首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
In order to identify new biomarkers for pulmonary diseases in exhaled breath condensate (EBC) it was the aim of this study to develop an analytical method for the identification and quantification of N epsilon-(carboxymethyl)lysine (CML) in EBC. As detection by liquid chromatography with positive electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) offers the advantage of structurally related detection with the necessary specificity required for the identification of a substance, it was the method chosen for the determination of the non-volatile compound. Specific mass transitions and comparison of retention times with standards under given conditions were used for the unequivocal identification of CML in EBC of healthy subjects. Synthesis of isotopically labelled CML was performed and used as an internal standard for an accurate determination. It was possible to identify the advanced glycation end-product CML in 8 out of 10 healthy subjects. The concentration range determined in the quantifiable examined samples ranged between 35 and 110 pg/mL. EBC samples from 11 patients with different diseases such as diabetes and chronic obstructive pulmonary disease were also measured. In one patient with pneumonia a concentration of 1509 pg CML/mL EBC could be detected. This is the first time that CML has been identified and determined in EBC. The developed LC/ESI-MS/MS method could be used to address the utility of CML as a biomarker in pulmonary diseases.  相似文献   

3.
A method for the simultaneous determination of several classes of aldehydes in exhaled breath condensate (EBC) was developed using liquid chromatography/atmospheric pressure chemical ionization tandem mass spectrometry (LC/APCI-MS/MS). EBC is a biological matrix obtained by a relatively new, simple and noninvasive technique and provides an indirect assessment of pulmonary status. The measurement of aldehydes in EBC represents a biomarker of the effect of oxidative stress caused by smoke, disease, or strong oxidants like ozone. Malondialdehyde (MDA), acrolein, alpha,beta-unsaturated hydroxylated aldehydes [namely 4-hydroxyhexenal (4-HHE) and 4-hydroxynonenal (4-HNE)], and saturated aldehydes (n-hexanal, n-heptanal and n-nonanal) were measured in EBC after derivatization with 2,4-dinitrophenylhydrazine (DNPH). Atmospheric pressure chemical ionization of the analytes was obtained in positive-ion mode for MDA, and in negative-ion mode for acrolein, 4-HHE, 4-HNE, and saturated aldehydes. DNPH derivatives were separated on a C18 column using variable proportions of 20 mM aqueous acetic acid and methanol. Linearity was established over 4-5 orders of magnitude and limits of detection were in the 0.3-1.0 nM range. Intra-day and inter-day precision were in the 1.3-9.9% range for all the compounds. MDA, acrolein and n-alkanals were detectable in all EBC samples, whereas the highly reactive 4-HHE and 4-HNE were found in only a few samples. Statistically significant higher concentrations of MDA, acrolein and n-hexanal were found in EBC from smokers.  相似文献   

4.
A sensitive liquid chromatography/ion trap tandem mass spectrometry method was developed for the qualitative and quantitative detection of isocyanates in air. The method is based on derivatization of isocyanates with 1-(2-methoxyphenyl)piperazine during air sampling. The extracts are analyzed using an ion trap LC/MS system equipped with an electrospray (ESI) ion source. The method shows high linearity, specificity, accuracy and precision. The limits of detection are 40x to 55x lower than with UV-based methods.  相似文献   

5.
Collection of exhaled breath condensate (EBC) is a relatively simple noninvasive method of breath analysis; however, no data have been reported that would relate concentration of volatile compounds in EBC to their gaseous concentrations in exhaled air. The aim of the study was to investigate which volatile compounds are present in EBC and how their concentrations relate to results of direct breath analysis. Thus, samples of EBC were collected in a standard way from several subjects and absolute levels of several common volatile breath metabolites (ammonia, acetone, ethanol, methanol, propanol, isoprene, hydrogen cyanide, formaldehyde and acetaldehyde) were then determined in their headspace using selected ion flow tube mass spectrometry (SIFT-MS). Results are compared with those from on-line breath analyses carried out immediately before collecting the EBC samples. It has been demonstrated that SIFT-MS can be used to quantify the concentrations of volatiles in EBC samples and that, for methanol, ammonia, ethanol and acetone, the EBC concentrations correlate with the direct breath levels. However, the EBC concentrations of isoprene, formaldehyde, acetaldehyde, hydrogen cyanide and propanol do not correlate with direct breath measurements. Copyright (c) 2008 John Wiley & Sons, Ltd.  相似文献   

6.
High-throughput chiral liquid chromatography/tandem mass spectrometry   总被引:3,自引:0,他引:3  
Chiral liquid chromatography is a well-established area of bioanalytical chemistry and is often used during the processes of drug discovery and development. The development and use of a chiral drug require the understanding of the pharmacokinetic characteristics of each of the enantiomers, including potential differences in their absorption, distribution, metabolism, and excretion. Chromatographic techniques coupled to atmospheric pressure ionization-tandem mass spectrometry have shown potential as sensitive and robust tools in the quantitative and qualitative determination of enantiomers in biologic fluids and tissue extracts. However, development of a chiral liquid chromatography method requires time-consuming procedures that are devised empirically. Clearly, there is an incentive to design chromatographic approaches that are easy to use, compatible with mass spectrometry ionization interface conditions, exhibit relatively short run times without compromising sensitivity, and offer a broad analyte specificity. For these reasons, the present paper explores the feasibility of the bonded macrocyclic glycopeptide phases (teicoplanin and vancomycin) for analysis by chiral liquid chromatography/tandem mass spectrometry. Ritalinic acid, pindolol, fluoxetine, oxazepam, propranolol, terbutaline, metoprolol, and nicardipine were tested in this study. Furthermore, an example of a simultaneous chiral LC/MS/MS detection (chromatographic run time approximately 10 min) of four pharmaceutical products resulting in baseline resolutions of all four pairs of enantiomers is presented. Methanol, an MS-compatible mobile phase, was utilized in all the experiments.  相似文献   

7.
This paper describes the development of a high performance liquid chromatography/tandem mass spectrometric (MS/MS) procedure for the specific qualitative and quantitative analysis of lipid aldehydes in biological matrices. A derivatisation method, which results in molecules that exhibit a common product ion on MS/MS, permits informative precursor ion scans, at high sensitivity. This has been applied to the examination of plasma in order to examine the production of aldehydes consequent on in vitro lipid oxidation. Quantitative analysis of target molecules using multiple reaction monitoring has been developed to permit quantitation in the same matrices.  相似文献   

8.
In this study, we benefit from the combination of liquid chromatography (LC)/time-of-flight (TOF) MS accurate mass measurements to generate elemental compositions of ions and LC/ion trap multiple MS (MSn) providing complementary structural information, which is useful for the elucidation of unknown organic compounds at trace levels in complex food extracts. We have applied this approach to investigate different citrus fruits extracts, and we have identified two post-harvest fungicides (imazalil and prochloraz), the main degradation product of imazalil ([M + H]+, m/z 257) and a non-previously reported prochloraz degradation product ([M + H]+, m/z 282). The database-mediated identification of the parent compounds was based on the generated elemental composition obtained from accurate mass measurements and additional qualitative information from the high resolution chlorine isotopic clusters of both the protonated molecules (imazalil, [M + H]+ 297.0556, <0.1 ppm error, 2-Cl; prochloraz, [M + H]+ 376.0381, 1.9 ppm error, 3-Cl) and their characteristic fragments ions (imazalil: m/z 255 and 159; prochloraz: m/z 308 and 266). The correlation between the structural information provided by ion trap MS/MS fragmentation pathways of the parent species and the TOF accurate mass elemental composition data of the degradation products were the key to elucidate the structures of the degradation products of both post-harvest fungicides. Finally, where standards were not available (prochloraz), further confirmation was obtained by synthesizing the proposed degradation product by acid hydrolysis of the parent standard and confirmation by LC/TOF-MS.  相似文献   

9.
Tomato (Lycopersicon esculentum Mill.) is the second most important fruit crop worldwide. Tomatoes are a key component in the Mediterranean diet, which is strongly associated with a reduced risk of chronic degenerative diseases. In this work, we use a combination of mass spectrometry (MS) techniques with negative ion detection, liquid chromatography/electrospray ionization linear ion trap quadrupole‐Orbitrap‐mass spectrometry (LC/ESI‐LTQ‐Orbitrap‐MS) and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) on a triple quadrupole, for the identification of the constituents of tomato samples. First, we tested for the presence of polyphenolic compounds through generic MS/MS experiments such as neutral loss and precursor ion scans on the triple quadrupole system. Confirmation of the compounds previously identified was accomplished by injection into the high‐resolution system (LTQ‐Orbitrap) using accurate mass measurements in MS, MS2 and MS3 modes. In this way, 38 compounds were identified in tomato samples with very good mass accuracy (<2 mDa), three of them, as far as we know, not previously reported in tomato samples. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

10.
The structural characterization of proteins and peptides isolated in minute quantities requires the most efficient use of available sample. A mass spectrometer data system was programmed to continuously evaluate incoming liquid chromatography/mass spectrometry data against a user-defined array of information. The resulting conclusions were used to automatically set and modify acquisition parameters in real time to collect collision-induced dissociation spectra for selected ions (tandem mass spectrometry). This approach has provided a mechanism to target specific subsets of masses in a complex mixture and/or to discriminate selectively against masses that are known or not of interest. Masses of contaminants or peptide masses derived from known proteins can be automatically recorded and removed from further consideration for collision-induced dissociation analysis. Once recorded, these “libraries” of masses can be used across multiple analyses. This technique directs the mass spectrometer data system to focus on the analysis of masses significant to the user, even if their signal intensities are well below the intensities of contaminating masses. When combined with a database search program to correlate tandem mass spectra to known protein sequences, the identity of the protein can be established unequivocally by using less than 100 fmol of sample.  相似文献   

11.
A congener-specific method based on high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC/ES-MS/MS) in the negative ion mode was developed for the analysis of hexabromocyclododecane (HBCDD). On a C(18) analytical column, with a methanol/water mobile phase, the alpha-isomer was completely resolved from the beta- and gamma-isomers while the beta- and gamma-isomers were sufficiently resolved at half their peak heights. The ES spray voltage strongly influenced the intensity of the ion signal. For MS, a source temperature of 500 degrees C and a collision energy of 50 eV were found to be optimum for the [M-H](-) to Br(-) transition. Run-to-run and day-to-day (n = 3) variability was minimal, with relative standard deviations of 2.6-4.1 and 2.4-4.4%, respectively. The limit of detection was 4-6 pg on-column. When applied to tissue samples from Lake Winnipeg fish both alpha- and gamma-isomers of HBCDD were found in low-ng/g (lipid corrected) concentrations.  相似文献   

12.
The fragmentation pathways of three explosive compounds with similar structures, hexanitrostilbene (HNS), cyclotrimethylene trinitramine (RDX), and 2,4,6-trinitrotoluene (TNT), have been investigated by multiple mass spectrometry (MSn, n = 1, 2, 3) with electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) sources. The electron capture mechanism for these compounds in negative ion APCI and ESI mode differs from the usual negative ion mechanism, deprotonation or addition of other species. This was shown for HNS and TNT, which both gave a [M]- anion but not a [M-H]- ion in APCI, and the [M]- anion of HNS was observed in ESI. The quantitative analysis of HNS was performed by liquid chromatography (LC)/ESI-MS, and the results obtained by the internal standard (ISTD) method were compared with those from the external standard (ESTD) method, demonstrating that both quantitation approaches are useful, with good sensitivity, reproducibility and linearity, and ESTD is preferable in routine applications.  相似文献   

13.
Fatty acid amides are a class of compounds with newly discovered biological activity. The ion trap mass spectrometric characteristics of silylated fatty acid amides were examined. Silylation of primary fatty acid amides is required prior to gas chromatography owing to thermal instability of the underivatized compound. The trimethylsilylated amides do not yield a molecular ion under normal electron ionization conditions (70 eV). With methane as a chemical ionization gas, the [M+H]+ ion appears. The [M+H]+ ion also appears when the helium buffer gas pressure is increased in the ion trap. There are three fragments other than the [M+H]+ peak that are predominant in the ion trap mass spectra of these compounds. Two of the fragments have been reported previously, namely the m/z 59 and the [M-71]+ fragments. The fragment of m/z 72 was identified and is the result of a rearrangement. Isotopic labeling was used to confirm fragment identity and the composition of the rearrangement products. Fragmentation patterns were affected by the amide chain length and concentration.  相似文献   

14.
A simple multiresidue analysis method was developed for the confirmation and quantification of eprinomectin, abamectin, doramectin, and ivermectin in cattle liver. The target analytes were extracted with acetonitrile and cleaned up with C18 and C8 solid-phase extraction cartridges before analysis by liquid chromatography combined with positive ion electrospray tandem mass spectrometry. The residue mean recoveries of the 4 drugs were 64.16-99.53%. The limit of detection was 2.5 ng/g for eprinomectin, abamectin, doramectin, and ivermectin.  相似文献   

15.
The characterization of unknown impurities present in neomycin sulfate by liquid chromatography (LC) coupled with ion trap mass spectrometry (ITMS) is described. The volatile LC method was developed using an evaporative light scattering detector due to its lower investment and operating costs, easier operation and less maintenance than mass spectrometry. The method shows separation of neomycin B from seven potential related substances reported in the European Pharmacopoeia and several other unknown impurities. The unknown impurities were further investigated by coupling the developed LC method with ITMS. Their structures were deduced based on the fragmentation patterns obtained from reference substances. Four unknowns were identified as isomers of paromamine, LP-A, neamine and LP-B.  相似文献   

16.
Liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is one of the most prominent analytical techniques owing to its inherent selectivity and sensitivity. In LC/ESI-MS/MS, chemical derivatization is often used to enhance the detection sensitivity. Derivatization improves the chromatographic separation, and enhances the mass spectrometric ionization efficiency and MS/MS detectability. In this review, an overview of the derivatization reagents which have been applied to LC/ESI-MS/MS is presented, focusing on the applications to low molecular weight compounds.  相似文献   

17.
The review discusses the pitfalls of the matrix effect in mass spectrometry detection hyphenated to liquid chromatography separation. Matrix effect heavily influences both qualitative and quantitative analyses, giving rise to suppression or enhancement of the signal. As generally recognised, the predominant cause is the presence of undesired components that co-elute in the chromatographic separation and alter the ionisation process. The interfering species can be components of the sample, compounds released during the pre-treatment/extraction process or reagents added to the mobile phase to improve chromatographic resolution. The different mechanisms proposed in literature to explain the suppression or the enhancement of the signal both in electrospray and atmospheric pressure chemical ionisations are presented and the results observed in the different experimental conditions are compared and discussed. All data together lead to conclude that the chemical properties of the target analyte, the kind of matrix, the matrix to analyte concentration ratio, the extraction process, the chromatographic conditions as well as the kind of the mass spectrometry instrumentation and the ionisation conditions can play a role. Likely all these potential causes act in a synergic way and the final effect observed is hardly due to only one of them. Depending on an unpredictable combination of conditions, signal suppression or enhancement can be observed. The review discusses the matrix effects observed in HPLC–MS and HPLC–MS/MS analysis proposes hypotheses to explain the observed behaviours and proposes methods and strategies to overcome the matrix effects.  相似文献   

18.
Optimal liquid chromatography/mass spectrometric [LC/MS(/MS)] analysis depends on both the LC selectivity and the electrospray efficiency. Here, we outline a simple and comprehensive LC/MS/MS strategy for the rapid analysis of a wide range of pharmaceutical compounds. To achieve ultrafast LC separation with little sacrifice in peak capacity, one needs to start with a column that provides a good peak capacity at short gradient run times; secondly, it is important to use high flow rates to achieve a good gradient peak capacity. Following this strategy, it was possible to baseline-resolve a mixture (containing acidic, neutral, and basic pharmaceutical analytes) in seconds. By coupling the selectivity provided by fast LC separation with the specificity of MS/MS detection, it is possible to separate and identify a wide range of analytes in 1-min gradient analyses. Also, the impact of mobile phase pH on both the chromatographic selectivity and the MS/MS sensitivity is demonstrated.  相似文献   

19.
A sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for determining the type B fumonisin mycotoxins in corn-based foodstuffs is described. Fumonisins FB1 and FB2 were extracted from a 1 g sample by homogenization with acetonitrile/water (75:25, v/v, 50 mmol/L formic acid, 25 mL final volume) and the extract was defatted on C18 phase. Volumes of 5 mL of crude extracts were cleaned up on Carbograph-4 cartridges. The final solution was analyzed by HPLC with electrospray ionization mass spectrometry in positive ion mode using multiple reaction monitoring with a QqQ linear ion trap mass spectrometer. Recoveries for spiked corn-based foodstuffs ranged from 91-105% (RSD% < or =8%), and method detection limits were < or =2 ng/g for FB1 and < or =1 ng/g for FB2. Two different spiking levels were tested (5000 and 100 ng/g for FB1, 1000 and 20 ng/g for FB2). Quantitation was achieved by an external calibration procedure using matrix-matched standards, with diclofenac added post-cleanup as internal standard for the LC/MS/MS analyses. Calibration curves showed linearity in the concentration range 0.005-5 ng/microL of final extract (0.992 < or = R2< or =0.995). Two other fumonisins, FB3 and FB4, were identified in naturally contaminated samples of corn meal using an information-dependent acquisition protocol that looped three experiments, including neutral loss scan, enhanced resolution scan, and enhanced product ion scan. FB3 and FB4 quantitation was estimated as peak area ratios relative to the FB2 response in view of the lack of both standards. This work also includes an application of the present LC/MS/MS method to some maize and maize-based product samples (corn meal, cornflakes and popcorn) collected from Italian stores. FB1 and FB2 contamination levels exceeding the European Union recommendation were found in 8 out of 15 corn meal samples.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏