首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Purpose

To evaluate MRI artifacts at 3-Tesla for 38 commonly used cosmetics.

Materials and Methods

Thirty-eight cosmetics (16, nail polishes; 5, eyeliners; 3, mascaras; 10, eye shadows; 1, lip gloss; 1, body lotion; 1, body glitter, and 1, hair loss concealer) underwent evaluation for MRI artifacts at 3-Tesla. The cosmetics were applied a copper-sulfate-filled, phantom and initially assessed using a “screening” gradient echo (GRE) pulse sequence. Of the 38 different cosmetics, 14 (37%) exhibited artifacts. For these 14 cosmetics, additional characterization of artifacts was performed using a GRE pulse sequence. A qualitative scale was applied to characterize the artifact size.

Results

Artifacts were observed, as follows: 2, nail polishes; 5, eyeliners; 3, mascaras; 3, eye shadows; 1, hair loss concealer. Artifact size ranged from small (eye shadow) to very large (hair loss concealer) and tended to be associated with the presence of iron oxide or other metal-based ingredient.

Conclusions

Commonly used cosmetics caused artifacts that may create issues if the area of interest is the same as where the cosmetic was applied or if its presence was unknown, thus, potentially causing it to be construed as pathology. Therefore, these findings have important implications for patients referred for MRI examinations.  相似文献   

2.
To prevent systematic errors in quantitative brain perfusion studies using dynamic susceptibility contrast-enhanced magnetic resonance imaging (DSC-MRI), a reliable determination of the arterial input function (AIF) is essential. We propose a novel algorithm for correcting distortions of the AIF caused by saturation of the peak amplitude and discuss its relevance for longitudinal studies. The algorithm is based on the assumption that the AIF can be separated into a reliable part at low contrast agent concentrations and an unreliable part at high concentrations. This unreliable part is reconstructed, applying a theoretical framework based on a transport-diffusion theory and using the bolus-shape in the tissue. A validation of the correction scheme is tested by a Monte Carlo simulation. The input of the simulation was a wide range of perfusion, and the main aim was to compare this input to the determined perfusion parameters. Another input of the simulation was an AIF template derived from in vivo measurements. The distortions of this template was modeled via a Rician distribution for image intensities. As for a real DSC-MRI experiment, the simulation returned the AIF and the tracer concentration-dependent signal in the tissue. The novel correction scheme was tested by deriving perfusion parameters from the simulated data for the corrected and the uncorrected case. For this analysis, a common truncated singular value decomposition approach was applied. We find that the saturation effect caused by Rician-distributed noise leads to an overestimation of regional cerebral blood flow and regional cerebral blood volume, as compared to the input parameter. The aberration can be amplified by a decreasing signal-to-noise ratio (SNR) or an increasing tracer concentration. We also find that the overestimation can be successfully eliminated by the proposed saturation-correction scheme. In summary, the correction scheme will allow DSC-MRI to be expanded towards higher tracer concentrations and lower SNR and will help to increase the measurement to measurement reproducibility for longitudinal studies.  相似文献   

3.
PURPOSE: The aim of this experimental study was to evaluate the potential of a simple expiration technique by means of magnetic resonance imaging (MRI) in an animal model to detect pulmonary air-trapping areas after artificial bronchial obstruction. MATERIAL AND METHODS: Sixteen pigs were evaluated by means of a modified T1-weighted FLASH with fat saturation in respiratory arrest (TR=4.6 ms, TE=1.8 ms, alpha=10 degrees, S.D.=3-5 mm). A measurement of the signal intensity (SI) in the peripheral lung tissue was made in both inspiration and expiration before and after inhalation of 2 ml of 0.5% acetylcholine to simulate a bronchial obstruction. A final measurement of the lung SI was also made after bronchospasmolytic induction through salbutamol (beta2-mimetic bronchodilator). RESULTS: In expiration, a mean SI increase in peripheral lung tissue of about 183% was seen in comparison to inspiration (mean SI increase of 11-32). After inhalation of 0.5% acetylcholine, the expirational signal increase in peripheral lung tissue was only 114% of the original SI. The expirational signal homogeneity decreased after inhalation of acetylcholine. After inhalation of salbutamol, the lung tissue signal elevation in expiration was 193%. CONCLUSION: We interpret the low expiratory signal elevation after acetylcholine inhalation as a result of an air-trapped bronchial constriction in certain areas. The simple expiratory technique in an animal model showed that it is suitable to demonstrate obstructive air trapping using MRI.  相似文献   

4.
The purpose of this study was to determine the feasibility of diffusion-weighted magnetic resonance imaging (DWI) for detecting colorectal polyps. DWI (high b-value of 1000 s/mm2) was prospectively performed in 26 symptomatic patients who were scheduled to undergo colonoscopy. DWI and colonoscopic findings were interpreted in a blinded manner. The sensitivity and positive predictive value (PPV) of DWI for the detection of clinically relevant polyps (≥ 6 mm) and colorectal cancer (CRC) were calculated on a per-lesion basis, using colonoscopy results as the standard of reference. Sensitivity, specificity, PPV and negative predictive value (NPV) on a per-patient basis were also calculated. Sensitivity and PPV on a per-lesion basis were 80.0% [95% confidence interval (CI): 49.0%–94.3%] and 72.7% (95% CI: 43.4%–90.3%) for polyps ≥ 6 mm and CRC. Sensitivity, specificity, PPV and NPV on a per-patient basis were 85.7% (95% CI: 48.7%–97.4%), 84.2% (95% CI: 62.4%–94.5%), 66.7% (95% CI: 35.4%–87.9%) and 94.1% (95% CI: 73.0%–99.0%) for polyps ≥ 6mm and CRC. In conclusion, DWI cannot yet be recommended in a clinical setting in which DWI is performed first and subsequent colonoscopy is only performed in patients with positive findings at DWI. Further (technical) developments are required to increase its diagnostic yield.  相似文献   

5.
Following nephrectomy and intravenous injection of tritiated mannitol, adult male rats were exposed to magnetic resonance imaging (MRI) procedures at 1.5 T, 0.5 T, and 0.3 T. Compared to rats similarly handled but not exposed to MRI procedures, brain mannitol concentration, expressed as a percentage of mean body concentration, was significantly increased at 0.3 T and 0.5 T but not at 1.5 T. At 0.3 T, exposure to gradient-field fluctuations used for imaging increased brain mannitol concentration, but exposures to static main field and pulsed radiofrequency energies did not. Increased brain mannitol associated with gradient-field flux may reflect increased blood-brain barrier permeability or blood volume in brain. MRI effects on brain mannitol space are of uncertain clinical significance, but are consistent with prior evidence of an MRI-induced increase of brain capillary endothelial cell transport observed with horseradish peroxidase. Further studies are needed to confirm these findings and to explore the processes underlying changes in mannitol distribution related to MRI.  相似文献   

6.
OBJECTIVES: The objectives of this study were to develop protocols that measure abdominal fat and calf muscle lipids with magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS), respectively, at 3 T and to examine the correlation between these parameters and insulin sensitivity. MATERIALS AND METHODS: Ten nondiabetic subjects [five insulin-sensitive (IS) subjects and five insulin-resistant (IR) subjects] were scanned at 3 T. Visceral adipose tissue (VAT) and subcutaneous adipose tissue (SAT) were segmented semiautomatically from abdominal imaging. Intramyocellular lipids (IMCL) in calf muscles were quantified with single-voxel MRS in both soleus and tibialis anterior muscles and with magnetic resonance spectroscopic imaging (MRSI). RESULTS: The average coefficient of variation (CV) of VAT/(VAT+SAT) was 5.2%. The interoperator CV was 1.1% and 5.3% for SAT and VAT estimates, respectively. The CV of IMCL was 13.7% in soleus, 11.9% in tibialis anterior and 2.9% with MRSI. IMCL based on MRSI (3.8+/-1.2%) were significantly inversely correlated with glucose disposal rate, as measured by a hyperinsulinemic-euglycemic clamp. VAT volume correlated significantly with IMCL. IMCL based on MRSI for IR subjects was significantly greater than that for IS subjects (4.5+/-0.9% vs. 2.8+/-0.5%, P=.02). CONCLUSION: MRI and MRS techniques provide a robust noninvasive measurement of abdominal fat and muscle IMCL, which are correlated with insulin action in humans.  相似文献   

7.

Background and Purpose

A recent report suggested that a serious burn injury was due to the presence of the identification (ID) wristband. As such, in lieu of removing or padding hospital ID wristbands in all patients prior to magnetic resonance imaging (MRI), testing may be performed to characterize risks for ID wristbands. Therefore, the purpose of this investigation was to evaluate the magnetic field interactions, heating and artifacts at 3 T for a hospital ID wristband.

Materials and Methods

Standardized test methods were used to evaluate magnetic field interactions, MRI-related heating, and artifacts at 3 T for a hospital ID wristband.

Results

There were no magnetic field interactions. MRI-related heating evaluated at a relatively high, MR system-reported, whole body-averaged specific absorption rate (2.9 W/kg) did not increase above the background level. The artifacts related to the ink used for printing were “small” for one toner and “large” for the other in relation to the dimensions of the printing.

Conclusions

Based on the tests performed, this particular hospital ID wristband is considered MR safe and will not pose a hazard to a patient undergoing an MRI examination. Importantly, it is not necessary to remove this item for a patient referred for MRI.  相似文献   

8.
Li Z  Li W  Li X  Pei F  Li Y  Lei H 《Magnetic resonance imaging》2007,25(3):412-417
The two gadolinium (Gd) polyoxometalates, K(15)[Gd(BW(11)O(39))(2)] [Gd(BW(11))(2)] and K(17)[Gd(CuW(11)O(39))(2)] [Gd(CuW(11))(2)] have been evaluated by in vivo and in vitro experiments as the candidates of potential tissue-specific magnetic resonance imaging (MRI) contrast agents. T(1) relaxivities of 17.12 mM(-1) x s(-1) for Gd(BW(11))(2) and 19.95 mM(-1) x s(-1) for Gd(CuW(11))(2) (400 MHz, 25 degrees C) were much higher than that of the commercial MRI contrast agent (GdDTPA). Their relaxivities in bovine serum albumin and human serum transferrin solutions were also reported. After administration of Gd(BW(11))(2) and Gd(CuW(11))(2) to Wistar rats, MRI showed longer and remarkable enhancement in rat liver and favorable renal excretion capability. The signal intensity increased by 37.63+/-3.45% for the liver during the whole imaging period (100 min) and by 61.47+/-10.03% for kidney within 5-40 min after injection at 40+/-1-micromol x kg(-1) dose for Gd(CuW(11))(2), and Gd(BW(11))(2) induced 50.44+/-3.51% enhancement in the liver in 5-50-min range and 61.47+/-10.03% enhancement for kidney within 5-40 min after injection at 39+/-4 micromol x kg(-1) dose. In vitro and in vivo study showed that Gd(BW(11))(2) and Gd(CuW(11))(2) are favorable candidates as tissue-specific contrast agents for MRI.  相似文献   

9.
We carried out retrospective analysis of apparent diffusion coefficient (ADC) values in 48 infiltrating ductal breast cancer patients who had dynamic contrast-enhanced magnetic resonance imaging (DCEMRI; Group I) and in 53 patients (Group II) for whom DCEMRI data were not available. Twenty-three patients of Group I showed no necrosis (Group Ia), while in 25 patients, both viable (nonnecrotic) and necrotic tumor areas (Group Ib) were observed on DCEMRI. T1-weighted, fat-suppressed and short inversion recovery images were used to identify the viable and necrotic tumor areas in Group II patients, and necrosis was not seen in 11 patients (Group IIa), while 42 (Group IIb) showed both viable and necrotic tumor areas. The ADCs of the necrotic area of Group Ib (1.79±0.30 ×10(-3) mm(2)/s) and Group IIb (1.83±0.40 ×10(-3) mm(2)/s) patients were similar and significantly higher (P<.01) compared to the ADCs of the viable tumor area of Group Ia (0.96±0.21 ×10(-3) mm(2)/s) and Group IIa (0.90±0.17 ×10(-3) mm(2)/s) patients. Proton MR spectroscopy (MRS) data were also available in these patients, and the ADC values were retrospectively determined from the voxel from which MR spectrum was obtained. These values were compared with the ADC obtained for the viable and necrotic areas of the tumor. ADC of the MRS voxel was similar to that obtained for the viable tumor area in patients of both groups. This interesting observation reveals the potential utility of using ADC values to identify viable tumor area for positioning of voxel for MRS in the absence of DCEMRI data.  相似文献   

10.

Purpose

To investigate the relationship between estimated glomerular filtration rate (eGFR) and parameters calculated using intravoxel incoherent motion (IVIM) imaging of the kidneys.

Materials and Methods

We studied 365 patients, divided into 4 groups based on eGFR levels (mL/min/1.73 m2): group 1, eGFR ≥ 80(n = 80); group 2, eGFR 60–80 (n = 156); group 3, eGFR 30–60 (n = 114); and group 4 ,eGFR < 30 (n = 15). IVIM imaging was used to acquire diffusion-weighted images at 12 b values. The diffusion coefficient of pure molecular diffusion (D), the diffusion coefficient of microcirculation or perfusion (D*), and perfusion fraction (f) were compared among the groups using group 1 as control.

Results

In the renal cortex, D* values were significantly lower in groups 2, 3, and 4 than in group 1. The D value of renal cortex was significantly low in only group 3. In the renal medulla, the D* and D values were significantly lower only in groups 2 and 3, respectively.

Conclusion

As renal dysfunction progresses, renal perfusion might be reduced earlier and affected more than molecular diffusion in the renal cortex. These changes are effectively detected by IVIM MR imaging.  相似文献   

11.
To accelerate the analysis of a multi-element MRI coil, a two-way link is used between radiofrequency (RF) circuit and 3-D electromagnetic (EM) simulation tools. In this configuration, only one 3-D EM simulation is required to investigate the coil performance over a range of different tunings, saving considerable computation time. For the purpose of 3-D EM simulation, the coil feed networks and trim capacitors are substituted by 50 Ω ports. The entire coil was tuned in the RF circuit domain, and the near-field profiles of the electric and magnetic field components were then calculated, together with the specific energy absorption ratio (SAR) maps in the 3-D EM domain  相似文献   

12.
In this paper, a digital wireless transmission system based on 802.11b standard for magnetic resonance imaging (MRI) application is designed and built for the first time to eliminate the interference aroused by coil array cables. The analysis shows that the wireless receiver has a very high sensitivity to detect MRI signals. The modulation technique of differential quadrature phase shift keyed (DQPSK) can be applied to MRI data transmission with rate of 2 Mbps and bandwidth of 2 MHz. The bench test verifies that this wireless link has a dynamic range over 86 dB supporting up to 3 T MRI system data transmission. The 2D spin echo imaging of phantom is performed and the SNR of the image obtained by the wireless transmission can be comparable with that got by the coaxial cables.  相似文献   

13.
The objectives of this study were to assess the relationship between right and left hemidiaphragmatic motions during breathing in normal subjects and to investigate alterations in lung motion with changes in posture, using dynamic magnetic resonance (MR) imaging. Imaging was conducted with a 1.5-T MR scanner using fast imaging employing steady-state acquisition with a torso coil. Eight healthy subjects were instructed to breathe from end-inspiration to end-expiration as slowly and as deeply as possible. Imaging and breathing were started together to afford sequential images on the coronal plane. Imaging sequences were performed in supine, prone, left lateral decubitus and right lateral decubitus postures. The component of movement of the most cephalic point in the cephalocaudal axis was measured, and the diaphragmatic excursion (maximum hemidiaphragmatic displacement), synchrony and velocity of the right and left hemidiaphragmatic motions were calculated during the expiratory phase and the inspiratory phase, respectively. Excursion was greater in the right hemidiaphragm in most postures, except the left lateral decubitus. In supine and prone postures, both hemidiaphragms moved synchronously in both inspiratory and expiratory phases. In both lateral decubitus postures, the hemidiaphragms moved asynchronously with different velocities in the expiratory phase but with the same velocities in the inspiratory phase. The method described here allowed the assessment of diaphragmatic motions. Motions in the right and left hemidiaphragms changed with posture. In addition, diaphragmatic motion differed between expiratory and inspiratory phases. This study suggests the further potential of dynamic MR imaging for the evaluation of pulmonary functions or deficiencies.  相似文献   

14.

Purpose

To assess peripheral tissue perfusion disorder in streptozotocin (STZ)-induced diabetic rats by using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI).

Materials and Methods

A rat diabetes model was produced by intravenous injection of STZ. Diabetic rats were sustainably treated with either saline or insulin using an Alzet osmotic pump. Hind paw tissue perfusion was measured by signal intensity (SI) enhancement after gadolinium diethylenetriaminepentaacetic acid injection in DCE-MRI study and quantified using the initial area under the SI-time curve (IAUC). Peripheral tissue uptake of [14C]iodoantipyrine (IAP) was also determined as a marker of tissue blood flow for comparison with the IAUC value indicating tissue perfusion.

Results

STZ caused hyperglycemia at 1 and 2 weeks after injection. Treatment with insulin significantly alleviated hyperglycemia. At 2 weeks after STZ injection, peripheral tissue perfusion was clearly reduced in the diabetic rats and its reduction was significantly improved in the insulin-treated diabetic rats. Tissue perfusion evaluated by DCE-MRI was similar to the tissue blood flow measured by [14C]IAP uptake.

Conclusion

Our findings demonstrated that DCE-MRI can assess peripheral tissue perfusion disorder in diabetes. DCE-MRI could be suitable for noninvasive evaluation of peripheral tissue perfusion in both preclinical and clinical studies. It may also be useful for developing novel drugs to protect against diabetic vascular complications.  相似文献   

15.
We describe the design and operation of an open-access, very-low-field, magnetic resonance imaging (MRI) system for in vivo hyperpolarized 3He imaging of the human lungs. This system permits the study of lung function in both horizontal and upright postures, a capability with important implications in pulmonary physiology and clinical medicine, including asthma and obesity. The imager uses a bi-planar B0 coil design that produces an optimized 65 G (6.5 mT) magnetic field for 3He MRI at 210 kHz. Three sets of bi-planar coils produce the x, y, and z magnetic field gradients while providing a 79-cm inter-coil gap for the imaging subject. We use solenoidal Q-spoiled RF coils for operation at low frequencies, and are able to exploit insignificant sample loading to allow for pre-tuning/matching schemes and for accurate pre-calibration of flip angles. We obtain sufficient SNR to acquire 2D 3He images with up to 2.8 mm resolution, and present initial 2D and 3D 3He images of human lungs in both supine and upright orientations. 1H MRI can also be performed for diagnostic and calibration reasons.  相似文献   

16.
Magnetic resonance imaging (MRI) is an outstanding medical imaging modality but the quality often suffers from noise pollution during image acquisition and transmission. The purpose of this study is to enhance image quality using feature-preserving denoising method. In current literature, most existing MRI denoising methods did not simultaneously take the global image prior and local image features into account. The denoising method proposed in this paper is implemented based on an assumption of spatially varying Rician noise map. A two-step wavelet-domain estimation method is developed to extract the noise map. Following a Bayesian modeling approach, a generalized total variation-based MRI denoising model is proposed based on global hyper-Laplacian prior and Rician noise assumption. The proposed model has the properties of backward diffusion in local normal directions and forward diffusion in local tangent directions. To further improve the denoising performance, a local variance estimator-based method is introduced to calculate the spatially adaptive regularization parameters related to local image features and spatially varying noise map. The main benefit of the proposed method is that it takes full advantage of the global MR image prior and local image features. Numerous experiments have been conducted on both synthetic and real MR data sets to compare our proposed model with some state-of-the-art denoising methods. The experimental results have demonstrated the superior performance of our proposed model in terms of quantitative and qualitative image quality evaluations.  相似文献   

17.
This paper describes a study performed to evaluate the feasibility of using a 1.5-T whole-body magnetic resonance imaging (MRI) equipment, in combination with pharmacokinetic modeling, to obtain in vivo information about the morphology and perfusion of tarantulas (Eurypelma californicum). MRI was performed on three tarantulas using spin-echo sequences for morphological imaging and a rapid spoiled gradient-echo sequence for dynamic imaging during and after contrast medium (CM; Gd-DTPA) injection. Signal enhancement in dynamic measurements was evaluated with a pharmacokinetic two-compartment model. Spin-echo images showed morphological structures well. Dynamic images were of sufficient quality and allowed a model analysis of CM kinetics, which provides information about regional perfusion. In conclusion, morphological and dynamic contrast-enhanced MRI of tarantulas is feasible with a conventional clinical scanner. Studies of this kind are therefore possible without a dedicated high-field animal scanner.  相似文献   

18.

Objective

To evaluate the correlation between findings from diffusion weighted imaging (DWI) and microvascular density (MVD) measurements in VX2 liver tumors after transarterial embolization ablation (TEA).

Materials and Methods

Eighteen New Zealand white rabbits were used in this study. VX2 tumor cells were implanted in livers by percutaneous puncture under computed tomography (CT) guidance. Two weeks later, all rabbits underwent conventional magnetic resonance imaging (MRI) (T1 and T2 imaging), DWI, (b = 100, 600, and 1000 s/mm2) and TEA. MRI was performed again1 week after TEA. Liver tissue was then harvested and processed for hematoxylin and eosin (H&E) staining and immunohistochemical staining for CD31to determine MVD.

Results

VX2 liver tumors were successfully established in all 18 rabbits. Optimal contrast was achieved with a b value of 600 s/mm2.The maximum pre-operative apparent diffusion coefficient (ADC)difference value was 0.28 × 10− 3 ± 0.10 × 10− 3 mm2/s, and was significantly different (P < 0.001) from the maximum postoperative ADCdifference value of 0.47 × 10− 3 ± 0.10 × 10− 3 mm2/s. However, the mean ADC value for the entire tumor was not significantly correlated with MVD (r = 0.221, P = 0.379), nor was the ADC value for the regions of viable tumor (r = − 0.044, P = 0.862). However, the maximum postoperative ADCdifference value was positively correlated with MVD(r = 0.606, F = 12.247, P = 0.003).

Conclusion

DWI is effective to evaluate the therapeutic efficacy of TEA. The maximum ADCdifference offers a promising new method to noninvasively assess tumor angiogenesis.  相似文献   

19.
The misunderstanding of the labeling for an “MR conditional” respiratory ventilator system resulted in the placement of this device, which had substantial ferromagnetic components, too close to a 3-T magnetic resonance (MR) system, causing a projectile incident. Magnetic resonance imaging health care professionals should be aware of the potentially dangerous consequences when such medical devices that have Food and Drug Administration-approved MR conditional labeling are brought into the MR system room. Recommendations to prevent future incidents are provided herein.  相似文献   

20.
王璐璐  朱勇  钟凯 《波谱学杂志》2016,33(1):168-178
肥胖症已经成为严重威胁人类健康的主要慢性疾病之一,磁共振成像(MRI)和磁共振波谱(MRS)技术的结合运用,对于评价脂肪组织分布和蓄积程度具有极大的优势.该文总结了近年来MRI与MRS技术在肥胖症研究中的应用进展,并讨论了MRI与MRS技术在肥胖症临床应用及科学研究中的价值.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏