 共查询到20条相似文献,搜索用时 15 毫秒
1.
Abstract

Breath tests using 13C-labelled substrates require the measurement of 13CO2/12CO2 ratio in breath gas samples. Next to isotope ratio mass spectrometry (IRMS), which is very sensitive but also complex and expensive, alternatively isotope selective nondispersive infrared spectrometry (NDIRS) can be used to determine the 13CO2/12CO2 ratio in expired breath. In this study we compared NDIRS- with IRMS-results to investigate whether the less expensive and very simply to operate NDIRS works as reliable as IRMS. For this purpose we applicated 1-13C-Phenylalanine to patients with advanced liver cirrhosis and healthy volunteers and took duplicated breath samples for IRMS and NDIRS at selected time points. Our data show a good correlation between these two methods for a small number of samples as required for simple breath tests. Longer series, where repeated measurements are required on the NDIRS instrument lead to a decreasing correlation. This indicates the superiority of IRMS concerning 13CO2-kinetics over longer time periods.  相似文献   

2.
A newly developed isotope selective nondispersive infrared (NDIR) spectrometer for the measurement of 13CO2 and 12CO2 concentrations in breath samples was applied as a low cost and very simple to operate alternative to isotope ratio mass spectrometry (IRMS). We used this device for several biomedical applications ([13C]urea breath test, [13C]leucine metabolism, [13C]methacetin catabolism of rats) and found that the results agree very well with IRMS.  相似文献   

3.
We present a nondispersive infrared spectrometer (NDIRS) for the measurement of the 13CO2/12CO2-ratio in breath samples. A commercial NDIR spectrometer for CO2 concentration measurements in industrial process control was modified using two separate optical channels for the 13CO2 and 12CO2 detection. Cross interference due to overlapping absorption lines of both isotopic gases was successfully eliminated. The sensitivity of this device is ± 0.4‰ of the 13CO2/12CO2-ratio in a range of 2.5 to 5% of total CO2. This is sufficient for biomedical applications. Our spectrometer is small in size, cheap and simple to operate and thus a true alternative to isotope ratio mass spectrometers (IRMS). Several biomedical applications with breath samples were demonstrated and were compared in very good agreement with IRMS.  相似文献   

4.
Continuous analysis of the (13)C/(12)C ratio of atmospheric CO(2) (delta(13)C-CO(2)) is a powerful tool to quantify CO(2) flux strengths of the two major ecosystem processes assimilation and respiration. Traditional laboratory techniques such as isotope ratio mass spectrometry (IRMS) in combination with flask sampling are subject to technical limitations that do not allow to fully characterising variations of atmospheric delta(13)C-CO(2) at all relevant timescales. In our study, we demonstrate the strength of Fourier transform infrared (FTIR) spectroscopy in combination with a PLS-based calibration strategy for online analysis of delta(13)C-CO(2) in ambient air. The ability of the instrument to measure delta(13)C-CO(2) was tested on a grassland field-site and compared with standard laboratory-based IRMS measurements made on field-collected flask samples. Both methods were in excellent agreement, with an average difference of 0.4 per thousand (n=81). Simultaneously, other important trace gases such as CO, N(2)O and CH(4) were analysed by FTIR spectroscopy.  相似文献   

5.
The use of isotopic carbon dioxide lasers for determination of carbon (and oxygen) isotope ratios was first demonstrated in 1994. Since then a commercial device called LARA, has been manufactured and used for Helicobacter pylori breath tests using (13)C-labelled urea. The major advantages of the optogalvanic effect compared with other infrared absorption isotope ratio measurement techniques are its lack of optical background and its high sensitivity resulting from a signal gain proportional to laser power. Continuous normalisation using two cells, a standard and sample, lead to high accuracy as well as precision. Recent advances in continuous flow measurement of (13)C/(12)C ratios of CO(2) in air and extensions of the technique to (14)C, which can be analysed as a stable isotope, are described.  相似文献   

6.
The increasing application of 13C-labelled urea in medicine requires simple and reasonable methods for measuring highly enriched C in urea. The combination: ultimate organic analysis--mass spectrometry so far prescribed is complicated and expensive. For medical diagnosis, however, isotope selective nondispersive infrared spectrometers (NDIRS) have been available for many years. One of these tools is FANci2 which is very reasonable and easily to be operated. By means of such devices also urea highly enriched in 13C can be analysed, provided that the samples are first diluted with a defined amount of urea of natural isotopic composition and then transformed into carbon dioxide by means of urease. The relative abundance of 13C in this carbon dioxide, measured by nondispersive infrared spectrometry, is then a measure of the 13C abundance in the initial urea sample. Comparison of results of such measurements with those attained by mass spectrometry proves that this procedure is feasible and yields precis results.  相似文献   

7.
This paper was presented in poster form at the 17th International Congress of Nutrition, August 27-31, Vienna, Austria (Annals of Nutrition & Metabolism 2001; 45(Suppl.1):349). Some of the data were also presented in poster form at the British Society of Gastroenterology Meeting, March 18-21, Glasgow, UK (Gut 2001; 48(Suppl.1):A91). The 13C-mixed triacylglycerol (MTG) breath test is used to measure intraluminal fat digestion. In normal digestion, 20-40% of the ingested 13C label is recovered in breath CO2. We aimed to identify the proportions of ingested label excreted in stool, as well as breath following ingestion of 13C-MTG by children with impaired exocrine pancreatic function and healthy controls. 13C enrichment of breath samples was measured by continuous flow isotope ratio mass spectrometry (IRMS) and cumulative percent dose recovered (cPDR) in 10 h was calculated. Total 13C of a faecal fat extract from each stool was measured by elemental analyser-IRMS, and 13C enrichment and concentration of the TBDMS derivative of octanoic acid was measured by GC/MS after hydrolysis of the fat extract. Stool 5-day cPDR was calculated. Mean breath cPDR was 35%. Mean cPDR in stool by combustion-IRMS and GC/ MS, respectively, was 0.8% and 1.0%. Therefore, the remaining 64% of the 13C label must remain in the body and variability in breath cPDR is due to postabsorptive rather than predigestive factors.  相似文献   

8.
Abstract

The increasing application of 13C-labelled urea in medicine requires simple and reasonable methods for measuring highly enriched 13C in urea. The combination: ultimate organic analysis—mass spectrometry so far prescribed is complicated and expensive. For medical diagnosis, however, isotope selective nondispersive infrared spectrometers (NDIRS) have been available for many years. One of these tools is FANci2 which is very reasonable and easily to be operated. By means of such devices also urea highly enriched in 13C can be analysed, provided that the samples are first diluted with a defined amount of urea of natural isotopic composition and then transformed into carbon dioxide by means of urease. The relative abundance of 13C in this carbon dioxide, measured by nondispersive infrared spectrometry, is then a measure of the 13C abundance in the initial urea sample. Comparison of results of such measurements with those attained by mass spectrometry proves that this procedure is feasible and yields precise results.  相似文献   

9.
The use of isotopic carbon dioxide lasers for determination of carbon (and oxygen) isotope ratios was first demonstrated in 1994. Since then a commercial device called LARA?, has been manufactured and used for Helicobacter pylori breath tests using 13C-labelled urea. The major advantages of the optogalvanic effect compared with other infrared absorption isotope ratio measurement techniques are its lack of optical background and its high sensitivity resulting from a signal gain proportional to laser power. Continuous normalisation using two cells, a standard and sample, lead to high accuracy as well as precision. Recent advances in continuous flow measurement of 13C/12C ratios of CO2 in air and extensions of the technique to 14C, which can be analysed as a stable isotope, are described.  相似文献   

10.
Abstract

This paper was presented in poster form at the 17th International Congress of Nutrition, August 27-31, Vienna. Austria (Annals of Nutrition & Metabolism 2001; 45(Suppl.1):349). Some of the data were also presented in poster form at the British Society of Gastroenterology Meeting, March 18-21, Glasgow, UK (Gut 2001; 48(Suppl.1):A91).

The 13C-mixed triacylglycerol (MTG) breath test is used to measure intraluminal fat digestion. In normal digestion. 20–40% of the ingested 13C label is recovered in breath CO2. We aimed to identify the proportions of ingested label excreted in stool, as well as breath following ingestion of 13C-MTG by children with impaired exocrine pancreatic function and healthy controls. 13C enrichment of breath samples was measured by continuous flow isotope ratio mass spectrometry (IRMS) and cumulative percent dose recovered (cPDR) in 10 h was calculated. Total 13C of a faecal fat extract from each stool was measured by elemental analyser-IRMS, and 13C enrichment and concentration of the TBDMS derivative of octanoic acid was measured by GC/MS after hydrolysis of the fat extract. Stool 5-day cPDR was calculated. Mean breath cPDR was 35%. Mean cPDR in stool by combustion-IRMS and GC/ MS, respectively, was 0.8% and 1.0%. Therefore, the remaining 64% of the 13C label must remain in the body and variability in breath cPDR is due to postabsorptive rather than predigestive factors.  相似文献   

11.
A sufficiently stable rate of 13CO2 exhalation is necessary when the diagnostic 13CO2 breath tests are performed in healthy subjects and patients. The aim of the research was to define prerequisite conditions for kinetic breath tests in order to ensure a stable 13CO2 background. A 3-part protocol was developed. Part I: a study of the one-day variation of 13CO2 abundance in expired CO2 confirmed that shifts of the basal 13C abundance in breath are inherent in nature. Part II: a study of the variations of 13C enrichment after the ingestion of different meals and beverages showed that ingestion of food items containing C4 plant sugars, such as maize, induces a significant increase in isotopic abundance. Part III: a new test breakfast containing rice grain cereal, milk and orange juice was tested. This test meal induces no significant change on the basal 13CO2 abundance in healthy subjects. This new finding allows to avoid the fasting period normally required prior to a breath test which is sometimes difficult for children and pregnant women.  相似文献   

12.
CO2 stable carbon isotopes are very attractive in environmental research to investigate both natural and anthropogenic carbon sources. Laser-based CO2 carbon isotope analysis provides continuous measurement at high temporal resolution and is a promising alternative to isotope ratio mass spectrometry (IRMS). We performed a thorough assessment of a commercially available CO2 Carbon Isotope Analyser (CCIA DLT-100, Los Gatos Research) that allows in situ measurement of δ 13C in CO2. Using a set of reference gases of known CO2 concentration and carbon isotopic composition, we evaluated the precision, long-term stability, temperature sensitivity and concentration dependence of the analyser. Despite good precision calculated from Allan variance (5.0 ppm for CO2 concentration, and 0.05 ‰ for δ 13C at 60 s averaging), real performances are altered by two main sources of error: temperature sensitivity and dependence of δ 13C on CO2 concentration. Data processing is required to correct for these errors. Following application of these corrections, we achieve an accuracy of 8.7 ppm for CO2 concentration and 1.3 ‰ for δ 13C, which is worse compared to mass spectrometry performance, but still allowing field applications. With this portable analyser we measured CO2 flux degassed from rock in an underground tunnel. The obtained carbon isotopic composition agrees with IRMS measurement, and can be used to identify the carbon source.  相似文献   

13.
Continuous records of isotope behaviour in the environment are invaluable to understanding mass and energy fluxes. Although techniques such as isotope ratio mass spectrometry provide high precision data, they are not well suited to the analysis of a large number of samples and are currently restricted to use in the laboratory. Fourier transform infrared spectrometers are relatively cheap and sufficiently portable and robust to be taken into the field to collect continuous records of gas-phase isotope behaviour. Several examples of the application of this technique will be presented. One data set provides half-hourly determinations of vertical profiles of D/H in water vapour above agricultural fields over a 3-week period; the same infrared spectra can also be used to determine 13C/12C in CO2. The technique has also been applied to the study of CO2 in ambient air and in a limestone cave system. Some of the features and complications associated with the method will also be considered.  相似文献   

14.
A new technique for the generation of multilayered molecular nanoparticles is presented. Core-shell composite nanoparticles of CO(2) with varied composition have been investigated by Fourier-transform infrared spectroscopy over 600 s at 78 K. The isotopically different zones of the particles turned out to have completely different spectra in the nu(3) region: a tub structure (mantle) and a head-and-shoulders structure (core). From the aggregation behavior of both components the particle formation time was found to be 0.1 s. Low-temperature self-diffusion of airborne molecular nanoparticles has been monitored for the first time. The self-diffusion coefficient for (12)CO(2)/(13)CO2 nanocomposites at 78 K was determined from the time evolution of the nu(1) + nu(3) combination band to about 7 x 10(-20) m(2)/s. The work represents a major advance toward nanoengineering of molecular nanoparticles at low temperatures.  相似文献   

15.
Customary 13CO2 breath tests--and also 15N urine tests--always start with an oral administration of a test substrate. The test person swallows a stable isotope labelled diagnostic agent. This technique has been used to study several pathophysiological changes in gastrointestinal organs. However, to study pathophysiological changes of the bronchial and lung epithelium, the inhalative administration of a stable isotope labelled agent appeared more suitable to us. [1-13C]Hexadecanol and [1-13C]glucose were chosen. Inhaled [1-13C]hexadecanol did not yield 13CO2 in the exhaled air, but [1-13C]glucose did. To study the practicability of the [1-13C]glucose method and the reproducibility of the results, 18 inhalation tests were performed with healthy subjects. In 6 self-tests, the optimum inhalative dose of [13C]glucose was determined to be 205 mg. Using the APS aerosol provocation system with the nebulizer 'Medic Aid' (Erich Jaeger Würzburg), a 25% aqueous solution was inhaled. Then, breath samples were collected at 15 min. intervals and analysed for 13CO2. 75-120 min after the end of inhalation a well-reproducible maximum delta13C value of 6%o over baseline (DOB) was detected for 12 healthy probands. Speculating that the pulmonary resorption of the [13C]glucose is the rate-limiting step of elimination, decompensations in the epithelium ought to be reflected in changed [1-13C]glucose resorption rates and changed 13CO2 output. Therefore, we speculate that the inhalation of suitable 13C-labelled substrates will pave the way for a new group of 13CO2 breath tests aiding investigations of specific pathophysiological changes in the pulmonary tract, such as inflammations of certain sections and decompensations of cell functions.  相似文献   

16.
The isotope ratio analysis of body water often involves large sample numbers and lengthy sample processing. Here we demonstrate the ability of isotope ratio infrared spectroscopy (IRIS) to rapidly and accurately analyse the isotope ratios of water in urine. We analysed water extracted from human urine using traditional isotope ratio mass spectrometry (IRMS) and compared those values with IRIS-analysed extracted water and un-extracted urine. Regression analyses for δ2H and δ1?O values between (1) extracted water analysed via IRMS and IRIS and (2) urine and extracted water analysed via IRIS were significant (R2=0.99). These results indicate that cryogenic distillation of urine was not required for an accurate estimate of the isotopic composition of urine when using IRIS.  相似文献   

17.
Near-infrared laser spectroscopy is used to measure the 13C/12C isotope abundance ratio in gas phase carbon dioxide. The spectrometer, developed expressly for field applications, is based on a 2 μm distributed feedback diode laser in combination with sensitive wavelength modulation detection. It is characterized by a simplified optical layout, in which a single detector and associated electronics are used to probe absorptions of a pair of 13CO2 and 12CO2 lines, simultaneously in a sample, as well as a reference gas. For a careful investigation of the achievable precision and accuracy levels, we carried out a variety of laboratory tests on CO2 samples with different isotopic compositions, calibrated with respect to the international standard material by means of isotope ratio mass spectrometry. The 1-σ accuracy of the 13CO2/12CO2 determinations, reported in the so-called δ notation, is about 0.5‰ (including both statistical and systematic errors), for δ-values in the range from -30‰ to +20‰. We show that the major source of systematic errors is a consequence of the non-linearity of the Lambert–Beer absorption law, and can be corrected for to a very high degree of accuracy. PACS 42.62.Fi; 42.55.Px; 33.20.Ea  相似文献   

18.
The isotope ratio analysis of body water often involves large sample numbers and lengthy sample processing. Here we demonstrate the ability of isotope ratio infrared spectroscopy (IRIS) to rapidly and accurately analyse the isotope ratios of water in urine. We analysed water extracted from human urine using traditional isotope ratio mass spectrometry (IRMS) and compared those values with IRIS-analysed extracted water and un-extracted urine. Regression analyses for δ2H and δ18O values between (1) extracted water analysed via IRMS and IRIS and (2) urine and extracted water analysed via IRIS were significant (R 2=0.99). These results indicate that cryogenic distillation of urine was not required for an accurate estimate of the isotopic composition of urine when using IRIS.  相似文献   

19.
The aim of this study is to determine if age is a factor influencing the results of a [(13)C]methacetin breath test ((13)C-MBT). Two groups of healthy volunteers, each comprising six men and six women, but differing in average age (Y=young, 25.1+/-0.6 years, MA=middle-aged;, 46.0+/-2.1 years) orally took 75 mg [(13)C]methacetin. Samples of expiratory air for (13)CO(2) measurement were collected up to 48 h after intake of the substrate. A maximum momentary (13)CO(2) breath exhalation of 37.0+/-2.6%dose/h was observed at 18 min (median, range: 9-30 min) in the young subjects and of 38.4+/-2.5%dose/h at 18 min (median, range: 12-30 min) in the middle-age volunteers. The cumulative (13)C elimination in expiratory air was statistically significantly higher in the MA compared with the Y group as from 75 min up to 180 min, indicating a greater microsomal metabolic efficiency of the liver in the middle-aged healthy subjects. Gender, use of hormonal contraception, cigarette smoking, or body mass index did not modify the age-related effect on the cumulative (13)C elimination in breath air. The study results imply a necessity of composing control groups well matched with regard to the age structure for a proper interpretation of clinical (13)C-MBT results.  相似文献   

20.
Cerebral blood flow (CBF) and oxygenation changes following both a simple breath holding test (BHT) and a CO(2) challenge can be detected with functional magnetic resonance imaging techniques. The BHT has the advantage of not requiring a source of CO(2) and acetazolamide and therefore it can easily be performed during a routine MR examination. In this study we compared global hemodynamic changes induced by breath holding and CO(2) inhalation with blood oxygenation level dependent (BOLD) and CBF sensitized fMRI techniques. During each vascular challenge BOLD and CBF signals were determined simultaneously with a combined BOLD and flow-sensitive alternating inversion recovery (FAIR) pulse sequence. There was a good correlation between the global BOLD signal intensity changes during breath holding and CO(2) inhalation supporting the notion that the BHT is equivalent to CO(2) inhalation in evaluating the hemodynamic reserve capacity with BOLD fMRI. In contrast, there was no correlation between relative CBF changes during both vascular challenges, which was probably due to the reduced temporal resolution of the combined BOLD and FAIR pulse sequence.  相似文献   