1.
A kind of new multi-layer adsorbent including Tenax TA/multi-walled carbon nanotubes (MWCNTs)/Carboxen 564 was developed for collecting volatile organic compounds. The adsorption and desorption efficiencies of 11 kinds of adsorbents (including Activated charcoal, Tenax TA, Carboxen 564, Chromosorb 101, Chromosorb 102, Chromosorb 103, Chromosorb 105, Porapak Q, GDX 301, XAD-2, and MWCNTs) were compared. By combining the advantages of Tenax TA, MWCNTs, and Carboxen 564, new type of multi-layer adsorbents was developed. The adsorption and desorption efficiency, the sampling reproducibility, and the effect of water were improved using multi-layer adsorbents, Tenax TA/MWCNTs/Carboxen 564. New multi-layer adsorbents were successfully applied to the determination of volatile organic compounds (VOCs) in ambient air.  相似文献   

2.
A polymeric material commonly used as a superabsorbent in the sanitary industry is proposed for the first time for analytical purposes. Specifically, we have evaluated in this work the possibility of using this material in a programmed-temperature vaporizer (PTV) injector for the introduction of large volume samples. To that end, the viability of this superabsorbent polymer as a retaining material was first studied by testing the stability of its absorption capacity in the presence of various solvents and at various temperatures. Subsequently, its effectiveness in the isolation of menthol and its isomers from Mentha piperita essential oil as well as gamma-lactones from peach essential oil was assessed. For that purpose, optimization of different variables, namely PTV temperatures during sampling, purge times, and desorption temperatures, involved in the solvent elimination was performed. Additionally, the information obtained was compared with that acquired for the adsorbent material Tenax TA. The results shown in this work proved not only the viability of using this superabsorbent polymer in analytical procedures but also demonstrated its advantages over the adsorbent Tenax TA in attaining internal GC concentration of a sample by introducing large volumes via PTV.  相似文献   

3.
Due to the growing need to monitor aircraft cabin, cockpit and breathing-line air quality, functional assessment of sampling equipment for the specialised field conditions of flight need to be established for both in-flight and ground safety. In this article, we assess the reliability of Tenax TA thermal desorption tubes to perform under various relevant field sampling conditions, such as storage temperature, loading temperature, vibrational velocity, gravitational force (G Force) and altitude pressure with semi-real-time gas chromatograph-mass spectrometer (GC-MS) analysis on the field portable HAPSITE® ER (Hazardous Air Pollutants on Site Extended Range) instrument. First, we show that Tenax TA thermal desorption tubes can handle storage under extreme environmental conditions, 4–77°C, over numerous analytical test cycles. Next, we confirm that extreme loading temperature, both hot (77°C) and cold (4°C), does not affect the analytical reliability of Tenax TA thermal desorption tubes. Then, we illustrate that G Force may have a significant (p ≤ 0.0364) effect on Tenax TA performance while vibrational velocity (p ≤ 0.7265) and low ambient air pressure (p ≤ 0.1753), such as that found at high altitude, do not. Finally, several Tenax TA thermal desorption tubes were flight-tested, demonstrating that the durability of these tubes maybe insufficient for use on military cargo aircraft (p = 0.0107). The results presented here provide a rationale for additional testing of Tenax TA thermal desorption tubes for flight suitability.  相似文献   

4.
A fast and accurate analytical method, which uses commercially available adsorbents (Tenax TA, Carbotrap B and C, and Carbosieve S-III), was developed for the sampling and determination of aromatic hydrocarbons, chloroaromatic compounds, and 2,3,7,8-tetrachlorodibenzo-p-dioxin. The breakthrough volume data show that Carbotrap C has a good capacity for compounds of high molecular weight, whereas Carbosieve S-III and Tenax TA are efficient for volatile compounds. The organic components are thermally desorbed and transferred to a gas chromatograph/mass spectrometer. Importantly, thermal desorption avoids conventional solvent extraction procedures and also allows reuse of adsorbent tubes. Preliminary results for recovery of analytes from tubes packed with single adsorbent prove that a single-adsorbent bed is not capable of sampling a wide range of compounds. The best method to obtain the desired collection and desorption properties is to use adsorbent tubes containing several different materials. The results of optimization studies are summarized.  相似文献   

5.
The storage stability of the occupationally frequently occurring compounds, methylethylketone, methylisobutylketone, benzene, toluene, tetrachloroethylene, n-butylacetate, -pinene, β-pinene, limonene and n-decane, has been investigated on the adsorbents Tenax TA, Chromosorb 106 and Carbotrap using thermally desorbable tube type samplers, commonly utilized in ambient and workroom atmospheric measurements. Fifty and 500 ng of each compound were loaded on the various adsorbents tubes, stored at both ambient (20 °C) and refrigerated (4 °C) temperatures and analysed by means of thermal gas chromatography with mass spectrometric detection on days 0, 7, 14 and 28 after exposure. A 90% storage recovery was chosen as acceptance criteria for storage stability, and statistical testing by Student's t-test, analysis of variance and Bonferroni post hoc tests were employed to investigate the effect of the categorical variables storage time, storage temperature and analyte loading on the different adsorbents. Chromosorb 106 showed the overall best behaviour with recoveries of 90% or better for all analytes during the 28-day test period. Tenax TA and Carbotrap yielded lower recoveries and were more influenced by variations in storage time, storage temperature and analyte loading. Refrigerated temperatures were best avoided for storage on Tenax TA, but may increase the recovery of some compounds on Carbotrap (e.g. n-butylacetate). The blank build-up on the adsorbents was also investigated, and Carbotrap and Tenax TA showed no signs of artefact development over time. Chromosorb 106, however, contained inherently more artefacts that build up over time, which in spite of the excellent storage capability, may limit its use in field studies where long storage times are normal.  相似文献   

6.
R. Leboda 《Chromatographia》1980,13(9):549-554
Summary The surface properties of complex adsorbents prepared through the pyrolysis of benzyl and n-heptyl alcohols and their mixtures on the surface of silica gel were investigated. The reactions were carried out in an autoclave at 500°C. A series of adsorbents having different porous structure, chemical nature of the adsorption centers and their topography were obtained. The best resolution of different mixtures was obtained by the carbon-silica adsorbent prepared through the pyrolysis of n-heptanol.  相似文献   

7.
An air sampling and analytical method based on adsorption on porous polymer (Tenax TA) followed by automatic thermal desorption (ATD) and GC/MS analysis was developed for ten pesticides commonly used on major crops in Britanny and some of their metabolites in air (from spray drift and volatilisation transfer processes): alachlor, atrazine (and two major degradation products: deethylatrazine and deisopropylatrazine), carbofuran, cyprodinil, epoxyconazole, iprodione (and 3,5-dichloroaniline), lindane (and -HCH, its isomer), metolachlor, terbuconazole and trifluralin. This method was established with special consideration for optimal thermal desorption conditions, linear ranges, limits of detection and quantification. Moreover, collection efficiencies of Tenax TA at room temperature were examined. This method was then applied to the determination of ambient pesticide levels during the spraying season at a rural area. The method was also applied to determine the vertical gradient of alachlor concentrations on a treated maize parcel to evaluate volatilisation fluxes.  相似文献   

8.
A comparison between two types of adsorbent tubes, the commonly used Tenax TA and a multi-sorbent bed (Carbotrap, Carbopack X, Carboxen 569) tube developed in our laboratory, has been done to evaluate their usefulness in the analysis of VOCs in ambient air. Duplicate indoor and outdoor samples of Tenax TA and multi-sorbent tubes of 10, 20, 40, 60 and 90 l were taken in Barcelona city (Spain) on July and October of 2009. Breakthrough values (defined as %VOCs found in the back tube) were determined for all sampling volumes connecting two sampling tubes in series. The analysis was performed by automatic thermal desorption (ATD) coupled with capillary gas chromatography (GC)/mass spectrometry detector (MSD). Significant differences between the concentrations obtained-from multi-sorbent bed and Tenax TA tubes are observed for the very volatile compounds (56 °C < boiling point < 100 °C and 4 kPa < vapour pressure (20 °C) < 47 kPa) (e.g. acetone, isopropanol, n-hexane) and for alcohols and chlorinated compounds (e.g. 1-butanol, carbon disulphide, dichloromethane, chloroform, carbon tetrachloride, trichloroethylene, tetrachloroethylene), being the concentrations found higher in multi-sorbent bed than in Tenax TA tubes. On the other hand, mainly all compounds with boiling points higher than 100 °C (except α-pinene, chlorinated and polar compounds) do not show significant differences between the obtained multi-sorbent bed and Tenax TA tube concentrations. For the concentrations obtained (5 ppt to 100 ppb), Tenax TA present high breakthrough values (from 0 to 77%) for mainly all compounds and sampling volumes studied. On the other hand, multi-sorbent bed tubes do not exhibit important breakthrough values for these compounds, except the VVOCs ethanol (for all sampled volumes), and acetone, dichloromethane and isopropanol (for sampling volumes over 40 l). The concentration differences observed between Tenax TA and multi-sorbent bed tubes are directly related to the high breakthrough values determined for Tenax TA adsorbent.  相似文献   

9.
A simple method using active trapping on adsorbents and thermal desorption followed by GC-MS analysis was developed for the indoor air monitoring of monoterpenes. The study was carried out using a dynamically generated atmosphere consisting of 11 monoterpenes: camphene, camphor, delta 3-carene, 1,8-cineol, limonene, linalool, alpha-pinene, beta-pinene, alpha-terpinene, gamma-terpinene, fenchyl alcohol. The influence of the different adsorbents Tenax TA, Tenax GR, Carbosieve SIII, Chromosorb 106 on the yield of six selected monoterpenes at indoor air concentrations was studied. The adsorbent Tenax GR gave relatively the best yields followed by Tenax TA. Detection limits of approximately 1 microgram m3 were determined with Tenax GR for most of the monoterpenes.  相似文献   

10.
Novel adsorbent APSG-MW (average particle size 215?µm and specific surface 98 m2?g?1) bonding multi-walled carbon nanotubes (MWCNTs) on silica gel are obtained. Then the sampling tubes filled with Tenax TA and APSG-MW are prepared and the adsorptive capacity of Tenax TA/APSG-MW for volatile organic sulfur compounds (VOSCs) is studied. The data show that the adsorption and desorption recoveries of multi-sorbent for VOSCs are satisfactory (>85%), and the breakthrough values are large (>16?L?g?1) enough to absorb VOSCs in ambient air. The sampling precision of the sorbent tubes meets TO-17 criteria. The sampling tubes are successfully used to concentrate and analyze a sample of landfill air, and the major S compounds are identified.  相似文献   

11.
Organic–inorganic poly(phthalazinone ether ketone) (PPEK)/SiO2 hybrid composite thin films were prepared by the dip-coating method on pre-cleaned glass substrates. The covalent bonds between organic and inorganic phases were introduced by an in-situ O-acylation reaction of isocyanatopropyltriethoxysilane (ICPTES) with the borohydride-reduced PPEK forming a polymer bearing triethoxysilyl groups. Theses groups were subsequently hydrolyzed with tetraethoxysilane (TEOS) and allowed to form a network via a sol–gel process. The polymer hybrid composite exhibited good thermal stability and a higher glass transition temperature as compared with the pure resin. Atomic force microscope, water contact angle measurement and scanning electron microscope were used to characterize the polymer hybrid thin films. The tribological experiment showed that the films have very low friction coefficient (about 0.1) and good anti-wear properties, without failure even after sliding for 18,000 s under modest loads. The improved tribological properties of the modified substrate were attributed to good adherence of PPEK/SiO2 hybrid films on the substrate and synergy of both PPEK matrix and silica particles.  相似文献   

12.
A theory has been developed for the adsorption of polyelectrolytes on charged interfaces from an aqueous salt solution. This adsorption is determined by the electrical charge density of the polyelectrolyte, the adsorption energy, the salt concentration, the molecular weight, solubility, flexibility, and concentration of polymer. The theory relates these parameters to the properties of the adsorbed polymer layer, i.e., the amount of polymer adsorbed, the fraction of the adsorbent interface covered, the fraction of the segments actually adsorbed on the interface versus the fraction of the segments in the dangling loops, the final surface charge density, and the thickness of the adsorbed layer. As polyelectrolyte adsorption should resemble nonionic polymer adsorption at high ionic strength of the solution or low charge density on the polymer, this work is an extension of the nonionic polymer adsorption theory to polyelectrolyte adsorption. The following effects are taken into account: (a) the conformational change upon adsorption of a coil in solution into a sequence of adsorbed trains interconnected by loops dangling in solution; (b) the interactions of the adsorbed trains with the interface and with each other; (c) the interaction of the dangling loops with the solvent; (d) the change in surface charge density of the adsorbent due to adsorption of charged trains and the accompanying changes in the electrical double layer which contains “small” ions as well as charged loops; (e) the (induced) dipole interaction of the adsorbed trains with the charged adsorbent interface. The theory is worked out for low potentials (Debye—Hückel approximation); in Appendix B an outline of a more complete treatment is given. The predicted adsorption isotherms have the experimentally observed high-affinity character. A relation between the adsorption energy, the surface charge density on the adsorbent, the degree of dissociation of the polymer, and the salt concentration predicts the conditions under which no adsorption will occur. For adsorbent and polymer carrying the same type of charge (both positive or both negative) the adsorption is predicted to decrease with increased charge density on polymer or adsorbent and to increase with salt concentration. If adsorbent and polymer carry different type charges, the adsorption as a function of the degree of dissociation, α, goes through a maximum at a relatively low value of α and, depending on the adsorption energy, an increase in the salt concentration can then increase or decrease the adsorption. At finite polymer concentration in solution the number of adsorbed segments and the fraction of the interface covered practically do not change with an increase in polymer concentration, whereas the total number of polymer molecules adsorbed increases slightly, as does the average fraction of segments in loops. The experimental results for polyelectrolyte adsorption have been reviewed in general and, as far as data are available, the predictions of the theory seem to follow the experimentally observed trends quite closely, except for the thickness of the adsorbed layer. This thickness is systematically overestimated by the theory and two reasons for this are given. The theoretical model implies a not too low ionic strength of the solution. Extrapolation of results to solutions of very low ionic strength is not warranted.  相似文献   

13.
A new approach to the introduction of large aqueous samples into a gas chromatograph, solid phase extraction - thermal desorption, is presented. Carrier gas pushes the sample through a packed liner mounted in a programmed temperature vaporizer; analytes retained by the packing material are thermally desorbed after drying of the adsorbent. The sorption properties and thermal stability of some packing materials have been studied off-line. Tenax GC®, and octyl-modified silica silylated with diphenyltetramethyldisilazane to improve its thermal stability, appeared to be suitable materials. The drying period and the desorption temperature are critical for satisfactory performance of the method. When Tenax GC® is used as packing material, thermal desorption at 250°C for 15 min gives quantitative recovery for methyl esters up to hexacosanoic acid methyl ester. With the silylated octyl-modified silica, the application range is limited to the methyl esters of decanoic to octadecanoic acids.  相似文献   

14.
Sampling on Tenax TA of different mesh sizes followed by thermal desorption and gas chromatography was evaluated as a simple method for the determination of benzene, aniline, nitrobenzene and chlorobenzene in the workplace air. An alternative sampling technique in place of pump sampling was developed. Quantitative recoveries were obtained in the mass range 0.04–10 μg. It was found that air humidity had no effect on recovery. The charged tubes can be stored at room temperature for 5 days with no change in recovery. The particle size of Tenax TA has no significant effect on adsorption and desorption.  相似文献   

15.
用X-射线光电子能谱对3种植物基活性炭材料:椰壳活性炭 (CAC4)、剑麻茎基活性炭(SSAC)和剑麻基活性碳纤维 (SACF) 的表面化学结构进行了表征,并研究和对比了它们的吸附性能,包括对碘、苯酚和亚甲基蓝的液相吸附性能,对有机蒸汽的吸附性能以及对Au3+的还原吸附性能等。结果表明,3个样品表面均含有多种含氧官能团,吸附能力SACF>SSAC> CAC4。样品的吸附性能主要取决于自身孔结构,与其表面化学结构也有密切的关系。  相似文献   

16.
A series of Cr1?xAlxN (where x denotes the atom fraction of Al in Cr1?xAlxN film) films with different Al contents have been deposited by unbalanced reactive magnetron sputtering technique. The chemical composition, microstructure, surface morphology, cross‐sectional structure, mechanical properties, thermal stability and tribological properties of the deposited films were studied by means of different techniques. It is found that with the increase of Al doping, the Al atoms either substitute the Cr atoms or occupy the interstitial sites in the CrN crystal lattice firstly, and when the Al doping content exceeds the solid solubility, superfluous Al atoms then exist in the form of amorphous or nanocrystal state in the films. Meanwhile, the grain size becomes smaller, and the microstructure gets denser because the Al doping leads to multiple crystal orientations and inhibits the grain growth. The Al doping induced solid solution hardening and grain boundary effects contribute to the high hardness of CrAlN films, and the dense structure as well as interstitial solid solution of Al, which can block the diffusion channel, endows the CrAlN films good oxidation resistance. Besides, a small amount of free Al existing in the films is favorable to improve the thermal stability without obvious loss of hardness. Finally, the relatively high hardness and good thermal stability make the Cr0.29Al0.71N film has relatively good tribological properties than CrN film under a wide temperature range, which extends the operating temperature of the CrN films in some fields. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

17.
The morphologies of PEDOTh films deposited on platinum electrodes, using different electrochemical modes but conditions selected to obtain layers with similar electroactivities, have been analysed by atomic force microscopy (AFM). Ex situ AFM showed a fibber-like topography for the potentiodynamically synthesised films, contrasting to the granular character of those formed at constant potential. In situ contact mode AFM, used to examine the initial stages of the polymer growth and the surface morphology evolution, disclosed the development of long segments with the number of potential cycles, and the formation of identical globular nodules, which diameter increases with the growth charge. The morphological changes imparted by the switching process revealed to be more marked in films grown at constant potential. Thickness measurements performed on oxidised and reduced films unveiled the swelling/shrinking of the polymers during the ingress/egress of the perchlorate anions, with film volume changes of ca. 20% upon oxidation.  相似文献   

18.
A combination of sorbent enrichment and ultrasound-assisted solvent extraction has been used to determine polychlorinated biphenyls in air. Analytes were sampled by pumping a known volume of air through a porous polymer (Tenax TA). The enriched adsorbent was transferred into a glass vial, and ultrasound-assisted extraction of the analytes was then performed in n-hexane. Quantification was carried out by using gas chromatography coupled to tandem mass spectrometry. Breakthrough volume of the sampling step was studied, indicating that 10 m3 of air could be processed without losses of the most volatile compounds. Good recoveries (75–96%) were obtained, and limits of detection at the sub ng m–3 were achieved for all the analytes. The proposed method is very simple and fast, avoiding the use of large solvent volumes and time-consuming preconcentration steps.  相似文献   

19.
Breakthrough volumes, average percentage recoveries, and storage stabilities were obtained for vapors of 8 volatile organic compounds (pentane, octane, undecane, isooctane, cyclohexane, toluene, methanol, and dichloromethane) on a new adsorbent material, Hypersol-Macronet, MN-200. Breakthrough volumes were estimated as half of the gas chromatographic specific retention volumes at 20 degrees C for the compounds. Recoveries of the adsorbates were determined by both solvent extraction and thermal desorption methods. The results obtained compare favorably with those for Tenax GR (values reported in the published literature and others obtained in our laboratory). Results of storage stability studies on MN-200 meet the criterion for acceptability (<10% loss). High adsorption capacity for very volatile and polar compounds, combined with ease of desorption of less volatile compounds, render MN-200 a highly promising adsorbent for sampling volatile organic compounds in indoor and outdoor air.  相似文献   

20.
Here we report on the fabrication and characterization of ultra-thin nanocomposite layers used as gate dielectric in low-voltage and high-performance flexible organic thin film transistors (oTFTs). Reactive sputtered zirconia layers were deposited with low thermal exposure of the substrate and the resulting porous oxide films with high leakage currents were spin-coated with an additional layer of poly-α-methylstyrene (PαMS). After this treatment a strong improvement of the oTFT performance could be observed; leakage currents could be eliminated almost completely. In ellipsometric studies a higher refractive index of the ZrO2/PαMS layers compared to the “as sputtered” zirconia films could be detected without a significant enhancement of the film thickness. Atomic force microscopy (AFM) measurements of the surface topography clearly showed a surface smoothing after the PαMS coating. Further studies with X-ray photoelectron spectroscopy (XPS) and transmission electron microscopy (TEM) also indicated that the polymer definitely did not form an extra layer. The polymer chains rather (self-)assemble in the nano-scaled interspaces of the porous oxide film giving an oxide–polymer “nanocomposite” with a high oxide filling grade resulting in high dielectric constants larger than 15. The dielectric strength of more than 1 MV cm−1 is in good accordance with the polymer-filled interspaces.  相似文献   