首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Analytical letters》2012,45(1):90-103
Abstract

A sensitive and reliable stripping voltammetric method was developed to determine Spironolactone drug. This method is based on the adsorptive accumulation of the drug at a hanging mercury drop electrode and then a negative sweep was initiated, which yield a well defined cathodic peak at ?1000 mV versus Ag/AgCl reference electrode. To achieve high sensitivity, various experimental and instrumental variables were investigated such as supporting electrolyte, pH, accumulation time and potential, drug concentration, scan rate, frequency, pulse amplitude, convection rate and working electrode area. The monitored adsorptive current was directly proportional to the concentration of Spironolactone and it shows a linear response in the range from 1×10?8 to 2.5×10?7 mol l?1 (correlation coefficient=0.999) and the detection limit (S/N=3) is 1.72×10?10 mol l?1 at an accumulation time of 90 sec. The developed AdSV procedure shows a good reproducibility, the relative standard deviation RSD% (n=8) at a concentration level of 1.5×10?7 mol l?1 was 1.4%, whereas the method accuracy was indicated via the mean recovery of 97.5%±2.04. Possible interferences by several substances usually present in the pharmaceutical formulations have been also evaluated. The applicability of this approach was illustrated by the determination of Spironolactone in pharmaceutical preparation and biological fluids such as serum and urine.  相似文献   

2.
《Analytical letters》2012,45(11):1783-1802
Abstract

Griseofulvin is an antifungal antibiotic used to treat various pathogenic mycotic diseases. The voltammetric behavior of griseofulvin at a hanging mercury drop electrode in Britton‐Robinson buffers of pH 2–11.5 was studied and discussed. A fully validated sensitive square‐wave adsorptive cathodic stripping voltammetric procedure was described for direct determination of bulk griseofulvin substance. The procedure was based on the reduction of the >C?O double bond of griseofulvin molecule following its preconcentration onto a hanging mercury drop electrode in a Britton‐Robinson buffer of pH 10. Limits of detection (LOD) and quantitation (LOQ) of 5.8×10?10 M and 1.93×10?9 M bulk griseofulvin were achieved, respectively. The proposed stripping voltammetric procedure was successfully applied to assay griseofulvin in tablets and in spiked human serum and urine samples. LOD of 8.65×10?10 M and 6.6×10?9 M and LOQ of 2.88×10?9 M and 2.2×10?8 M griseofulvin in spiked human serum and urine samples, respectively, were achieved.  相似文献   

3.
Nitroxoline has been reduced at the mercury electrode in buffered solutions (pH 2?11) in two irreversible cathodic steps. The first step was attributed to reduction of –NO2 group to the hydroxylamine stage and the second one to reduction-saturation of the C=N double bond. DC-polarographic and various adsorptive stripping voltammetric methods were developed for determination of nitroxoline in bulk form. Limits of quantitation of 1.02 × 10?6, 3.05 × 10?8, 9.01 × 10?9, and 9.12 × 10?10 M nitroxoline were achieved by means of the developed DC-polarography, differential-pulse-, linear-sweep-, and square-wave-adsorptive cathodic stripping voltammetric methods, respectively. All these electroanalytical methods were successfully applied for determination of nitroxoline in its Nibiol® tablets. While only the developed adsorptive stripping voltammetry methods were successfully applied for determination of the drug in spiked human serum and for pharmacokinetic studies in real human plasma. The analysis was carried out without interference from common excipients and without the necessity for prior extraction or interaction with any reagent during the analysis.  相似文献   

4.
A sensitive electrochemical method based on square wave cathodic adsorptive stripping voltammetry (SWCASV) using pencil graphite electrodes (PGE) was developed for the individual and simultaneous determination of the anticancer drugs flutamide (Flu) and irinotecan (Irino) in biological fluids. Calibration curves showed an excellent linear response with limits of detection of 1.68×10?9 and 1.55×10?8 M Irino and Flu, respectively. The statistical evaluation of within‐day repeatability (n=5) and day to day precision (n=5) showed satisfactory accuracy and precision. SWCASV using a PGE for individual and simultaneous determination of both drugs in bulk form, human urine and serum samples was demonstrated.  相似文献   

5.
The electro-reduction of tolmetin at the hanging mercury drop electrode was studied in different supporting electrolytes using cyclic voltammetry and square-wave stripping voltammetry techniques. Voltammograms of tolmetin exhibited a single well-defined 2-electron irreversible cathodic peak in media of pH < 4, which may be attributed to reduction of the >C=O double bond of the analyte molecule. Adsorption of tolmetin onto the surface of the hanging mercury electrode was identified and each adsorbed tolmetin molecule was found to occupy an area of 0.23 nm2. A square-wave adsorptive cathodic stripping voltammetric procedure was described for the direct determination of tolmetin in bulk form and pharmaceutical formulation (Rumatol® capsules) with a limit of quantitation of 2 × 10?9 M and a mean percentage recovery of 98.35 ± 1.21% to 99.57 ± 1.23. Moreover, the described procedure was successfully applied for the direct assay of tolmetin in spiked human serum without pretreatment or extraction prior to the analysis while a quantitation limit of 5 × 10?9 M tolmetin was achieved.   相似文献   

6.
《Analytical letters》2012,45(9):1750-1762
Abstract

The interaction between clozapine (CLZ) as an orally administrated antipsychotic drug with double stranded calf thymus DNA (dsDNA) was investigated at electrode surface using differential pulse voltammetry (DPV). Activated carbon paste electrode (CPE) was modified with dsDNA and used for monitoring the changes of the characteristics peak of CLZ in 0.05 M acetate buffer (pH 4.3). The adsorptive stripping voltammetry on dsDNA‐modified carbon paste electrode (dsDNA‐CPE) was used for determination of very low concentration of CLZ. Under optimal conditions, the oxidation peak current is proportional to CLZ concentration in the range of 7×10?9?1.2×10?6 mol l?1 with a detection limit of 1.5×10?9 mol l?1 for 180 s accumulation time by DPV. The proposed dsDNA‐CPE was successfully used for determination of CLZ in human serum samples with recovery of 97.0±2.5%.  相似文献   

7.
Controlled adsorptive accumulation at the hanging mercury drop electrode enables 0.8–11 × 10?5 M chlordiazepoxide to be quantified by differential-pulse stripping voltammetry with accumulation times of 1–3 min. With 3-min accumulation, the peak current is enhanced 12-fold for 1.0 × 10?7 M chlordiazepoxide compared to the current from differential pulse polarography. The detection limit is 0.9 × 10?9 M for 4-min accumulation. The procedure is applied to spiked human serum after preseparation of the drug on a Sep-Pak C18 cartridge.  相似文献   

8.
The in situ plated lead film electrode was proposed for the first time for adsorptive stripping voltammetric determination of gallium in water samples. The method was based on simultaneous lead film formation and Ga(III)‐cupferron complex preconcentration at ?0.7 V and its cathodic stripping during the potential scan. The composition of the supporting electrolyte, cupferron concentration, conditions of lead film formation, potential and time of accumulation were studied in detail. Under optimum conditions the limit of detection was 3.8×10?9 mol L?1. The proposed procedure was validated in the course of Ga(III) determination in waste water certified reference materials.  相似文献   

9.
《Analytical letters》2012,45(6):1143-1158
Abstract

A sensitive and reliable stripping voltammetry method was developed to determine the presence of Ceftiofur antibiotic drug. This method is based on the adsorptive accumulation of the drug at a hanging mercury drop electrode and then the initiation of a negative sweep that yielded well‐defined cathodic peaks at ?0.65 V (1 C) and ?1.00 V (2 C) vs. Ag/AgCl reference electrode. To achieve high sensitivity, various experimental and instrumental variables were investigated such as supporting electrolyte, pH, accumulation time and potential, drug concentration, scan rate, convection rate, and working electrode area. The monitored adsorptive current of peak 1 C was directly proportional to the concentration of Ceftiofur; it shows a linear response in the range from 0.50×10?8 to 8.00×10?8 mol L?1 (correlation coefficient=0.998); and the limit of detection is 6.00×10?10 mol L?1 at an accumulation time of 300 s. The applicability of this approach was illustrated by the determination of Ceftiofur in pharmaceutical preparations and bovine serum.  相似文献   

10.
We report on the design of a UO22+‐selective electrode based on the use of UO22+ imprinted polymer nanoparticles (IP‐NPs), and its application for the differential pulse adsorptive cathodic stripping voltammetry determination of uranyl ions. A carbon paste electrode was modified with the IP‐NPs, and differential pulse adsorptive cathodic stripping voltammetry was applied as the detection technique after open‐circuit sorption of UO22+ ions. The modified electrode responses to UO22+ was linear in the 0.1 µg L?1 to 10 µg L?1 and in the 0.01 mg L?1 to 10 mg L?1. The method detection limit of the sensor was 0.03 µg L?1.  相似文献   

11.
《Electroanalysis》2006,18(2):158-162
Optimum conditions have been found for voltammetric determination of mutagenic 5‐aminoquinoline, 6‐aminoquinoline and 3‐aminoquinoline by differential pulse voltammetry and adsorptive stripping differential pulse voltammetry on carbon paste electrode. The lowest limits of determination were found for adsorptive stripping differential pulse voltammetry in 0.1 mol dm?3 H3PO4 (5×10?7 mol dm?3 , 1×10?7 mol dm?3, and 1×10?7 mol dm?3 for 5‐aminoquinoline, 6‐aminoquinoline and 3‐aminoquinoline, respectively). The possibility to determine mixtures of 8‐aminoquinoline with 3‐aminoquinoline or 5‐aminoquinoline or 6‐aminoquinoline, and mixtures of 5‐aminoquinoline with 3‐aminoquinoline or 6‐aminoquinoline by differential pulse voltammetry was verified. Binary mixtures of 8‐aminoquinoline with 3‐aminoquinoline or 6‐aminoquinoline, and of 3‐aminoquinoline with 5‐aminoquinoline could be successfully analyzed.  相似文献   

12.
The adsorptive stripping voltammetry of telmisartan was investigated with a hanging mercury drop electrode. This compound produced a catalytic hydrogen wave at ?1.5 V in Britton Robinson buffer of pH 10.38, and the peak current increased with adsorptive accumulation at the electrode. Adsorptive stripping voltammetry with the catalytic hydrogen wave could provide a sensitive novel method for the determination of telmisartan. Various chemical and instrumental parameters affecting the monitored electroanalytical response were investigated and optimized for telmisartan determination. Under these optimized conditions the square-wave adsorptive stripping voltammetric (SW-AdSV) peak current showed a linear dependence on drug concentration over the range 0.05–3.00 μg/mL (1 × 10?7?6 × 10?6 M) (r = 0.999) with accumulation for 120 s at ?1.0 V vs. Ag/AgCl. The proposed electrochemical procedure was successfully applied for the determination of telmisartan in pharmaceutical tablets and human plasma. The results of the developed SW-AdSV method were comparable with those obtained by reported analytical procedures.  相似文献   

13.
Differential pulse cathodic adsorptive stripping (DPCAdSV) and square wave cathodic adsorptive stripping (SWCAdSV) voltammetric methods were developed for the determination of antimony and lead in gunshot residues. Linear working ranges for DPCAdSV and SWCAdSV methods were (2.0×10?9–5.0×10?7) M and (2.0×10?9–7.0×10?7) M for antimony and 2.0×10?9–3.0×10?7 M (both methods) for lead. The detection of antimony limits were found to be 1.3×10?9 M for DPCAdSV and 7.3×10?10 M for SWCAdSV while the corresponding values for lead were 3.0×10?9 M and 5.8×10?10 M. Antimony and lead contents obtained by these methods in gunshot residues are in good agreement with those obtained by graphite furnace atomic absorption spectrometric method within a confidence limit of 95%.  相似文献   

14.
The adsorption behavior and differential pulse cathodic adsorptive stripping voltammetry of the pesticide Chlorpyrifos (CP) were investigated at the hanging mercury drop electrode (HMDE). The pesticide was accumulated at the HMDE and a well-defined stripping peak was obtained at –1.2 V vs Ag/AgCl electrode at pH 7.50. A voltammetric procedure was developed for the trace determination of Chlorpyrifos using differential pulse cathodic adsorptive stripping voltammetry (DP-CASV). The optimum working conditions for the determination of the compound were established. The peak current was linear over the concentration range 9.90 × 10–8– 5.96 × 10–7 mol/L of Chlorpyrifos. The influence of diverse ions and some other pesticides was investigated. The analysis of Chlorpyrifos in commercial formulations and treated waste water was carried out satisfactorily  相似文献   

15.
Ghoneim MM  Beltagi AM 《Talanta》2003,60(5):911-921
Celecoxib is a cyclooxygenase inhibitor, that has been recently and intensively prescribed as an anti-inflammatory drug in rheumatic osteoarthiritis. A robust, highly reliable and reproducible square-wave (SW) adsorptive cathodic stripping voltammetric procedure was developed for the determination of celecoxib in pharmaceutical formulation and human serum. The analytical procedure was based on the reduction of the CN of the pyrazole ring of the drug molecule at the mercury electrode surface in Britton-Robinson buffer of pH 7.0. The SW adsorptive cathodic stripping voltammogram of celecoxib showed a single well-defined peak at −1.54 V (vs. Ag/AgCl/KCls) using an accumulation potential of −0.70 V, frequency of 120 Hz, scan increment of 10 mV and pulse amplitude of 25 mV. Repeatability was examined for 1×10−8 M CXB drug solution after 30 s pre-concentration and a mean recovery of 99.4±0.4% (n=5) was achieved. For 90 s preconcentration, a linear concentration range of 1×10−9-2×10−8 M CXB and a detection limit of 1.86×10−10 M were achieved. The proposed procedure was successfully applied for the determination of the drug in capsules and human serum with mean recoveries of 101.5±0.6 and 98.8±1.1%, respectively. A detection and quantitation limits of 1.0×10−9 M (0.4 ng ml−1) and 4.7×10−9 M (1.3 ng ml−1) were achieved for the determination of the drug in human serum. Moreover, the procedure was useful for study of the pharmacokinetic profile of celecoxib in a healthy volunteer after administration of a single oral dose (celebrex®, 200 mg).  相似文献   

16.
WANG Yuane  PAN Dawei  LI Xinmin  QIN Wei 《中国化学》2009,27(12):2385-2391
A bismuth/multi‐walled carbon nanotube (Bi/MWNT) composite modified electrode for determination of cobalt by differential pulse adsorptive cathodic stripping voltammetry is described. The electrode is fabricated by potentiostatic pre‐plating bismuth film on an MWNT modified glassy carbon (GC) electrode. The Bi/MWNT composite modified electrode exhibits enhanced sensitivity for cobalt detection as compared with the bare GC, MWNT modified and bismuth film electrodes. Numerous key experimental parameters have been examined for optimum analytical performance of the proposed electrode. With an adsorptive accumulation of the Co(II)‐dimethylglyoxime complex at ?0.8 V for 200 s, the reduction peak current is proportional to the concentration of cobalt in the range of 4.0×10?10?1.0×10?7 mol/L with a lower detection limit of 8.1×10?11 mol/L. The proposed method has been applied successfully to cobalt determination in seawater and lake water samples.  相似文献   

17.
《Electroanalysis》2005,17(22):2074-2083
Carvedilol is used in the management of hypertension and angina pectoris and as an adjunct to standard therapy in symptomatic heart failure. The electrochemical oxidation of carvedilol was investigated using cyclic, linear sweep voltammetry at a glassy carbon electrode. In cyclic voltammetry, in all values of pH, the compound shows two irreversible oxidation peaks. These two peaks are related to the different electroactive part of the molecule. First and second peak currents were found as diffusion and adsorption controlled, respectively. Using second oxidation step, two voltammetric methods were described for the determination of carvedilol by differential pulse adsorptive stripping voltammetry (AdSDPV) and square‐wave adsorptive stripping voltammetry (AdSSWV) at a glassy carbon electrode. Accumulation of carvedilol was found to be optimized in 0.2 M H2SO4 solution following 275 second accumulation time at open circuit condition. Under optimized conditions, the current showed a linear dependence with concentration in the range between 2×10?7 M and 2×10?5 M in supporting electrolyte and in the range between 2×10?7 M and 1×10?5 M in spiked human serum samples for both methods. These methods were successfully applied for the analysis of carvedilol pharmaceutical dosage forms and spiked human serum samples. The repeatability and reproducibility of the methods for all media were determined. Precision and accuracy were also found. No electroactive interferences from the tablet excipients and endogenous substances from biological material were found.  相似文献   

18.
《Analytical letters》2012,45(17):3021-3033
Abstract

The electrochemical reduction of cinnarizine was investigated by cyclic and linear sweep adsorptive voltammetry at glassy carbon electrode in Britton-Robinson buffers over the pH range 2.5–11.5. For analytical purposes, a well-defined adsorption-controlled cathodic peak was obtained at pH 2.5. By cathodic adsorptive linear sweep voltammetry, a linear calibration plot was obtained in the range of 2.0 × 10?7 to 5.0 × 10?6 mol L?1 with detection limit of 9.0 × 10?9 mol L?1. The method was successfully applied to the determination of cinnarizine in commercial formulations with mean recovery and relative standard deviation of 100.24% and 1.46, respectively. The proposed method was also applied for drug determination in spiked serum samples by applying the standard addition method with a mean recovery of 97.80% and standard deviation of 3.06.  相似文献   

19.
《Analytical letters》2012,45(6):1085-1097
Abstract

A methodology for the determination of the pesticide chlorfenvinphos by microwave‐assisted solvent extraction and square‐wave cathodic stripping voltammetry at a mercury film ultramicroelectrode in soil samples is proposed. Optimization of microwave solvent extraction performed with two soils, selected for having significantly different properties, indicated that the optimum solvent for extracting chlorfenvinphos is hexane‐acetone (1∶1, v/v). The voltammetric procedure is based on controlled adsorptive accumulation of the insecticide at the potential of?0.60 V (vs. Ag/AgCl) in the presence of Britton‐Robinson buffer (pH 6.2). The detection limit obtained for a 10 s collection time was 3.0×10?8 mol l?1. The validity of the developed methodology was assessed by recovery experiments at the 0.100 µg g?1 level. The average recoveries and standard deviations for the global procedure reached by MASE‐square‐wave voltammetry were 90.2±2.8% and 92.1±3.4% for type I (soil rich in organic matter) and type II (sandy soil) samples, respectively. These results are in accordance to the expected values which show that the method has a good accuracy.  相似文献   

20.
A simple adsorptive cathodic stripping voltammetry method has been developed for antimony (III and V) speciation using 4‐(2‐thiazolylazo) – resorcinol (TAR). The methodology involves controlled preconcentration at pH 5, during which antimony(III) – TAR complex is adsorbed onto a hanging mercury drop electrode followed by measuring the cathodic peak current (Ip,c) at ?0.39 V versus Ag/AgCl electrode. The plot of Ip,c versus antimony(III) concentration was linear in the range 1.35×10?9–9.53×10?8 mol L?1.The LOD and LOQ for Sb(III) were found 4.06×10?10 and 1.35×10?9 mol L?1, respectively. Antimony(V) species after reduction to antimony(III) with Na2SO3 were also determined. Analysis of antimony in environment water samples was applied satisfactorily.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏