1.
In this paper, a series of C-terminal modified analogs of endomorphin-2 is investigated using ESI-FT-ICR-MS. Some b, y″, a, and internal ions are found in the CID spectra and slight mass differ- ences between the calculated and observed results are obtained. Moreover, if the C-terminal modified group is t-butyloxy, it can lose butene through McLafferty rearrangement. FT-ICR MS shows its power in peptide sequencing successfully helping us obtain the structure of peptide analogs.  相似文献   

2.
The conjugates of phosphoamino acids with 3'-azido-3'-deoxythymidine were synthesized and their structures were determined by various spectral methods. In positive and negative ion electrospray mass spectrometry (ESI-MS), the fragmentation pathways were investigated in conjunction with tandem mass spectrometry (MS/MS). The results showed that there were very different characteristic fragment ions in the positive ion MS/MS spectra and the negative ion MS/MS spectra.  相似文献   

3.
4.
董振霖  杨春光  徐天  代弟  高鹭  杨璐  王秋艳 《色谱》2022,40(1):28-40
芬太尼类物质品种繁多,自我国整类列管后,整类检测是该领域的重点和难点。该文详细研究了29种化合物的二级质谱碎片离子碎裂机理,总结出芬太尼类物质的碎裂规律和特点,为芬太尼物质的整类筛查检测提供参考。建立了分析29种芬太尼类物质的一级和二级质谱库的定性方法,建立了液相色谱-四极杆/飞行时间质谱(LC-QTOF-MS)检测29种芬太尼类物质的定量方法。药品和白色粉末类、蛋白质和乳饮料类样品经乙腈提取,含糖固体或粉末类、饮用水类、果蔬饮料类、保健饮料类、茶饮料类、酒类样品经10%乙腈水溶液提取,提取液经涡旋、离心和过膜后,采用Kinetex C18色谱柱(100 mm×2.1 mm,2.6μm)分离,以乙腈和0.08%甲酸水溶液为流动相进行梯度洗脱,采用四极杆/飞行时间质谱,在正离子模式下,外标法定量检测。结果表明,29种芬太尼类物质在1~20μg/L范围内线性关系良好,相关系数均大于0.995,检出限(LOQ)均为0.01 mg/kg,定量限(LOQ)均为0.05 mg/kg,在降糖药、露露、葡萄糖粉、珍露保健饮料和巧克力样品中3个加标水平平均回收率为85.2%~112.9%,相对标准偏差(RSD)为1.9%~19.8%(n=6)。该方法操作简单,耗时短,灵敏度高,稳定性好,检测品种覆盖范围广,适用于药品类、含糖固体或粉末类、饮料类、饮用水类和酒类等样品中29芬太尼类物质的定性和定量检测。  相似文献   

5.
Thermal decomposition (TD) of proteins is being investigated as a rapid digestion step for bottom‐up proteomics. Mass spectrometry (MS) analyses of the TD products of simple peptides and intact proteins have revealed several nonvolatile products at masses lower than the precursor biomolecule (M). In addition to products stemming from site‐specific cleavages, many signals are also observed at a corresponding M‐18, most likely because of dehydration (M‐H2O) during the heating process. Understanding the structural nature of the water loss product is important in establishing the utility of their tandem mass spectra (collision‐induced dissociation) in determining the precursor ion amino acid sequence in a bottom‐up proteomic workflow. Dehydration of a peptide can take place from a variety of sources including side chain groups, C‐terminus, and/or intramolecular cyclization (C to N‐terminus cyclization). In this work, liquid chromatography‐tandem MS (LC‐MS/MS) and a series of standard peptides (angiotensin II, DRVYIHPF and its cyclic analog) are implemented to decipher the structure of the TD dehydration product. In addition, a derivatization strategy incorporating N‐terminus acetylation was developed that allowed the direct comparison of tandem mass spectra of standard cyclic peptides with those resulting from the TD process, thus eliminating any ambiguity from the direct comparison of their mass spectra (due to gas‐phase cyclization of b‐ions, which can result in sequence scrambling of the precursor ion). Results from these investigations indicated that peptide dehydrated TD products were mostly linear in nature, and water loss was favored from the C‐terminus carboxyl group or, when present, the aspartic acid side chain. Given the predictable nature of the formation of TD dehydration products, their MS/MS analysis can be of utility in providing complementary and confirmatory sequence information of the precursor peptide. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

6.
In the present study, a simple and rapid method for metamizole metabolite 4-methylamino antipyrine (MAA) determination in human plasma was developed, validated and successfully applied to a clinical trial. Chromatographic separation was achieved in HILIC mode on a YMC-Pack SIL column (100 × 2.0 mm; S-5 μm, 30 nm), with a mobile phase consisting of acetonitrile, water and formic acid. Protein precipitation of a small plasma volume using acetonitrile was selected for sample preparation. The multiple reaction monitoring transitions in the positive ionization mode were m/z 218.2 → 56.2 for MAA and m/z 221.2 → 56.2 for MAA-d3 (IS, internal standard). Concentration levels of MAA calibration standards were in the range of 0.100–20 μg/ml. Metamizole conversion into MAA in both water and organic media was investigated, and the level of the conversion in commercially available injection solutions was estimated.  相似文献   

7.
The oxidation of the peptide leucine-enkephalin (YGGFL) induced by the hydroxyl radical (HO*), formed under Fenton-like conditions [Cu (II)/H(2)O(2)], was studied and monitored by LC-MS. The oxidation products identified included products resultant from (a) the insertion of oxygen atoms (1-5), (b) peptide backbone cleavage (short-chain products formed by diamide pathway) and (c) radical-radical crosslinking reactions. In order to identify the modified residues, LC-MS/MS spectra were obtained. The insertion of oxygen atoms into the peptide originated hydroxide, di-hydroxide and/or hydroperoxide derivatives. In addition it was found that the aromatic amino acids are most susceptible to being hydroxylated, while the aliphatic amino acids are more prone to forming hydroperoxides. Oxidation products with double bonds were also identified. The short chain products resulted from the alpha-carbon radical of terminal amino acids (Tyr and Leu). Products resulting from cross-linking reactions between intact carbon-centered peptide radical (with and without one HO group) and a side chain radical (*C(7)H(7)O) were identified. It was found that, although all amino acids residues of the peptide undergo modifications, the N-terminal seems to be prone to oxidative modifications under these conditions.  相似文献   

8.
The characteristic collision energy (CCE) to obtain 50% fragmentation of positively and negatively single charged noncovalent clusters has been measured. CCE was found to increase linearly with the degrees of freedom (DoF) of the precursor ion, analogously to that observed for synthetic polymers. This suggests that fragmentation behavior (e.g. energy randomization) in covalent molecules and clusters are similar. Analysis of the slope of CCE with molecular size (DoF) indicates that activation energy of fragmentation of these clusters (loss of a monomer unit) is similar to that of the lowest energy fragmentation of protonated leucine–enkephalin. Positively and negatively charged aggregates behave similarly, but the slope of the CCE versus DoF plot is steeper for positive ions, suggesting that these are more stable than their negative counterparts. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

9.
Pneumatically-assisted electrospray tandem mass spectrometry (ES MS/MS) was proposed as a technique for the identification of dimethylarsinoyl-riboside derivatives (arsenosugars) in seaweed (Laminaria). Conditions for the acquisition of MS and MS/MS spectra were optimized. A size-exclusion HPLC (SE HPLC) step was developed for the purification of algal extracts prior to ES MS. The arsenosugar fraction was found to elute prior to the majority of other arsenic compounds. The identity of the compounds expected to be arsenosugar compounds was confirmed by the collision induced dissociation (CID) of the relevant protonated molecule ions. An independent confirmation of the identity of analytes was obtained by two-dimensional (size-exclusion–anion exchange) HPLC–ICP MS with signal identification by spiking with the appropriate arsenosugar standards.  相似文献   

10.
The fragmentation behavior of hydroquinone glycosides involving one or two sugar groups from Fraxinus sieboldiana and their analogue arbutin was investigated systematically by electrospray ionization tandem mass spectrometry in negative ion mode. The characteristic fragmentation reaction of these compounds was through the homolytic and heterolytic cleavage of the O‐glycosidic bond to produce radical aglycone ion ([Y0 ? H]??) and aglycone ion (Y0?), respectively. Unambiguous differentiation between the mono‐O‐glycoside isomers which differ in glycosylation position was achieved by comparing the relative abundance of [Y0 ? H]?? and Y0? ions with the optimized collision energy. In the fragmentation of 1, 4‐di‐O‐glycosides, only the Y0? ion was produced when the first glucosyl residue was expelled. However, both the [Y0 ? H]?? and Y0? ions were present when the second glucosyl residue was eliminated. In addition, an interesting [Y0‐2H]? ion was present in the product ion spectra of hydroquinone glycosides with methoxy group(s) substituted at C‐3 or/and C‐5 positions of the benzene ring. The results of this study can facilitate the rapid determination of hydroquinone glycosides in crude plant extracts and also reveal that the systematic investigation and optimization of collision energy play an important role in the differentiation of isomers which have subtle differences in structures. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
A simple and robust method for quantification of zolpidem in human plasma has been established using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI MS/MS). Es-citalopram was used as an internal standard. Zolpidem and internal standard in plasma sample were extracted using solid-phase extraction cartridges (Oasis HLB, 1 cm3/30 mg). The samples were injected into a C8 reversed-phase column and the mobile phase used was acetonitrile-ammonium acetate (pH 4.6; 10 mm) (80:20, v/v) at a flow rate of 0.7 mL/min. Using MS/MS in the selected reaction-monitoring (SRM) mode, zolpidem and Es-citalopram were detected without any interference from human plasma matrix. Zolpidem produced a protonated precursor ion ([M+H]+) at m/z 308.1 and a corresponding product ion at m/z 235.1. The internal standard produced a protonated precursor ion ([M+H]+) at m/z 325.1 and a corresponding product ion at m/z 262.1. Detection of zolpidem in human plasma by the LC-ESI MS/MS method was accurate and precise with a quantification limit of 2.5 ng/mL. The proposed method was validated in the linear range 2.5-300 ng/mL. Reproducibility, recovery and stability of the method were evaluated. The method has been successfully applied to bioequivalence studies of zolpidem.  相似文献   

12.
A rapid, selective and sensitive liquid chromatography/tandem mass spectrometry (LC‐MS/MS) method was developed and validated for determining bencycloquidium bromide (BCQB) in beagle dog plasma. The plasma sample was deproteinized with methanol which contained l‐ethyl‐bencycloquidium bromide as internal standard, and supernantant was assayed by LC‐MS/MS. The chromatographic separation was performed on a Phenomenex C18 column (100 × 2.0 mm, i.d., 3.0 μm) with a gradient programme mobile phase consisting of methanol and ammonium acetate (5 mm) containing 0.15% acetic acid and at a flow rate of 0.3 mL/min. Electrospray ionization in positive ion mode and selective reaction monitoring was used for the quantification of BCQB with a monitored transitions m/z 330.2 → 142.1 for BCQB and m/z 344.2 → 126.2 for IS. Validation results indicated that the lower limit of quantification was 0.05 ng/mL and the assay exhibited a linear range of 0.05–10.0 ng/mL and gave a correlation coefficient of 0.9998. The intra‐ and inter‐run precisions of the assay were 1.7–4.6 and 3.2–15.6%, respectively, and the intra‐ and inter‐day accuracies were ?8.8 to 1.1 and ?5.0 to 4.6%, respectively. The developed method was applied for the pharmacokinetic study of BCQB in beagle dogs following a single intranasal dose. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

13.
Beraprost sodium is an oral prostacyclin analog that was first approved in 1992 (Japan) for the treatment of peripheral vascular disorders. It is administered orally as a tablet available in strength 20 μg. In this paper, we described a liquid chromatography tandem mass spectrometry method that was developed for the quantification of beraprost in human plasma with high sensitivity at picogram per milliliter concentration. The method had been validated in terms of selectivity, sensitivity, accuracy and precision, matrix effect, linearity, recovery and carry‐over according to the Guideline on Bioanalytical Validation from the European Medicines Agency. The standard calibration curve for beraprost was 9.5–1419 pg/mL. This method has been applied successfully to a bioequivalence study with 60 μg of beraprost (three tablets) in 29 healthy volunteers. The results showed that the two formulations of beraprost are bioequivalent.  相似文献   

14.
Ye S  Yao Z  Na G  Wang J  Ma D 《Journal of separation science》2007,30(15):2360-2369
This paper describes a rapid method for the determination of 14 kinds of sulfonamides (SAs) in wastewater using SPE, and LC-MS/MS with positive ESI (ESI(+)) and selected reaction monitoring (SRM) mode. The SPE was performed on an Oasis hydrophilic-lipophilic-balanced (HLB) cartridge. Chromatographic separation on a C18 column was achieved using a binary eluent containing methanol and water with 0.2% formic acid. Typical recoveries of the analytes ranged from 22.3 to 87.0% at a fortification level of 100 ng/L. The LODs in wastewater except sulfathiazole (3 ng/L) could be detected and quantified at levels as low as 1 ng/L. Finally, the method was applied to water from the municipal outlet and the aquaculture wastewater effluent. Sulfamethazine (SM(2)), sulfamethoxypyridazine (SMP), and sulfamethoxazole (SMZ) were most frequently found in wastewater in a concentration range between 1.2 and 31.7 ng/L.  相似文献   

15.
In this study, we have investigated the fragmentation of the widely used steroidal pharmaceutical drugs (n = 14), complexed by a singly charged proton or alkali metal ion (Li+, Na+, K+) using Ion trap and quadrupole time-of-flight mass spectrometers. Spectra were collected by LC-MS/MS analysis using system automated collision energy i.e., of 25–60 eV. Theoretical calculations were also calculated using DFT software. The metal complexes showed different fragmentation pathways not commonly observed for protonated compounds. There was a distinct difference observed in the relative intensities of some common fragments for free vs. metallated drugs. Some major fragments from protonated and lithium adducts showed close resemblance, while sodium and potassium adducts showed different fragments. Theoretical calculations showed a distinct difference in the position of attachment of proton and metals. This adducts ion fragmentation information will be helpful for the identification of these compounds in complex samples.  相似文献   

16.
An assay based on protein precipitation and liquid chromatography/tandem mass spectrometry (LC-MS/MS) has been developed and validated for the quantitative analysis of lisinopril in human plasma. After the addition of enalaprilat as internal standard (IS), plasma samples were prepared by one-step protein precipitation using perchloric acid followed by an isocratic elution with 10 mm ammonium acetate buffer (pH adjusted to 5.0 with acetic acid)-methanol (70:30, v/v) on a Phenomenex Luna 5 mu C(18) (2) column. Detection was performed on a triple-quadrupole mass spectrometer utilizing an electrospray ionization (ESI) interface operating in positive ion and selected reaction monitoring (SRM) mode with the precursor to product ion transitions m/z 406 --> 246 for lisinopril and m/z 349 --> 206 for enalaprilat. Calibration curves of lisinopril in human plasma were linear (r = 0.9973-0.9998) over the concentration range 2-200 ng/mL with acceptable accuracy and precision. The limit of detection and lower limit of quantification in human plasma were 1 and 2 ng/mL, respectively. The validated LC-MS/MS method has been successfully applied to a preliminary pharmacokinetic study of lisinopril in Chinese healthy male volunteers.  相似文献   

17.
A highly sensitive and specific atmospheric pressure chemical ionization liquid chromatography-tandem mass spectrometry method was developed for serum pharmacokinetic studies of puerarin in rats. Chromatography was carried out on a reversed-phase Phenomenex Synergi 4 microm Fusion-RP80 column (150 x 2.0 mm i.d.) using a mobile phase consisting of acetonitrile-water (10:90, v/v) in 10 mm NH(4)OAc with a flow rate of 0.2 mL/min. Puerarin was analyzed in the multiple reaction monitoring mode with a precursor/product ion transition of m/z 415/267. The method was demonstrated to be specific and sensitive, and a linear response was observed over a range of 2-5000 ng/mL in rat serum. The validated method was successfully applied to the characterization of the pharmacokinetics of puerarin in rat serum after oral administration to spontaneously hypertensive rats. The blood concentration-time profile of puerarin showed a rapid initial increase, reaching a maximum and then declining within 1 h. Puerarin could not be detected after 24 h. The main pharmacokinetic parameters for puerarin after oral administration were as follows: C(max) (3.54 +/- 2.03 mg/L), T(max) (0.68 +/- 0.37 h), AUC(0-t) (7.29 +/- 3.79 mg h/L), AUC(0-infinity) (9.17 +/- 4.87 mg h/L), T(1/2) (1.7 +/- 0.6 h), CL/F (7.24 +/- 4.27 L/h/kg) and V/F (17.88 +/- 13.55 L/h/kg).  相似文献   

18.
A liquid chromatography tandem mass spectrometric method is described for the analysis of homocitrulline in human urine, a key metabolite in the differential diagnosis of hyperammonemia, hyperornithinemia, homocitrullinuria (HHH) syndrome. Urine samples were prepared by mere five-fold dilution with a mixture of internal standards (2H2-citrulline and 2H3-creatinine) used for the simultaneous quantification of creatinine. Analytes were separated on a cyano column and eluted isocratically within seven min. Detection was achieved by monitoring transitions of 190 > 84 and 190 > 127 for homocitrulline, 178 > 115 for 2H2-citrulline, 114 > 44 for creatinine and 117 > 47 for 2H3-creatinine. Calibration curves were linear up to 100 micromol/L. Intraday (n = 7) and interday (n = 6) variations were less than 10%. In urine samples from three siblings confirmed to have HHH syndrome, homocitrulline levels were at 13.3 (74), 21.1 (50) and 108.2 (103) mmol/mol creatinine (micromol/L). Control values were 0–9 mmol/mol creatinine (n = 120). The current method solves specificity issues in homocitrulline determination often encountered with some ninhydrin-based systems (coelution with methionine) and some o-phthalaldehyde-based ones (coelution with taurine), and presents an attractive alternative with a relatively high throughput.  相似文献   

19.
The present paper describes the development and validation of a new reversed-phase liquid chromatography–electrospray ionization tandem mass spectrometric method (RP-HPLC–ESI-MS/MS) for simultaneous determination of pyridine, 2-picoline, 4-picoline and quinoline from mainstream cigarette smoke. Liquid–liquid extraction followed by solid-phase extraction was applied to extract the target analytes from cigarette smoke. Baseline chromatographic separation was achieved by utilizing a Zorbax SB-Aq (4.6 × 150 mm, 5 μm) column in gradient chromatographic conditions with acetonitrile and ammonium acetate buffer as mobile phases. Popular commercially available Indian brand filtered and non-filtered cigarettes were analyzed using the same method. The identification of each chemical was established by chromatographic retention times, analyte specific fragmentation patterns and relative peak area ratios of two product/precursor ion pairs. The limit of detection of this method ranged from 1.74 to 14.32 ng/cig using an injection volume of 20 μl. The reproducibility of this method is excellent and better standard deviations were obtained compared to literature reported values for these chemicals. RSD value is less than 9% for all analytes.  相似文献   

20.
Hyperhomocysteinemia is a risk factor for different diseases. Several methods have been developed to analyze homocysteine and the immunometric ones, although expensive, they are in widespread use. A rapid LC‐MS/MS method for homocysteine assay has been developed for the application of large clinical chemistry routines. Selected reaction monitoring was performed through the transitions m/z 136.0→90.1 for homocysteine and m/z 140.0→94.0 for the internal standard. ESI was used to generate [H+] adduct ions. Chromatographic isocratic separation was achieved using a strong cation exchange column. The mobile phase was methanol/water (20:80 v/v, containing 0.1% formic acid and 1.5 mmol/L ammonium formate in the water phase) at a flow rate of 0.250 mL/min (35°C). Samples treatment consisted in the reduction with DTT and deproteinization with methanol. Recovery, linearity, LOD, LOQ and total imprecision were evaluated to validate the method. Homocysteine values on 100 serum samples were compared with those obtained by HPLC and immunometric methods. The method is robust, selective and precise in the whole range of values studied. Moreover, low reagent cost and easiness of sample treatment make this method useful, not only for research, but also for routine work.  相似文献   