首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Monolithically integrated, polymer (SU-8) microchips comprising an electrophoretic separation unit, a sheath flow interface and an ESI emitter were developed to improve the speed and throughput of proteomics analyses. Validation of the microchip method was performed based on peptide mass fingerprinting and single peptide sequencing of selected protein standards. Rapid, yet reliable identification of four biologically important proteins (cytochrome C, β-lactoglobulin, ovalbumin and BSA) confirmed the applicability of the SU-8 microchips to ambitious proteomic applications and allowed their use in the analysis of human muscle cell lysates. The characteristic tryptic peptides were easily separated with plate numbers approaching 10(6), and with peak widths at half height as low as 0.6 s. The on-chip sheath flow interface was also exploited to the introduction of an internal mass calibrant along with the sheath liquid which enabled accurate mass measurements by high-resolution Q-TOF MS. Additionally, peptide structural characterization and protein identification based on MS/MS fragmentation data of a single tryptic peptide was obtained using an ion trap instrument. Protein sequence coverages exceeding 50% were routinely obtained without any pretreatment of the proteolytic samples and a typical total analysis time from sampling to detection was well below ten minutes. In conclusion, monolithically integrated, dead-volume-free, SU-8 microchips proved to be a promising platform for fast and reliable analysis of complex proteomic samples. Good analytical performance of the microchips was shown by performing both peptide mass fingerprinting of complex cell lysates and protein identification based on single peptide sequencing.  相似文献   

2.
We present a detailed optimization and characterization of the analytical performance of SU-8-based emitters for electrospray ionization mass spectrometry (ESI/MS). The improved SU-8 fabrication process presented here enhances patterning accuracy and reduces the time and cost of fabrication. All emitters are freestanding and enable sample delivery by both pressure-driven and spontaneous flows. The optimized emitter design incorporates a sharp, double-cantilevered tip implemented to the outlet of an SU-8 microchannel and provides highly sensitive ESI/MS detection. Moreover, the optimized design allows the use of relatively large microchannel dimensions (up to 200 x 50 microm(2), w x h) without sacrificing the detection sensitivity. This is advantageous with a view of preventing emitter clogging and enabling reproducible analysis. The measured limits of detection for the optimized emitter design were 1 nM for verapamil and 4 nM for Glu-fibrinopeptide B with good quantitative linearities between 1 nM and 10 microM (R(2) = 0.9998) for verapamil and between 4 nM and 3 microM (R(2) = 0.9992) for Glu-fibrinopeptide B. The measured tip-to-tip repeatability for signal intensity was 14% relative standard deviation (RSD) (n = 3; 5 microM verapamil) and run-to-run repeatability 4-11% RSD (n = 4; 5 microM verapamil) for all individual emitters tested. In addition, long-term stability of < 2% RSD was maintained for timescales of 30 min even under free flow conditions. SU-8 polymer was also shown to be chemically stable against most of the tested electrospray solvents.  相似文献   

3.
A new SU-8 based microchip capillary electrophoresis (MCE) device has been developed for the first time with integrated electrochemical detection. Embedded electrophoretic microchannels have been fabricated with a multilayer technology based on bonding and releasing steps of stacked SU-8 films. This technology has allowed the monolithic integration in the device of the electrochemical detection system based on platinum electrodes. The fabrication of the chips presented in this work is totally compatible with reel-to-reel techniques, which guarantee a low cost and high reliability production. The influence of relevant experimental variables, such as the separation voltage and detection potential, has been studied on the SU-8 microchip with an attractive analytical performance. Thus, the effective electrical isolation of the end-channel amperometric detector has been also demonstrated. The good performance of the SU-8 device has been proven for separation and detection of the neurotransmitters, dopamine (DA) and epinephrine (EP). High efficiency (30,000-80,000 N/m), excellent precision, good detection limit (450 nM) and resolution (0.90-1.30) has been achieved on the SU-8 microchip. These SU-8 devices have shown a better performance than commercial Topas (thermoplastic olefin polymer of amorphous structure) microchips. The low cost and versatile SU-8 microchip with integrated platinum film electrochemical detector holds great promise for high-volume production of disposable microfluidic analytical devices.  相似文献   

4.
We present rapid (<5 min) and efficient intact protein analysis by mass spectrometry (MS) using fully microfabricated and monolithically integrated capillary electrophoresis–electrospray ionization (CE–ESI) microchips. The microchips are fabricated fully of commercial inorganic–organic hybrid material, Ormocomp, by UV-embossing and adhesive Ormocomp–Ormocomp bonding (CE microchannels). A sheath-flow ESI interface is monolithically integrated with the UV-embossed separation channels by cutting a rectangular emitter tip in the end with a dicing saw. As a result, electrospray was produced from the corner of chip with good reproducibility between parallel tips (stability within 3.8–9.2% RSD). Thanks to its inherent biocompatibility and stable (negative) surface charge, Ormocomp microchips enable efficient intact protein analysis with up to ∼104 theoretical separation plates per meter without any chemical or physical surface modification before analysis. The same microchip setup is also feasible for rapid peptide sequencing and mass fingerprinting and shows excellent migration time repeatability from run to run for both peptides (5.6–5.9% RSD, n = 4) and intact proteins (1.3–7.5% RSD, n = 3). Thus, the Ormocomp microchips provide a versatile new tool for MS-based proteomics. Particularly, the feasibility of the Ormocomp chips for rapid analysis of intact proteins with such a simple setup is a valuable increment to the current technology.  相似文献   

5.
The purpose of the study was to determine the advantages of different mass spectrometric instruments and commercially available metabolite identification programs for metabolite profiling. Metabolism of tramadol hydrochloride and the excretion of it and its metabolites into human urine were used as a test case because the metabolism of tramadol is extensive and well known. Accurate mass measurements were carried out with a quadrupole time-of-flight mass spectrometer (Q-TOF) equipped with a LockSpray dual-electrospray ionization source. A triple quadrupole mass spectrometer (QqQ) was applied for full scan, product ion scan, precursor ion scan and neutral loss scan measurements and an ion trap instrument for full scan and product ion measurements. The performance of two metabolite identification programs was tested. The results showed that metabolite programs are time-saving tools but not yet capable of fully automated metabolite profiling. Detection of non-expected metabolites, especially at low concentrations in a complex matrix, is still almost impossible. With low-resolution instruments urine samples proved to be challenging even in a search for expected metabolites. Many false-positive hits were obtained with the automated searching and manual evaluation of the resulting data was required. False positives were avoided by using the higher mass accuracy Q-TOF. Automated programs were useful for constructing product ion methods, but the time-consuming interpretation of mass spectra was done manually. High-quality MS/MS spectra acquired on the QqQ instrument were used for confirmation of the tramadol metabolites. Although the ion trap instrument is of undisputable benefit in MS(n), the low mass cutoff of the ion trap made the identification of tramadol metabolites difficult. Some previously unreported metabolites of tramadol were found in the tramadol urine sample, and their identification was based solely on LC/MS and LC/MS/MS measurements.  相似文献   

6.
Yang Y  Li C  Lee KH  Craighead HG 《Electrophoresis》2005,26(19):3622-3630
We report the integration of solid-phase extraction (SPE) with mass spectrometry (MS) through an on-chip electrospray tip for sample precleaning and preconcentration. An in situ polymerized alkylacrylate-based monolithic column was used as the stationary phase for the on-chip SPE. Each microchip consists of two sets of microchannels and their respective integrated electrospray tips, with a common gold electrode. After the microchip was fabricated from cycloolefin polymer by hot embossing, thermal bonding, and annealing steps, a mixture of monomers and porogenic solvents was pumped into the microchannels and certain areas of the main microchannels were exposed to UV irradiation through a mask. The resulting porous monolithic beds that were polymerized from different compositions of the mixture were characterized by scanning electron microscopy. The microchip containing the monolithic column was then interfaced to an ion trap (IT) mass spectrometer by modifying a commercially available interfacing system. Makeup solution from the side channel was infused concurrently with the solution flowing into the main channel, and the mixture of these two solutions was sprayed into the MS orifice. Both the adsorption and elution of a pharmaceutical test compound, imipramine, to and from the on-chip SPE columns were monitored by MS. The potential application of this device for sample cleanup was demonstrated by pretreatment of urine samples spiked with imipramine.  相似文献   

7.
Tramadol is a centrally acting analgesic drug that has been used clinically for the last two decades to treat pain in humans. The clinical response of tramadol is strictly correlated to its metabolism, because of the different analgesic activity of its metabolites. O‐Desmethyltramadol (M1), its major active metabolite, is 200 times more potent at the µ‐receptor than the parent drug. In recent years tramadol has been widely introduced in veterinary medicine but its use has been questioned in some species. The aim of the present study was to develop a new sensible method to detect the whole metabolic profile of the drug in horses, through plasma analyses by high‐performance liquid chromatography (HPLC) coupled with fluorimetric (FL) and photodiode array electrospray ionization mass spectrometric (PDA‐ESI‐MS) detection, after its sustained release by oral administration (5 mg/kg). In HPLC/FL experiments the comparison of the horse plasma chromatogram profile with that of a standard mixture suggested the identification of the major peaks as tramadol and its metabolites M1 and N,O‐desmethyltramadol (M5). LC/PDA‐ESI‐MS/MS analysis confirmed the results obtained by HPLC/FL and also provided the identification of two more metabolites, N‐desmethyltramadol (M2), and N,N‐didesmethyltramadol (M3). Another metabolite, M6, was also detected and identified. The present findings demonstrate the usefulness and the advantage of LC/ESI‐MS/MS techniques in a search for tramadol metabolites in horse plasma samples. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

8.
Liu C  Cui D  Cai H  Chen X  Geng Z 《Electrophoresis》2006,27(14):2917-2923
We present a novel concept of glass/poly(dimethylsiloxane) (PDMS)/glass sandwich microchip and developed a thin-casting method for fabrication. Unlike the previously reported casting method for fabricating PDMS microchip, several drops of PDMS prepolymer were first added on the silanizing SU-8 master, then another glass plate was placed over the prepolymer as a cover plate, and formed a glass plate/PDMS prepolymer/SU-8 master sandwich mode. In order to form a thin PDMS membrane, a weight was placed on the glass plate. After the whole sandwich mode was cured at 80 degrees C for 30 min, the SU-8 master was easily peeled and the master microstructures were completely transferred to the PDMS membrane which was tightly stuck to the glass plate. The microchip was subsequently assembled by reversible sealing with the glass cover plate. We found that this PDMS sandwich microchip using the thin-casting method could withstand internal pressures of >150 kPa, more than 5 times higher than that of the PDMS hybrid microchip with reversible sealing. In addition, it shows an excellent heat-dissipating property and provides a user-friendly rigid interface just like a glass microchip, which facilitates manipulation of the microchip and fix tubing. As an application, PDMS sandwich microchips were tested in the capillary electrophoresis separation of fluorescein isothiocyanate-labeled amino acids.  相似文献   

9.
A novel and simple method based on layer-by-layer (LBL) technique has been developed for the modification of the channel in PDMS electrophoresis microchip to create a hydrophilic surface with a stable EOF. The functional surface was obtained by sequentially immobilizing chitosan and deoxyribonucleic acid (DNA) onto the microfluidic channel surface using the LBL assembly technique. Compared to the native PDMS microchips, the contact angle of the chitosan-DNA modified PDMS microchips decreased and the EOF increased. Experimental conditions were optimized in detail. The chitosan-DNA modified PDMS microchips exhibited good reproducibility and long-term stability. Separation of uric acid (UA) and ascorbic acid (AA) performed on the modified PDMS microchip generated 43,450 and 46,790 N/m theoretical plates compared with 4048 and 19,847 N/m with the native PDMS microchip. In addition, this method has been successfully applied to real human urine samples, without SPE, with recoveries of 97-105% for UA and AA.  相似文献   

10.
This paper presents a simple fluid handling technique for microchip immunoassay. Necessary solutions were sequentially injected into a microchannel by air-evacuated poly(dimethylsiloxane), and were passively regulated by capillary force at the inlet opening. For heterogeneous immunoassay, microchips are potentially useful for reduction of sample consumption and assay time. However, most of the previously reported microchips have limitations in their use because of the needs for external power sources for fluid handling. In this paper, an on-chip heterogeneous immunofluorescence assay without such an external power source is demonstrated. The microchip consisting of poly(dimethylsiloxane) (PDMS) and glass has a simple structure, and therefore is suitable for single-use applications. Necessary solutions were sequentially injected into a microchannel in an autonomous fashion with the power-free pumping technique, which exploits the high solubility and the rapid diffusion of air in PDMS. For deionized water, this method yielded flow rates of 3-5 nL s-1 with reproducibility of 4-10%. The inlet opening of the microchannel functioned as a passive valve to hold the solution when the flow was finished. Rabbit immunoglobulin G (rIgG) and human C-reactive protein (CRP) were detected using the microchannel walls as reaction sites. With the sample consumption of 1 microL and the assay time of approximately 20 min including the antibody immobilization step, the sandwich immunoassay methods for rIgG and CRP exhibited the limits of detection of 0.21 nM (0.21 fmol) and 0.42 nM (0.42 fmol), respectively.  相似文献   

11.
付慧  胡小键  陈曦  林少彬 《色谱》2018,36(5):487-492
建立了高效、准确的同时测定人体尿样中多种多环芳烃代谢物的方法。取10.0 mL尿液,酶解,经固相萃取净化浓缩、0.2 μm滤膜过滤后,以Acquity UPLC®HSS T3(100 mm×2.1 mm,1.8 μm)为分析柱,甲醇和水为流动相,采用负离子电喷雾多反应监测模式检测样品中多环芳烃代谢物的含量。12种多环芳烃代谢物在0.04~20.0 μg/L范围内线性关系良好,相关系数>0.99,方法检出限为0.01~0.41 μg/L,平均回收率为80.0%~105%,批内RSD为1.21%~9.12%,批间RSD为4.43%~19.7%。应用该方法对淮河流域某区域的100份人体尿样进行了检测,多环芳烃代谢物的检出率为98%。该方法操作简单,灵敏度高,选择性好,可同时检测尿中12种羟基多环芳烃代谢物。  相似文献   

12.
一种可逆键合电泳微芯片的制作及在蛋白质分离中的应用   总被引:6,自引:0,他引:6  
阐述了一种可逆键合电泳微芯片的制作方法, 以及电泳微芯片在蛋白质分离、临床尿蛋白检测方面的应用. 用标准光刻腐蚀技术在石英基片上腐蚀泳道, 清洗腐蚀好的基片和盖片后, 在真空条件下实现键合. 此种方法键合制作的电泳微芯片可重复键合使用, 制得的电泳微芯片成功地用于标准蛋白质分离以及临床尿蛋白分析.  相似文献   

13.
A hydrophilic interaction liquid chromatographic–tandem mass spectrometric (HILIC–MS–MS) method for investigation of the in vivo metabolism of 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK), a potent carcinogen, in rabbit blood has been developed and validated. This method achieved excellent repeatability and accuracy. Recovery ranged from 76.9 to 116.3 % and precision (as RSD) between 0.53 and 6.52 %. Linearity was good for all compounds (R 2?>?0.9990) and the limit of detection (LOD) ranged from 0.016 to 0.082 ng mL?1. Pharmacokinetic analysis indicated that NNK was rapidly eliminated in vivo in rabbit blood and 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL) was the major metabolite. The hydroxy acid, keto acid, and NNAL-N-oxide were also important metabolites in rabbit blood. It is probable that α-methylene hydroxylation was the major pathway of α-hydroxylation of NNK and NNAL in the rabbit.
Figure
The process of the experiment in this study. NNK solution was injected into rabbit body. Blood samples were obtained and processed, and then transferred into vials. NNK and its metabolites were separated by HILIC column. The ion source of MS is ESI and MRM mode was employed for monitoring ion pairs. The chromatogram of NNK and its metabolites was obtained.  相似文献   

14.
Urinary biopterin (Bio) and neopterin (Neo) are important markers for clinical diagnosis of hyperphenylalaninemia. Herein, we developed a high‐throughput analysis method based on electrospray ionization mass spectrometry (ESI‐MS) with polymer tips for the rapid quantitative detection of Bio and Neo in clinical urine samples. Different polymer tips were investigated. It is found that the best detection sensitivity was achieved with hydrophobic polymer tip, ie, polyethylene tips. The high‐throughput polymer tip‐ESI‐MS method allowed a rapid analysis speed at ~40 seconds per sample. The limits of quantification (LOQ) (S/N ≥ 10) for the detection of Bio and Neo were improved to be 5.0 ng/mL. Acceptable relative standard deviation (RSD) values for Neo and Bio were measured to be 12.2% and 13.4% for direct measurement of Bio and Neo in raw urine samples, respectively. Furthermore, Bio and Neo were directly quantified from 18 clinical urine samples by presented method. The ratios of urinary Bio‐to‐Neo were analyzed for diagnosis of hyperphenylalaninemia. The results demonstrated that the present polymer tip‐ESI‐MS method is a promising strategy for the rapid analysis of clinical samples.  相似文献   

15.
In vivo metabolites of ketorolac (KTC) have been identified and characterized by using liquid chromatography positive ion electrospray ionization high resolution tandem mass spectrometry (LC/ESI‐HR‐MS/MS) in combination with online hydrogen/deuterium exchange (HDX) experiments. To identify in vivo metabolites, blood urine and feces samples were collected after oral administration of KTC to Sprague–Dawley rats. The samples were prepared using an optimized sample preparation approach involving protein precipitation and freeze liquid separation followed by solid‐phase extraction and then subjected to LC/HR‐MS/MS analysis. A total of 12 metabolites have been identified in urine samples including hydroxy and glucuronide metabolites, which are also observed in plasma samples. In feces, only O‐sulfate metabolite and unchanged KTC are observed. The structures of metabolites were elucidated using LC‐MS/MS and MSn experiments combined with accurate mass measurements. Online HDX experiments have been used to support the structural characterization of drug metabolites. The main phase I metabolites of KTC are hydroxylated and decarbonylated metabolites, which undergo subsequent phase II glucuronidation pathways. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

16.
This review highlights the methodological and instrumental developments in microchip micellar EKC (MCMEKC) from 1995. The combination of higher separation efficiencies in micellar EKC (MEKC) with high-speed separation in microchip electrophoresis (MCE) should provide high-throughput and high-performance analytical systems. The chip-based separation technique has received considerable attention due to its integration ability without any connector. This advantage allows the development of a multidimensional separation system. Several types of 2-D separation microchips are described in the review. Since complicated channel configurations can easily be fabricated on planar substrates, various sample manipulations can be carried out prior to MCMEKC separations. For example, mixing for on-chip reactions, on-line sample preconcentration, on-chip assay, etc., have been integrated on MEKC microchips. The application of on-line sample preconcentration to MCMEKC can provide not only sensitivity enhancement but also the elucidation of the preconcentration mechanism due to the visualization ability of MCE. The characteristics of these sample manipulations on MEKC microchips are presented in this review. The scope of applications in MCMEKC covers mainly biogenic compounds such as amino acids, peptides, proteins, biogenic amines, DNA, and oestrogens. This review provides a comprehensive table listing the applications in MCMEKC in relation to detection methods.  相似文献   

17.
Pressurized CEC (pCEC) coupled with ESI‐QTOF‐MS using a sheathless interface was applied for metabolomics to develop an alternative analytical method for metabolic profiling of complex biofluid samples such as urine. The hyphenated system was investigated with mixed standards and pooled urine samples to evaluate its precision, repeatability, linearity, sensitivity, and selectivity. The applied voltage, mobile phase, and gradient elution were optimized and applied for the analysis of urinary metabolites. Multivariate data analysis was subsequently performed and used to distinguish lung cancer patients from healthy controls successfully. High separation efficiency has been achieved in pCEC due to the EOF. For metabolite identification, the pCEC‐MS separation mechnism was helpful for discriminating the fragment ions of glutamine conjugates from co‐eluted metabolites. Three glutamine conjugates, including phenylacetylglutamine, acylglutamine C8:1, and acylglutamine C6:1 were identified among 16 differential urinary metabolites of lung cancer. Receiver‐operating‐characteristic analysis of acylglutamine C8:1 resulted in an area‐under‐curve value of 0.882. Overall, this work suggests that this pCEC‐ESI‐QTOF‐MS method may provide a novel and useful platform for metabolomic studies due to its superior separation and identification.  相似文献   

18.
A commercially available array of light emitting diodes (LEDs), namely a UV Shark series LED high flux array, was evaluated as a light source for photolithographic patterning of SU-8 photoresist for the fabrication of templates suitable to make poly(dimethylsiloxane) (PDMS) microchips for electrophoresis. At a distance of 15 cm from the substrate, a relatively even intensity of 0.76+/-0.05 mW/cm(2) was obtained over an area sufficient for patterning a 10 cm (4 in.) silicon wafer. The exposure source was evaluated using a spiral mask design covering a 10 cm wafer. PDMS replicates of this template made in a 25 microm thick layer of SU-8 3025 showed little variation in width over the surface of the substrate, with a variation of 3.2% RSD (n=36) and a maximum range in widths of 7.8% of the mean channel width. The use of the optional metal reflector available with the LED array provided partial collimation of the light allowing near vertical structures to be produced across the entire wafer, something which was not possible without the reflector. SU-8 masters prepared using the LED array were compared to masters made using an alternative cheap lithographic source, namely a gel crosslinker. The SU-8 features were much narrower with the LED array than the crosslinker due to the multiple light sources in the crosslinker. A PDMS microchip made using a SU-8 template created using the Shark UV LED array was used for the electrophoretic separation of three anionic fluorescent dyes, with efficiencies up to 32,000 plates. Given that the LED array can be purchased and assembled for less than US$ 500, the Shark UV LED array is a promising alternative to more expensive lithographic light sources and will have significant appeal to many researchers wishing to undertake research in microfluidics around the world.  相似文献   

19.
自制玻璃微流控芯片及其基本性能考察   总被引:3,自引:0,他引:3  
20世纪90年代初,自Manz等首次提出微全分析系统的概念以来,各种不同材料和功能的微流控芯片不断问世,其中应用得最多的是玻璃、石英及聚合物3种材料.玻璃和石英芯片因具有优异的电渗、光学和表面性质,其刻蚀加工技术和表面改性的化学方法均比较成熟,且传统毛细管电泳中各种成熟的分离方法可直接应用到玻璃芯片的制作中,因此在微全分析系统研究中具有十分重要的地位.  相似文献   

20.
Palmatine is an isoquinoline alkaloid that has been widely used in China for the treatment of various inflammatory diseases such as gynecological inflammation, bacillary dysentery, enteritis, respiratory tract infection, urinary infection, etc. In the study reported in this paper, a simple and rapid high-performance liquid chromatography/electrospray ionization (ESI) tandem mass spectrometric method (MS/MS) was developed for elucidation of the structures of metabolites of palmatine in rat urine after administration of a single dose (20 mg/kg). The rat urine samples were collected and purified through C18 solid-phase extraction cartridges, and then injected onto a reversed-phase C18 column with 60:40 (v/v) methanol/0.01% triethylamine solution (2 mM, adjusted to pH 3.5 with formic acid) as mobile phase and detected by on-line MS/MS. Identification of the metabolites and elucidation of their structures were performed by comparing changes in molecular masses (DeltaM), retention times and spectral patterns of product ions with those of the parent drug. As a result, six phase I metabolites, the parent drug palmatine and two phase II metabolites were identified in rat urine for the first time.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号