首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The carbonaceous fraction of airborne particulate matter (PM) is of increasing interest due to the adverse health effects they are linked to. Its analytical ascertainment on a molecular level is still challenging. Hence, analysis of carbonaceous fractions is often carried out by determining bulk parameters such as the overall content of organic compounds (OC) and elemental carbon (EC) as well as the total carbon content, TC (sum of OC and EC), however, no information about the individual substances or substance classes, of which the single fractions consist can be obtained. In this work, a carbon analyzer and a photo-ionization time-of-flight mass spectrometer (PI-TOF-MS) were hyphenated to investigate individual compounds especially from the OC fractions. The carbon analyzer enables the stepwise heating of particle samples and provides the bulk parameters. With the PI-TOF-MS, it is possible to detect the organic compounds released during the single-temperature steps due to soft ionization and fast detection of the molecular ions. The hyphenation was designed, built up, characterized by standard substances, and applied to several kinds of samples, such as ambient aerosol, gasoline, and diesel emission as well as wood combustion emission samples. The ambient filter sample showed a strong impact of wood combustion markers. This was revealed by comparison to the product pattern of the similar analysis of pure cellulose and lignin and the wood combustion PM. At higher temperatures (450 °C), a shift to smaller molecules occurred due to the thermal decomposition of larger structures of oligomeric or polymeric nature comparable to lignocelluloses and similar oxygenated humic-like substances. Finally, particulate matter from gasoline and diesel containing 10% biodiesel vehicle exhaust has been analyzed. Gasoline-derived PM exhibited large polycyclic aromatic hydrocarbons, whereas diesel PM showed a much higher total organic content. The detected pattern revealed a strong influence of the biodiesel content on the nature of the particulate organic material.  相似文献   

2.
谢园园  花磊  陈平  侯可勇  蒋吉春  王艳  李海洋 《色谱》2015,33(2):188-194
建立了一种气相色谱(GC)与单光子电离-飞行时间质谱(SPI-TOF MS)联用(GC/SPI-TOF MS)的分析方法。首先,设计了一种双层套管的传输管用于连接GC与SPI-TOF MS,实现了GC与单光子电离离子源的无缝连接。在此基础上,以n-十五烷标准品和苯/甲苯/二甲苯的标准气为对象,对电离源的重要电压参数进行了优化,得到了纯净的分子离子峰,实现了对各类有机物的快速和准确定性。最后,将该方法用于分析柴油中的挥发性与半挥发性有机物,获得了柴油组分的二维GC×SPI-TOF MS谱图。不需要复杂的谱图解析和数据处理,根据谱图中离子的质荷比(m/z)归纳了柴油的主要成分,包括脂肪烃、芳香烃和含量很低的苯并吡咯等含氮化合物;根据色谱的保留时间将柴油中的同分异构体区分开来。结果表明GC/SPI-TOF MS法是一种简单、有效的分析方法,非常适于柴油及复杂环境样品等的分析表征。  相似文献   

3.
A commercial thermogravimetry—supersonic jet-skimmer quadrupole mass spectrometer system (TG-Skimmer-QMS, Netzsch GmbH, Germany) was successfully converted for soft single photon ionisation time-of-flight mass spectrometric (SPI-TOFMS) detection of organic compounds. VUV light for SPI was generated by an electron beam pumped argon excimer light source (EBEL; E photon = 9.8 eV). Furthermore, the versatility of the system was conserved, as high temperature TG and DSC measurements as well as electron ionisation mass spectrometry for the detection of inorganic compounds are still possible. The new system was tested with two polymers and a hydrocarbon mixture (diesel). It was demonstrated that aliphatic and aromatic organic compounds can be detected without fragmentation. Thus the system allows the recording of a readily interpretable organic signature of, e.g. thermal polymer decomposition. The thermal degradation of polystyrene shows a rich signature of the monomer, some oligomers and minor products of irregular cleavings of carbon chains. Polycarbonate exhibits a thermal decomposition fingerprint which is dominated by products of bisphenol A. The bisphenol A monomer, however, is also detectable.  相似文献   

4.
For the real-time measurements of volatile organic compounds (VOCs) in vehicle exhaust, we employed a vacuum ultraviolet single-photon ionization time-of-flight mass spectrometer (VUV-SPI-TOFMS). Exhaust measurements from gasoline and diesel engine vehicles were performed using a chassis dynamometer. Hydrocarbons such as alkylbenzenes, alkenes, alkanes, and dienes were the major organic compounds present in both gasoline and diesel engine exhaust. The concentrations of organic compounds in gasoline exhaust were higher under running conditions than during idling. The VOC concentrations in diesel exhaust were higher during idling than during running conditions. The VUV-SPI-TOFMS measured composition and emission profiles of many hydrocarbons, including aliphatics and aromatics, in vehicle exhaust simultaneously with real time response.  相似文献   

5.
The electronic structure and one‐ and two‐photon absorption spectra of four fluorophores, p‐bis(o‐methoxystyryl)benzene (Bis‐MSB), coumarin 307, fluorescein and rhodamine B, commonly used as reference compounds for two‐photon absorption spectra, have been theoretically calculated and compared with available experimental data. The possible reasons for the wide discrepancies in two‐photon absorption cross‐sections reported in the literature are discussed on the basis of the theoretical findings. The role of a solvent environment on the electronic one‐ and two‐photon absorption spectra is also studied. We highlight some necessary precautions that one needs to take when comparing literature results of two‐photon absorption cross‐sections.  相似文献   

6.
We present a newly designed soft plasma ionization (SPI) source developed for mass spectrometric study of organic compounds in this study. The SPI cell having a relatively small size consists of a hollow anode and a hollow mesh cathode. The voltage–current characteristic depending on the pressure was investigated, indicating that it has similar characteristics to conventional hollow cathode glow discharges. To investigate the emission characteristics of the SPI source, some molecular band emission spectra (N2, N2+ and OH+) were measured by using argon and helium discharge gases. The SPI source was installed to a commercially used quadrupole mass analyzer for analyzing organic compounds. To demonstrate the SPI source, the mass spectra of some organic compounds (methylene chloride, toluene, benzene, cyclohexane and chloroform) were measured. The organic compounds were ionized with good stability in the plasma, and the fragmentation depended on the applied current. When helium and argon gases were used as the discharge gas, the helium plasma was more suitable for SPI-MS rather than argon because the argon plasma not only suffers from spectral interference but also has lower sensitivity.  相似文献   

7.
挥发性有机化合物(Volatile Organic Compounds,VOCs)是重要的大气污染物,严重地危害着人类健康.本文设计合成了一种末端携带反应活性硅氧烷基团的杯[4]芳烃衍生物,通过自组装和表面化学反应将其共价结合于玻璃基质表面,获得了一种杯[4]芳烃修饰玻璃基质.以此基质物理担载荧光活性物质--芘封端三聚噻吩(Py-3T),得到了一种对气相四氢呋喃具有"turn-on"及快速灵敏(26.7 μg/mL)响应特性的荧光传感薄膜.实验表明:除苯和甲苯之外,其它常见有机溶剂和化学物质蒸汽对该薄膜荧光发射基本没有影响.苯和甲苯也因响应程度小、响应速度慢而难以干扰测定过程.据此,可以预期该荧光薄膜有可能在THF气体传感上获得应用.  相似文献   

8.
A novel membrane inlet interface coupled to a single-photon ionization (SPI) miniature time-of-flight mass spectrometer has been developed for on-line rapid measurement of volatile organic compounds (VOCs). The vacuum ultraviolet (VUV) light source for SPI was a commercial krypton discharge lamp with photon energy of 10.6 eV and photon flux of 10(10) photons/s. The experimental results showed that the sensitivity was 5 times as high as obtained with the traditional membrane inlet. The enrichment efficiency could be adjusted in the range of 10 to 20 times for different VOCs when a buffer cell was added to the inlet interface, and the memory effect was effectively eliminated. A detection limit as low as 25 parts-per-billion by volume (ppbv) for benzene has been achieved, with a linear dynamic range of three orders of magnitude. The rise times were 6 s, 10 s and 15 s for benzene, toluene and p-xylene, respectively, and the fall time was only 6 s for all of these compounds. The analytical capacity of this system was demonstrated by the on-line analysis of VOCs in single puff mainstream cigarette smoke, in which more than 50 compounds were detected in 2 s.  相似文献   

9.
Two‐photon stimulated emission depletion (STED) cross sections were determined over a broad spectral range for a novel two‐photon absorbing organic molecule, representing the first such report. The synthesis, comprehensive linear photophysical, two‐photon absorption (2PA), and stimulated emission properties of a new fluorene‐based compound, (E)‐2‐{3‐[2‐(7‐(diphenylamino)‐9,9‐diethyl‐9H‐fluoren‐2‐yl)vinyl]‐5‐methyl‐4‐oxocyclohexa‐2,5‐dienylidene} malononitrile ( 1 ), are presented. Linear spectral parameters, including excitation anisotropy and fluorescence lifetimes, were obtained over a broad range of organic solvents at room temperature. The degenerate two‐photon absorption (2PA) spectrum of 1 was determined with a combination of the direct open‐aperture Z‐scan and relative two‐photon‐induced fluorescence methods using 1 kHz femtosecond excitation. The maximum value of the 2PA cross section ~1700 GM was observed in the main, long wavelength, one‐photon absorption band. One‐ and two‐photon stimulated emission spectra of 1 were obtained over a broad spectral range using a femtosecond pump–probe technique, resulting in relatively high two‐photon stimulated emission depletion cross sections (~1200 GM). A potential application of 1 in bioimaging was demonstrated through one‐ and two‐photon fluorescence microscopy images of HCT 116 cells incubated with micelle‐encapsulated dye.  相似文献   

10.
Groundwater can be contaminated when e.g. gasoline tanks leak. Due to sampling and lab analysis, groundwater monitoring is time consuming and expensive. The technologies developed for rapid on-site analysis of gasoline contaminated groundwater face the technical limitation to distinguish the gasoline from complex matrices. In the present study the fingerprint identification of volatile organic components (VOCs) in gasoline contaminated groundwater using gas chromatography (GC) differential ion mobility spectrometry (DMS) is investigated. Groundwater was spiked with five sorts of gasoline (one reformulated gasoline, gasoline without additives and three different brand gasoline collected on petrol stations) and analyzed by GC-DMS. Seven VOCs (benzene, toluene, ethyl benzene, m-xylene, p-xylene, o-xylene, 1,2,4-trimethylbenzene) were identified by GC mass spectrometry (GC-MS) as well as by GC-DMS and selected as markers. The semi-quantitative determination of the selected compounds was achieved. The limits of detection of the GC-DMS are 46.42?ng for benzene, 1.13?ng for toluene, 1.80?ng for ethylbenzene, 0.22?ng for m-xylene, 1.13?ng for p-xylene, 0.61?ng for o-xylene and 0.37?ng for 1,2,4-trimethylbenzene, respectively. These results reveal the feasibility of GC-DMS for on-site monitoring of contaminated groundwater.  相似文献   

11.
Ce(IV)-loaded Y-zeolites (CeY) were prepared for selective removal of the trace amount of organic sulfur compounds from hydrodesulfurization (HDS)-treated diesel oil. The CeY samples can be obtained from NH4-Y-zeolite (NH4Y) using liquid-phase ion-exchange and solid-state ion-exchange methods. The ion-exchange reactions, structures, and selective adsorptions of organic sulfur compounds of the CeY samples were investigated using XRD, IR, XPS, TEM, and GC sulfur analyzer. The organic sulfur compound uptakes strongly depend on the amount and the valency of Ce in the zeolite structure. Ce(IV) shows much higher adsorptive ability than Ce(III). A CeY-S sample prepared by solid-state ion-exchange reaction of NH4Y and Ce(NO3)3 with Ce/NH4 mole ratio of 0.63 at 250 degrees C showed a maximum sulfur uptake from a model solution of HDS-treated gasoline containing thiophene [S = 5 ppm (ppm = mg/L)]. A desulfurization from a HDS-treated diesel oil containing organic sulfur compounds (S = 1.87 ppm) and H2S (S = 0.73 ppm) was investigated with a combination of the CeY-S and a CuO adsorbent for removal of H2S by a batch method. The sulfur content was reduced to below 0.01 ppm for the first time. This method provides a promising desulfurization process to prepare a clean fuel for fuel cells.  相似文献   

12.
Usually, for the determination of trace concentration of lead in gasoline, a routine sample pre-treatment procedure (such as iodine monochloride method or boiled hydrochloric extraction method) is coupled with a spectrometric detector, because tetraethyl lead and tetramethyl lead were added in gasoline as a antiknock component. These methods involved, however, are often complex, time-consuming, labor-intensive and,hence, susceptible to errors and pollution. Use of microwave energy enhance extraction of organic compounds from solid matrices was reported, but, enhance extraction of organic compounds from organic matrices (in especial from the gasoline), then turning the extraction substance into an inorganic compound was not reported.  相似文献   

13.
For the comprehensive analysis of organic compounds, especially thermal labile and nonpolar compounds, an electrospray/vacuum ultraviolet (VUV) single-photon ionization (ES-SPI) method was developed. The fine droplets of the sample solution from the electrospray process were directed through a quartz capillary and two skimmers to form a molecular beam into a high vacuum ionization chamber. The neutral sample molecules were softly ionized with tunable VUV light and analyzed with a reflection time-of-flight mass spectrometer (RTOF-MS). The ionization energy (IE) and appearance onsets of fragments were obtained based on the photoionization efficiency (PIE) spectrum. The isomers can also be distinguished. With this new method, clean (fragment-free) mass spectra of nonpolar compounds, such as benzene, cyclohexane, and some thermal labile solid compounds (triphenylamine, thioacetamide, and urea) have been obtained without any tedious pretreatment. The components of complex mixtures (gasoline and kerosene) can be identified. Furthermore, quantitative analysis of the components can be obtained based on photoionization cross section data. This method may be used for quantitative analysis of small biomolecules and natural products.  相似文献   

14.
Soft laser photo-ionization mass spectrometry is presented as a separation dimension hyphenated with gas chromatographic techniques. Single photon ionization (SPI) is a universal soft ionization method which ionizes organic molecules with an ionization potential below 10.5 eV if 118 nm laser radiation is used. The inherently soft ionization of photo ionization techniques can further be utilized together with gas chromatography as a comprehensive two-dimensional separation method (GC x MS), using the GC retention time as first separation dimension and the molecular mass as second separation dimension. Some GC x MS chromatograms of diesel petroleum samples using SPI are presented and discussed. Finally, it is demonstrated that the coupling of soft SPI mass spectrometry with comprehensive two-dimensional gas chromatography (GC x GC) provides a three-dimensional separation technique (GC x GC x SPI-MS).  相似文献   

15.
Comprehensive two-dimensional gas chromatography (GC×GC) has been applied to the quantitative analysis of benzene, toluene, ethylbenzene, xylenes (BTEX), and all heavier aromatic compounds in gasoline. The two-dimensional chromatographic separation used volatility selection on the first-dimension column and polarity selection on the second-dimension column. In the resulting GC×GC chromatogram, aromatic species were resolved from other compound classes. Moreover, structurally related aromatics were grouped in a manner that facilitated identification and integration. The response of a flame ionization detector to each major aromatic group in gasoline was calibrated using internal standards. Quantitation produced results directly comparable with ASTM standard methods. The present GC×GC method can be expanded to analyze other gasoline components.  相似文献   

16.
Different Fourier transform infrared microspectroscopic techniques, using attenuated total reflection (ATR) mode and single-element mercury–cadmium–telluride (MCT) detector (mapping) or multielement MCT detector (raster scanning), are compared with each other for the characterisation of inorganic compounds and organic substances in paint cross sections. All measurements have been performed on paint cross sections embedded in potassium bromide, a transparent salt in the mid-infrared region, in order to better identify the organic materials without the interference of the usual embedding resin. The limitations and advantages of the different techniques are presented in terms of spatial resolution, data quality and chemical information achieved. For all techniques, the chemical information obtained is found to be nearly identical. However, ATR mapping performed with a recently developed instrumentation shows the best results in terms of spectral quality and spatial resolution. In fact, thin organic layers (∼10 μm) have been not only identified but also accurately located. This paper also highlights the recent introduction of multielement detectors, which may represent a good compromise between mapping and imaging systems.  相似文献   

17.
A high-speed determination of benzene in gasoline samples using a non-separative method based on direct injection into the mass spectrometer is proposed. The results obtained are very similar to those provided with fast GC-MS.The calibration set was made up of gasoline samples in which the benzene was determined chromatographically and samples of gasoline subjected to a process of evaporation - until the complete disappearance of the original benzene - to which known concentrations of this compound had been added. A PLS1 multivariate calibration model was constructed. Cross-validation was used to select the optimum number of PLS components. The prediction capacity of the model was checked with an additional group of gasoline samples that had not been used either in the construction or in the validation of the model.With the direct injection method proposed here it was possible to analyse 24 samples over a period of 1 h. The direct injection method is rapid, simple and - in view of the results - highly suitable for the determination of benzene in gasoline samples.  相似文献   

18.
A series of three-coordinate octupolar compounds with varied centers (boron, aluminum, and nitrogen), which exhibit very large effective two-photon absorption cross sections have been theoretically studied. The ground state geometries and electronic structures are obtained using the density functional theory with the B3LYP functional and 6-31G(d) basis set, and the results are comparable to the available experimental determinations. Based on the correct geometrical and electronic structures, the one- and two-photon absorptions are predicted by the ZINDO-SOS method. Among these compounds, the boron (B) and aluminum (Al) centers act as acceptors, while the nitrogen center acts as donor according to the net charge changes during the excitation. It is found that (i) the compounds with boron and aluminum centers show two large two-photon absorption peaks, while the molecule with nitrogen center show only one two-photon absorption peak; (ii) the cross sections of the molecules with B or Al as centers are larger than that of the molecule with nitrogen as center; furthermore, the two-photon absorption cross section of the molecule with Al center is larger than that of the molecule with B center, from this point of view, our theoretical prediction provides for the experiment a good new candidate with large two-photon absorption cross section for further research; (iii) lengthening the conjugation bridge by inserting a benzene ring on the organoborane compounds (forming the investigated molecule B-2) enhances the two-photon absorption cross section, and keeping good transparency at the same time.  相似文献   

19.
Zeolites NaY and LaNaY (ion-exchanged with aqueous lanthanum nitrate solution) were used as adsorbents for removing organic sulfur compounds from model gasoline solutions (without and with toluene) and fluid catalytic cracked gasoline in fixed-bed adsorption equipment at room temperature and atmosphere pressure. The adsorptive selectivity for organic sulfur compounds was significantly increased when Na(+) ions in zeolite NaY were exchanged with lanthanum ions. IR spectra of thiophene adsorption indicate that thiophene is adsorbed onto La(3+) ions via direct S-La(3+) interaction and Na(+) ions via pi-electronic interaction for La(3+)-exchanged zeolite NaY, but only via pi-electronic interaction with Na(+) ions for NaY. The amount of adsorbed thiophene on La(3+)-exchanged zeolite Y was slightly decreased by coadsorption of benzene, but greatly reduced on NaY. The adsorption of thiophene via interaction with La(3+) on La(3+)-exchanged zeolite Y is hardly replaced by benzene coadsorption. The direct S-La(3+) interaction might be the essential reason for the evidently improved adsorptive selectivity of LaNaY for removing organic sulfur compounds from solutions containing large amount of aromatics.  相似文献   

20.
Balabin RM  Lomakina EI 《The Analyst》2011,136(8):1703-1712
In this study, we make a general comparison of the accuracy and robustness of five multivariate calibration models: partial least squares (PLS) regression or projection to latent structures, polynomial partial least squares (Poly-PLS) regression, artificial neural networks (ANNs), and two novel techniques based on support vector machines (SVMs) for multivariate data analysis: support vector regression (SVR) and least-squares support vector machines (LS-SVMs). The comparison is based on fourteen (14) different datasets: seven sets of gasoline data (density, benzene content, and fractional composition/boiling points), two sets of ethanol gasoline fuel data (density and ethanol content), one set of diesel fuel data (total sulfur content), three sets of petroleum (crude oil) macromolecules data (weight percentages of asphaltenes, resins, and paraffins), and one set of petroleum resins data (resins content). Vibrational (near-infrared, NIR) spectroscopic data are used to predict the properties and quality coefficients of gasoline, biofuel/biodiesel, diesel fuel, and other samples of interest. The four systems presented here range greatly in composition, properties, strength of intermolecular interactions (e.g., van der Waals forces, H-bonds), colloid structure, and phase behavior. Due to the high diversity of chemical systems studied, general conclusions about SVM regression methods can be made. We try to answer the following question: to what extent can SVM-based techniques replace ANN-based approaches in real-world (industrial/scientific) applications? The results show that both SVR and LS-SVM methods are comparable to ANNs in accuracy. Due to the much higher robustness of the former, the SVM-based approaches are recommended for practical (industrial) application. This has been shown to be especially true for complicated, highly nonlinear objects.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号