首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The direct determination of element signatures in polar ice core samples from Greenland by laser ablation with subsequent inductively coupled plasma mass spectrometry analysis has been investigated. A cryogenic sample chamber enables the element determination in ice directly from the solid (frozen) state. A procedure was developed to analyse up to 38 elements (traces: Mg, Al, Fe, Zn, Cd, Pb and rare earth elements; minor constituents: Na) in ice samples from Greenland with a previously unachievable spatial resolution of 4 mm along the core axis. This resolution is helpful to detect seasonal variations of element concentration in thin annual layers of deep ice. We report operating conditions and analytical performance of the experimental set up, the improvement of signal stability by (17)OH internal standardisation and application of a desolvation unit. Calibration of the system was performed with frozen multielement standard solutions along a special preparation procedure. Detection limits for the tracers Na, Mg (sea salt), Al (mineral dust) and Zn (anthropogenic source) are 0.1-1 microg kg(-1). Best detection limits in the range of 0.001-0.01 microg kg(-1 )were reached for Co, Pb and all rare earth elements. To validate the method, frozen standard reference materials were measured. The recovery is about +/-10%. Greenland ice core samples from different ages were analysed with the new technique. The results obtained by laser ablation were compared with values from solution analysis, available published data and the particle content. Most elements have shown good correlation with the particle content in the Greenland samples; however, differences could be seen between the values obtained by laser ablation and solution bulk analysis after a tri-acid digestion. The influence of particles is discussed. The high spatially resolved 2D mapping of element concentrations shows strong inhomogeneities along the core axis most probably due to seasonal variations of element deposition.  相似文献   

2.
Capillary electrophoresis (CE) was used to separate the neptunium oxidation states Np(IV) and Np(V), which are the only oxidation states of Np that are stable under environmental conditions. The CE setup was coupled to an inductively coupled plasma mass spectrometer (Agilent 7500ce) using a Mira Mist CE nebulizer and a Scott-type spray chamber. The combination of the separation capacity of CE with the detection sensitivity of inductively coupled plasma mass spectrometry (ICP-MS) allows identification and quantification of Np(IV) and Np(V) at the trace levels expected in the far field of a nuclear waste repository. Limits of detection of 1?×?10-9 and 5?×?10-10 mol L-1 for Np(IV) and Np(V), respectively, were achieved, with a linear range from 10-9 to 10-6 mol L-1. The method was applied to study the redox speciation of the Np remaining in solution after interaction of 5?×?10-7 mol L-1 Np(V) with Opalinus Clay. Under mildly oxidizing conditions, a Np sorption of 31% was found, with all the Np remaining in solution being Np(V). A second sorption experiment performed in the presence of Fe2+ led to complete sorption of the Np onto the clay. After desorption with HClO4, a mixture of Np(IV) and Np(V) was found in solution by CE–ICP–MS, indicating that some of the sorbed Np had been reduced to Np(IV) by Fe2+.  相似文献   

3.
An LC–MS method for the determination of dothiepin in human plasma was developed and validated. Sample preparation involved extraction with n-hexane:2-propanol (95:5). Separation was on an Ultimate XB C18 column (2.1 × 150 mm, 5 μm). A single-quadrupole mass spectrometer with an electrospray interface was operated in the selected-ion monitoring mode to detect the [M+H]+ ions at m/z 296 for dothiepin and at m/z 278 for the internal standard (amitriptylene). The method demonstrated good linearity from 0.78 ng mL?1 (the LOQ) to100 ng mL?1. The mean extraction recovery was 82.4% for dothiepin and and 84.2% for the internal standard. The intra-day and inter-day precision ranged from 8.5 to 11.4% and 9.7 to 12.1% (RSD), respectively. The method was successfully applied to bioequivalence studies of dothiepin hydrochloride tablets to obtain the pharmacokinetic parameters.  相似文献   

4.
A European directive was recently adopted limiting the use of hazardous substances such as Pb, Hg, Cd, and Cr(VI) in vehicle manufacturing. From July 2003 a maximum of 2 g Cr(VI) will be authorised per vehicle in corrosion-preventing coatings of key components. As no standardised procedures are available to check if produced vehicles are in agreement with this directive, the objective of this work was to develop analytical procedures for total chromium and Cr(VI) determination in these materials. The first step of this study was to optimise digestion procedures for total chromium determination in plastic and metallic materials by inductively coupled plasma mass spectrometry (ICP–MS). High resolution (HR) ICP–MS was used to examine the influence of polyatomic interferences on the detection of the 52Cr+ and 53Cr+ isotopes. If there was strong interference with m/z 52 for plastic materials, it was possible to use quadrupole ICP–MS for m/z 53 if digestions were performed with HNO3+H2O2. This mixture was also necessary for digestion of chromium from metallic materials. Extraction procedures in alkaline medium (NH4+/NH3 buffer solution at pH 8.9) assisted by sonication were developed for determining Cr(VI) in four different corrosion-preventing coatings by HPLC–ICP–MS. After optimisation and validation with the only solid reference material certified for its Cr(VI) content (BCR 545; welding dusts), the efficiency of this extraction procedure for screw coatings was compared with that described in the EN ISO 3613 standard generally used in routine laboratories. For coatings comprising zinc and aluminium passivated in depth with chromium oxides the extraction procedure developed herein enabled determination of higher Cr(VI) concentrations. This was also observed for the screw covered with a chromium passivant layer on zinc–nickel. For coating comprising a chromium passivant layer on alkaline zinc the standardized extraction procedure was more efficient. In the case of painted metallic plate, because of a reactive matrix towards Cr(VI), its extraction without degradation was difficult to perform.  相似文献   

5.
Clindamycin is used for infections caused by Gram-positive and Gram-negative anaerobic pathogens and Gram-positive aerobes. Propionibacterium acnes is an important opportunistic microorganism of the human skin and is related to prostatitis. An LC–electrospray ionization–quadrupole time-of-flight–MS method was validated for determining clindamycin concentrations in plasma and prostate microdialysate. Clindamycin separation was carried out on a C18 column at 0.5 mL/min. The mobile phase employed gradient elution of formic acid and methanol. A mass spectrometer was operated in positive electrospray ionization mode to monitor ion 425.1784 and 253.1152 for clindamycin and cimetidine (internal standard), respectively. Linearity was obtained at 0.5–10.0 μg/mL (plasma) and 0.05–1.0 μg/mL (microdialysate) with coefficients of determination ≥0.999. The intra- and inter-day precision (coefficient of variation - CV%) values were ≤13.83% and 12.51% for plasma, respectively, and ≤10.90% and 9.35% for microdialysate, respectively. The accuracy was between 90.82% and 108.25% for plasma, and 96.97% and 106.98% for microdialysate. The present method was fully validated and applied to investigate clindamycin concentrations in both plasma and prostate by microdialysis in Wistar rats (80 mg/kg, intravenous). Because the penetration of antibiotics into the prostate may be restricted, this method allows us to investigate the prostate concentrations of clindamycin for the first time.  相似文献   

6.
Phospholipids are major constituents of biological membranes in plants and animals. Phospholipid-containing substances, such as lecithin, have also received increasing attention as emulsifiers in pharmaceutical drug delivery systems. The phospholipids phosphatidylcholine, phosphatidylethanolamine, phosphatidylinositol, their lysophosphatidyl hydrolysis products and sphingomyelin, were quantified in lecithin and lecithin-containing drug-delivery emulsions. Lysophospholipids are constituents of lecithin, but their formation during thermal sterilization of the investigated drug delivery systems might contribute to the concentrations found in the emulsions.  相似文献   

7.
An on-line HPLC–ESI–MS–MS method has been developed for determination of glutathione and phytochelatins (PC) in plant tissues. For sample pretreatment, dithiothreitol (DTT) must be added at the very beginning, as an anti-oxidant. Optimization of instrumental conditions i.e. composition of HPLC mobile phase, ionization efficiency of the electrospray interface, and MS–MS detection in the multiple ion-monitoring mode, are the central aspects of this work. A polystyrene-packed column was found to be superior to a standard silica-packed reversed-phase column. A concave quadratic gradient of ammonium formate buffer and acetonitrile was found to be optimum. The limits of quantitation were 0.2 mol kg–1 plant tissue for glutathione and PC. The method has been applied to analysis of tissue samples from Vicia faba grown in Cd-containing nutrient solutions.Dedicated to the memory of Wilhelm Fresenius  相似文献   

8.
ICP–MS techniques based on isotope dilution analysis can be regarded as an emerging tool in quantitative protein analysis. Well-known concepts, for example species-specific and unspecific isotope dilution analysis, which promoted accurate and precise quantification in elemental speciation studies, have nowadays been transferred to the analysis of large biomolecules, e.g. proteins. Besides detection of heteroatom-containing proteins, the artificial introduction of metal-containing labels has attracted much attention and, as a consequence, ICP–MS-based isotope dilution techniques can serve as a valuable quantification tool. In particular, because isotope dilution ICP–MS techniques can enable absolute protein quantification, they can be regarded as an attractive technique in current and prospective proteomics. In this review, recent developments and applications will be highlighted and critically assessed.  相似文献   

9.
A rapid and sensitive liquid chromatography–electrospray ionization mass spectrometry method was developed for the determination of aesculin in rat plasma. The analyses were chromatographed on a Zorbax Extend-C18 analytical column (150 × 2.1 mm I.D., 5 µm) with 30:70 (v/v) methanol–0.1% formic acid as mobile phase. Detection was performed by triple-quadrupole tandem mass spectrometry in multi-reaction-monitoring mode with an electrospray ionization source. The method was validated for accuracy and precision, and linearity in the two matrices was good. The assay was linear in the range 12.5–1,800 ng mL?1. The lower limit of quantification of aesculin (LLOQ) was 12.5 ng mL?1. The recovery of aesculin and tinidazole (IS) were well above 85%. The within- and between-batch accuracy was 100–104% and 97–109%, respectively. There were no stability-related problems in the procedure for the analysis of aesculin. The method was successfully used in a preclinical study of the pharmacokinetics of aesculin in rats.  相似文献   

10.
A capillary electrophoresis inductively coupled plasma mass spectrometry method for separation of free cisplatin from liposome-encapsulated cisplatin and protein-bound cisplatin was developed. A liposomal formulation of cisplatin based on PEGylated liposomes was used as model drug formulation. The effect of human plasma matrix on the analysis of liposome-encapsulated cisplatin and intact cisplatin was studied. The presence of 1 % of dextran and 4 mM of sodium dodecyl sulfate in HEPES buffer was demonstrated to be effective in improving the separation of liposomes and cisplatin bound to proteins in plasma. A detection limit of 41 ng/mL of platinum and a precision of 2.1 % (for 10 μg/mL of cisplatin standard) were obtained. Simultaneous measurements of phosphorous and platinum allows the simultaneous monitoring of the liposomes, liposome-encapsulated cisplatin, free cisplatin and cisplatin bound to plasma constituents in plasma samples. It was demonstrated that this approach is suitable for studies of the stability of liposome formulations as leakage of active drug from the liposomes and subsequent binding to biomolecules in plasma can be monitored. This methodology has not been reported before and will improve characterization of liposomal drugs during drug development and in studies on kinetics.
Figure
A method for distinguishing free cisplatin from liposome-encapsulated and protein-bound platinum in human plasma allows for studies of stability and kinetics of new drug formulations during drug development  相似文献   

11.
A liquid chromatography–electrospray ionization tandem mass spectrometry method has been developed to perform the determination of 5-hydroxytryptamine (5-HT), norepinephrine (NE), dopamine (DA) and their metabolites, i.e., 5-hydroxyindole-3-acetic acid (5-HIAA), 4-hydroxy-3-methoxyphenylglycol (MHPG) sulfate, 3,4-dihydroxyphenylacetic acid (DOPAC) and homovanillic acid (HVA) in rat brain tissue. Analytes were separated on a Thermo C18 column (4.6 mm × 250 mm, 5 μm, SN: 1245575T, Thermo electron corporation, USA) with a mobile phase of 0.05% formic acid/acetonitrile (92:8 for ESI+, 82:18 for ESI?, v/v) at the flow-rate of 0.8 mL min?1. The LC system was coupled to a Waters Micromass Quattro Premier XE tandem quadruple mass spectrometer. MS acquisition of 5-HT, NE and DA was performed in positive electrospray ionization multiple reaction monitoring (MRM) mode, while negative electrospray ionization MRM mode was used to monitor their metabolites. The calibration curves were linear within the concentration range of 4–4,450 ng mL?1 for 5-HT, 4–4,110 ng mL?1 for NE and 4–4,100 ng mL?1 for DA (≥ 0.999). The limit of quantitation was 4 ng mL?1. 5-HIAA, MHPG, DOPAC and HVA have good linearity within the range of 12–1,000 ng mL?1(≥ 0.998) and the limit of quantitation was 12 ng mL?1. The intra- and inter-day RSD were lower than 8.45%. The method is sensitive, fast, accurate and usable for quantity determination of monoamine neurotransmitters and their metabolites in neuropsychiatric diseases.  相似文献   

12.
Zhang  Chunhua  Wu  Huiqin  Huang  Xiaolan  Zhu  Zhixin  Luo  Huitai  Huang  Fang  Lin  Xiaoshan 《Chromatographia》2012,75(9-10):499-511

A sensitive and selective method for simultaneous determination of 29 toxic alkaloids in human blood and 31 in urine using high-performance liquid chromatography–electrospray ionization-tandem mass spectrometry was developed and validated. The samples were diluted with 0.1 mol L−1 HCl, and the target alkaloids were purified by solid phase extraction. The separation of 31 alkaloids was carried out on a C18 column using a gradient mobile phase with 10 mmol L−1 ammonium formate in water with 0.1% formic acid and methanol at the rate of 0.25 mL min−1. The triple-quadrupole mass spectrometer equipped with an electrospray source in the positive mode was set up in the dynamic multiple reactions monitoring mode (dynamic MRM) to detect the ion transitions of 31 alkaloids. The calibration curves were linear over a range of 0.5–400, 1–400, or 4–400 μg L−1 for target alkaloids in human blood and urine, and the correlation coefficients (r 2) was higher than 0.9943. The limit of determination and limit of quantification were 0.2–1 and 0.5–4 μg L−1 for blood and urine, respectively. The only exceptions were sanguinarine and chelerythrine in human blood. All the target alkaloids were stable under the test condition. In addition, the solvent effect and reconstituted solution were investigated. The method was validated and proved to be accurate and precise over the studied concentrations and suitable for poisoning diagnosis and forensic toxicology.

  相似文献   

13.
A convenient, selective and sensitive liquid chromatographic-electrospary ionization mass spectrometry (LC–ESI–MS) method was developed and validated to determine lovastatin in human plasma. The analyte was extracted from human plasma samples by typical liquid–liquid extraction, separated on a C18 column by using the mobile phase consisting of water–methanol (13:87, v/v). Simvastatin was used as the internal standard (IS). The method was linear within the range of 0.1–20 ng mL−1. The lower limit of quantification (LLOQ) was 0.1 ng mL−1. The intra- and inter-run precision, calculated from quality control (QC) samples was less than 10.2%. The accuracy as determined from QC samples was in the range of 99.3–102.9% for the analyte. The mean recoveries for lovastatin and IS were 84.8 and 88.0%, respectively. The method was successfully applied for evaluation of the pharmacokinetic of lovastatin in healthy volunteers.  相似文献   

14.
Ion chromatography (IC) and atomic spectrometry are sometimes rivalling and sometimes ideally cooperating techniques. The cooperating applications of the on-line coupling of IC and inductively coupled plasma–atomic emission spectroscopy or –mass spectrometry span from ultra trace analysis utilizing ion exchange as preconcentration technique via speciation applications taking advantage of the unique element specific detection offered by atomic spectroscopy until classical IC applications with atomic spectrometry as a sensitive and selective detector. Characteristics of this type of hyphenated technique are the simple physical coupling, the unique sensitivity for most elements and the superior selectivity obtainable for specific applications.  相似文献   

15.
Flupentixol and an internal standard, loperamide were extracted from human plasma by liquid–liquid extraction and analyzed on a Thermo Hypersil HyPURITY C18 column, with 10 mM ammonium acetate–acetonitrile–methanol (26:62:12, v/v/v) as mobile phase, coupled with electrospray ionization mass spectrometry (ESI–MS). The protonated analyte was quantified by selected-ion monitoring (SIM) with a quadrupole mass spectrometer in a positive-ion mode. The calibration curve was linear (r = 0.9990) over the concentration range: 0.039–2.5 ng mL?1. Intra-day and inter-day precision (RSD%) were less than 13.05%. The established method was successfully applied for the determination of pharmacokinetics of flupentixol in human plasma.  相似文献   

16.
Summary A sensitive and selective liquid chromatographic method coupled with electrospray ionization tandem mass spectrometry (LC–ESI–MS–MS) has been developed for quantification of felodipine in human and dog plasma. Compounds were separated on a 2.0 mm × 150 mm, 5.0 m particle, C8 column with 1 m m ammonium acetate–acetonitrile, 20:80, pH 6.0, as mobile phase at a flow rate of 200 L min–1. Nifedipine was used as internal standard. Plasma samples were extracted with diethyl ether, the centrifuged upper layer was evaporated, the residue was reconstituted with mobile phase, and the reconstituted samples were injected. The analytical column lasted for at least 1000 injections. By use of multiple reaction monitoring (MRM) mode in MS–MS felodipine and nifedipine were detected without severe interference from the human or dog plasma matrix. Felodipine produced a protonated precursor ion ([M + H]+) at m/z 384 and a corresponding product ion at m/z 338. And internal standard (nifedipine) produced a protonated precursor ion ([M + H]+) at m/z 347 and a corresponding product ion at m/z 315. Detection of felodipine in human and dog plasma was accurate and precise, with a limit of quantification of 0.05 ng mL–1. The method has been successfully applied to preliminary pharmacokinetic study of felodipine in human and dog plasma.  相似文献   

17.
Melarsoprol is the only currently available drug for treatment of the late stage of African trypanosomiasis (sleeping sickness). Unfortunately, the arsenic-containing drug causes serious side effects, for which the mechanisms have not been elucidated so far. This investigation describes the study of the melarsoprol biotransformation processes by electrochemical (EC) techniques. Based on EC, potential oxidation reactions of melarsoprol are examined. Moreover, the reactivity of melarsoprol, its metabolite melarsen oxide, and their oxidation products toward the tripeptide glutathione and the proteins hemoglobin and human serum albumin is evaluated. The combination of different analytical techniques allows the identification as well as the quantification of the biotransformation products. The hyphenation of liquid chromatography (LC) and electrospray ionization mass spectrometry (ESI–MS) is applied for identification and structure elucidation, which implies the determination of exact masses and fragmentation patterns. For the selective detection of arsenic containing metabolites, LC coupled to inductively coupled plasma mass spectrometry is utilized. Based on the obtained data, the oxidative biotransformation of melarsoprol can be predicted, revealing novel species which have been suspected, but not been identified up to now. The results of the protein studies prove that melarsen oxide, the active derivative of melarsoprol, strongly binds to human hemoglobin and forms different adducts via the free cysteinyl groups of the hemoglobin α- and β-chain.  相似文献   

18.
The purpose of this article was to develop a rapid and robust LC–MS–MS method for quantifying shikonin and deoxyshikonin simultaneously in rat plasma using emodin as internal standard. The LC system consisted of an Agilent ZORBAX SB-C18 (1.8 μm, 250 × 4.6 mm, 20 °C) column. Elution with an isocratic mobile phase consisted of methanol/10 mM ammonium acetate in water/acetonitrile containing 0.05% formic acid (45:10:45, v/v/v) at a flow rate of 0.8 mL min?1 yielded sharp, high-resolved peaks within 12 min. The lower limits of quantitation were 0.5 ng mL?1 for shikonin, and 8 ng mL?1 for deoxyshikonin. Correlation coefficient (r) values for the linear range of two analytes were greater than 0.99. Assay precision was <13% and accuracy was 87–99%. This newly developed method was used to the pharmacokinetic studies of the shikonin analogues in rats after intravenous administration (n = 4).  相似文献   

19.
A liquid chromatography–tandem mass spectrometry (LC–MS–MS) method was developed for the simultaneous determination of paracetamol, pseudoephedrine and chlorpheniramine in human plasma. Diphenhydramine was used as the internal standard. Analytes were extracted from alkalized human plasma by liquid–liquid extraction (LLE) using ethyl acetate. After electrospray ionization positive ion fragments were detected in the selected reaction monitoring (SRM) mode with a triple quadrupole tandem mass spectrometer. The method was linear in the concentration range of 20.0–10000.0 ng mL?1 for paracetamol, 1.0–500.0 ng mL?1 for pseudoephedrine and 0.1–50.0 ng mL?1 for chlorpheniramine. The intra- and inter-day precisions were below 14.5% and the bias was between ?7.3 and +2.8% for all analytes. The validated LC–MS–MS method was applied to a pharmacokinetic study in which each healthy Chinese volunteer received a tablet containing 300 mg benorylate, 30 mg pseudoephedrine hydrochloride and 2 mg chlorpheniramine maleate. This is the first assay method described for the simultaneous determination of paracetamol, pseudoephedrine and chlorpheniramine in human plasma samples.  相似文献   

20.
Xin Hu  Yun-Feng Lv  Kai-Shun Bi 《Chromatographia》2009,69(9-10):1073-1076
A rapid and simple high-performance liquid chromatographic tandem mass spectrometric method has been developed and validated for analysis of strictosamide in rat plasma. Chromatographic separation was achieved on a C18 column by gradient elution with mixtures of methanol, water, and acetonitrile containing 0.05% acetic acid. Digoxin was used as internal standard. Selected reaction monitoring (SRM) was used for MS quantitation. Linearity was good in the range 0.05–20 ng mL?1 in rat plasma. The lower limit of quantitation was 0.04 ng mL?1. The method is precise and reliable and can be applied to pharmacokinetic studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号