首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
Novel analytical methods based on real-time quantitative polymerase chain reactions by use of new reference molecules were validated in interlaboratory studies for the quantitation of genetically modified (GM) maize and soy. More than 13 laboratories from Japan, Korea, and the United States participated in the studies. The interlaboratory studies included 2 separate stages: (1) measurement tests of coefficient values, the ratio of recombinant DNA (r-DNA) sequence, and endogenous DNA sequence in the seeds of GM maize and GM soy; and (2) blind tests with 6 pairs of maize and soy samples, including different levels of GM maize or GM soy. Test results showed that the methods are applicable to the specific quantitation of the 5 lines of GM maize and one line of GM soy. After statistical treatment to remove outliers, the repeatability and reproducibility of these methods at a level of 5.0% were <13.7 and 15.9%, respectively. The quantitation limits of the methods were 0.50% for Bt11, T25, and MON810, and 0.10% for GA21, Event176, and Roundup Ready soy. The results of blind tests showed that the numerical information obtained from these methods will contribute to practical analyses for labeling systems of GM crops.  相似文献   

2.
Analytical real-time PCR technology is a powerful tool for implementation of the GMO labeling regulations enforced in the EU. The quality of analytical measurement data obtained by quantitative real-time PCR depends on the correct use of calibrator and reference materials (RMs). For GMO methods of analysis, the choice of appropriate RMs is currently under debate. So far, genomic DNA solutions from certified reference materials (CRMs) are most often used as calibrators for GMO quantification by means of real-time PCR. However, due to some intrinsic features of these CRMs, errors may be expected in the estimations of DNA sequence quantities. In this paper, two new real-time PCR methods are presented for Roundup Ready soybean, in which two types of plasmid DNA fragments are used as calibrators. Single-target plasmids (STPs) diluted in a background of genomic DNA were used in the first method. Multiple-target plasmids (MTPs) containing both sequences in one molecule were used as calibrators for the second method. Both methods simultaneously detect a promoter 35S sequence as GMO-specific target and a lectin gene sequence as endogenous reference target in a duplex PCR. For the estimation of relative GMO percentages both delta CT and standard curve approaches are tested. Delta CT methods are based on direct comparison of measured CT values of both the GMO-specific target and the endogenous target. Standard curve methods measure absolute amounts of target copies or haploid genome equivalents. A duplex delta CT method with STP calibrators performed at least as well as a similar method with genomic DNA calibrators from commercial CRMs. Besides this, high quality results were obtained with a standard curve method using MTP calibrators. This paper demonstrates that plasmid DNA molecules containing either one or multiple target sequences form perfect alternative calibrators for GMO quantification and are especially suitable for duplex PCR reactions.Electronic Supplementary Material Supplementary material is available for this article if you access the article at . A link in the frame on the left on that page takes you directly to the supplementary material.  相似文献   

3.
The Cooperation Centre for Scientific Research Relative to Tobacco (CORESTA; Paris, France) "Task Force Genetically Modified Tobacco-Detection Methods" investigated the performance of qualitative and quantitative methods based on the polymerase chain reaction (PCR) for the detection and quantitation of genetically modified (GM) tobacco. In the 4 successful rounds of proficiency testing, the cauliflower mosaic virus 35S RNA promoter (CaMV 35S) and the Agrobacterium tumefaciens nopaline synthase terminator (NOS) were selected as target sequences. Blind-coded reference materials containing from 0.1 to 5.0% and from 0.15 to 4% GM tobacco were used in 2 rounds of qualitative and quantitative PCR, respectively. Eighteen laboratories from 10 countries participated in this study. Considering all methods and 2 rounds, the different laboratories were able to detect GM tobacco at the 0.1% level in 46 out of 58 tests in qualitative assays. The results of the proficiency test indicate that both end point screening and real-time quantitative methods are suitable for the detection of genetically modified organisms in tobacco leaf samples having a GM content of 0.1% or higher. The CORESTA proficiency study represents a first step towards the interlaboratory evaluation of accuracy and precision of PCR-based GM tobacco detection, which may lead to the harmonization of analytical procedures and to the enhancement of comparability of testing results produced by different laboratories.  相似文献   

4.
DNA analysis with the polymerase chain reaction (PCR) has become a routine part of medical diagnostics, environmental inspections, food evaluations, and biological studies. Furthermore, the development of a microscale PCR chip is an essential component of studies aimed at integrating PCR into a micro total analysis system (μ-TAS). However, the occurrence of air bubbles in microchannels complicates this process. In this study, we investigated a new technique based on the fluid dynamics of laminar flow that utilizes a small amount of mineral oil at the beginning of sample injection to prevent air bubbles from occurring in microchannels. We also further optimized the pressure, the length of the pressurizing channel and the volume of oil, thus making our microfluidic device more useful for high-temperature PCR. Additionally, quantitative continuous-flow PCR was performed using the optimized PCR chip in order to detect genetically modified (GM) maize. DNA was extracted from GM maize, MON 810, and non-GM maize at several concentrations from 0% (w/v) to 100% (w/v). The DNA amplification signals were then analyzed on the PCR chip using a laser-based system. The signal from our microfluidic PCR chip was found to increase in direct proportion to the initial GM maize concentration.  相似文献   

5.
In many countries, the labeling of grains, feed, and foodstuff is mandatory if the genetically modified (GM) organism content exceeds a certain level of approved GM varieties. We previously developed an individual kernel detection system consisting of grinding individual kernels, DNA extraction from the individually ground kernels, GM detection using multiplex real-time PCR, and GM event detection using multiplex qualitative PCR to analyze the precise commingling level and varieties of GM maize in real sample grains. We performed the interlaboratory study of the DNA extraction with multiple ground samples, multiplex real-time PCR detection, and multiplex qualitative PCR detection to evaluate its applicability, practicality, and ruggedness for the individual kernel detection system of GM maize. DNA extraction with multiple ground samples, multiplex real-time PCR, and multiplex qualitative PCR were evaluated by five laboratories in Japan, and all results from these laboratories were consistent with the expected results in terms of the commingling level and event analysis. Thus, the DNA extraction with multiple ground samples, multiplex real-time PCR, and multiplex qualitative PCR for the individual kernel detection system is applicable and practicable in a laboratory to regulate the commingling level of GM maize grain for GM samples, including stacked GM maize.  相似文献   

6.
Quantitative and qualitative methods based on PCR have been developed for genetically modified organisms (GMO). Interlaboratory studies were previously conducted for GMO quantitative methods; in this study, an interlaboratory study was conducted for a qualitative method for a GM soybean, Roundup Ready soy (RR soy), with primer pairs designed for the quantitative method of RR soy studied previously. Fourteen laboratories in Japan participated. Each participant extracted DNA from 1.0 g each of the soy samples containing 0, 0.05, and 0.10% of RR soy, and performed PCR with primer pairs for an internal control gene (Le1) and RR soy followed by agarose gel electrophoresis. The PCR product amplified in this PCR system for Le1 was detected from all samples. The sensitivity, specificity, and false-negative and false-positive rates of the method were obtained from the results of RR soy detection. False-negative rates at the level of 0.05 and 0.10% of the RR soy samples were 6.0 and 2.3%, respectively, revealing that the LOD of the method was somewhat below 0.10%. The current study demonstrated that the qualitative method would be practical for monitoring the labeling system of GM soy in kernel lots.  相似文献   

7.
In routine analysis, screening methods based on real-time PCR are most commonly used for the detection of genetically modified (GM) plant material in food and feed. In this paper, it is shown that the combination of five DNA target sequences can be used as a universal screening approach for at least 81 GM plant events authorised or unauthorised for placing on the market and described in publicly available databases. Except for maize event LY038, soybean events DP-305423 and BPS-CV127-9 and cotton event 281-24-236 × 3006-210-23, at least one of the five genetic elements has been inserted in these GM plants and is targeted by this screening approach. For the detection of these sequences, fully validated real-time PCR methods have been selected. A screening table is presented that describes the presence or absence of the target sequences for most of the listed GM plants. These data have been verified either theoretically according to available databases or experimentally using available reference materials. The screening table will be updated regularly by a network of German enforcement laboratories.  相似文献   

8.
The qualitative event-specific polymerase chain reaction detection method of genetically modified (GM) RT73 rapeseed was developed based on the cloned 3' end flanking sequence of RT73 rapeseed integration. The specificity of the method for GM RT73 rapeseed was validated using several different GM rapeseed lines, GM maize lines, GM soybean line, non-GM rapeseed, and other non-GM crops. In this study, the developed method was validated through an interlaboratory study by 12 laboratories from 6 countries. The sensitivity of this method was evaluated using several mixed rapeseed meals with different GM RT73 rapeseed contents from 5.0 to 0.01% prepared by our laboratory. The evaluated results showed that all of the rapeseed endogenous reference high mobility group protein gene (HMG I/Y), figwort mosaic virus 35S (FMV 35S) promoter, and RT73 event-specific fragment could be detected from rapeseed samples at 0.1% (w/w) with a confidence level of more than 95%. All results from the 12 laboratories indicated that the developed method could be considered fit for the detection and identification of GM RT73 rapeseed.  相似文献   

9.
Quantitative analysis of genetically modified (GM) foods requires estimation of the amount of the transgenic event relative to an endogenous gene. Regulatory authorities in the European Union (EU) have defined the labelling threshold for GM food on the copy number ratio between the transgenic event and an endogenous gene. Real-time polymerase chain reaction (PCR) is currently being used for quantification of GM organisms (GMOs). Limitations in real-time PCR applications to detect very low number of DNA targets has led to new developments such as the digital PCR (dPCR) which allows accurate measurement of DNA copies without the need for a reference calibrator. In this paper, the amount of maize MON810 and hmg copies present in a DNA extract from seed powders certified for their mass content and for their copy number ratio was measured by dPCR. The ratio of these absolute copy numbers determined by dPCR was found to be identical to the ratios measured by real-time quantitative PCR (qPCR) using a plasmid DNA calibrator. These results indicate that both methods could be applied to determine the copy number ratio in MON810. The reported values were in agreement with estimations from a model elaborated to convert mass fractions into copy number fractions in MON810 varieties. This model was challenged on two MON810 varieties used for the production of MON810 certified reference materials (CRMs) which differ in the parental origin of the introduced GM trait. We conclude that dPCR has a high metrological quality and can be used for certifying GM CRMs in terms of DNA copy number ratio.  相似文献   

10.
In Europe, a growing interest for reliable techniques for the quantification of genetically modified component(s) of food matrixes is arising from the need to comply with the European legislative framework on novel food products. Real-time polymerase chain reaction (PCR) is currently the most powerful technique for the quantification of specific nucleic acid sequences. Several real-time PCR methodologies based on different molecular principles have been developed for this purpose. The most frequently used approach in the field of genetically modified organism (GMO) quantification in food or feed samples is based on the 5'-3'-exonuclease activity of Taq DNA polymerase on specific degradation probes (TaqMan principle). A novel approach was developed for the establishment of a TaqMan quantification system assessing GMO contents around the 1% threshold stipulated under European Union (EU) legislation for the labeling of food products. The Zea mays T25 elite event was chosen as a model for the development of the novel GMO quantification approach. The most innovative aspect of the system is represented by the use of sequences cloned in plasmids as reference standards. In the field of GMO quantification, plasmids are an easy to use, cheap, and reliable alternative to Certified Reference Materials (CRMs), which are only available for a few of the GMOs authorized in Europe, have a relatively high production cost, and require further processing to be suitable for analysis. Strengths and weaknesses of the use of novel plasmid-based standards are addressed in detail. In addition, the quantification system was designed to avoid the use of a reference gene (e.g., a single copy, species-specific gene) as normalizer, i.e., to perform a GMO quantification based on an absolute instead of a relative measurement. In fact, experimental evidences show that the use of reference genes adds variability to the measurement system because a second independent real-time PCR-based measurement must be performed. Moreover, for some reference genes no sufficient information on copy number in and among genomes of different lines is available, making adequate quantification difficult. Once developed, the method was subsequently validated according to IUPAC and ISO 5725 guidelines. Thirteen laboratories from 8 EU countries participated in the trial. Eleven laboratories provided results complying with the predefined study requirements. Repeatability (RSDr) values ranged from 8.7 to 15.9%, with a mean value of 12%. Reproducibility (RSDR) values ranged from 16.3 to 25.5%, with a mean value of 21%. Following Codex Alimentarius Committee guidelines, both the limits of detection and quantitation were determined to be <0.1%.  相似文献   

11.
This paper presents results of a collaborative trial study (IUPAC project No. 650/93/97) involving 29 laboratories in 13 countries applying a method for detecting genetically modified organisms (GMOs) in food. The method is based on using the polymerase chain reaction to determine the 35S promotor and the NOS terminator for detection of GMOs. reference materials were produced that were derived from genetically modified soy beans and maize. Correct identification of samples containing 2% GMOs is achievable for both soy beans and maize. For samples containing 0.5% genetically modified soy beans, analysis of the 35S promotor resulted also in a 100% correct classification. However, 3 false-negative results (out of 105 samples analyzed) were reported for analysis of the NOS terminator, which is due to the lower sensitivity of this method. Because of the bigger genomic DNA of maize, the probability of encountering false-negative results for samples containing 0.5% GMOs is greater for maize than for soy beans. For blank samples (0% GMO), only 2 false-positive results for soy beans and one for maize were reported. These results appeared as very weak signals and were most probably due to contamination of laboratory equipment.  相似文献   

12.
Qualitative and quantitative DNA-based methods were applied to detect genetically modified foods in samples from markets in the Kingdom of Saudi Arabia. Two hundred samples were collected from Al-Qassim, Riyadh, and Mahdina in 2009 and 2010. GMOScreen 35S and NOS test kits for the detection of genetically modified organism varieties in samples were used. The positive results obtained from GMOScreen 35S and NOS were identified using specific primer pairs. The results indicated that all rice samples gave negative results for the presence of 35S and NOS terminator. About 26 % of samples containing soybean were positive for 35S and NOS terminator and 44 % of samples containing maize were positive for the presence of 35S and/or NOS terminator. The results showed that 20.4 % of samples was positive for maize line Bt176, 8.8 % was positive for maize line Bt11, 8.8 % was positive for maize line T25, 5.9 % was positive for maize line MON 810, and 5.9 % was positive for StarLink maize. Twelve samples were shown to contain <3 % of genetically modified (GM) soy and 6 samples >10 % of GM soy. Four samples containing GM maize were shown to contain >5 % of GM maize MON 810. Four samples containing GM maize were shown to contain >1 % of StarLink maize. Establishing strong regulations and certified laboratories to monitor GM foods or crops in Saudi market is recommended.  相似文献   

13.
A plasmid was constructed for quantification of genetically modified (GM) cottonseed meal in the gene-specific level. The Cry1Ab/c gene was connected with the Sad1 gene by fusion PCR. The fusion gene was cloned into the pMD®19-T Simple Vector. The plasmid DNA was then digested with a restriction endonuclease SmaI to reduce the characteristic differences between the plasmid DNA and genomic DNA. For a rough quantitative analysis of GM cotton meal contents, a rapid method for measurement of the copy numbers of the transgenic Cry and cotton endogenous Sad1 gene using a real-time PCR system with the plasmid DNA as a calibrator was established. The inter-run and intra-run coefficients of variation were less than 1.48% and 2.36%, respectively. The limits of detection and quantitation of the Cry and Sad1 genes were 9 and 91 copies of pMDCS, respectively. These results prove that the standard plasmid represents a valuable alternative to genomic DNA as a certified reference material for the quantification of GM cotton and is a useful tool to establish a feasible identification management for GM cottonseed meal content in the feed industry.  相似文献   

14.
In 2003 the European Commission introduced a 0.9 % threshold for food and feed products containing genetically modified organism (GMO)-derived components. For commodities containing GMO contents higher than this threshold, labelling is mandatory. To provide a DNA-based rapid and simple detection method suitable for high-throughput screening of GMOs, several isothermal amplification approaches for the 35S promoter were tested: strand displacement amplification, nicking-enzyme amplification reaction, rolling circle amplification, loop-mediated isothermal amplification (LAMP) and helicase-dependent amplification (HDA). The assays developed were tested for specificity in order to distinguish between samples containing genetically modified (GM) maize and non-GM maize. For those assays capable of this discrimination, tests were performed to determine the lower limit of detection. A false-negative rate was determined to rule out whether GMO-positive samples were incorrectly classified as GMO-negative. A robustness test was performed to show reliable detection independent from the instrument used for amplification. The analysis of three GM maize lines showed that only LAMP and HDA were able to differentiate between the GMOs MON810, NK603, and Bt11 and non-GM maize. Furthermore, with the HDA assay it was possible to realize a detection limit as low as 0.5 %. A false-negative rate of only 5 % for 1 % GM maize for all three maize lines shows that HDA has the potential to be used as an alternative strategy for the detection of transgenic maize. All results obtained with the LAMP and HDA assays were compared with the results obtained with a previously reported real-time PCR assay for the 35S promoter in transgenic maize. This study presents two new screening assays for detection of the 35S promoter in transgenic maize by applying the isothermal amplification approaches HDA and LAMP.  相似文献   

15.
Recent years have seen an increased interest in DNA trace detection methods involved in many areas of bioanalytical research, such as quantitation of genetically modified (GM) ingredients in food products. There is little in the way of standardisation of data handling from these methods, and the data generated needs to be analysed appropriately if the results are to be interpreted correctly. This paper describes particular aspects of real-time PCR trace detection methods in order to increase the understanding of data generated using this bioanalytical technique. Using the specific example of GM soya detection and quantitation, it focuses on the production of calibration curves based on the mean and individual data values, the interpretation of correlation coefficients, regression techniques, and discusses suitable data analysis arising from simple and more complex experimental designs following transformation. By using the approaches outlined in this paper, more accurate analysis of data from real-time PCR and GM trace detection methods could be achieved.  相似文献   

16.
A real-time polymerase chain reaction (QPCR) assay was developed for quantitative detection of a genetically modified (GM) maize event TC-1507 and modification to conventional PCR for qualitative purposes. Sequences 5'-flanking TC-1507 full-length insert were characterized and showed multiple rearrangements involving insert and maize chloroplast fragments. The event specificity of the TC-1507 assays was based on the detection of transgene and plant rearranged sequences found to 5' flank the insertion site. They were fully specific and exhibited a limit of detection below 10 target copies, allowing consistent detection of 0.1% GM levels. The QPCR was highly linear and efficient and proved adequate for quantification of GM contents, aiming at the fulfillment of legal requirements established in the European Union (i.e., compulsory labeling of TC-1507 levels >0.9%). It satisfactorily determined TC-1507 contents on different matrixes and was successfully transferred a different laboratory.  相似文献   

17.
The reliable quantification of genetically modified organisms (GMOs) by real-time PCR requires, besides thoroughly validated quantitative detection methods, sustainable calibration systems. The latter establishes the anchor points for the measured value and the measurement unit, respectively. In this paper, the suitability of two types of DNA calibrants, i.e. plasmid DNA and genomic DNA extracted from plant leaves, for the certification of the GMO content in reference materials as copy number ratio between two targeted DNA sequences was investigated. The PCR efficiencies and coefficients of determination of the calibration curves as well as the measured copy number ratios for three powder certified reference materials (CRMs), namely ERM-BF415e (NK603 maize), ERM-BF425c (356043 soya), and ERM-BF427c (98140 maize), originally certified for their mass fraction of GMO, were compared for both types of calibrants. In all three systems investigated, the PCR efficiencies of plasmid DNA were slightly closer to the PCR efficiencies observed for the genomic DNA extracted from seed powders rather than those of the genomic DNA extracted from leaves. Although the mean DNA copy number ratios for each CRM overlapped within their uncertainties, the DNA copy number ratios were significantly different using the two types of calibrants. Based on these observations, both plasmid and leaf genomic DNA calibrants would be technically suitable as anchor points for the calibration of the real-time PCR methods applied in this study. However, the most suitable approach to establish a sustainable traceability chain is to fix a reference system based on plasmid DNA.  相似文献   

18.
Despite the controversies surrounding genetically modified organisms (GMOs), the production of GM crops is increasing, especially in developing countries. Thanks to new technologies involving genetic engineering and unprecedented access to genomic resources, the next decade will certainly see exponential growth in GMO production. Indeed, EU regulations based on the precautionary principle require any food containing more than 0.9% GM content to be labeled as such. The implementation of these regulations necessitates sampling protocols, the availability of certified reference materials and analytical methodologies that allow the accurate determination of the content of GMOs. In order to qualify for the validation process, a method should fulfil some criteria, defined as “acceptance criteria” by the European Network of GMO Laboratories (ENGL). Several methods have recently been developed for GMO detection and quantitation, mostly based on polymerase chain reaction (PCR) technology. PCR (including its different formats, e.g., double competitive PCR and real-time PCR) remains the technique of choice, thanks to its ability to detect even small amounts of transgenes in raw materials and processed foods. Other approaches relying on DNA detection are based on quartz crystal microbalance piezoelectric biosensors, dry reagent dipstick-type sensors and surface plasmon resonance sensors. The application of visible/near-infrared (vis/NIR) spectroscopy or mass spectrometry combined with chemometrics techniques has also been envisaged as a powerful GMO detection tool. Furthermore, in order to cope with the multiplicity of GMOs released onto the market, the new challenge is the development of routine detection systems for the simultaneous detection of numerous GMOs, including unknown GMOs.  相似文献   

19.
Detection of trace amounts of allergens is essential for correct labeling of food products by the food industry. PCR-based detection methods currently used for this purpose are targeting sequences of DNA present in the cell nucleus. In addition to nuclear DNA, a substantial amount of mitochondrial DNA (mtDNA) copies are present in the cytoplasm of eukaryotic cells. The nuclear DNA usually consists of a set of DNA molecules present in two copies per cell, whereas mitochondrial DNA is present in a few hundred copies per cell. Thus, an increase in sensitivity can be expected when mtDNA is used as the target. In this study, we present a reporter probe-based real-time PCR method amplifying the mitochondrial gene of the alpha chain of adenosine triphosphate synthetase from soy. Increase in sensitivity was examined by determining the minimal amount of soy DNA detectable by mtDNA and nuclear DNA (nDNA) amplification. Additionally, the LOD of soy in a food matrix was determined for mtDNA amplification and compared to the LOD determined by nDNA amplification. As food matrix, a model spice spiked with soy flour was used. Sensitivity of PCR-based soy detection can be increased by using mtDNA as the target.  相似文献   

20.
Zhu H  Jiang L  Tao S  Lin H  Wang J  Tan F  Zhao K  Wu X  Li P  Pan A  Jia J  Tang X 《Journal of AOAC International》2011,94(4):1227-1232
The validation of the anthocyanin synthase (ANS) gene as a carnation endogenous reference gene applicable both in classical and real-time PCR methods is a prerequisite for the development of PCR assays for genetically modified (GM) carnation detection. This is important due to the fact that GM carnation lines, developed by Florigene Pty Ltd, have been approved for commercialization. In this study, both methods were tested on 14 different carnation cultivars, and identical amplification products were obtained with all of them. No amplification products were observed with samples from 14 other plant species, which demonstrated that the system was specific to carnation. The results of Southern blot analysis confirmed that the ANS gene had a low copy number in the 10 tested carnation varieties. In qualitative and real-time PCR assays, the LOD values of 0.05 and 0.005 ng carnation DNA, respectively, were validated. Moreover, the real-time PCR system was validated with high PCR efficiency and linearity. Thus, the ANS gene had species specificity, low heterogeneity, and low copy number among the tested cultivars. These results provide evidence that the gene can be used as an endogenous reference gene of carnation, as well as in qualitative and quantitative PCR systems.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号