首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel analytical method using liquid chromatography coupled to isotope ratio mass spectrometry (LC/IRMS) was developed for measuring the fractional synthesis rate (FSR) of glutathione (GSH) in neonates after infusion of [1-(13)C]-glycine as a tracer. After transformation of GSH into GSSG, its dimeric form, the intra-erythrocytic concentration and (13)C-isotopic enrichment of GSH were determined using 200 microL of blood. The results showed that, using LC/IRMS, the concentration (range of micromol/mL) was reliably measured using norvaline as internal standard with precision better than 0.1 micromol/mL. In addition, the (13)C-isotopic enrichment measured in the same run gave reliable values with excellent precision (with standard deviation (sd) lower than 0.3 per thousand) and accuracy (measured between 0 and 2 Atom % Excess (APE)). The inter-assay repeatability of delta(13)C of norvaline used as internal standard with in vivo samples was assessed at -26.07 +/- 0.28 per thousand with coefficient of variance (CV) at 1.1%. The FSR calculated either with GSH or GSSG showed similar results with slightly higher values for GSSG (41.6 +/- 4.7 and 46.5 +/- 4.4, respectively). The slightly lower FSR of GSH is probably due to interfering compounds in the biological matrix. Successfully used in a clinical study, this rapid and reliable method opens up a variety of kinetic studies with relatively low administration of tracer infusates, reducing the total cost of the study design. The small volume of blood needed enables studies even in extremely small subjects, such as premature infants, as reported in this study.  相似文献   

2.
The supercritical fluid chromatography coupled with mass spectrometry (SFC‐MS) method and liquid chromatography coupled with mass spectrometry (LC‐MS) method were developed for the separation and characterization of poly (ethylene oxide) methyl glucose sesquistearate (PEO‐Glu‐sesquistearate). The products of PEO‐Glu‐sesquistearate are composed of complex oligomers. The relationship between molecular structure of these oligomers and chromatographic retention behavior in both SFC and LC were discussed and compared. As compared with LC, hydrophobic moieties of compounds favor the fast elution in SFC. The different series can be better separated by LC, while the homologues compounds in same series can be better separated by SFC, and SFC‐MS provided more comprehensive structural information. Different series such as PEO‐distearate, PEO‐stearate, PEO, PEO‐Glu‐tetrastearate, PEO‐Glu‐tristearate, PEO‐Glu‐distearate, PEO‐Glu‐stearate, and PEO‐Glu were identified by MS/MS.  相似文献   

3.
液相色谱-同位素比质谱(LC-IRMS)是一种特征化合物同位素分析技术,该技术利用LC IsoLink接口设备实现液相色谱与同位素比质谱的联用,通过检测目标物质的稳定碳同位素比(δ13C),实现样品的产地来源与品质真实性鉴定。该文总结了IRMS与LC-IRMS技术的概况,以及过去20年LC-IRMS的发展历程;归纳整理了LC-IRMS在食品安全、生态与环境、生命科学及考古学等领域的应用情况;评述了LC-IRMS面临的技术局限、挑战及其未来的发展趋势。  相似文献   

4.
5.
A capillary gas chromatographic-mass spectrometric method for the simultaneous determination of stable isotopically labelled L-histidine (L-[3,3-2H2,1',3'-15N2]histidine, L-His-[M + 4]) and urocanic acid ([3-2H,1',3'-15N2]urocanic acid, UA-[M + 3]) in human plasma was developed using DL-[2,3,3,5'-2H4,2'-13C,1',3'-15N2]histidine (DL-His-[M + 7]) and [2,3,5'-2H3,2'-13C,1',3'-15N2]urocanic acid (UA-[M + 6]) as internal standards. L-Histidine and urocanic acid were derivatized to alpha N-(trifluoroacetyl)-imN-(ethoxycarbonyl)-L-histidine n-butyl ester and imN-(ethoxycarbonyl)urocanic acid n-butyl ester. Quantification was carried out by selected ion monitoring of the molecular ions of the respective derivatives of L-His-[M + 4], DL-His-[M + 7], UA-[M + 3] and UA-[M + 6]. The sensitivity, specificity, precision and accuracy of the method were demonstrated to be satisfactory for measuring plasma concentrations of L-His-[M + 4] and UA-[M + 3] following administration of trace amounts of L-His-[M + 4] to humans.  相似文献   

6.
Pulmonary surfactant is a complex mixture of phospholipids and proteins which lowers surface tension and maintains alveolar expansion at end expiration. Developmental and genetic disruption of pulmonary surfactant metabolism leads to respiratory distress in newborns. Stable isotope labeling of metabolic precursors of disaturated phospholipids, the most abundant and specific component of pulmonary surfactant, permits the measurement of the kinetics of surfactant metabolism in vivo. We measured [U-(13)C(6)]glucose incorporation into palmitic acid derived from disaturated surfactant phospholipids. A 24 h infusion of [U-(13)C(6)]glucose (140 mg kg(-1)) was administered to a premature infant who required mechanical ventilation for respiratory distress syndrome; tracheal aspirate samples were obtained at the start of the infusion and at regular intervals for the next 70 h. Each tracheal aspirate sample was incubated with osmium tetroxide to isolate disaturated surfactant phospholipids. Methyl esters of the fatty acids in the disaturated phospholipids were prepared and the enrichment of [(13)C]methyl palmitate was measured by gas chromatography/mass spectrometry (GC/MS) and gas chromatography/combination/isotope ratio mass spectrometry (GC/C/IRMS). Mass isotopomer distribution analysis (MIDA) was used to calculate the fractional synthetic rate (FSR) of palmitate synthesized from acetate. With both GC/MS and GC/C/IRMS, palmitate (13)C enrichment was first detected 12.3 h after the start of the tracer infusion. The enrichment increased in a linear fashion, reached a peak at 47 h and remained constant in the remainder of the samples. The FSR of palmitate from acetate was 5.2% per day. Stable isotope techniques and MIDA will provide insights into the kinetics of surfactant metabolism in newborns with respiratory dysfunction.  相似文献   

7.
李学民  贾光群  曹彦忠  张进杰  王蕾  孙会媛 《色谱》2013,31(12):1201-1205
采用液相色谱-同位素比质谱(LC-IRMS)技术建立了同时测定葡萄酒中甘油和乙醇δ13C值的分析方法。优化了葡萄酒中影响甘油和乙醇色谱分离的条件。方法的精密度和准确度分别为0.15‰~0.26‰和0.11‰~0.28‰。对40个葡萄酒样品进行了测定,甘油和乙醇的δ13 C值分别为-26.87‰~-32.96‰、-24.06‰~-28.29‰,两者具有较强的相关性(R=0.82)。该方法不需要复杂的样品预处理,在相同条件下同时测定甘油和乙醇的δ13C值,较传统方法简单、快速。  相似文献   

8.
Stable isotope analysis of cellulose is an increasingly important aspect of ecological and palaeoenvironmental research. Since these techniques are very costly, any methodological development which can provide simultaneous measurement of stable carbon and oxygen isotope ratios in cellulose deserves further exploration. A large number (3074) of tree-ring α-cellulose samples are used to compare the stable carbon isotope ratios (δ(13)C) produced by high-temperature (1400°C) pyrolysis/gas chromatography (GC)/isotope ratio mass spectrometry (IRMS) with those produced by combustion GC/IRMS. Although the two data sets are very strongly correlated, the pyrolysis results display reduced variance and are strongly biased towards the mean. The low carbon isotope ratios of tree-ring cellulose during the last century, reflecting anthropogenic disturbance of atmospheric carbon dioxide, are thus overestimated. The likely explanation is that a proportion of the oxygen atoms are bonding with residual carbon in the reaction chamber to form carbon monoxide. The 'pyrolysis adjustment', proposed here, is based on combusting a stratified sub-sample of the pyrolysis results, across the full range of carbon isotope ratios, and using the paired results to define a regression equation that can be used to adjust all the pyrolysis measurements. In this study, subsamples of 30 combustion measurements produced adjusted chronologies statistically indistinguishable from those produced by combusting every sample. This methodology allows simultaneous measurement of the stable isotopes of carbon and oxygen using high-temperature pyrolysis, reducing the amount of sample required and the analytical costs of measuring them separately.  相似文献   

9.
The individual determination of the apparent dissociation rate constant (kd,app) using high performance affinity chromatography (HPAC) is a tedious process requiring numerous separate tests and massive data fitting, unable to provide the apparent association rate constant (ka) and equilibrium binding constant (Ka). In this study, a HPAC with mass spectrometry detection (HPAC-MS/MS) was employed to determine the drug-cyclodextrin (CD) interaction kinetics with low sample loading quantity (<10 ng per injection for single compound) and high-throughput yield as twenty drugs determined in one injection. The kd,app measured by HPAC-MS/MS approach were 0.89 ± 0.07, 4.34 ± 0.01, 1.48 ± 0.01 and 7.77 ± 0.04 s−1 for ketoprofen, trimethoprim, indapamide and acetaminophen, with kd,app for acetaminophen consistent with that from the HPAC method with UV detector in our previous studies. For twenty drugs with diverse structures and chemical properties, good correlationship was found between kd,app measured by single compound analysis method and high-throughput HPAC-MS/MS approach, with the correlation coefficient of 0.987 and the significance F less than 0.001. Comprehensive quantification of ka,app, kd,app and Ka values was further performed based on the measurement of kd,app by peak profiling method and Ka by the peak fitting method. And the investigation of the drug-CD interaction kinetics under different conditions indicated that the column temperature and mobile phase composition significantly affected the determination of ka,app, kd,app and Ka while also dependent on the acidity and basicity of drugs. In summary, the high-throughput HPAC-MS/MS approach has been demonstrated high efficiency in determination of the drug-CD primary interaction kinetic parameter, especially, kd,app, being proven as a novel tool in screening the right CD for the solubilization of the right drug.  相似文献   

10.
Stable metal (e.g. Li, Mg, Ca, Fe, Cu, Zn, and Mo) and metalloid (B, Si, Ge) isotope ratio systems have emerged as geochemical tracers to fingerprint distinct physicochemical reactions. These systems are relevant to many Earth Science questions. The benefit of in situ microscale analysis using laser ablation (LA) over bulk sample analysis is to use the spatial context of different phases in the solid sample to disclose the processes that govern their chemical and isotopic compositions. However, there is a lack of in situ analytical routines to obtain a samples' stable isotope ratio together with its chemical composition. Here, we evaluate two novel analytical routines for the simultaneous determination of the chemical and Si stable isotope composition (δ30Si) on the micrometre scale in geological samples. In both routines, multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) is combined with femtosecond-LA, where stable isotope ratios are corrected for mass bias using standard-sample-bracketing with matrix-independent calibration. The first method is based on laser ablation split stream (LASS), where the laser aerosol is split and introduced simultaneously into both the MC-ICP-MS and a quadrupole ICP-MS. The second method is based on optical emission spectroscopy using direct observation of the MC-ICP-MS plasma (LA-MC-ICP-MS|OES). Both methods are evaluated using international geological reference materials. Accurate and precise Si isotope ratios were obtained with an uncertainty typically better than 0.23‰, 2SD, δ30Si. With both methods major element concentrations (e.g., Na, Al, Si, Mg, Ca) can be simultaneously determined. However, LASS-ICP-MS is superior over LA-MC-ICP-MS|OES, which is limited by its lower sensitivity. Moreover, LASS-ICP-MS offers trace element analysis down to the μg g−1-range for more than 28 elements due to lower limits of detection, and with typical uncertainties better than 15%. For in situ simultaneous stable isotope measurement and chemical composition analysis LASS-ICP-MS in combination with MC-ICP-MS is the method of choice.  相似文献   

11.
To achieve fast and accurate analysis of carbamazepine in surface water, we developed a novel porous membrane-protected micro-solid-phase extraction (μ-SPE) method, followed by liquid chromatography-isotope dilution tandem mass spectrometry (LC-IDMS/MS) analysis. The μ-SPE device (∼0.8 × 1 cm) was fabricated by heat-sealing edges of a polypropylene membrane sheet to devise a bag enclosing the sorbent. The analytes (both carbamazepine and isotope-labelled carbamazepine) were first extracted by μ-SPE device in the sample (10 mL) via agitation, then desorbed in an organic solvent (1 mL) via ultrasonication. Several parameters such as organic solvent for pre-conditioning of μ-SPE device, amount of sorbent, adsorption time, and desorption solvent and time were investigated to optimize the μ-SPE efficiency. The optimized method has limits of detection and quantitation estimated to be 0.5 ng L−1 and 1.6 ng L−1, respectively. Surface water samples spiked with different amounts of carbamazepine (close to 20, 500, and 1600 ng L−1, respectively) were analysed for the validation of method precision and accuracy. Good precision was obtained as demonstrated by relative standard deviations of 0.7% for the samples with concentrations of 500 and 1600 ng kg−1, and 5.8% for the sample with concentration of 20 ng kg−1. Good accuracy was also demonstrated by the relative recoveries in the range of 96.7%–103.5% for all samples with uncertainties of 1.1%–5.4%. Owing to the same chemical properties of carbamazepine and isotope-labelled carbamazepine, the isotope ratio in the μ-SPE procedure was accurately controlled. The use of μ-SPE coupled with IDMS analysis significantly facilitated the fast and accurate measurement of carbamazepine in surface water.  相似文献   

12.
采用同位素稀释电感耦合等离子体质谱(ID-ICP-MS)法测定了铅的含量,通过对茶叶标准物质(GBW-07605)中铅的测定,考察了方法的准确度和精密度,比较了同位素稀释法与普通外标定量法的测定结果。在5mLHNO3~0.5mLHF~1mLH2O2的消解体系中,ID-ICP-MS法测量茶叶中铅的回收率可达97.7%,相对标准偏差(RSD)小于1.2%。实验对市售的12种茶叶和10种蔬菜中Pb进行测定,铅含量符合相应国家标准的样品分别占总样品数的83%和90%。该法适合于植物样品中微量铅的测定。  相似文献   

13.
脑区神经递质的测定对于研究神经系统的作用机制具有重要意义。该研究建立了同位素内标稀释-超高效液相色谱-串联质谱同时测定双酚A暴露后大鼠海马体中5种神经递质含量的方法,包括谷氨酸、γ-氨基丁酸、乙酰胆碱、多巴胺以及5-羟色胺。选用2%(体积分数)乙酸水-甲醇(9:1,v/v)溶液配制标准样品及溶解样品,以Ultimate AQ-C18(150 mm×4.6 mm,3 μ m)为分离柱,0.1%(体积分数)甲酸水和甲醇为流动相,在28℃柱温下,梯度洗脱,所有化合物在3 min内出峰。添加维生素C能显著减少多巴胺和5-羟色胺在前处理以及样品储存过程中的氧化,极大地提高神经递质的稳定性,从而准确定量。该方法标准曲线线性关系良好,相关系数R2>0.998,检出限和定量限低,日内和日间精密度为0.39%~13.6%,加标回收率为92.9%~119%,实际进样残留低,已被成功地应用于新生期双酚A暴露后大鼠海马体神经递质含量的测定。  相似文献   

14.
Uranium analysis in fish, echinoderms and shellfish samples collected in the north part of the Adriatic Sea is presented. The aim of the work was to evaluate uranium concentrations in samples of this kind, and also to investigate possible contamination from depleted uranium (DU) in consequence of the war operations previously conducted in that area. DU contamination was checked by measuring the (235)U/(238)U isotope ratio. The samples were dissolved according to the EPA 3052 procedure, and the determinations were performed by inductively coupled plasma mass spectrometry (ICP-MS), optimized in order to perform isotope ratio measurements with good precision. The method was validated by evaluating the recovery from spiked samples; results in the range 93-107% were obtained. The isotope ratio measurement was evaluated in terms of accuracy and precision by analyzing the certified reference materials IAEA 326 and GBW 07305, and good agreement with the certified values was obtained here also. The concentration of uranium was higher in invertebrate samples than in fish (0.3-2 microg/g of U vs. 0.05-0.1 microg/g, respectively). The isotope ratio measurements for all the samples gave values very similar to the natural ratio, permitting exclusion of the presence of DU.  相似文献   

15.
A method for the simultaneous speciation of selenoproteins and selenometabolites in mouse plasma has been developed based on in series two-dimensional size exclusion and affinity high-performance liquid chromatography (2D/SE-AF-HPLC), using two columns of each type, and hyphenation to inductively coupled plasma-(quadrupole) mass spectrometry (ICP-QMS). The method allows the quantitative determination of selenoprotein P (SeP), extracellular glutathione peroxidase (eGPx), selenoalbumin (SeAlb), and selenometabolites in mouse plasma using species-unspecific isotope dilution (SUID). The 2D chromatographic separation is proposed to remove typical spectral interferences in plasma from chloride and bromide on 77Se (40Ar37Cl) and 82Se (81Br1H). In addition, the approach increases chromatographic resolution allowing the separation of eGPx from Se metabolites of low molecular mass. The method is robust, reliable, and fast with a typical chromatographic runtime less than 20 min. Precision in terms of relative standard deviation (n?=?5) is in the order of 4 %, and detection limits are in the range of 0.2 to 1.0 ng Se g?1. Method accuracy for determination of total protein bound to Se was assessed by analyzing human serum reference material (BCR-637) certified for total Se content, and latterly applied to mouse plasma (Mus musculus). In summary, a reliable speciation method for the analysis of eGPx, selenometabolites, SeP, and SeAlb in plasma/serum samples is proposed for the first time and is applicable to the evaluation of Se status in human in clinical studies and other mammals for environmental or toxicological assessment.
Figure
Simultaneous speciation of selenoproteins and selenometabolites in serum and plasma using 2D/SE-AF-HPLC-(SUID)-ICP-ORS-qMS  相似文献   

16.
This paper describes the development of a guantitative method for direct and simultaneous determination of three frequently encountered surfactants, amphoteric (cocoamphoacetate, CAA), anionic (sodium laureth sulfate, SLES), and nonionic (alcohol ethoxylate, AE) using a reversed-phase C18 HPLC coupled with an ESI ion-trap mass spectrometer (MS). Chemical composition, ionization characteristics and fragmentation pathways of the surfactants are presented. Positive ESI was effective for all three surfactants in agueous methanol buffered with ammonium acetate. The method enables rapid determinations in small sample volumes containing inorganic salts (up to 3.5 g L(-1)) and multiple classes of surfactants with high specificity by applying surfactant specific tandem mass spectrometric strategies. It has dynamic linear ranges of 2-60, 1.5-40, 0.8-56 mg L(-1) with R2 egual or greater than 0.999, 0.98 and 0.999 (10 microL injection) for CAA, SLES, and AE, respectively.  相似文献   

17.
Liquid chromatography (LC) and ion mobility (IM) separation have been coupled with mass spectrometry (MS) and tandem mass spectrometry (MS2) to characterize a commercially important nonionic surfactant, polysorbate 85. The constituents of this amphiphilic blend contained a sorbitan or isosorbide core that was chain extended with poly(ethylene oxide) (PEO) and partially esterified at the PEO termini with oleic acid or, to a lesser extent, other fatty acids. Using interactive LC in reverse-phase mode, the oligomers of the surfactant were separated according to their hydrophobicity/hydrophilicity balance. On the other hand, IM spectrometry dispersed the surfactant oligomers by their charge and collision cross section (i.e. size/shape). With either separation method, an increased number of fatty ester groups and/or lack of the polar sorbitan (or isosorbide) core led to higher retention/drift times, enabling the separation of isobaric species or species with superimposed isotope patterns, so that their ester content could be conclusively identified by MS2. LC–MS and IM–MS permitted the detection of several byproducts besides the major PEO-sorbitan oleate oligomers. LC–MS provides the separation resolution needed for quantitative determination of the degree of esterification. IM–MS, which minimizes analysis time and solvent use, is ideally suitable for a fast, qualitative survey of samples differing in their minor constituents or impurities.  相似文献   

18.
On-line gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS) is commonly used to measure isotopic ratios at natural abundance as well as for tracer studies in nutritional and medical research. However, high-precision (13)C isotopic enrichment can also be measured by liquid chromatography-isotope ratio mass spectrometry (LC-IRMS). Indeed, LC-IRMS can be used, as shown by the new method reported here, to obtain a baseline separation and to measure (13)C isotopic enrichment of underivatised amino acids (Asp, Thr-Ser, Glu, Pro, Gly, Ala, Cys and Val). In case of Val, at natural abundance, the SD(delta(13)C) reported with this method was found to be below 1 per thousand . Another key feature of the new LC-IRMS method reported in this paper is the comparison of the LC-IRMS approach with the conventional GC-C-IRMS determination. To perform this comparative study, isotopic enrichments were measured from underivatised Val and its N(O, S)-ethoxycarbonyl ethyl ester derivative. Between 0.0 and 1.0 molar percent excess (MPE) (delta(13)C= -12.3 to 150.8 per thousand), the calculated root-mean-square (rms) of SD was 0.38 and 0.46 per thousand and the calculated rms of accuracy was 0.023 and 0.005 MPE, respectively, for GC-C-IRMS and LC-IRMS. Both systems measured accurately low isotopic enrichments (0.002 atom percent excess (APE)) with an SD (APE) of 0.0004. To correlate the relative (delta(13)C) and absolute (atom%, APE and MPE) isotopic enrichment of Val measured by the GC-C-IRMS and LC-IRMS devices, mathematical equations showing the slope and intercept of the curves were established and validated with experimental data between 0.0 to 2.3 MPE. Finally, both GC-C-IRMS and LC-IRMS instruments were also used to assess isotopic enrichment of protein-bound (13)C-Val in tibial epiphysis in a tracer study performed in rats. Isotopic enrichments measured by LC-IRMS and GC-C-IRMS were not statistically different (p>0.05). The results of this work indicate that the LC-IRMS was successful for high-precision (13)C isotopic measurements in tracer studies giving (13)C isotopic enrichment similar to the GC-C-IRMS but without the step of GC derivatisation. Therefore, for clinical studies requiring high-precision isotopic measurement, the LC-IRMS is the method of choice to measure the isotopic ratio.  相似文献   

19.
A simple, sensitive and reliable analytical method was developed for the simultaneous determination of clenbuterol (CLB), salbutamol (SAL) and ractopamine (RAC) in milk by ultra high performance liquid chromatography–positive electrospray ionization tandem mass spectrometry (UHPLC–ESI-MS/MS) with isotope dilution. Samples were directly purified through HLB cartridge. Then the eluate was dried under nitrogen and residues were redissolved in mobile phase. Samples were analyzed by LC–MS/MS on an Acquity UPLC® BEH C18 column with gradient elution. The samples were quantified using clenbuterol-D9, salbutamol-D3 and ractopamine-D6 as internal standards. The proposed method was validated according to the European Commission Decision 2002/657/EC determining specificity, decision limit (CCα), detection capability (CCβ), recovery, precision, linearity, robustness and stability. CCα values were 0.054, 0.006 and 0.008 μg/kg for CLB, SAL and RAC, respectively. CCβ values were 0.058, 0.007 and 0.009 μg/kg for CLB, SAL and RAC, respectively. The mean recoveries, repeatability (expressed as coefficient of variation, CVr), and reproducibility (CVR) varied from 95.8 to 106.2%, from 3.60 to 6.44% (CVr), and from 4.77 to 7.53% (CVR), respectively. The method is demonstrated to be suitable for the determination of clenbuterol, salbutamol and ractopamine in milk. The total time required for the analysis of one sample, including sample preparation, was about 45 min.  相似文献   

20.
Chloropicrin (trichloronitromethane) is a widely used soil fumigant and an old chemical warfare agent. The metabolism of chloropicrin is not well known in mammals but nitromethane has been shown to be one of its main metabolites. Here, a fast and simple headspace gas chromatography with mass spectrometry method was applied for the measurement of nitromethane from aqueous samples. The analytical method was validated using stable isotope labeled internal standard and a small sample volume of 260 μL. No conventional sample preparation steps were needed. The method was accurate (relative standard deviations ≤1.5%) and linear (R2 = 0.9996) within the concentration range of 0.1?6.0 μg/mL. This method was used to measure nitromethane in in vitro incubations with human and pig liver cell fractions containing enzymes for xenobiotic metabolism, exposed to chloropicrin. The results indicate that the presence of glutathione is necessary for the formation of nitromethane from chloropicrin. Also, nitromethane was formed mostly in liver cytosol fractions, but not in microsomal fractions after the incubation with chloropicrin. Our results suggest that although nitromethane is not the unequivocal biomarker of chloropicrin exposure, this method could be applied for screening the elevated levels in humans after chloropicrin exposure.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号