首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Since the CALUX (Chemically Activated LUciferase gene eXpression) bioassay is a fast and inexpensive tool for the throughput analysis of dioxin-like compounds in a large number of samples and requires only small sample volumes, the use of this technique in human biomonitoring programs provides a good alternative to GC-HRMS. In this study, a method for the separate analysis of PCDD/Fs and dioxin-like PCBs (dl-PCBs) in human serum with the new sensitive H1L7.5c1 mouse hepatoma cell line was optimized.Sample dilution factors of 5 and 2.4 were selected for routine analysis of respectively the PCDD/Fs and dl-PCBs. The validation studies showed that repeatability and within-lab reproducibility for the quality control (QC) standard were within the in-house criteria. A long-term within-lab reproducibility of 25% for the PCDD/F fraction and 41% for the dl-PCB fraction for the analysis of pooled serum samples, expressed as pg BEQ/g fat, was determined. CALUX recoveries of the spiked procedural blanks were within the acceptable in-house limits of 80-120% for both fractions and the LOQ was 30.3 pg BEQ/g fat for the PCDD/Fs and 14.5 pg BEQ/g fat for the dl-PCBs. The GC-HRMS recovery of a C13-spiked pooled serum sample was between 60 and 90% for all PCDD/F congeners and between 67 and 82% for the non-ortho PCBs. An adequate separation between both fractions was found. The CALUX/GC-HRMS ratio for a pooled serum sample was respectively 2.0 and 1.4 for the PCDD/Fs and the dl-PCBs, indicating the presence of additional AhR active compounds. As expected, a correlation was found between human serum samples analyzed with both the new H1L7.5c1 cell line and the more established H1L6.1c3 cell line. The geometric mean CALUX-BEQ values, reported for the adolescents of the second Flemish Environment and Health Study (FLEHS II) recruited in 2009-2010, were 108 (95% CI: 101-114) pg CALUX-BEQ/g fat for the PCDD/Fs and 32.1 (30.1-34.2) pg CALUX-BEQ/g fat for the dioxin-like PCBs.  相似文献   

2.
Chemical Activated LUciferase gene eXpression [CALUX] is a reporter gene mammalian cell bioassay used for detection and semi-quantitative analyses of dioxin-like compounds. CALUX dose-response curves for 2,3,7,8-tetrachlorodibenzo-p-dioxin [TCDD] are typically smooth and sigmoidal when the dose is portrayed on a logarithmic scale. Non-linear regression models are used to calibrate the CALUX response versus TCDD standards and to convert the sample response into Bioanalytical EQuivalents (BEQs). Several complications may arise in terms of statistical inference, specifically and most important is the uncertainty assessment of the predicted BEQ. This paper presents the use of linear calibration functions based on Box-Cox transformations to overcome the issue of uncertainty assessment. Main issues being addressed are (i) confidence and prediction intervals for the CALUX response, (ii) confidence and prediction intervals for the predicted BEQ-value, and (iii) detection/estimation capabilities for the sigmoid and linearized models. Statistical comparisons between different calculation methods involving inverse prediction, effective concentration ratios (ECR20-50-80) and slope ratio were achieved with example datasets in order to provide guidance for optimizing BEQ determinations and expand assay performance with the recombinant mouse hepatoma CALUX cell line H1L6.1c3.  相似文献   

3.
1H NMR was used to study the motion of monomer units in a layer of poly(ethylene oxide) chains grafted on silica. First, the dependence of the relaxation times on the grafting ratios is discussed qualitatively from a phenomenological point of view. Next, the NMR line narrowing effect by high-speed rotation is observed in the same samples with different grafting ratios. The magic angle spinning technique permits determination of two correlation times for each grafting ratio: tau(c) characteristic of an environment with a fast motion and tau(l) characteristic of an environment with a slow motion. In addition, the dynamics of these grafted chains are investigated by deuterium NMR (2H NMR), which is sensitive to the anisotropy of molecular motion. The evolution has been studied for two extreme grafting ratios and each time as a function of temperature. The anisotropy is more marked at low temperatures and for a low grafting ratio. The results are consistent with the 1H NMR relaxation times measured as a function of temperature.  相似文献   

4.
Baston DS  Denison MS 《Talanta》2011,83(5):1289-1421
The chemically activated luciferase expression (CALUX) system is a mechanistically based recombinant luciferase reporter gene cell bioassay used in combination with chemical extraction and clean-up methods for the detection and relative quantitation of 2,3,7,8-tetrachlorodibenzo-p-dioxin and related dioxin-like halogenated aromatic hydrocarbons in a wide variety of sample matrices. While sample extracts containing complex mixtures of chemicals can produce a variety of distinct concentration-dependent luciferase induction responses in CALUX cells, these effects are produced through a common mechanism of action (i.e. the Ah receptor (AhR)) allowing normalization of results and sample potency determination. Here we describe the diversity in CALUX response to PCDD/Fs from sediment and soil extracts and not only report the occurrence of superinduction of the CALUX bioassay, but we describe a mechanistically based approach for normalization of superinduction data that results in a more accurate estimation of the relative potency of such sample extracts.  相似文献   

5.
Polyhalogenated aromatic hydrocarbons, such as polychlorinated dibenzo-p-dioxins are a large and diverse group of environmental pollutants. Their tendency to accumulate in the food chain and their toxicity make monitoring necessary. The reference analysis method is laborious and very expensive, therefore cheap and rapid bioassays have been developed. The chemical-activated luciferase bioassay (CALUX) bioassay uses a recombinant cell line, which responds to dioxins and dioxin-like molecules with Ah receptor (AhR)-dependent induction of firefly luciferase in a dose related response. The CALUX was tested for its use in the screening of feed. Aliquots of 20 g of enriched feed were extracted with a toluene:methanol mixture (20:4 v/v) and extracts were defatted on 33% H2SO4 silica columns and purified on carbon columns. Only the dioxin and furan fraction was analysed, the PCB fraction was discarded. The precision of the method is acceptable and in compliance with an R.S.D. <30% as suggested for cell-based bioassays in the Commission Directive 2002/70/EC of July 2002. The results evidence good agreement between TEQ-values obtained by either CALUX or GC–HRMS. The method is now routinely in use for a feed screening programme designed by the Federal Agency for the Safety of the Food chain. Approximately, 25 samples are analysed weekly. From the obtained results approximately 10% was confirmed by GC–HRMS. The false positive ratio is 1% and no false negatives were found, making the use of the CALUX technology advantageous.  相似文献   

6.
Specific immune detection of glycated hemoglobin is still a great challenge owing to the small epitopic difference between Hemoglobin (Hb) and HbA1c. We report a new electrochemical immunoassay format for point of care testing of HbA1c. A conducting self‐assembled monolayer of mercaptophenyl boronic acid (MPBA) was used as a capture layer for binding of glycated proteins and ferrocene tagged anti‐HbA1c antibody (FcAb) as a tracer molecule on a gold screen printed electrode. Validation of the new HbA1c assay was carried out using 6 clinical samples with known HPLC values and a correlation coefficient of 98 % was observed.  相似文献   

7.
Two new sesquiterpenes, epi‐guaidiol A (1) and sugebiol (3), together with four known sesquiterpenes, guaidiol A(2), sugetriol triacetate (4), cyperenoic acid (5), and cyperotundone (6) were isolated from the rhizomes of Cyperus rotundus L. Their structures were identified by MS and NMR experiments, and the complete assignments of 1H and 13C NMR data for two new sesquiterpenes were obtained by the aid of two‐dimensional (2D) NMR techniques, including HSQC, HMBC, 1H‐1HCOSY and nuclear overhauser enhancement spectroscopy(NOESY). Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
为了进一步研究3-取代苄基-6-三氟甲基嘧啶-2,4(1H,3H)-二酮衍生物的除草活性, 以期发现更高活性化合物, 合成了16个未见文献报道的3-取代苄基-6-三氟甲基嘧啶-2,4(1H,3H)-二酮衍生物, 其结构均经过1H NMR, IR和元素分析确证. 生测结果表明, 嘧啶环1-位取代基的变化, 不仅影响化合物的抑制活性与选择性, 可能还改变了化合物的作用方式. 定量的结构与活性关系研究表明, 当作用对象为油菜时, 化合物的活性可能主要与取代基R的摩尔分子折射常数有关; 当作用对象为稗草时, 化合物的活性可能主要与取代基R的电性参数有关. 1-位为氢时, 有利于对油菜生长的抑制; 1-位为甲基时, 有利于对稗草生长的抑制.  相似文献   

9.
Following the dioxin crisis of 1999, several studies were conducted to assess the impact of this crisis on the dioxin body burden in the Belgian population. The Scientific Institute of Public Health identified a population from whom plasma samples were available and from whom, during the follow up survey, plasma samples were obtained in 2000. In total, 496 samples were collected for GC-HRMS and CALUX analyses to verify statistical assessment conclusions. This study was seen as an opportunity to validate the CALUX bioassay for biological sample analysis and to compare toxic equivalency (TEQ) values obtained by the reference GC-HRMS technique and by the screening method. This article focuses on the validation results of the CALUX bioassay for the analyses of the dioxin fractions of blood plasma. The sample preparation is based on a liquid–liquid extraction, followed by an acid silica in series with an activated carbon clean-up. A good recovery (82%) and reproducibility (coefficient of variation less than 25%) were found for this method. Based on 341 plasma samples, a significant correlation was established between the bioassay and chemical method (R = 0.64). However, a proportional systematic error was observed when the results obtained with the CALUX bioassay were regressed with the results from the GC-HRMS analyses. The limit of quantification (LOQ) used to calculate TEQ values from the GC-HRMS determinations, the use of the relative potency values instead of the toxic equivalent factor and the potential of CALUX bioassay to measure all compounds with affinity for the AhR may partly explain this proportional systematic error. Nevertheless, the present results suggest that the CALUX bioassay could be a promising valid screening method for human blood plasma analyses.  相似文献   

10.
In the course of the basic hydrolysis of four eremophilane esters isolated from Robinsonecio gerberifolius, some rearrangements, eliminations, and additions occurred. Five compounds were obtained, three of them not previously described. Additionally, a new sesquiterpene was produced by autooxidation of compound 1. The (1)H and (13)C NMR spectra of these compounds were completely assigned by utilization of HMQC, HMBC, COSY, DEPT, and NOESY techniques. The long-range coupling constants of the peroxide 10 are reported, and all its coupling constants (2)J(H, H), (3)J(H, H), and (4)J(H, H) are calculated at the B3LYP/6-31G(d,p) level of theory. Their magnitude is explained in terms of electronic delocalization and the additivity of stereoelectronic effects.  相似文献   

11.
Expression of exogenous DNA in vitro is significantly affected by the particular transfection method utilized. In this study, we evaluated the efficiency of two transfection methods, chemically mediated polyethyleneimine (PEI) treatment and physically mediated electroporation, on a rat heart myoblast cell line, H9c2(2-1). After PEI transfection of pPgk-1/EGFP into H9c2(2-1) cells, EGFP expression could be easily detected by fluorospectrometer after 48 h (210 ± 12 RFU) and continued to increase after 72 h (243 ± 14 RFU). However, when H9c2(2-1) cells were transfected by electroporation (200 V, 500 μF, and one pulse), low level EGFP expression was observed after 48 h (49 ± 4 RFU) or 72 h (21 ± 14 RFU). In contrast, the easily transfectable control CHO-K1 cell line displayed a stronger EGFP expression than the H9c2(2-1) cells either by PEI or electroporation transfection. When transfection efficiencies were assayed by flow cytometry after 72 h, 13.6 ± 2.2% of PEI and 10.1 ± 1.5% of electroporation (250 V, 500 μF, and two pulses) transfected cells of H9c2(2-1) expressed EGFP, and PEI-transfected cells appeared to be less damaged (viability 93.6%) as compared to electroporation-transfected cells (39.5%). However, both PEI and electroporation (580 V, 50 Ω, and 50 μF) were effective for transfection of CHO-K1 with a higher efficiency, cell viability, and EGFP expression than H9c2(2-1). Our results indicate that the transfection efficiency of different methods varies among cell lines and that PEI is more efficient than electropolation for transfection of H9c2(2-1) whereas both PEI and electroporation are suitable for CHO-K1 transfection.  相似文献   

12.
陆文超  李瑛琦  郭春  周凯 《合成化学》2004,12(4):397-398,404,J005
以苄胺为原料,经6步反应得到新型抗高血压药OPC-21268的中间体3,4-二氢-1-(4-哌啶基)-2(1H)-喹啉酮,总收率13.9%.  相似文献   

13.
1H and 13C NMR spectroscopic data for 4-aryl-3,4-dihydro-6-methyl-2(1H)pyridone derivatives were fully assigned by a combination of one- and two- dimensional experiments (DEPT, HMBC, HMQC, COSY, NOE).  相似文献   

14.
以培养的原发性肝细胞癌HepG2细胞和正常肝细胞L02为研究对象, 用细胞裂解液提取总蛋白, 然后采用Carlson还原性β-消除法释放O-糖链, 以阳离子交换柱结合C18柱纯化分离O-糖链, 用电喷雾电离质谱(ESI-MS)和串联质谱(MS/MS)对O-糖链进行序列鉴定, 以β-环糊精为内标对2种细胞系的O-糖链进行定量比较分析. 结果表明, 在肝癌细胞系HepG2中检测到10种O-糖链, 正常细胞系L02中检测到9种O-糖链, 其中9种O-糖链是2种细胞系中共有的, 但HepG2中存在癌细胞中特有的缩短的O-糖链N1A1(NeuAc-GalNAc, sialyl Tn 抗原). t检验结果表明, HepG2与L02相比, 在检测到的10种O-糖链中有5种的含量具有极显著性差异(P<0.01), 2种的含量具有显著性差异(P<0.05).  相似文献   

15.
An efficient, facile, simple, and green synthetic protocol for the Biginelli reaction has been developed for the preparation of 3,4-dihydropyrimidin-2(1H)-thione derivatives under thermal and microwave irradiation, solvent-free conditions, in the presence of aluminum hydrogen phosphate, Al(H2PO4)3, as an environmentally friendly heterogeneous recyclable catalyst, in high to excellent yields and short reaction time. In addition, the catalyst could be easily recovered from the reaction mixture by simple filtration and reused several times without any loss of activity.  相似文献   

16.
张敏  毛神杰  吕培  谢龙观  徐效华 《有机化学》2008,28(9):1590-1597
为了寻找新的高活性农药, 利用2-甲基苯甲腈与不同的醛反应, 再通过2,3-二氯-5,6-二氰基-1,4-苯醌(DDQ)脱氢或NaH和CH3I氮甲基化, 合成了3个系列共18个5-取代氨基-12-取代苯并[c]菲啶衍生物, 其中15个是未见文献报道的化合物. 它们的结构均经1H NMR, 13C NMR, IR和高分辨质谱表征; 用X射线衍射测定了化合物5-氨基-12-(4-二乙氨基苯基)-11,12-2H-苯并[c]菲啶盐酸盐(3c)的晶体结构. 初步的生物活性测试结果表明, 部分化合物具有一定的杀菌活性和促进黄瓜子叶生根活性.  相似文献   

17.
A selective Spectrophotometric method has been developed for the trace determination of copper after adsorption of its 1-phenyl-4,4,6-trimethyl(1H, 4H)-pyrimidine-2-thiol (PTPT) complex onto microcrystalline naphthalene. The complex is quantitatively adsorbed on naphthalene in the pH range 7.5–11.5, separated by filtration, dissolved in dimethylformamide (DMF) and determined spectrophotometrically at 400 nm. Beer's law is obeyed in the concentration range 2.5–37.5 g of copper in 10 ml of DMF. The molar absorptivity and Sandell's sensitivity are 1.30 × 1041 · mol–1 · cm–1 and 0.0048g cm–2, respectively. Ten replicate analyses of a solution containing 20.0 g of copper gave a mean absorbance of 0.410 with a relative standard deviation of 0.91 %. The interferences of various ions have been studied and the method has been validated by the determination of copper in various standard reference materials, beers, wines, human hair, goat liver and environmental samples.On leave from St. Stephen's College, Delhi 110 007, India  相似文献   

18.
A simple, sensitive and reproducible high‐performance liquid chromatography (HPLC) assay method was developed for the estimation of 3‐pentylbenzo[c]thiophen‐1(3H)‐one (S5), a potential anti‐ischemic stroke agent, in dog plasma. The analytical procedure involves protein precipitation of S5 and nobiletin (internal standard) from dog plasma with acetonitrile. Chromatographic separation was achieved on Sapphire C18 analytical column with methanol–water (80:20, v/v) as mobile phase. The eluate was monitored using a UV detector set at 260 nm. The calibration curves were linear over the range of 0.2–20 µg/mL. Absolute recoveries of S5 were 79.2–86.1% from dog plasma. The intra‐ and inter‐day relative standard deviation precisions were <7 and 5%, respectively. The method was successfully applied to the pharmacokinetic study of S5 in beagle dogs. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

19.
A new surfactin isomer (1) was isolated from a mangrove bacteria strain 'Bacillus sp'. Its structure was identified, and full assignments of (1)H and (13)C NMR spectral data were achieved for the first time by a combination of mass spectrometry and 1D and 2D NMR experiments including DEPT, (1)H-(1)H COSY, HSQC, HMBC, TOCSY, ROESY, and HSQC-TOCSY. The NMR spectral data of eight known analogs (2-9) are also reported.  相似文献   

20.
1H NMR spectroscopy was employed to study the modifications over time of the water‐soluble low molecular weight metabolites extracted from samples of salted and dried mullet (Mugil cephalus) roes (mullet bottarga) stored at different conditions. Samples of grated mullet bottarga were stored for 7 months at ?20 °C, at 3 °C, and at room temperature in the presence and in the absence of light and then timely extracted and analyzed by NMR. Principal component multivariate data analysis applied to the spectral data indicated that samples stored at ?20 °C maintained similar features over time whereas, along PC1, samples stored at room temperature in the presence and in the absence of light showed, over time, marked metabolite modifications. The comparative analysis of the integrated areas of the selected regions of the 1H NMR spectra indicated that the major compositional changes due to storage conditions were (i) the increase of the derivatives of the breakdown of phosphatidylcholine (choline, phosphorylcholine, and glycerol), (ii) the breakdown of nucleosides, (iii) the decrease of methionine, tryptophan, and tyrosine, and (iv) the cyclization of creatine. These changes were observed at different storage conditions, with more pronounced trends in the samples stored at room temperature. The role of metabolites in food aging is discussed. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号