首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A surface modification has been developed which yields fused silica capillaries with switchable electroosmotic flow (anodal/cathodal). The capillary surface is a composite material consisting of unreacted silanol groups, a layer of positively charged quaternary ammonium functions, and a hydrophilic layer of long polyether chains. Because of the presence of positively and negatively charged groups, the net charge of the capillary surface can be varied from positive to negative by changing the pH of the running electrolyte, thus enabling manipulation of the magnitude and direction of the electroosmotic flow. The long polyether chains were effective in shielding biomacromolecules from the charged inner surface of the capillary, thus minimizing electrostatic interaction of the solutes with both unreacted silanols and the quaternary ammonium groups which had been introduced. As a consequence, high separation efficiencies were achieved with proteins, nucleotides, and a series of acidic oligosaccharides.  相似文献   

2.
Amon S  Plematl A  Rizzi A 《Electrophoresis》2006,27(5-6):1209-1219
Defined conditions of EOF along with different pH values of the BGE were compared for the purpose of analyzing glycopetides by CZE coupled to MS (CZE-MS). Hyphenation to MS involved ESI as well as MALDI, and single-stage and multistage MS were applied. Variation of the EOF was accomplished by selecting appropriate coatings for the capillary, namely hexadimethrine bromide (HDMB) and HDMB/dextran sulfate. A high and reproducible anodic and cathodic EOF, respectively, was obtained in both approaches, allowing the detection of analytes with net positive as well as negative charge in one single run. Thus, a fast and sensitive determination of the glycopeptides in a tryptic digest of antithrombin, chosen as a test sample, was achieved. Ionization suppression effects, a phenomenon typically observed with glycopeptides in MS analysis, were minimized thanks to separation from other peptides present. The high stability of the coatings permitted the generation of mass spectra without interfering peaks originating from the coating polymers. The high EOF generated by the coatings facilitated the maintenance of a stable spray when coupling to ESI-MS, and a stable CZE current when working with a sheath flow-assisted analyte deposition onto MALDI targets, respectively. In conclusion, CZE-MS could be demonstrated as a robust complementary method to capillary RP-HPLC-MS in combination with both soft-ionization techniques, ESI and MALDI, generally, and particularly in the context of glycopeptide analysis.  相似文献   

3.
4.
UV-absorbing neutral substances are commonly used as markers of mean electroosmotic flow in capillary electrophoresis for their zero electrophoretic mobility in an electric field. However, some of these markers can interact with background electrolyte components and migrate at a different velocity than the electroosmotic flow. Thus, we tested 11 markers primarily varying in their degree of methylation and type of central atom in combination with five background electrolyte cations differing in their ionic radii and surface charge density, measuring the relative electrophoretic mobility using thiourea as a reference marker. Our results from this set of experiments showed some general trends in the mobilization of the markers based on the effects of marker structure and type of background electrolyte cation on the relative electrophoretic mobility. As an example, the effects of an inadequate choice of marker on analyte identification were illustrated in the electrophoretic separation of glucosinolates. Therefore, our findings may help electrophoretists appropriately select electroosmotic flow markers for various electrophoretic systems.  相似文献   

5.
On-line sample concentration of fast moving inorganic anions by large volume sample stacking (LVSS) and field enhanced sample injection (FESI) with a water plug under acidic conditions is presented. Detection sensitivity enhancements were around 100 and 1000-fold for LVSS and FESI, respectively. However, reproducibility and linearity of response in the LVSS approach is superior compared to the FESI approach.  相似文献   

6.
This paper investigates two-dimensional, time-dependent electroosmotic flow driven by an AC electric field via patchwise surface heterogeneities distributed along the micro-channel walls. The time-dependent flow fields through the micro-channel are simulated for various patchwise heterogeneous surface patterns using the backwards-Euler time stepping numerical method. Different heterogeneous surface patterns are found to create significantly different electrokinetic transport phenomena. The transient behavior characteristics of the generated electroosmotic flow are then discussed in terms of the influence of the patchwise surface heterogeneities, the direction of the applied AC electric field, and the velocity of the bulk flow. It is shown that the presence of oppositely charged surface heterogeneities on the micro-channel walls results in the formation of localized flow circulations within the bulk flow. These circulation regions grow and decay periodically in phase with the applied periodic AC electric field intensity. The location and rotational direction of the induced circulations are determined by the directions of the bulk flow velocity and the applied electric field.  相似文献   

7.
Capillaries consisting of two segments each packed with a different stationary phase were introduced for the control and manipulation of the electroosmotic flow (EOF) in capillary electrochromatography (CEC). This kind of column configuration was called segmented capillary where one segment was packed with octadecyl silica (ODS) and served as the separation segment while the other segment was packed with bare silica and functioned as the EOF accelerator segment. The average flow in the segmented capillary increased linearly with increasing fractional length of the EOF accelerator segment, and consequently the analysis time was reduced. Under a given set of conditions, the average flow can be varied over a certain range that extends from the EOF in the individual ODS capillary at the lower end to the EOF in the individual bare silica capillary at the higher end. The pore size of the bare silica in the EOF accelerator segment influenced the average flow in the segmented capillary. Because of the difference in the EOF of the individual segments, the average flow across the segmented capillary is partially degenerated from EOF to viscous flow. Furthermore, the retaining frits in CEC columns are restrictive points which slow down the average flow, thus furthering the degeneration of the flow from EOF to viscous flow. In other words, in CEC columns containing retaining frits, the flow of the mobile phase is not only based on electroosmosis but is contaminated by a viscous component.  相似文献   

8.
The present article describes a capillary zone electrophoresis method which relies on a multilayered water-alkali solvent stacking with online ionization to enhance detection of mannose, arabinose, and their oligosaccharides, which are used as the migration profile standards but are also the distinctive structural components of lipoarabinomannan. Lipoarabinomannan is detected in patients having tuberculosis. The capillary electrophoresis method with ionization of the whole saccharides without degradation in alkaline solution inside the capillary is based on the structural deprotonation of the molecules under ultrahigh pH conditions. The validation of the capillary electrophoresis parameters revealed that the 15-fold electrolyte–water-injection plug allowed detection of one-third lower concentrations than detected without online concentration. For the first time, the better detectability was seen especially for highly polymerized, but otherwise poorly ionized, arabinooctaose. The applicability of the method for detecting whole large biological saccharide complexes was confirmed by the glycolipid lipoarabinomannan. For the first time also, the migration of the indestructible lipoarabinomannan was detected together with oligosaccharides used representing the capping units, namely mannose, mannobiose, and mannotriose. The myo-inositol-phosphate-lipid unit was seen to migrate separately from the arabinomannan, since it was hydrolyzed from one lipoarabinomannan product under alkaline conditions in capillary electrophoresis.  相似文献   

9.
Capillary zone electrophoresis has been tested for the separation of angiotensins, cationic heptapeptides and model histidine derivatives. Good separation efficiencies are seen for peptides and model compounds with negative to small positive net charges. For net charge greater than +2, addition of putrescine to pH 6 buffer greatly suppresses ion exchange at anionic sites on fused silica. When operating at pH values where histidine groups are neutral, addition of Zn2+ allows separations based on metal, rather than proton, binding. Separation efficiencies and relative migration times are dependent on capillary length when ion-exchange behavior occurs.  相似文献   

10.
郭振朋  王晓瑜  陈义 《色谱》2017,35(1):65-69
赤霉素是一类重要的植物激素,是结构相似的弱酸性二萜类化合物。针对毛细管电泳法分离、测定赤霉素速度慢、效率不佳等问题,该文发展了一种可快速测定微量活性赤霉素的非水毛细管电泳-紫外检测法。以聚环氧乙烷动态涂布毛细管,利用正离子使电渗流反向,将含10 mmol/L醋酸铵的甲醇-水(95∶5,v/v)作为缓冲体系,在0.08%(v/v)醋酸含量下,分离8种内源性赤霉素。结果表明,赤霉素出峰时间的相对标准偏差(RSD)≤2.1%(日内)或≤4.3%(日间),峰面积的RSD≤4.5%(日内)或≤6.9%(日间),检出限(S/N=3)为1.04~2.20 mg/L,相关系数为0.998 2~0.999 3,回收率为87.2%~93.5%。该方法简单、快速、稳定,以含醋酸铵的甲醇水溶液为缓冲体系,预先考虑了质谱测定的需要,可用于实际样品如麦芽中赤霉素的分析,具有一定的应用价值。  相似文献   

11.
Phillies GD 《Electrophoresis》2012,33(6):1008-1012
Capillary electrophoresis with a polymer solution support medium is a well-established powerful analytical tool. This paper discusses a possible alternative application of capillary electrophoresis, namely a path for studying the dynamics of polymer solutions. The key to the approach is an inversion of perspective. Instead of treating the migrating species as the object of experimental importance and the support medium as being of importance only because it facilitates separations, one treats the polymer solution as being of experimental importance, and the choice of migrating species as being of interest only because different species may probe different aspects of polymer dynamics.  相似文献   

12.
13.
Quantitative SNP detection was demonstrated with an ACE using a PEG-oligodeoxyribonucleotide block copolymer (PEG-b-ODN) as a probe in the presence of an EOF. The probe's PEG segment with large molecular weight and small polydispersity yielded a high resolution in the separation of a chemically synthesized 60-base ssDNA (WT) and its single-base-substituted mutant (MT). A mixture of WT and MT was clearly separated within 10 min by simultaneously using two types of PEG-b-ODN probes whose ODN segments were complementary to WT and MT and whose PEG segments were of different lengths. The peak area ratio between WT and MT was in good agreement with the feed ratio. The averaged difference between the feed and observed ratio of MT was determined to be 0.23%, which is lower than that of any other methods. The ACE using the PEG-b-ODN probes in the presence of EOF could be utilized as a facile method for estimating SNP allele frequency in various research fields.  相似文献   

14.
Recently the use electric field gradient focusing (EFGF) to enhance focusing of proteins has been proposed and explored to provide significant improvement in separation resolution. The objective of EFGF is to focus proteins of specific electrophoretic mobilities at distinct stationary locations in a column or channel. This can be accomplished in a capillary by allowing the electric potential to vary in the streamwise direction. Because the electric field is varying, so also is the electrokinetic force exerted on the proteins and the electroosmotic velocity of the buffer solution. Due to the varying electric field, the Taylor diffusion characteristics will also vary along the column, causing a degradation of peak widths of some proteins, dependent on their equilibrium positions and local velocity distributions. The focus of this paper is an analysis that allows characterization of the local Taylor diffusion and resulting protein band peak width as a function of the local magnitude of the EOF relative to the average fluid velocity for both cylindrical and rectangular channels. In general the analysis shows that as the ratio of the local electroosmotic velocity to the average velocity deviates from unity, the effective diffusion increases significantly. The effectiveness of EFGF devices over a range of protein diffusivities, capillary diameters, flow velocities, and electric field gradient is discussed.  相似文献   

15.
A new and specific precolumn derivatization reaction for acidic monosaccharides was introduced and evaluated in the separation and sensitive detection of carbohydrates by capillary electrophoresis. The derivatization reaction involved the attachment of sulfanilic acid (a UV absorbing tag) or 7-aminonaphthalene-1,3-disulfonic acid (a UV absorbing and fluorescing tag) via a condensation reaction between the amino group of the derivatizing agent and the carboxyl group of the sugar in the presence of a water-soluble carbodiimide. The derivatization reaction replaced the weak carboxylic acid of the sugar by a strong sulfonic acid, which is fully ionized at all pH. This allowed the electrophoresis of the sugar derivatives over a wide pH range and permitted the determination of acidic carbohydrates at very low femtomole levels by UV and fluorescence detection.  相似文献   

16.
Capillary zone electrophoresis (CZE) was employed in polyimide composition analysis. Polymide was decomposed to its corresponding aromatic diamine and aromatic acid monomers by an alkali fusion reaction. Sample treatment is much simpler than published methods, and electropherograms show a good separation of decomposed products under the proper conditions.  相似文献   

17.
Summary Based on the Einstein-Nernst equation, describing the relation between diffusion coefficient and ionic mobility, and expression for the plate height and plate number can be obtained which is independent of the diffusion coefficient. This approach was supported by experimental data, obtained from anionic and cationic solutes. An expression for the electrophoretic resolution is introduced that is also independent on diffusion coefficients. The effect of electro-osmotic flow on the separation of anions and cations based on the expressions derived for the plate number and the resolution is discussed.  相似文献   

18.
This paper presents an in-depth look at the use of capillary electrophoretic (CE) techniques for the fingerprinting and characterization of humic substances and natural organic matter. These materials are highly heterogeneous in structure and show all characteristics of mixtures unliked in analytical chemistry. The electrophoretic approach, however, allows the determination of mobility distributions in different solution conditions, representative of the effective charge and size distribution status of the components present. A tabulated review covers over 50 references on the subject and highlights the possibilities and problems encountered in the analysis of such polydisperse materials with CE methods. In a second part of the article the consequences of experimental and buffer parameters on the behavior of humic materials in CE are presented.  相似文献   

19.
In aqueous capillary electrophoresis the electroosmotic flow (EOF) can be strongly suppressed or eliminated by coating the capillary surface silanols either by buffer additive adsorption or chemical modification. Hydrophilic coatings, e.g., polyvinyl alcohol (PVA) proved to be most efficient for EOF control in applications like DNA analysis. In nonaqueous capillary electrophoresis (NACE), however, the EOF cannot be totally suppressed with these capillaries and coating efficiency turned out to be solvent-depending. In this paper, fused-silica capillaries with monomeric and polymeric coatings differing in hydrophobicity and chemical properties (vinyl, vinyl acetate, vinyl alcohol and acrylates with different alkyl chain length) were investigated. Besides studying the EOF characteristics with different organic solvents and water, gas chromatography (GC) measurements were carried out to probe the silanol reduction via ether retention and the surface hydrophobicity by retention of nonane. Good correlations between GC results and EOF magnitude could be found. It could be demonstrated that the polymeric coating has to be solvatized by the buffer solvent to reduce the EOF. The PVA coating was optimal for aqueous systems but not effective for some nonaqueous buffers. On the other hand, polyvinyl acetate and polyethyl acrylate as polymeric coatings proved to be optimal to reduce the EOF in NACE.  相似文献   

20.
A novel versatile method for the determination of low or high electroosmotic mobility values in microdevices of variable microchannel design is presented. The electroosmotic flow (EOF) calculation is based on the difference between the apparent and effective mobilities of a reference compound. The proposed method uses microchip frontal electrophoresis for the determination of these mobilities. This requires simple monochannel microchip design and demonstrates versatile and time-saving procedure when compared to conventional current monitoring method when measuring low EOF. It has been applied successfully to the characterization of different coating procedure in glass and poly(dimethylsiloxane) microchips.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏