjusting sweep parameters.  相似文献   

11.
Magnetic supermirrors are widely used in polarized neutron applications. A key issue in producing these multilayer structures is to avoid residual stress in the layers, which may cause the layers to peel off. In this work He+ ion irradiation of 500 keV energy was applied at fluences of 1, 24, 50, 100×1014 ions/cm2 with the aim of reducing residual stress. Structural, magnetic and neutron-optical properties were investigated by grazing incidence high-angle X-ray diffraction, magneto-optical Kerr effect, conversion electron Mössbauer spectroscopy and polarized neutron reflectometry. We find a monotonous decrease of the tensile stress upon irradiation from 1.76 to 0.37 GPa with a coupled decrease of neutron reflectivity at the critical angle and decrease of the maximum polarizing efficiency from 23% to 4% at the highest fluence compared to the as-prepared reference supermirror. The supermirrors exhibit a superposition of uniaxial and fourfold in-plane magnetic anisotropy.  相似文献   

12.
Polarized 3He has shown its unique characteristics in many areas of polarized neutron scattering, its ability to polarize neutrons at short wavelengths, accept wide-angle and divergent beams and low backgrounds enable new classes of experiments. While polarized 3He is not a steady state solution as commonly applied, the benefits have been shown to offset the drawbacks of polarizing and refreshing the polarization in the neutron spin filter cells. As an extension of this work, in-situ polarization using the spin-exchange optical pumping (SEOP) method was explored as a means to construct a system which could be used to polarize 3He in the state used for an effective neutron spin filter to constant polarization while on the neutron beam. An in-situ SEOP polarizer was constructed. This device utilized many devices and principles developed for neutron spin filters which are polarized off the beam line using either SEOP or metastability exchange optical pumping (MEOP) under the same research program. As a collimation of this work effects of extremely high neutron capture flux density incident on the in-situ polarizer were explored.  相似文献   

13.
We measured the neutron beam polarization of the BL05/NOP (Neutron Optics and Physics) beamline at J-PARC with an accuracy of less than 10−3 using polarized 3He gas as a neutron spin analyzer. Precise polarimetry of the neutron beam is necessary to understand the beamline optics as well as for the asymmetry measurements of the neutron beta decay, which are planned in this beamline.  相似文献   

14.
Contemporary linear accelerators applied in radiotherapy generate X-ray and electron beams with energies up to 20 MeV. Such high-energy therapeutic beams induce undesirable photonuclear (γ,n) and electronuclear (e,e'n) reactions in which neutrons and radioisotopes are produced. The originated neutron can also induce reactions such as simple capture, (n,γ), reactions that produce radioisotopes. In this work measurements of the non-therapeutic neutrons and the induced gamma radiation were carried out in the vicinity of a new medical accelerator, namely the Varian TrueBeam. The TrueBeam is a new generation Varian medical linac making it possible to generate the X-ray beams with a dose rate higher than in the case of the previous models by Varian. This work was performed for the X-ray beams with nominal potentials of 10 MV (flattening filter free), 15 MV and 20 MV, and for a 22 MeV electron beam. The neutron measurements were performed by means of a helium chamber and the induced activity method. The identification of radioisotopes produced during emission of the therapeutic beams was based on measurements of the energy spectra of gammas emitted in decays of the produced nuclei. The gamma energy spectra were measured with the use of the high-purity germanium detector. The correlation between the neutron field and the mode and nominal potential was observed. The strongest neutron fluence of 3.1 × 106 cm−2 Gy−1 and 2.0 × 106 cm−2 Gy−1 for the thermal and resonance energies, respectively, was measured during emission of the 20 MV X-ray beam. The thermal and resonance neutron fluence measured for the 15 MV X-rays was somewhat less, at 1.1 × 106 cm−2 Gy−1 for thermal neutrons and 6.7 × 105 cm−2 Gy−1 for resonance neutrons. The thermal and resonance neutron fluences were smallest for the 10 MV FFF beam and the 22 MeV electron beam and were around two orders of magnitude smaller than those of the 20 MV X-ray beam. This work has shown that the neutron reactions are dominant because of relatively high cross sections for many elements used in the accelerator construction. The detailed analysis of the measured spectra made it possible to identify 11 radioisotopes induced during TrueBeam delivery. In this work the following radioisotopes were identified: 56Mn, 122Sb, 124Sb, 131Ba, 82Br, 57Ni, 57Co, 51Cr, 187W, 24Na and 38Cl.  相似文献   

15.
The changes in direction of the neutron spin that take place on scattering by a magnetic interaction vector are highly dependent on their relative directions. In some circumstances, without zero-field polarimeter, it is impossible to distinguish between a simple depolarisation and a rotation of the polarisation vector.Motivated by the investigation of chiral magnetic fluctuations, we have implemented the third-generation zero-field polarimeter Cryopad on the neutron spin-echo spectrometer SPAN at the Helmholtz Centre Berlin (HCB). We present the method and the limitations of this novel technique that is now available on IN15 at the ILL.The huge progress accomplished with 3He neutron spin filters/flippers are going to facilitate the exploitation of polarised beams at spallation sources. Zero-field polarimeters like Cryopad are used routinely at several steady-state sources but their design would be inefficient at a pulse source. We have investigated the possibility to implement a zero-field polarimeter on a time-of-flight spectrometer. We propose a design that would lead to a better efficiency and present the finite element calculations.  相似文献   

16.
Recent status of the neutron reflectometer SUIREN is presented. Since its startup in 2006, SUIREN has been the only neutron reflectometer in Japan for magnetic samples with high magnetic field sample environment, and used for investigations of magnetic films, solid-liquid interfaces and other solid thin films. SUIREN provides monochromatic neutron beam of 3.93 Å for vertically placed sample surface. Polarized beam is also available together with a 1 T electromagnet for sample. Beam intensity at the sample position in the unpolarized mode is for beam collimation of Δθ=0.08. Reflectivity can be explored down to 10-6.  相似文献   

17.
We have designed and demonstrated a prototype on-beam spin-exchange optical pumping (SEOP) 3He neutron spin filter (NSF). It is designed as the incident neutron polarizer for spallation neutron sources, where the installation space is limited due to thick radiation shielding. The size of the NSF is roughly 50 cm×50 cm×25 cm including the diode-laser optics with a frequency narrowing external cavity, and a cylindrical 3He cell as large as a diameter of 5 cm and a length of 10 cm can fit. A neutron beam test was performed at the NOP beamline of JRR-3 to see the performance of the NSF.  相似文献   

18.
A high resolution neutron spectrometer making use of a ΔT-window filter for the analyser and time-of-flight technique for analysing incident neutron energy has been designed. The spectrometer will provide a continuously variable energy resolution ΔE from 40–50μeV at ∼ 5230μeV. The range of energy transfer allowed is −1450μeV to +2950μeV and the range of wavevector transferQ allowed is 0·82–3·06 ?−1. Depending on the resolution used, the counting rates are expected to vary from 28–60 × 103 counts/hr if one assumes 10% isotropic elastic scattering from the sample.  相似文献   

19.
S. Klotz  G. Hamel  J. Frelat 《高压研究》2013,33(1):219-223
We present a new type of compact hydraulic press of 200?t capacity and 60?kg mass provided with two large openings of 140° (equatorial) x 60° (azimuthal) around the sample area. This device has been designed and optimized using finite element calculations, and was built and recently successfully tested. A smaller version with 50 tonnes capacity and 8?kg mass is also available. This ‘VX’ type Paris–Edinburgh press is expected to have numerous applications in neutron and X-ray scattering whenever large sample volumes (typically 1–100?mm3) are required, in particular for angle-dispersive powder neutron diffraction on reactor sources, single crystal neutron diffraction, and inelastic neutron and X-ray scattering.  相似文献   

20.
At different frequency range it has been studied the influence of temperature and amount of falling neutrons on nano SiO2 irradiated with neutrons. It has been revealed that it is generated additional electroactive radiation defects under the influence of rays omitted from activation products or direct neutron. Thus, the change of neutron flux at 6.7 × 1017 ∼ 2.7 × 1018 cm−2 s−1 range increases the electric conductivity of nano SiO2 for approximately 30 times. It has been revealed two temperature ranges at temperature dependence of non-irradiated sample and three temperature ranges at a neutron irradiated-sample. It has been put forward the mechanism that explains the obtained results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号