首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We report a simple and efficient method for enriching the concentration of charged analytes within microfluidic channels. The method relies on exerting spatial control over the electrokinetic velocity of an analyte. Specifically, the electroosmotic (eo) velocity of the buffer solution in one region of the microfluidic system opposes the electrophoretic (ep) velocity of the analyte in the other region. This results in ep transport of DNA to the location where the ep and eo velocities are equal and opposite. Accumulation of the analyte occurs at this location. This enrichment method is conceptually distinct from field-amplification stacking, isotachophoresis, micelle sweeping, size exclusion, and other methods that have been previously reported. The method requires no complex microfabricated structures, no special manipulation of the solvent, and the enriched analyte remains in solution rather than being captured on a solid support. A concentration enrichment factor of 800 can be achieved for 20mer DNA in a fluidic channel having dimensions of 100 mum x 25 mum x 5 mm. The time required to achieve this level of enrichment is 300 s, and the enriched zone has a minimum width of 100 mum.  相似文献   

2.
Zhang Y  Timperman AT 《The Analyst》2003,128(6):537-542
A nanocapillary array was integrated into a microfluidic device and its ability to concentrate analytes was characterized. Through the application of an electric field across the channel, large molecules were concentrated in front of the nanocapillary array, and a concentrated analyte band was ejected from the channel by reversing the polarity of the electric field. The effects of nanocapillary diameter, analyte charge, analyte concentration, analyte plug length, and analyte relative mobility were investigated. Concentration factors up to 300-fold were measured for fluorescein. By concentrating anionic FITC-labeled peptides, it was demonstrated that the magnitude of the electrophoretic mobility did not have a measurable effect on the concentration factor. Therefore, multiple analytes can be concentrated in front of the same nanocapillary array without adjusting the conditions, provided the analytes have the same net charge. In the presence of an electric field, a charge trapping effect was observed; small anionic molecules can be concentrated in front of nanocapillary array with channel diameters which are orders of magnitude above the molecular weight cut-offs for hydrodynamically driven systems. The concentrating process was found to be very efficient for fluorescein, as no leakage through the nanocapillary array or sorption of fluorescein to the nanocapillary array was observed. Due to their flexibility and efficiency, it is anticipated that nanocapillary arrays will find increased utility in electrokinetically driven microfluidic systems.  相似文献   

3.
The performance of nanoporous hydrogel microplugs with varying surface charge density is described in concentrating charged analytes electrokinetically in a microfluidic device. A neutral hydrogel plug with a mean pore size smaller than the size of charged analytes acts as a simple size-exclusion membrane. The presence of fixed charges on the backbone of a nanoporous hydrogel creates ion-permselectivity which results in charge-selective transport through the hydrogel. This leads to the development of concentration polarization (CP) in the adjoining bulk electrolyte solutions under the influence of an applied electrical field. CP strongly affects the distribution of the local electrical field strength, in particular, in the vicinity of the hydrogel plug which can significantly reduce the concentration enrichment factors compared to the neutral hydrogel. A theoretical model and simulations are presented, together with experimental data, to explain the interplay of hydrogel or membrane cation-selectivity, electrical field-induced CP, and the distribution of the local electrical field strength with respect to concentration enrichment of negatively charged analytes at the cathodic membrane-solution interface.  相似文献   

4.
A microfluidic device is used to generate a complex gradient of diffusible molecules in a static solution. The gradient is precise and steady both in space and in time. This device, made from poly(dimethylsiloxane), consists of three layers. The molecules in reservoirs on the top layer diffuse through the flat middle layer of hydrogel and reach an equilibrium distribution. Microfluidic channels on the bottom layer that are in close contact with the hydrogel contain free solution that has concentration gradients based on the gradient in the gel. The gradient profile in the channel can be designed to have an arbitrary form (within the range of the existing gradient in the hydrogel) by controlling the local direction of the channel at each point.  相似文献   

5.
This paper reports rapid microfluidic electrokinetic concentration of deoxyribonucleic acid (DNA) with the Joule heating induced temperature gradient focusing (TGF) by using our proposed combined AC and DC electric field technique. A peak of 480-fold concentration enhancement of DNA sample is achieved within 40 s in a simple poly-dimethylsiloxane (PDMS) microfluidic channel of a sudden expansion in cross-section. Compared to a sole DC field, the introduction of an AC field can reduce DC field induced back-pressure and produce sufficient Joule heating effects, resulting in higher concentration enhancement. Within such microfluidic channel structure, negative charged DNA analytes can be concentrated at a location where the DNA electrophoretic motion is balanced with the bulk flow driven by DC electroosmosis under an appropriate temperature gradient field. A numerical model accounting for a combined AC and DC field and back-pressure driven flow effects is developed to describe the complex Joule heating induced TGF processes. The experimental observation of DNA concentration phenomena can be explained by the numerical model.  相似文献   

6.
Yang S  Undar A  Zahn JD 《Lab on a chip》2007,7(5):588-595
A microfluidic device for continuous biosensing based on analyte binding with cytometric beads is introduced. The operating principle of the continuous biosensing is based on a novel concept named the "particle cross over" mechanism in microfluidic channels. By carefully designing the microfluidic network the beads are able to "cross-over" from a carrier fluid stream into a recipient fluid stream without mixing of the two streams and analyte dilution. After crossing over into the recipient stream, bead processing such as analyte-bead binding may occur. The microfluidic device is composed of a bead solution inlet, an analyte solution inlet, two washing solution inlets, and a fluorescence detection window. To achieve continuous particle cross over in microfluidic channels, each microfluidic channel is precisely designed to allow the particle cross over to occur by conducting a series of studies including an analogous electrical circuit study to find optimal fluidic resistances, an analytical determination of device dimensions, and a numerical simulation to verify microflow structures within the microfluidic channels. The functionality of the device was experimentally demonstrated using a commercially available fluorescent biotinylated fluorescein isothiocyanate (FITC) dye and streptavidin coated 8 microm-diameter beads. After, demonstrating particle cross over and biotin-streptavidin binding, the fluorescence intensity of the 8 microm-diameter beads was measured at the detection window and linearly depends on the concentration of the analyte (biotinylated FITC) at the inlet. The detection limit of the device was a concentration of 50 ng ml(-1) of biotinylated FITC.  相似文献   

7.
We study theoretically the transport and kinetic processes underlying the operation of a biosensor (particularly the surface plasmon sensor "Biacore") used to study the surface binding kinetics of biomolecules in solution to immobilized receptors. Unlike previous studies, we concentrate mainly on the modeling of system-specific phenomena rather than on the influence of mass transport limitations on the intrinsic kinetic rate constants determined from binding data. In the first problem, the case of two-site binding where each receptor unit on the surface can accommodate two analyte molecules on two different sites is considered. One analyte molecule always binds first to a specific site. Subsequently, the second analyte molecule can bind to the adjacent unoccupied site. In the second problem, two different analytes compete for one binding site on the same surface receptor. Finally, the third problem considers the case of positive cooperativity among bound molecules in the hydrogel using a simple mean-field approach. The transport in both the flow channel and the hydrogel phases of the biosensor is taken into account in this case (with few exceptions, most previous studies assume a simpler model in which the hydrogel is treated as a planar surface with the receptors). We consider simultaneously diffusion and convection through the flow channel together with diffusion and cooperativity binding on the surface and in the hydrogel. In each case, typical results for the concentration contours of the free and bound molecules in the flow channel and hydrogel regions are presented together with the time-dependent association/dissociation curves and reaction rates. For binding site competition, the analysis predicts overshoot phenomena.  相似文献   

8.
To prepare spherical polymer hydrogels, we used a flow-focusing microfluidic channel device for mixing aqueous solutions of two water-soluble polymers. Continuous encapsulation of cells in the hydrogels was also examined. The polymers were bioinspired 2-methacryloyloxyethyl phosphorylcholine polymer bearing phenyl boronic acid groups (PMBV) and poly(vinyl alcohol) (PVA), which spontaneously form a hydrogel in aqueous medium via specific molecular complexation upon mixing, even when they were in cell culture medium. The microfluidic device was prepared with polydimethylsiloxan, and the surface of the channel was treated with fluoroalkyl compound to prevent sticking of the polymers on the surface. The microfluidic channel process could control the diameter of the spherical hydrogels in the range of 30-90 μm and generated highly monodispersed diameter spherical hydrogels. We found that the polymer distribution in the hydrogel was influenced by the PVA concentration and that the hydrogel could be dissociated by the addition of d-sorbitol to the suspension. The single cells could be encapsulated and remain viable in the hydrogels. The localized distribution of polymers in the hydrogel may provide an environment for modulating cell function. It is concluded that the spontaneous hydrogel formation between PMBV and PVA in the flow-focusing microfluidic channel device is applicable for continuous preparation of a spherical hydrogel-encapsulating living cell.  相似文献   

9.
Summary Basic considerations for analyte enrichment and recovery obtainable by electrodialysis as a sample treatment method are given. Equations are derived which describe the dependence of the concentration profiles of ionic compounds on the electric field strength in a set-up with stagnant donor and acceptor solutions. It is shown that analyte recovery increases when less ion-selective membranes are used in the electrodialysis cell. Computer models are used to estimate the analyte enrichment for a flowing donor (sample) and a stagnant acceptor phase. About 10-fold enrichment can be obtained in an electrodialytic sample treatment system within 20 min under maximum current conditions. A compromise has to be found between analyte recovery and the donor (sample) flow rate.  相似文献   

10.
The measurement of single poly(ethylene glycol) (PEG) molecules interacting with individual bilayer lipid membrane-bound ion channels is presented. Measurements were performed within a polymer microfluidic system including an open-well bilayer lipid membrane formation site, integrated Ag/AgCl reference electrodes for on-chip electrical measurements, and multiple microchannels for independent ion channel and analyte delivery. Details of chip fabrication, bilayer membrane formation, and alpha-hemolysin ion channel incorporation are discussed, and measurements of interactions between the membrane-bound ion channels and single PEG molecules are presented.  相似文献   

11.
Park SA  Jang E  Koh WG  Kim B 《Talanta》2011,84(3):1000-1003
We present the fabrication of a microdevice for the detection of phenol by combining microfluidic channels and poly(2-hydroxyethyl methacrylate) (PHEMA) hydrogel microparticles containing tyrosinase-quantum dot conjugates. PHEMA hydrogel microparticles containing conjugates of enzyme (tyrosinase) and quantum dot (QD) were prepared by dispersion photopolymerization and entrapped within a microfilter-incorporated reaction chamber in a microfluidic channel. The fluorescence change, due to the fluorescence quenching effect caused by the enzyme reaction between phenol and tyrosinase, was used to detect phenol. The fluorescence intensity of PHEMA hydrogel microparticles containing tyrosinase-QD conjugates at 585 nm decreased with phenol concentration. In conclusion, the microfluidic channels fabricated in this study entrapping PHEMA hydrogel microparticles containing enzyme-QD conjugates show the potential to be used as an analytic microdevice for the detection of phenol.  相似文献   

12.
A method to fabricate integrated single-walled carbon nanotube/microfluidic devices was developed. This simple process could be used to directly prepare nanotube thin film transistors within the microfluidic channel and to register SWNT devices with the microfludic channel without the need of an additional alignment step. The microfluidic device was designed to have several inlets that deliver multiple liquid flows to a single main channel. The location and width of each flow in the main channel could be controlled by the relative flow rates. This capability enabled us to study the effect of the location and the coverage area of the liquid flow that contained charged molecules on the conduction of the nanotube devices, providing important information on the sensing mechanism of carbon nanotube sensors. The results showed that in a sensor based on a nanotube thin film field effect transistor, the sensing signal came from target molecules absorbed on or around the nanotubes. The effect from adsorption on metal electrodes was weak.  相似文献   

13.
ZY Wu  CY Li  XL Guo  B Li  DW Zhang  Y Xu  F Fang 《Lab on a chip》2012,12(18):3408-3412
Due to Donnan exclusion, charged molecules are prohibited from passing through a channel of electrical double layer scale (nanometers), even though the molecules are smaller than the lowest dimension of the channel. To employ this effect for on-chip pre-concentration, an ion channel of nanometer scale has to be introduced. Here we introduced a simple method of generating a fracture (11-250 nm) directly on the commercially available open tubular fused silica capillary, and a chip comprised of the capillary with the nanofracture was prepared. A ring-disk model of the fracture was derived with which the fracture width can be easily characterized online without any damage to the chip, and the result was validated by a scanning electron microscope (SEM). The fractures can be used directly as a nanofluidic interface exhibiting an obvious ion concentration polarization effect with high current flux. On-chip electrokinetic stacking of SYBR Green I labeled λDNA inside the capillary was successfully demonstrated, and a concentration factor close to the amplification rate of the polymerase chain reaction (PCR) was achieved within 7 min. The chip is inexpensive and easy to prepare in common chemistry and biochemistry laboratories without limitations in expensive microfabrication facilities and sophisticated expertise. More applications of this interface could be found for enhancing the detectability of capillary based microfluidic analytical systems for the analysis of low concentrated charged species.  相似文献   

14.
A microfluidic traveling-wave electrophoresis (TWE) system is reported that uses a locally defined traveling electric field wave within a microfluidic channel to achieve band transport and separation. Low voltages, over a range of -0.5 to +0.5 V, are used to avoid electrolysis and other detrimental redox reactions while the short distance between electrodes, ~25 μm, provides high electric fields of ~200 V cm(-1). It is expected that the low voltage requirements will simplify the future development of smaller portable devices. The TWE device uses four interdigitated electrode arrays: one interdigitated electrode array pair is on the top of the microchannel and the other interdigitated electrode array pair is on the microchannel bottom. The top and bottom substrates are joined by a PDMS spacer that has a nominal height of 15 μm. A pinched injection scheme is used to define a narrow sample band within an injection cross either electrokinetically or hydrodynamically. Separation of two dyes, fluorescein and FLCA, with baseline resolution is achieved in less than 3 min and separation of two proteins, insulin and casein is demonstrated. Investigation of band broadening with fluorescein reveals that sample band widths equivalent to the diffusion limit can be achieved within the microfluidic channel, yielding highly efficient separations. This low level of band broadening can be achieved with capillary electrophoresis, but is not routinely observed in microchannel electrophoresis. Sample enrichment can be achieved very easily with TWE using a device with converging electric field waves controlled by two sets of independently controlled interdigitated electrodes arrays positioned serially along the microchannel. Sample enrichment of 40-fold is achieved without heterogeneous buffer/solvent systems, sorptive, or permselective materials. While there is much room for improvement in device fabrication, and many capabilities are yet to be demonstrated, it is anticipated that the capabilities and performance demonstrated herein will enable new lab-on-a-chip processes and systems.  相似文献   

15.
We introduce herein an efficient microfluidic approach for continuous transport and localized collection of nanoparticles via hybrid electrokinetics, which delicately combines linear and nonlinear electrokinetics driven by a composite DC-biased AC voltage signal. The proposed technique utilizes a simple geometrical structure, in which one or a series of metal strips serving as floating electrode (FE) are attached to the substrate surface and arranged in parallel between a pair of coplanar driving electrodes (DE) in a straight microchannel. On application of a DC-biased AC electric field across the channel, nanoparticles can be transported continuously by DC bulk electroosmotic flow, and then trapped selectively onto the metal strips due to AC-field induced-charge electrokinetic (ICEK) phenomenon, which behaves as counter-rotating micro-vortices around the ideally polarizable surfaces of FE. Finite-element simulation is carried out by coupling the dual-frequency electric field, flow field and sample mass transfer in sequence, for guiding a practical design of the microfluidic nanoparticle concentrator. With the optimal device geometry, the actual performance of the technique is investigated with respect to DC bias, AC voltage amplitude, and field frequency by using both latex nanospheres (∼500 nm) and BSA molecules (∼10 nm). Our experimental observation indicates nanoparticles are always enriched into a narrow bright band on the surface of each FE, and a horizontal concentration gradient even emerges in the presence of multiple metal strips, which therefore permits localized analyte enrichment. The proposed trapping method is supposed to guide an elaborate design of flexible electrokinetic frameworks embedding FE for continuous-flow analyte manipulation in modern microfluidic systems.  相似文献   

16.
In this article, we demonstrate a novel approach to implementing multiplex enzyme-linked immunosorbent assay (ELISA) in a single microfluidic channel by exploiting the slow diffusion of the soluble enzyme reaction product across the different assay segments. The functionality of the reported device is realized by creating an array of ELISA regions within a straight conduit that are selectively patterned with chosen antibodies/antigens via a flow-based method. The different analytes are then captured in their respective assay segments by incubating a 5-μL aliquot of sample in the analysis channel for an hour under flow conditions. Once the ELISA surfaces have been prepared and the enzyme substrate introduced into the analysis channel, it is observed that the concentration of the soluble enzyme reaction product (resorufin) at the center of each assay region grows linearly with time. Further, the rate of resorufin generation at these locations is found to be proportional to the concentration of the analyte being assayed in that segment provided that the ELISA reaction time in the system (τ R ) is kept much shorter than that required by the resorufin molecules to diffuse across an assay segment (τ D ). Under the operating condition τ R  << τ D , the reported device has been shown to have a 35% lower limit of detection for the target analyte concentration compared with that on a commercial microtiter plate using only a twentieth of the sample volume.  相似文献   

17.
A microfluidic channel is integrated with a tin oxide-based generic gas sensor on a PMMA (polymethyl methacrylate) substrate to fabricate a miniature gas analyzer. The analyte gas diffuses along the air-filled channel to affect the sensor installed in a microcavity positioned at the end of the channel. Analyte diffusion rates, experimentally estimated based on the temporal responses received from the sensor, are connected to the analyte's interactions with the channel walls as well as its diffusivity in air. The analyte-related information is extracted from the recorded responses and used for analyte recognition. A single PMMA channel of 80 μm × 3 mm × 50 mm dimensions facilitates the correct classification of single component contaminants each introduced in a wide concentration range in air. The device is also shown to identify 15 ppm of 2-butanol in air contaminated with 1500 ppm of 1-butanol. The gas analyzer fabricated based on this concept is durable, inexpensive, handheld and suitable for a variety of applications.  相似文献   

18.
This study reports the development of a microfluidic bead-based nucleic acid sensor for sensitive detection of circulating tumor cells in blood samples using multienzyme-nanoparticle amplification and quantum dot labels. In this method, the microbeads functionalized with the capture probes and modified electron rich proteins were arrayed within a microfluidic channel as sensing elements, and the gold nanoparticles (AuNPs) functionalized with the horseradish peroxidases (HRP) and DNA probes were used as labels. Hence, two signal amplification approaches are integrated for enhancing the detection sensitivity of circulating tumor cells. First, the large surface area of Au nanoparticle carrier allows several binding events of HRP on each nanosphere. Second, enhanced mass transport capability inherent from microfluidics leads to higher capture efficiency of targets because continuous flow within micro-channel delivers fresh analyte solution to the reaction site which maintains a high concentration gradient differential to enhance mass transport. Based on the dual signal amplification strategy, the developed microfluidic bead-based nucleic acid sensor could discriminate as low as 5 fM (signal-to-noise (S/N) 3) of synthesized carcinoembryonic antigen (CEA) gene fragments and showed a 1000-fold increase in detection limit compared to the off-chip test. In addition, using spiked colorectal cancer cell lines (HT29) in the blood as a model system, the detection limit of this chip-based approach was found to be as low as 1 HT29 in 1 mL blood sample. This microfluidic bead-based nucleic acid sensor is a promising platform for disease-related nucleic acid molecules at the lowest level at their earliest incidence.  相似文献   

19.
Yu H  Lu Y  Zhou YG  Wang FB  He FY  Xia XH 《Lab on a chip》2008,8(9):1496-1501
A facile and disposable microfluidic device for rapid protein concentration was fabricated by using a direct printing process. Two printed V-shaped microchannels in mirror image orientation were separated by a 100 mum wide toner gap. When a high electric field was applied across the two channels, nanofissures were formed by electric breakdown at the junction toner gap. This microfluidic device with nanofissures was used as a concentrator for protein. Negatively charged proteins were observed to concentrate at the anode side of the nanofissures upon application of an electric field across this junction. Using this device, about 10(3)-10(5)-fold protein concentration was achieved within 10 min. Systematic investigation showed that the concentration mechanism could be explained by the ion exclusion-enrichment effect of the nanofissures. In addition, the present microchip device integrated both functions of concentration and purification were confirmed. This simple on chip protein preconcentration and purification device could be a disposable sample preparation component in printed microfluidic systems used for practical biochemical assays.  相似文献   

20.
A freezing technique protocol was proposed for coupling microchip electrophoresis with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry(MALD1-TOF-MS).The microfluidic flow was frozen immediately after electrophoresis on microfluidic chip and the separated analyte molecules were kept in their zone pattern in the electrophoresis.Then,the frozen-chip was lyophilized and sent into TOF-MS instrument as a MALDI target,and the analyte molecules in the microfluidic channels were subjected to analysis by mass spectrometry.This approach could eliminate sample cross-contamination, providing a new interface for microchip electrophoresis and MALDI-MS.  相似文献   