首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A functional polymer (hydroxylated polymethacrylate) coated on porous polysulfone hollow fiber membrane (PS-HFM) was used as an adsorbent for the extraction of alkylphenols and bisphenol-A from seawater samples. Analyses of the extracts were performed using gas chromatography-mass spectrometry (GC-MS) after injection-port derivatization using bis(trimethylsilyl)trifluoroacetamide (BSTFA). We term the procedure as polymer-coated hollow fiber microextraction (PC-HFME). Owing to high porosity PS-HFM coated with hydroxylated polymer showed high extraction efficiency. Compared with solid-phase microextraction (SPME), PC-HFME showed good selectivity and sensitivity. Detection limits of alkylphenols and bisphenol-A ranged between 0.07 and 2.34 ng l(-1). The linearity range was from 0.01 to 15 microg l(-1) and the correlation coefficient (r) up to 0.997. The sensitivity and selectivity of the coated HFM could be potentially tuned by changing the characteristics of the coated hydroxylated polymer. The PC-HFME procedure was applied to the detection of alkylphenols and bisphenol-A in the coastal waters of Singapore.  相似文献   

2.
In this work, a novel microextraction method termed polymer-coated hollow fiber microextraction (PC-HFME) was developed in combination with capillary electrophoresis (CE). Polar dihydroxylated polymethylmethacrylate polymer was coated onto a porous propylene hollow fiber membrane and used as an adsorbent and that was placed in a stirred aqueous sample solution. Tumbling of the extraction device within the sample solution facilitated extraction. The amino alcohols (2-amino-1-phenylethanol, norephedrine, alprenolol and atenolol which are beta-blocker drugs), were used as model compounds to investigate the extraction performance. No organic solvent was used in this procedure. The extract was then further concentrated through on-column stacking (normal stacking mode) during CE analysis. The detection limits ranged from 0.9 to 7 ng ml(-1). Relative standard deviations (n=6) ranged from 4 to 6%. The extraction of the amino alcohols in spiked wastewater effluent (representing a complex matrix) was evaluated using the developed procedure.  相似文献   

3.
A novel dihydroxy-terminated benzo-15-crown-5 is synthesized and applied to prepare the solid-phase microextraction (SPME) fiber coating with sol-gel technology. Headspace SPME, as a simple, solvent-free method, is applied to the analysis of 16 organochlorine pesticides (OCPs) present at trace levels in a water sample. A homemade crown ether fiber coated with 80- micro m thickness was used for extraction. Analyses are performed using gas chromatography-electroncapture detection. The optimization of the extraction process is studied. Compared with commercially available SPME fibers, polydimethylsiloxane, the new phases show better selectivity and sensitivity toward OCPs. The linear concentrations range from 1 to 1000 ng/L, the detection limits are in the range of 0.01-0.5 ng/L, the recoveries are over 85%, and relative standard deviations are below 7.2% for these OCPs.  相似文献   

4.
A porous polypropylene hollow fiber membrane (HFM)-protected solid-phase microextraction (HFM-SPME) procedure in conjunction with gas chromatography/mass spectrometric analysis for use in the determination of triazine herbicides in bovine milk samples is described. A 65-microm polydimethylsiloxane-divinylbenzne (PDMS-DVB) SPME fiber was protected by an HFM. HFM-SPME experimental parameters such as fiber type, extraction time, extraction temperature and salt concentration were investigated and optimized. The relative standard deviations for the reproducibility of the optimized HFM-SPME method varied from 4.30 to 12.37%. The correlation coefficients of the calibration curves were between 0.9799 and 0.9965 across a concentration range of 0-200 microg l(-1). The method detection limits for triazines in bovine milk were in the range of 0.003-0.013 microg l(-1) and limits of quantification were in the range of 0.006-0.021 microg l(-1). The suitability of HFM-SPME was extended to the analysis of the herbicides in sewage sludge samples. The results demonstrate that HFM-SPME was an efficient pretreatment and enrichment procedure for complex matrices.  相似文献   

5.
A simple and rapid liquid-phase microextraction (LPME) method using a hollow fiber membrane (HFM) in conjunction with gas chromatography-mass spectrometry (GC-MS) is presented for the quantitative determination of 16 polycyclic aromatic hydrocarbons (PAHs) and 12 organochlorine pesticides (OCPs) in rainwater samples. The LPME conditions were optimized for achieving high enrichment of the analytes from aqueous samples, in terms of hollow fiber exposure time, stirring rate, sample pH, and composition. Enrichment factors of more than 100 could be achieved within 35 min of extraction with relative standard deviations (R.S.D.s) 1.3-13.6% for PAHs and 1.7-13.8% for OCPs, respectively, over a wide range of analyte concentrations. Detection limits ranged from 0.002 to 0.047 microg l(-1) for PAHs, and from 0.013 to 0.059 microg l(-1) for OCPs, respectively. The newly developed LPME-GC-MS method has been validated for the analysis of PAHs and OCPs in rainwater samples. Extraction recoveries from spiked synthetic rainwater samples varied from 73 to 115% for PAHs and from 75 to 113% for OCPs, respectively. Real rainwater samples were analyzed using the optimized method. The concentrations of PAHs and OCPs in real rainwater samples were between 0.005-0.162, and 0.063 microg l(-1), respectively.  相似文献   

6.
In this study, a novel graphene nanosheets (GNSs) coated solid phase microextraction (SPME) fiber was prepared by immobilizing microwave synthesized GNSs on a stainless steel wire. Microwave synthesized GNSs were verified by X-ray diffraction, field emission-scanning electron microscopy (FE-SEM) and transmission electron microscope (TEM). GNS-SPME fiber was characterized using FE-SEM and the results showed the GNS coating was homogeneous, porous, and highly adherent to the surface of the stainless steel fiber. The performance and feasibility of the GNS-SPME fiber was evaluated under one-step microwave assisted (MA) headspace (HS) SPME followed by gas chromatography with electron capture detection for five organochlorine pesticides (OCPs) in aqueous samples. Parameters influencing the extraction efficiency of MA-HS-GNS-SPME such as microwave irradiation power and time, pH, ionic strength, and desorption conditions were thoroughly examined. Under the optimized conditions, detection limits for the OCPs varied between 0.16 and 0.93 ng L(-1) and linear ranges varied between 1 and 1500 n gL(-1), with correlation coefficients ranging from 0.9984 to 0.9998, and RSDs in the range of 3.6-15.8% (n=5). In comparison with the commercial 100 μm polydimethylsiloxane fiber, the GNS coated fiber showed better extraction efficiency, higher mechanical and thermal stability (up to 290°C), longer life span (over 250 times), and lower production cost. The method was successfully applied to the analysis of real water samples with recoveries ranged between 80.1 and 101.1% for river water samples. The results demonstrated that the developed MA-HS-GNS-SPME method was a simple, rapid, efficient pretreatment and environmentally friendly procedure for the analysis of OCPs in aqueous samples.  相似文献   

7.
A simple and novel analytical method for quantifying persistent organic pollutants (POPs) in marine sediments has been developed using microwave assisted solvent extraction (MASE) and liquid-phase microextraction (LPME) using hollow fibre membrane (HFM). POPs studied included twelve organochlorine pesticides (OCP) and eight polychlorinated biphenyl (PCB) congeners. MASE was used for the extraction of POPs from 1 g of sediment using 10 ml of ultrapure water at 600 W for 20 min at 80 degrees C. The extract was subsequently subjected to a single step LPME-HFM cleanup and enrichment procedure. Recovery varied between 73 and 111% for OCPs; and 86-110% for PCBs, and exceeded levels achieved for conventional multi-step Soxhlet extraction coupled with solid-phase extraction. The method detection limit for each POP analyte ranged from 0.07 to 0.70 ng g(-1), and peak areas were proportional to analyte concentrations in the range of 5-500 ng g(-1). Relative standard deviations of less than 20% was obtained, based on triplicate sample analysis. The optimized technique was successfully applied to POP analysis of marine sediments collected from the northeastern and southwestern areas of Singapore's coastal environment.  相似文献   

8.
A solvent bar microextraction (SBME) technique combined with gas chromatography/tandem mass spectrometry (GC/MS/MS), for the determination of selected organochlorine pesticides (OCPs) in wine samples, is described. In this work the OCPs were extracted and dissolved in a 2-microL aliquot of organic extraction solvent (n-tetradecane) confined within a 1.7-cm length of hollow fiber. Both ends of the hollow fiber (solvent bar) were sealed, and it was placed in an aqueous sample solution for extraction. The effects of solvent selection, sample agitation, extraction time, extraction temperature, and salt concentration on the SBME performance were optimized. The influence of aqueous sample/organic solvent phase ratio was further investigated in detail. High enrichments (1900-7100-fold) could be obtained at an aqueous sample/organic solvent volume ratio of 20 mL/2 microL in this study. Good extraction reproducibility was obtained with relative standard deviation (RSD) values below 12.6%. Comparisons of sensitivity and precision between SBME and dynamic hollow-fiber liquid-phase microextraction were also investigated.  相似文献   

9.
Yuling Hu 《Talanta》2010,80(5):2099-46
The combination of molecular imprinting and solid-phase microextraction (SPME) technique provides a powerful sample preparation tool in terms of selectivity, simplicity, and flexibility. This paper reports a novel molecularly imprinted polymer (MIP) coated SPME fiber with 17β-estradiol as template by improved multiple co-polymerization method. The obtained fiber exhibits excellent characteristics such as high porosity, good thermal and chemical stability. Extraction performance shows that the MIP-coated fiber has stronger affinity to the template molecule as compared with the commercial SPME fibers and the control polymer-coated fiber without addition of template. Owing to the shape and structural compatibility, the obtained fiber also demonstrated specific selectivity to the structural related compounds of 17β-estradiol, such as estriol, estrone and 17α-ethynylestradiol, and thus can be applied to simultaneous determination of these estrogens from complex samples coupled with high performance liquid chromatography. The variables that influence extraction were investigated. The MIP-coated fiber demonstrated its efficiency for extraction of estrogens in fishery samples. The detection limits were in the range of 0.98-2.39 μg L−1, and the recoveries were 80.0-83.6% and 85.0-94.1% for fish and shrimp tissue samples, respectively.  相似文献   

10.
Polyphenylmethylsiloxane (PPMS) as a novel coating for solid-phase microextraction (SPME) combined with microwave-assisted extraction (MAE) has been applied to determine the concentrations of organochlorine pesticides (OCPs) in Chinese teas. The characteristics of PPMS fiber, the extraction modes of SPME, the extraction time, temperature, and salt effects were investigated. Microwave irradiation time and power were also studied. Compared with commercial polydimethylsiloxane (PDMS) fiber and homemade sol-gel polymethylsiloxane (PMS) fiber, the novel porous sol-gel PPMS fiber exhibited high sensitivity and selectivity for OCPs compounds, higher thermal stability (to 350 degrees C) and long service life (more than 150 times). The recoveries of MAE is compared with that of ultrasonic extraction (USE), MAE-SPME-gas chromatography (GC)/electron-capture detection (ECD) methods showed better results for Chinese teas. Linear ranges of OCPs in the blank green tea was 0.1-10(3) ng/l. Detection limits of this method are below 0.081 ng/l. Recoveries of this method are between 39.05 and 94.35%. The repeatability of the technique was less than 16% relative standard deviation (R.S.D.). The tested pesticides in three Chinese teas were at the ng/g level.  相似文献   

11.
A liquid-phase microextraction (LPME) method has been demonstrated for the extraction and determination of organochlorine pesticides (OCPs) in aqueous solution. The method combines a dual gauge microsyringe with a hollow fiber membrane (LPME/DGM-HF) followed by detection by gas chromatography/ion trap mass spectrometry (GC/ITMS). The advantages include speed, low solvent and sample consumption, simplicity and ease of use. The extraction time, solvent selection, salt concentration and sample stirring rate have been investigated in order to optimize extraction efficiency. The viability is evaluated by measuring the linearity and detection limit of the five OCPs in aqueous solution. Detection linearity for the OCPs has been achieved over a range of concentrations between 1 and 500 microg/L (r2 > 0.930), with a detection limit of 0.1 microg/L for each OCP.  相似文献   

12.
The dynamic hollow fiber protected liquid phase microextraction (DHFP-LPME) technique was evaluated for the extraction of organochlorine pesticides (OCPs) in green tea leaves and ready-to-drink tea prior to gas chromatography combined-electron capture detection (GC-ECD) analysis. A conventional microsyringe with a 1.5 cm length of hollow fiber attached to its needle was connected to a syringe pump to perform the extraction. The microsyringe was used as both the microextraction device and the sample introduction device for GC-ECD analysis. In this work, the organochlorine pesticides were extracted and condensed to a volume of 3 microl of organic extracting solvent (1-octanol) confined within a 1.5 cm length of hollow fiber. The effects of extraction solvent, extraction time, sample agitation, plunger speed, and extraction temperature and salt concentration content on the extraction performance were also investigated. Good enrichments were achieved (34-297-fold) with this method, and good repeatabilities of extraction were obtained, with full name (RSDs) below 12.57%. Detection limits were much below 1 microg l(-1) for ready-to-drink tea and much below 1 microg g(-1) for green tea leaves.  相似文献   

13.
The feasibility of single-walled carbon nanotubes (SWCNTs) as adsorbents for solid-phase microextraction was investigated by using organochlorine pesticides (OCPs) as model compounds. SWCNTs were attached onto a stainless steel wire through organic binder. Potential factors affecting the extraction efficiency were optimized, including extraction time, extraction temperature, desorption time, desorption temperature, and salinity. The developed method has a linear range of 2-800 ng/L for most analytes, with coefficients of correlation ranging from 0.9911 to 0.9996, LODs ranged from 0.19 to 3.77 ng/L (S/N = 3), and RSDs in the range of 3.5-13.9% (n = 5). Compared with the commercial PDMS fiber, the SWCNT fiber has better thermal stability (over 350 degrees C) and longer life span (over 150 times). The developed method was applied to determine trace OCPs in lake water and wastewater samples with external standard calibration. Results showed that OCP contamination was very low in these samples, and HCHs were detected in almost all water samples while DDT concentrations were almost under detection limits in these samples. Recoveries obtained at 20 ng/L spiking level were in the range of 88.4-111% for OCPs in lake water. For wastewater samples, however, the recoveries were satisfactory for HCHs (63.6-97.1%) but relatively low for DDTs (44.7-116%) due to the high content of organic matter in wastewater.  相似文献   

14.
A novel C18 functionalized graphene oxide (GO) coated solid-phase microextraction fiber was prepared by a novel protocol. Based on the strong van der Waals interaction present in GO and abundant oxygenous groups in GO sheets, a simple layer-by-layer self-assembly method was used in the preparation process and then C18 was successfully self-assembled on GO via C-O-Si bonding. Coupled with gas chromatography, extraction performance of the fiber was tested with polycyclic aromatic hydrocarbons (PAHs) as model analytes. The fiber not only exhibited excellent extraction efficiency and selectivity, but also showed many advantages including high rigidity, long service life and well stability toward organic solvent, acidic and alkali solutions, and high temperature. The relative standard deviations for single-fiber repeatability and fiber-to-fiber reproducibility were less than 7.26 and 17.25%, respectively. The detection limits to the PAHs were less than 0.08 μg L(-1) and the calibration curves were linear in a wide range for all analytes. The as-established Solid-phase microextraction GC method was also successfully used for determination of PAHs in two real water samples.  相似文献   

15.
Porous polypropylene hollow fiber membrane coated with a conjugated polymer was used as an on-site sampling device for the extraction of polychlorinated biphenyls and polybrominated biphenyl ethers from coastal sea water samples. The coated hollow fiber membrane was placed in a vial containing the sample, and the target compounds extracted via manual shaking of the vials at the site of sample collection. For each extraction, two fibers were used. After extraction, the fibers with the adsorbed analytes were brought back to the laboratory for further processing. Care was taken to preserve the integrity of the analytes and to avoid contamination during transport; after extraction, the fibers were carefully removed and placed in air-tight crimper vials which were stored in an ice-box. The analytes were desorbed by solvent in the laboratory and analyses were carried out using gas chromatography/mass spectrometry. This method was highly reproducible with relative standard deviations in the range of 1-9%. Recoveries from spiked water samples ranged from 83% to 98%. Low limits of detections between 0.04 and 0.21ngl(-1) were achieved. The extraction efficiency was compared with solid-phase microextraction.  相似文献   

16.
Dynamic liquid-phase microextraction (LPME) controlled by a programmable syringe pump was evaluated for extracting pesticides in water prior to GC-MS analysis. A conventional microsyringe with a 1.3-cm length of hollow fiber attached to its needle was connected to a syringe pump to perform the extraction. The microsyringe was used as both the microextraction device as well as the sample introduction device for GC-MS analysis. The attached hollow fiber served as the "holder" and protector" of 3 microl of organic solvent. The solvent was repeatedly withdrawn into and discharged from the hollow fiber by the syringe pump. Pesticides were extracted from 4-ml water samples into the organic solvent impregnated in the hollow fiber. The effects of organic solvents, plunger movement pattern, agitation and extraction time were investigated. Good repeatabilities of extraction performance were obtained, with the RSD values ranging from 3.0% (alachlor) to 9.8% (4-chlorophenol) for the 14 pesticides; most RSD values were under 5.0%. The method provided a 490-fold preconcentration of the target pesticides. The limits of detection were in the range of 0.01-5.1 microg/l (S/N = 3) in the GC-MS selected ion monitoring mode. In addition, sample clean-up was achieved during LPME because of the selectivity of the hollow fiber, which prevented undesirable large molecules from being extracted. A slurry sample (mixture of 40 mg soil/ml of water) containing seven pesticides was extracted using this method which also gave good linearity and precision (most RSDs <7.0%, n = 3).  相似文献   

17.
An analytical procedure was developed using headspace solid-phase microextraction (HS-SPME) for the determination of organochlorine pesticides (OCPs) and their metabolites in sandy soil samples. The developed procedures involving fiber selection, temperature effect, absorption time, soil matrix and the addition of solvents of different polarity were optimized. Also, the results were compared to those achieved using Soxhlet extraction standard method. The 100-microm polydimethylsiloxane (PDMS) and 65-microm PDMS-divinylbenzene showed good extraction efficiency for 18 organochlorine pesticides. An increase in the extraction efficiency of organochlorine pesticides and the metabolites was observed when the temperature increased, and an optimum temperature of 70 degrees C for extracting OCPs was obtained. The application of other hydrophilic solvents had different effects on the extraction of organochlorine pesticides and the metabolites. Higher responses of OCPs were obtained when 5 ml of water was added to the soil. Good linearity of OCPs between 0.2 and 4 ng/g soil was observed. The relative standard deviation was found to be lower than 25%. Also the limits of detection were between 0.06 and 0.65 ng/g, which were lower than those obtained using Soxhlet extraction. Moreover, the optimized HS-SPME procedure was applied to the analysis of OCPs in certified reference material (CRM) 804-050 soil and compared with Soxhlet extraction procedure. Results obtained in this study were in good agreement with those obtained using Soxhlet extraction. The mean values obtained using HS-SPME technique were in the range of 16.5 to 1459.6 mg/kg, which corresponds to the recoveries of 68% to 127% of the certified values of CRM soil.  相似文献   

18.
This paper describes the extraction of 20 organochlorine pesticides (OCPs) from water samples using solid-phase microextraction (SPME). Three fused-silica fibers coated or bonded with polydimethylsiloxane (PDMS) of different film thicknesses (20-, 30-, and 100-μm) were evaluated. The extraction time, the effects of stirring and addition of NaCl to the aqueous sample, the linear range and the precision of this technique, and the effect of carryover were examined for 20 analytes and are presented here. A comparison with results using conventional liquid-liquid extraction demonstrate that the SPME technique is well suited as a fast screening technique for OCPs in water samples.  相似文献   

19.
Ionic liquids (ILs) are novel nonmolecular solvents. Their unique properties, such as high thermal stability, tunable viscosity, negligible vapor pressure, nonflammability, and good solubility for inorganic and organic compounds, make them excellent candidates as extraction media for a range of microextraction techniques. Many physical properties of ILs can be varied, and the structural design can be tuned to impart the desired functionality and enhance the analyte extraction selectivity, efficiency, and sensitivity. This paper provides an overview of the applications of ILs in liquid phase microextraction technology, such as single‐drop microextraction, hollow fiber based liquid phase microextraction, and dispersive liquid–liquid microextraction. The sensitivity, linear calibration range, and detection limits for a range of target analytes in the methods were analyzed to determine the advantages of ILs in liquid phase microextraction.  相似文献   

20.
Amphiphilic and hydrophilic oligomers were synthesized and coated on fused silica capillaries using a sol-gel technique. Sol-gel-coated capillaries were evaluated for the solid-phase microextraction and preconcentration of a wide variety of non-polar and polar analytes. Both types of coatings were stable under high temperature (up to 280 degrees C). The extraction efficiency of the sol-gel coatings was evaluated for the extraction of both non-polar and polar analytes, including organochlorine pesticides, triazine herbicides, estrogens and alkylphenols (APs) and bisphenol-A (BPA). Compared with commercially available solid-phase microextraction (SPME) adsorbents such as poly(dimethylsiloxane)divenylbenzene and polyacrylate, the new materials showed comparable selectivity and sensitivity towards both non-polar and polar analytes. The new coatings gave good linearity and detection limits. For example with triazines, a detection limit of <0.005 microl l(-1), precision from 5.0 to 11.0% (n = 6) and linearity of the calibration plots (0.5 to 50 microl l(-1)) were obtained. The sol-gel coated SPME capillaries were used for the determination of triazine herbicides in reservoir water samples collected in Singapore.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号