首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Sorption of hydrogen in a palladium electrode with a limited volume has been studied using the quartz crystal microbalance (QCM). During the hydrogen sorption process in the palladium electrode, strains are generated inside the metal which result in changes in the frequency of the crystal. These stresses change in a non-linear manner during electrode saturation, with α- and β-phases. This effect creates significant problems with the objective estimation of the amount of sorbed hydrogen inside the palladium electrode using the QCM method. This method is more accurate for the study of electrode surface processes, i.e. specific anion adsorption on the electrode surface or electrode dissolution. Received: 6 August 1998 / Accepted: 1 December 1998  相似文献   

2.
The electrochemical quartz crystal microbalance (EQCMB) method has been used to evaluate the processes which occur in/on the palladium electrode in basic solutions. Hydrogen electrosorption in palladium is accompanied by an additional frequency shift that can be attributed to the stresses generated inside the Pd metal. A non-linear dependence between the mass change and the charge consumed during hydrogen oxidation in the Pd electrode has been found for hydrogen absorbed in the α- and β-phases. This effect precludes the objective estimation of the amount of hydrogen absorbed inside the Pd electrode. The EQCMB method has been used, however, for studying the surface electrode processes on the Pd electrode, i.e. specific anion adsorption, surface oxidation and dissolution. Also, the structure of the palladium oxide formed on the Pd surface during electrochemical oxidation is discussed in this paper and the effect of the anodic limiting potential on the oxide structure is reported. Received: 10 August 1999 / Accepted: 24 September 1999  相似文献   

3.
Sorption isotherms, sorption enthalpies, and diffusion coefficients for water in an 11 μm thick PEO/PAA multi-layer film have been measured at 30, 40, and 60 °C for relative humidities between 0 and 70%. All quantities were measured on the same film using the quartz crystal microbalance/heat conduction calorimeter. Water diffusion coefficients in the film are several orders of magnitude lower than in the separate components. Sorption isotherms are of type III at 30 and 40 °C and linear at 60 °C. Water vapor permeabilities are calculated as the product of Henry's law solubility and diffusion coefficient. The permeability of the PEO/PAA multilayer film is exceedingly low compared to other polymer films used as membranes. The enthalpy of water sorption determined from the sorption isotherms using the van’t Hoff relation is 32.9 ± 0.3 kJ/mol. Calorimetric enthalpies of water sorption range from 42 to 34 kJ/mol at 30 and 40 °C over the humidity range studied. The change in motional resistance, a quantity proportion to the loss compliance of the film, has also been recorded at all three temperatures, and a common trend is an increase in loss compliance with increasing relative humidity, indicating plasticization of the film by water.  相似文献   

4.
The electrochemical quartz crystal microbalance (EQCMB) method has been used to study the processes of hydrogen absorption/desorption in Pd-Ni alloy electrodes. It was found that hydrogen electrosorption is accompanied by an additional frequency shift, attributed to the stresses generated inside the alloy. The influence of stresses on the EQCMB response depends on the amount of absorbed hydrogen and the alloy composition. From the comparison of the EQCMB results with Pd-Ni alloy absorption capabilities data, it was concluded that the decrease of the hydrogen sorption capacity at a Ni content of ca. 25–30 at% is due to an excessive generation of stresses in the alloy lattice. Also, a dependency of the rate of hydrogen absorption in Pd-Ni alloys on potential is reported. Electronic Publication  相似文献   

5.
The quartz crystal microbalance/heat conduction calorimeter (QCM/HCC) is a versatile instrument coupling both gravimetric and calorimetric techniques. The QCM/HCC is used to probe vapor sorption in thin films. Three parameters are measured simultaneously as a thin film undergoes vapor sorption, namely: mass changes in the film (±10 ng), corresponding thermal effects upon vapor sorption (±100 nW), and motional resistance (±0.5Ω) changes within the film. A range of film thicknesses (0.75 to 8.5 μm) of the polymer, Tecoflex? are cast on QCMs and the interaction of each film with ethanol and water is determined. From the direct calorimetric measurements, sorption enthalpies (ΔsorptionH kJ/mol) are determined for the film–vapor interactions. Sorption isotherms are then analyzed for each film. The isotherms shown here generally display a linear Henry's Law dissolution relationship between the vapor pressure and the amount of vapor sorbed into the film. Motional resistance data provides a window to view viscoelastic effects of the polymer films upon vapor sorption. Motional resistance data are compared for ethanol sorption in a relatively thin (0.75 μm) and thicker (8.5 μm) Tecoflex? film. © 2004 Wiley Periodicals, Inc. J Polym Sci Part B: Polym Phys 42: 3893–3906, 2004  相似文献   

6.
Recent work performed at DERA (now QinetiQ) has shown how accelerating rate calorimetry (ARC) can be used to obtain time to maximum rate curves using larger samples of energetic materials. The use of larger samples reduces the influence of thermal inertia, permitting experimental data to be gathered at temperatures closer to those likely to be encountered during manufacture, transportation or storage of an explosive device. However, in many cases, extrapolation of the time to maximum rate curve will still be necessary. Because of its low detection limit compared to the ARC, heat conduction calorimetry can be used to obtain data points at, or below, the region where an explosive system might exceed its temperature of no return and undergo a thermal explosion.Paired ARC and heat conduction calorimetry experiments have been conducted on some energetic material samples to explore this possibility further. Examples of where both agreement and disagreement are found between the two techniques are reported and the significance of these discussed. Ways in which combining ARC and heat conduction calorimetry experiments can enhance, complement and validate the results obtained from each technique are examined.  相似文献   

7.
A study of biospecific interactions between lectins and glycoproteins using a quartz crystal microbalance biosensor with dissipation monitoring (QCM-D) was reported. Four lectins were covalently immobilised on the thiol-modified gold electrode of the QCM chips in order to obtain sensing surfaces. The frequency shift served as analytical signal and the dissipation shift provided additional information about the viscoelastic properties of the glycoprotein-lectin complex formed on the surface of the QCM chip. The working conditions of the assay were optimised. The interaction between different lectins and glycoproteins was characterised by specific frequency shifts and each glycoprotein displayed its own unique lectin-binding pattern. This lectin pattern can serve as a finger print for the discrimination between various glycoproteins. The biosensor enabled quantitative determination of glycoproteins in the concentration range of 50 μg mL−1 to 1 mg mL−1 with good linearity and R.S.D. of less than 6.0%. An additional advantage of the proposed biosensor was the possibility to re-use the same lectin surfaces during a long period of time (2 month) without changes in analytical response. This was experimentally achieved by the application of a proper regeneration solution (10 mM glycine-HCl, pH 2.5). The lectin-based quartz crystal microbalance technique is suitable both for rapid screening and for quantitative assay of serum glycoproteins.  相似文献   

8.
Gomes MT  Costa JR  Oliveira JA 《Talanta》2003,59(2):247-252
A sensor for sodium based on a piezoelectric quartz crystal is proposed. The quartz crystal was coated with 5% of bis[(12-crown-4)methyl] dodecylmethylmalonate, 33% of PVC and 62% of NPOE to which KTpClPB in a 22% molar proportion to the ionophore was added. Coating amounts producing a frequency decrease around 18 kHz show optimum linear calibration ranges for the analysis of sodium in commercial mineral waters. Besides sensitivity, coating stability and selectivity of the sensor over other cations were adequate for those analyses. The results obtained analysing commercial mineral waters by the proposed method are not significantly different (α=0.05) from the ones obtained by atomic spectrometry.  相似文献   

9.
Qi Kang 《Talanta》2007,72(4):1474-1480
A new data treatment method for the improvement of the signal-to-noise ratio of a quartz crystal microbalance (QCM) was proposed, where an averaged resonant frequency was calculated according to its conductance peak in an impedance analysis method. The relationship between the averaged resonant frequency and the medians of the conductance peak at different sampling heights was derived. It was shown that the signal-to-noise ratio of the averaged resonant frequency was about eight times of that of the resonant frequency calculated directly from its equivalent circuit parameters. The averaged resonant frequency of the QCM was applied to monitor the self-assembled process of a 6-O-(2′-(α-thiohydroxyacetamide)-ethyl)-diethoxylsilyl-β-cyclodextrin (OTED-β-CD), on gold surface as well as the adsorption of nitrophenol isomers onto the OTED-β-CD self-assembled monolayer film.  相似文献   

10.
We investigated the effects of the longitudinal wave on the immersion angle dependence of the resonant-frequency shift, ΔF, of the quartz crystal microbalance, QCM. In order to study exactly the effects, we employed the three types of cells: normal cell, cell with the glass beads and cell with sponge. The longitudinal wave exists in the normal cell. On the other hand, both the cell with the glass beads and the cell with sponge eliminate the longitudinal wave. As results, we have found that the tendencies of ΔF are the same in the three types of cells. That is, we conclude that the longitudinal wave does not have effects on the immersion angle dependence of ΔF.  相似文献   

11.
The electrochemical preparation of copper layers was investigated using a quartz crystal microbalance (QCM) with damping monitoring. The damping increase during the deposition could be separated into two contributions arising from an internal and an external friction process. External friction comes from the coupling of the shear motion of the rough metal surface to the viscous liquid. Internal friction occurred only in the coarse grained layers and can be explained by phonon excitations at the grain boundaries.Presented at the 3rd International Symposium on Electrochemical Processing of Tailored Materials held at the 53rd Annual Meeting of the International Society of Electrochemistry, 15–20 September 2002, Düsseldorf, Germany  相似文献   

12.
A new sensor based on oxidative combustion of nitroaromatics to NO2 and its detection with a quartz crystal microbalance (QCM) coated with copper phthalocyanine (CuPc) was developed for determination of nitroaromatics in landfill gas. An alternative method based on gas chromatography–mass spectrometry (GC–MS) was also used in order to assess the performance of the proposed method. The results show that the analytical apparatus based on the QCM is less expensive than the GC–MS, and that the analytical error is 0.8% for both methods.  相似文献   

13.
A new method for the quantitative determination of palladium(II) by the electrochemical quartz crystal microbalance (EQCM) technique has been developed. Using a bare carbon-coated quartz crystal, Pd(II) ions are directly deposited from aqueous solution as palladium metal onto the crystal surface, and the Pd(II) concentration is determined with a detection limit of 0.0156 mM, or 1.66 ppm. No complexing agent or preconcentration of palladium is required for the analysis. The palladium is stripped from the crystal through its electrochemical oxidation, regenerating the crystal for subsequent multi-cycle palladium analyses. A conventional gold-coated quartz crystal was incapable of carrying out the same measurements. The EQCM technique presented is simple, sensitive, and reproducible for the detection of this widely used precious metal.  相似文献   

14.
Tungsten oxide (WO3) nanoflakes were synthesized, and characterized by scanning electron microscopy, transmission electron microscopy and X-ray diffraction. Thermogravimetry and X-ray photoelectron spectroscopy demonstrate the existence of strongly bound surface water molecules on the surface of tungsten oxide nanoflakes. WO3 nanoflake functionalized quartz crystal microbalance sensors were fabricated, and firstly used for detection of trace sarin simulant, dimethyl methylphosphonate (DMMP). The sensors have better reproducibility and stability as well as much shorter response (30 s) and recovery time (73 s) than those functionalized by conventional hydrogen-bond acidic branched copolymers. The strongly bound surface water molecules on the surface of WO3 nanoflakes are believed to play a key role in achieving such excellent DMMP sensing characteristics.  相似文献   

15.
This study reports the fouling of carboxymethyl dextran (CMD) layers in cell culture medium, fibronectin, and serum solutions. CMD layers were covalently immobilized onto amine groups available either on an n-heptylamine plasma polymer (HApp) layer or onto a polyethylenimine (PEI) coating grafted to an acetaldehyde plasma polymer (AApp) layer. The successful immobilization of the graft layers was demonstrated by X-ray photoelectron spectroscopy (XPS). Primary amines on HApp and AApp + PEI surfaces were quantified using a colorimetric assay. Quartz crystal microbalance (QCM) was used to investigate in real-time the fouling of the graft layers upon incubation in cell culture medium (RPMI), fibronectin, and foetal bovine serum (FBS) solutions. HApp, AApp and AApp + PEI layers exhibited large fouling in fibronectin and FBS solutions, while fouling in RPMI cell culture medium was not significant. Protein repellent properties of CMD layers in FBS and fibronectin have been demonstrated compared to the other tested surfaces. QCM has shown that both CMD layers were fouled to a small extent in RPMI medium.  相似文献   

16.
基于分子印迹技术的丙溴磷压电石英晶体微天平研制   总被引:1,自引:0,他引:1  
介绍了一种用于检测丙溴磷农药的分子印迹压电生物传感器的构建方法。采用沉淀聚合法合成了农药丙溴磷的分子印迹聚合物,将其固定于石英晶体微天平电极表面构建传感器;采用环境扫描电镜以及原子力显微镜对聚合物形貌、传感器电极表面形貌特征进行分析,并利用传感器对丙溴磷农药进行检测分析,其质量浓度在10~1000 ng/mL范围内,传感器频率改变与丙溴磷浓度之间的响应呈线性关系,线性方程为y=0.139ρ+2.26(r=0.9984)。结果表明,构建的分子印迹压电生物传感器能够对农药进行初步检测,具有较高的灵敏性和较好的特异识别能力。  相似文献   

17.
The hemoglobin (Hb) released from erythrocytes is a primary nutritive component for many blood-feeding parasites. The aspartic protease cathepsin D is a hemoglobinase that is involved in the Hb degradation process and is considered an interesting target for chemotherapy intervention. However, traditional enzymatic assays for studying Hb degradation utilize spectrophotometric techniques, which do not allow real-time monitoring and can present serious interference problems. Herein, we describe a biosensor using simple approach for the real-time monitoring of Hb hydrolysis as well as an efficient screening method for natural products as enzymatic inhibitors using a quartz crystal microbalance (QCM) technique. Hemoglobin was anchored on the quartz crystal surface using mixed self-assembled monolayers. The addition of the enzyme caused a mass change (frequency shift) due to Hb hydrolysis, which was monitored in real time. From the frequency change patterns of the Hb-functionalized QCM, we evaluated the enzymatic reaction by determining the kinetic parameters of product formation (kcat). The QCM enzymatic assay using immobilized human Hb was shown to be an excellent approach for screening possible inhibitors in complex mixtures, opening up a new avenue for the discovery of novel inhibitors.  相似文献   

18.
Shen D  Kang Q  Li X  Cai H  Wang Y 《Analytica chimica acta》2007,593(2):188-195
This paper presents different experimental results of the influence of an immersion angle (θ, the angle between the surface of a quartz crystal resonator and the horizon) on the resonant frequency of a quartz crystal microbalance (QCM) sensor exposed one side of its sensing surfaces to liquid. The experimental results show that the immersion angle is an added factor that may influence the frequency of the QCM sensor. This type of influence is caused by variation of the reflection conditions of the longitudinal wave between the QCM sensor and the walls of the detection cell. The frequency shifts, measured by varying θ, are related to the QCM sensor used. When a QCM sensor with a weak longitudinal wave is used, its resonant frequency is nearly independent of θ. But, if a QCM sensor with a strong longitudinal wave is employed, the immersion angle is a potential error source for the measurements performed on the QCM sensor. When the reflection conditions of the longitudinal wave are reduced, the influence of θ on the resonant frequency of the QCM sensor is negligible. The slope of the plot of frequency shifts (ΔF) versus (ρη)1/2, the square root of the product of solution density (ρ) and viscosity (η), may be influenced by θ in a single experiment for the QCM sensor with a strong longitudinal wave in low viscous liquids, which can however, be effectively weakened by using the averaged values of reduplicated experiments. In solutions with a large (ρη)1/2 region (0-55 wt% sucrose solution as an example, with ρ value from 1.00 to 1.26 g cm−3 and η value from 0.01 to 0.22 g cm−1 s−1, respectively), the slope of the plot of ΔF versus (ρη)1/2 is independent of θ even for the QCM sensor with a strong longitudinal wave in a single experiment. The influence of θ on the resonant frequency of the QCM sensor should be taken into consideration in its applications in liquid phase.  相似文献   

19.
Shen D  Kang Q  Wang YE  Hu Q  Du J 《Talanta》2008,76(4):803-808
In a traditional quartz crystal microbalance (QCM), an AT-cut (cut angle φ = 35.25° in yxl orientation) quartz wafer is employed because it has low frequency–temperature coefficients (dF/dT) at room temperature region. But when a QCM is in contact with a liquid phase, its frequency is also related to the properties of the liquid, which are temperature dependent. The value of dF/dT is about 20 Hz/°C for a 9 MHz AT-cut QCM with one side facing water. In this work, a group of QCMs in new cut angles were prepared. The influence of the cut angle on the frequency–temperature characteristic, response sensitivities to surface mass loading and viscodensity of liquid were investigated. An intrinsically temperature-compensated QCM sensor that possesses low dF/dT values in aqueous solution was reported. When a 9 MHz QCM with φ = 35.65° was contacted with water with one side, its dF/dT value is close to zero at ca. 25 °C and its averaged value of |dF/dT| is only 0.6 Hz/°C in the temperature range of 23–27 °C. The frequency responses to surface mass loading and viscodensity of liquid phase are very close among the QCMs with the cut angles in the range of 35.15–35.7°. The intrinsically temperature-compensated QCM was applied to investigate the alternate adsorption processes of cationic polyelectrolyte and silica nanoparticle.  相似文献   

20.
To modify gold electrode for immunosensor to construct an artificial cell membrane structure, water-soluble amphiphilic phospholipid polymer, poly[2-methacryloyloxyehtyl phosphorylcholine-co-n-butyl methacrylate-co-p-nitrophenyloxycarbonyl poly(ethylene glycol) methacrylate (PMBN)] was applied. The polymer had active ester groups for immobilization of biomolecules and it was converted partially to thiol groups for binding to gold substrates. The partially thiolated PMBN was adsorbed on a gold electrode of quartz crystal microbalance (QCM). Surface characterization of adsorbed PMBN layers was thoroughly investigated with reflectance anisotropy spectroscopy, ellipsometry spectroscopy, dynamic contact angle and X-ray photoelectron spectroscopy measurements. Among several PMBN, having different degree of thiolation, it was concluded that 21.5% thiolated PMBN layer had the most well-ordered phosphorylcholine groups in its outer surface. The proteins adsorption test revealed that the phosphorylcholine group on the outer side of PMBN layers, which was substituted their active ester groups by glycine, showed suppress the non-specific adsorption of proteins, such as bovine serum albumin and γ-globulin. Also, through antigen–antibody binding evaluation, the anti-C-reactive protein antibody immobilized on the PMBN surface worked well and it was confirmed that denaturation of the antibody on the PMBN layers was hardly occurred in spite of 60 days storage at 4 °C. The antibody conjugated phospholipid polymer layer with well-ordered phosphorylcholine group could be outstanding functional membrane for biomedical diagnostic devices without non-specific binding and reduction of immunologic activity of immobilized antibody.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏