首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new dispersive liquid–liquid microextraction based on solidification of floating organic droplet method (DLLME-SFO) was developed for the determination of volatile aldehyde biomarkers (hexanal and heptanal) in human blood samples. In the derivatization and extraction procedure, 2,4-dinitrophenylhydrazine (DNPH) as derivatization reagent and formic acid as catalyzer were injected into the sample solution for derivatization with aldehydes, then the formed hydrazones was rapidly extracted by dispersive liquid–liquid microextraction with 1-dodecanol as extraction solvent. After centrifugation, the floated droplet was solidified in an ice bath and was easily removed for analysis. The effects of various experimental parameters on derivatization and extraction conditions were studied, such as the kind and volume of extraction solvent and dispersive solvent, the amount of derivatization reagent, derivatization temperature and time, extraction time and salt effect. The limit of detections (LODs) for hexanal and heptanal were 7.90 and 2.34 nmol L−1, respectively. Good reproducibility and recovery of the method were also obtained. The proposed method is an alternative approach to the quantification of volatile aldehyde biomarkers in complex biological samples, being more rapid and simpler and providing higher sensitivity compared with the traditional dispersive liquid–liquid microextraction (DLLME) methods.  相似文献   

2.
In this study, a porous polypropylene frit was coated with polydimethylsiloxane (PDMS) as extraction medium, based on the home-made PDMS-frit, a rapid, simple and sensitive sorptive extraction method was established for analysis of potential biomarkers of lung cancer (hexanal and heptanal) in human serum samples. In the method, derivatization and extraction occurred simultaneously on the PDMS-frit, then the loaded frit was ultrasonically desorbed in acetonitrile. Polymerization, derivatization–extraction and desorption conditions were optimized. Under the optimal conditions, satisfactory results were gained, a wide linear application range was obtained in the range of 0.002–5.0 μmol L−1 (R > 0.997) for two aldehydes, the detection limits (S N−1 = 3) were 0.5 nmol L−1 for hexanal and 0.4 nmol L−1 for heptanal. The relative standard deviations (RSDs, n = 5) of the method were below 7.9% and the recoveries were above 72.7% for the spiked serum. All these results hint that the proposed method is potential for disease markers analysis in complex biological samples.  相似文献   

3.
A new analytical approach, simultaneous derivatization and dispersive liquid–liquid microextraction followed by liquid chromatography–atmospheric-pressure chemical ionization tandem mass spectrometry, has been developed for analysis of hexanal and heptanal in human blood. In the derivatization and extraction procedure a solution of 2,4-dinitrophenylhydrazine (derivatization reagent) in 85 μL acetonitrile (dispersive solvent) and 50 μL tetrachloromethane (extraction solvent) was rapidly injected into the aqueous sample containing hexanal and heptanal. Within a few seconds the aldehydes were derivatized and simultaneously extracted. After centrifugation, the hydrazones in the sediment phase were analyzed by LC–APCI–MS–MS. Derivatization and extraction conditions were investigated systematically. Under the optimum conditions enrichment factors for hexanal and heptanal in a 1-mL sample were 63 and 73, respectively. The calibration plots were linear in the ranges 0.5–100 and 100–1,000 nmol L?1, respectively, and the respective limits of detection (LOD) were 0.17 and 0.076 nmol L?1. Reproducibility and recovery were good. The experimental results were compared with those obtained by use of solid-phase extraction and polymer monolithic microextraction. Because sample derivatization, extraction, and concentration were combined in a single step, the proposed method enabled simple, rapid, inexpensive, and efficient analysis of aldehydes in blood. The method has great potential for clinical analysis of biologically relevant aldehydes.  相似文献   

4.
In this work, a polypropylene frit with porous network structure (20 μm pole size) was first utilized as the mould of polymer monolithic material, poly(methacrylic acid-co-ethylene glycol dimethacrylate) (MAA-co-EDMA) monolith was synthesized within channels and macropores of the frit. A simple and sensitive solid-phase microextraction method based on polymer monolith frit coupled with high-performance liquid chromatography (HPLC) was established and applied to analysis of hexanal and heptanal in biological samples (human urine and serum). In the method, small molecule metabolites (aldehydes) in biological samples derivatized with 2,4-dinitrophenylhydrazine (DNPH), and the formed hydrazones were extracted simultaneously on the monolithic frit and thereafter ultrasound-assisted desorbed with acetonitrile as elution solvent. The experimental parameters with regard to polymerization, derivatization and extraction were investigated. Under the optimal conditions, the linearity was in the range of 0.02–5.0 μmol L−1 (r = 0.9994) for both hexanal and heptanal and the limits of detection (S/N = 3) were 0.81 nmol L−1 for hexanal and 0.76 nmol L−1 for heptanal. The relative standard deviations (RSDs, n = 5) were less than 6.5% for the same monolithic frit and less than 8.9% for the different monolithic frits. Satisfactory recoveries ranging from 70.71% to 88.73% were obtained for the urine samples. The method possesses many advantages including simple setup, fast analysis, low cost, sufficient sensitivity, good biological compatibility and less organic solvent consumption. The proposed method is a useful assistant tool in the clinical early diagnosis of lung disease by monitoring aldehyde biomarker candidates in complex biological samples.  相似文献   

5.
A new technique, headspace single-drop microextraction (HS-SDME) with in-drop derivatization, was developed. Its feasibility was demonstrated by analysis of the model compounds, aldehydes in water. A hanging microliter drop of solvent containing the derivatization agent of O-2,3,4,5,6-(pentaflurobenzyl)hydroxylamine hydrochloride (PFBHA) was shown to be an excellent extraction, concentration, and derivatization medium for headspace analysis of aldehydes by GC-MS. Using the microdrop solvent with PFBHA, acetaldehyde, propanal, butanal, hexanal, and heptanal in water were headspace extracted and simultaneously derivatized. The formed oximes in the microdrop were analyzed by GC-MS. HS-SDME and in-drop derivatization parameters (extraction solvent, extraction temperature, extraction time, stirring rate microdrop volume, and the headspace volume) and the method validations (linearity, precision, detection limit, and recovery) were studied. Compared to liquid-liquid extraction and solid-phase microextraction, HS-SDME with in-drop derivatization is a simple, rapid, convenient, and inexpensive sample technique.  相似文献   

6.
A simple and rapid method has been reported for the determination of carbonyl compounds involving sample preparation by headspace single drop microextraction using 1-butanol as extraction solvent containing 2,4-dinitrophenylhydrazine for hydrazone formation, and direct transfer of the drop into the injector for high-performance liquid chromatography with diode array detection. An angle-cut polytetrafluoroethylene sleeve, 3 mm × 0.5 mm, was fixed at the tip of the syringe needle and this allowed the use of 7 μL drop of solvent drop for extraction and derivatization. The procedure has been optimized with respect to suitable solvent for headspace drop formation, drop volume, concentration of reagent, sample temperature, reaction time, and headspace-to-sample volume ratio. The method has been validated when rectilinear relationship was obtained between the amount of analyte and peak area ratio of hydrazones in the range 0.01-15 mg L−1, the correlation coefficient over 0.996-0.999, and the limit of detection in the range 1.7-24.1 μg L−1. Spiked real samples have been analyzed with adequate accuracy, and application has been demonstrated of the method for analysis of carbonyl compounds formed as oxidation products.  相似文献   

7.
A simple and fast sample preparation method for the determination of nonylphenol (NP) and octylphenol (OP) in aqueous samples by simultaneous derivatization and dispersive liquid–liquid microextraction (DLLME) was investigated using gas chromatography–mass spectrometry (GC/MS). In this method, a combined dispersant/derivatization catalyst (methanol/pyridine mixture) was firstly added to an aqueous sample, following which a derivatization reagent/extraction solvent (methyl chloroformate/chloroform) was rapidly injected to combine in situ derivatization and extraction in a single step. After centrifuging, the sedimented phase containing the analytes was injected into the GC port by autosampler for analysis. Several parameters, such as extraction solvent, dispersant solvent, amount of derivatization reagent, derivatization and extraction time, pH, and ionic strength were optimized to obtain higher sensitivity for the detection of NP and OP. Under the optimized conditions, good linearity was observed in the range of 0.1–1000 μg L−1 and 0.01–100 μg L−1 with the limits of detection (LOD) of 0.03 μg L−1 and 0.002 μg L−1 for NP and OP, respectively. Water samples collected from the Pearl River were analyzed with the proposed method, the concentrations of NP and OP were found to be 2.40 ± 0.16 μg L−1 and 0.037 ± 0.001 μg L−1, respectively. The relative recoveries of the water samples spiked with different concentrations of NP and OP were in the range of 88.3–106.7%. Compared with SPME and SPE, the proposed method can be successfully applied to the rapid and convenient determination of NP and OP in aqueous samples.  相似文献   

8.
A sample pretreatment method for the determination of 18 chlorophenols (CPs) in aqueous samples by derivatization liquid-phase microextraction (LPME) was investigated using gas chromatography–mass spectrometry. Derivatization reagent was spiked into the extraction solvent to combine derivatization and extraction into one step. High sensitivity of 18 CPs derivatives could be achieved after optimization of several parameters such as extraction solvent, percentage of derivatization reagent, extraction time, pH, and ionic strength. The results from the optimal method showed that calibration ranging from 0.5 to 500 μg L−1 could be achieved with the RSDs between 1.75% and 9.39%, and the limits of detection (LOD) are ranging from 0.01 to 0.12 μg L−1 for the CPs. Moreover, the proposed LPME method was compared with solid-phase microextraction (SPME) coupled with on-fiber derivatization technique. The results suggested that using both methods are quite agreeable. Furthermore, the recoveries of LPME evaluated by spiked environmental samples ranged from 87.9% (3,5-DCP) to 114.7% (2,3,5,6-TeCP), and environmental water samples collected from the Pearl River were analyzed with the optimized LPME method, the concentrations of 18 CPs ranged from 0.0237 μg L−1 (3,5-DCP) to 0.3623 μg L−1 (2,3,6-TCP).  相似文献   

9.
In the study, we developed a simple, rapid, sensitive, and inexpensive method for determination of the disease biomarkers of acetone, hexanal and heptanal in human blood. For the first time, derivatization of carbonyls with O-2,3,4,5,6-(pentafluorobenzyl)hydroxylamine (PFBHA) was combined with headspace single-drop microextractin (HS-SDME) and gas chromatography-mass spectrometry (GC–MS) and applied to the analysis of acetone, hexanal, and heptanal in human blood. At first, acetone, hexanal and heptanal in blood were derivatized with PFBHA and formed oximes in several seconds. Sequentially, the oximes were headspace extracted and concentrated by a microdrop solvent. Finally, the extracted oximes were analyzed by GC–MS. HS-SDME conditions and method validations were studied. Due to needing of only 2 μl organic solvent, short extraction time of 8 min, and simple operation, derivatization-HS-SDME was shown to be a rapid, simple, and inexpensive technique for analysis of acetone, hexanal, and heptanal in human blood. Moreover, it had low detection limit values from 0.24 to 0.62 nM, and good reproducibility (R.S.D. less than 12%).  相似文献   

10.
Hexanal and heptanal are endogenous aldehydes coming from membrane lipid oxidation, found in lung cancer patients’ blood, and suggested as lung tumor biomarkers. Here the urinary matrix was investigated instead of blood and the difficulties related to the determination of endogenous substances in biological matrices were faced by developing an external calibration HS-SPME/GC/MS method. The methodology was validated according to international validation procedures and it was verified analyzing unknown biological samples from cancer patients and healthy subjects. Percentage accuracy and precision, ranging from −11.25 to 10.85% and from 0.45 to 4.46%, respectively, were obtained, together with limits of detection (LODs) and lower limits of quantification (LLOQs) of 0.11 and 0.23 pg μL−1 for hexanal and of 0.10 and 0.21 pg μL−1 for heptanal. Analytes percentage recoveries (66.3%, hexanal and 70.5%, heptanal) and stability were evaluated. No analytes degradation was found at room temperature, while the remarkable analytes loss found after 1 month storage suggests analyzing biological samples within a week from storage. Results coming from the analysis of unknown biological samples showed no evident differences of heptanal urinary excretion between lung cancer patients and healthy subjects (0.22–0.95 and 0.21–0.69 pg μL−1, respectively), while hexanal urinary concentrations in cancer patients (0.24–4.36 pg μL−1) were slightly higher than those found in control group ones (0.23–1.26 pg μL−1). The obtained results highly suggest to do further investigations in order to collect statistically significant biological data to discriminate between the pathological state of lung cancer patients and physiological conditions of healthy subjects, using the simple, rapid and cheap method here reported for the quantification of urinary aldehydes.  相似文献   

11.
We describe a simple derivatization method to determine aldehydes. This method is based on derivatization with d-cysteine and consecutive liquid chromatography–tandem mass spectrometry (LC–MS/MS). The optimum derivatization conditions of aldehydes with d-cysteine were 10 min at 50 °C and pH 7.0. The formed alkyl thiazolidine-4-carboxylic acid derivatives were directly injected in LC–MS/MS. In the established condition, the method was used to detect eight aldehydes in beverages. The limit of detection (LOD) and limit of quantification (LOQ) of the aldehydes were 0.2–1.9 μg L−1 and 0.7–6.0 μg L−1 and the relative standard deviation was less than 2.0% at concentrations of 0.1 mg L−1 and 1.0 mg L−1 with the exception of octanal. All the beverage samples had detectable levels of methanal (0.033–0.145 mg L−1), ethanal (0.085–2.12 mg L−1), propanal (ND to 0.250 mg L−1), butanal (ND to 0.003 mg L−1), pentanal (ND to 0.471 mg L−1), hexanal (ND to 0.805 mg L−1), heptanal (0.019–3.91 mg L−1) and octanal (0.029–0.118 mg L−1).  相似文献   

12.
Sharma N  Jain A  Singh VK  Verma KK 《Talanta》2011,83(3):994-999
Solid-phase extraction (SPE) of phenol and chlorophenols, their derivatization to methyl ethers, headspace single-drop microextraction (HS-SDME) of methyl ethers using 1-butanol as extraction solvent, and direct transfer of the drop into the injector for high performance liquid chromatography with diode array detection (HPLC-DAD) have been reported. A flanged-end polytetrafluoroethylene sleeve, 3 mm × 0.5 mm, placed at the tip of the syringe needle, allowed the use of 10 μL solvent drop for extraction. The procedure has been optimized for variables involved in SPE and HS-SDME. A rectilinear relationship was obtained between the amount of chlorophenols and peak area ratio of their methyl ethers/internal standard (4-methoxyacetophenone) in the range 0.01-10 mg L−1, correlation coefficient in the range 0.9956-0.9996, and limit of detection in the range 1.5-3.9 μg L−1 when HS-SDME alone was used for sample preparation. When using coupled SPE and HS-SDME, the linear range obtained was 0.1-500 μg L−1, correlation coefficient in the range 0.9974-0.9998, and the limit of detection in the range 0.04-0.08 μg L−1. Spiked real samples have been analyzed with adequate accuracy, and application of the method has been demonstrated for the analysis of chlorophenols formed upon bamboo pulp bleaching.  相似文献   

13.
An alternative method for gas chromatographic determination of haloacetic acids (HAAs) in water using direct derivatization followed by hollow fiber membrane liquid-phase microextraction (HF-LPME) has been developed. The method has improved the sample preparation step according to the conventional US EPA Method 552.2 by combining the derivatization and the extraction into one step prior to determination by gas chromatography electron captured detector (GC-ECD). The HAAs were derivatized with acidic methanol into their methyl esters and simultaneously extracted with supported liquid hollow fiber membrane in headspace mode. The derivatization was attempted directly in water sample without sample evaporation. The HF-LPME was performed using 1-octanol as the extracting solvent at 55 °C for 60 min with 20% Na2SO4. The linear calibration curves were observed for the concentrations ranging from 1 to 300 μg L−1 with the correlation coefficients (R2) being greater than 0.99. The method detection limits of most analytes were below 1 μg L−1 except DCAA and MCAA that were 2 and 18 μg L−1, respectively. The recoveries from spiked concentration ranged from 97 to 109% with %R.S.D. less than 12%. The method was applied for determination of HAAs in drinking water and tap water samples. The method offers an easy one step high sample throughput sample preparation for gas chromatographic determination of haloacetic acids as well as other contaminants in water.  相似文献   

14.
A novel method for analysis of essential oil in Cuminum cyminum L. using simultaneous ultrasonic nebulization extraction and headspace single drop microextraction (UNE-HS-SDME) followed by gas chromatography-mass spectrometry was developed. Experimental parameters, including the kind of suspended solvent, microdrop volume, sample amount, extraction time, enrichment time and salt concentration were examined and optimized. Compared with hydrodistillation (HD), UNE-HS-SDME provides the advantages of a small amount of sample (50 mg), time-saving (20 min), simplicity, cheapness and low toxicity. In addition, UNE-HS-SDME also provided higher enrichment efficiency and sensitivity compared with stirring extraction (SE)-HS-SDME, ultrasonic assistant extraction (UAE) and UNE. Some constituents in the essential oil, were identified and the detection limits for β-pinene, p-cymene and γ-terpinene range from 6.67 pL L−1 to 14.8 pL L−1. The results indicated that the UNE-HS-SDME is simple and highly efficient extraction and enrichment technique.  相似文献   

15.
A comparative study of six SPE conventional and non-conventional sorbent materials (silica RP-C18, LiChrolut EN, Amberlite XAD-2, C60 fullerene, multiwall carbon nanotubes and graphitized carbon black) was carried out for the in situ derivatization/preconcentration of eight aldehydes with 2,4-dinitrophenylhydrazine. Although two of the sorbents, LiChrolut EN and RP-C18, turned out to be the most suitable for ultratrace analysis of the aldehydes, LiChrolut EN showed higher capacity for 2,4-dinitrophenylhydrazine trapping (higher efficiency for the in situ derivatization reaction) and superior performance in terms of sensitivity (likely a result of its increased sample breakthrough volume). The LiChrolut EN-based method combined with LC–MS/MS allowed the determination of aldehydes over the linear range of 0.02–15 μg l−1, with limits of detection at 6–24 ng l−1 and precision of 3.2–7.2%. The method was applied to determine low-molecular mass aldehydes in water samples. These results indicate that the method proposed is a straightforward and sensitive tool for the determination of these aldehydes in water samples providing better results than those LC–MS/MS reported alternatives in terms of the limit of detection, sample requirements for analysis and cost.  相似文献   

16.
Chen L  Ding L  Yu A  Yang R  Wang X  Li J  Jin H  Zhang H 《Analytica chimica acta》2007,596(1):164-170
This paper describes a new method for the determination of total flavonoids in Platycladus orientalis (L.) Franco. The method was based on dynamic microwave-assisted extraction (DMAE) coupled with on-line derivatization and ultraviolet-visible (UV-vis) detection. The influence of the experimental conditions was tested. Maximum extraction yield was achieved using 80% aqueous methanol of extraction solvent; 80 W of microwave output power; 5 min of extraction time; 1.0 mL min−1 of extraction solvent flow rate. The derivatization reaction between aluminium chloride and flavonoid is one of the most sensitive and selective reactions for total flavonoids determination. The optimized derivatization conditions are as follows: derivatization reagent 1.5% aluminium chloride methanol solution; reaction coil length 100 cm; derivatization reagent flow rate 1.5 mL min−1. The detection and quantification limits obtained are 0.28 and 0.92 mg g−1, respectively. The intra-day and inter-day precisions (R.S.D.) obtained are 1.5% and 4.6%, respectively. Mean recovery is 98.5%. This method was successfully applied to the determination of total flavonoids in P. orientalis (L.) Franco and compared with heat reflux extraction. The results showed that the higher extraction yield of total flavonoids was obtained by DMAE with shorter extraction time (5 min) and small quantity of extraction solvent (5 mL).  相似文献   

17.
Elci L  Kolbe N  Elci SG  Anderson JT 《Talanta》2011,85(1):551-555
Solid-phase extraction (SPE) followed by derivatization and gas chromatography-atomic emission detection (GC-AED) was evaluated for the determination of five chlorophenols (CPs) in water samples. The derivatization was based on the esterification of phenolic compounds with ferrocenecarboxylic acid. The determination of the derivatized phenols was performed by GC-AED in the iron selective detection mode at 302 nm. The described method was tested on spiked water samples.The overall method gave detection limits of 1.6-3.7 ng L−1 and recoveries of 90.9-104.5% for the examined mono- to trichlorophenols in 10 mL water samples. The CPs extracted from a 10 mL water sample with SPE were concentrated into 100 μL of organic solvent, a preconcentration factor of 100. The method was applied to lake and tap water samples, and CP contents between 6 and 51 ng L−1 in lake water and between below the detection limit and 8 ng L−1 in tap water were found for different CPs. The method is quick, simple and gives excellent recoveries, limits of detection and standard deviations.  相似文献   

18.
Solid-phase extraction (SPE) was combined with headspace solid-phase microextraction (HS-SPME) for the highly effective enrichment of 17 ultra trace organochlorine pesticides in water samples. The target compounds were successfully transferred from water samples to a gas chromatography capillary column by means of four consecutive steps, namely SPE, solvent conversion, HS-SPME, and thermal desorption of the SPME fiber. Parameters, including elution volume and breakthrough volume in the SPE step, temperature in the solvent conversion step, and fiber type, ionic strength, extraction temperature, extraction time, and pH in the SPME step were optimized to improve the performance of the method through either single factor comparative experiment or the orthogonal experimental design approach. After optimization, the method gave high sensitivity with a method detection limit ranging from 0.0018 to 0.027 ng L−1, good repeatability with a relative standard deviation less than 20% (n = 4) and acceptable recovery with a value mostly exceeding 60%. External standard calibration was employed for the quantification, and a wide linear range (from 0.0010 to 60 ng mL−1) with R2 values ranging from 0.9988 to 0.9999 were observed. In the end, the method was successfully applied to the Arctic samples, and the results showed that, among all the organochlorine pesticides, hexachlorocyclohexanes (HCHs) were the most predominant in the Arctic surface water body with sum of their concentrations ranging from 0.262 to 3.156 ng L−1.  相似文献   

19.
A stir bar sorptive extraction with liquid desorption followed by large volume injection coupled to gas chromatography-quadrupole mass spectrometry (SBSE-LD/LVI-GC-qMS) was evaluated for the simultaneous determination of higher alcohol acetates (HAA), isoamyl esters (IsoE) and ethyl esters (EE) of fatty acids. The method performance was assessed and compared with other solventless technique, the solid-phase microextraction (SPME) in headspace mode (HS). For both techniques, influential experimental parameters were optimised to provide sensitive and robust methods. The SBSE-LD/LVI methodology was previously optimised in terms of extraction time, influence of ethanol in the matrix, liquid desorption (LD) conditions and instrumental settings. Higher extraction efficiency was obtained using 60 min of extraction time, 10% ethanol content, n-pentane as desorption solvent, 15 min for the back-extraction period, 10 mL min−1 for the solvent vent flow rate and 10 °C for the inlet temperature. For HS-SPME, the fibre coated with 50/30 μm divinylbenzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS) afforded highest extraction efficiency, providing the best sensitivity for the target volatiles, particularly when the samples were extracted at 25 °C for 60 min under continuous stirring in the presence of sodium chloride (10% (w/v)). Both methodologies showed good linearity over the concentration range tested, with correlation coefficients higher than 0.984 for HS-SPME and 0.982 for SBES-LD approach, for all analytes. A good reproducibility was attained and low detection limits were achieved using both SBSE-LD (0.03-28.96 μg L−1) and HS-SPME (0.02-20.29 μg L−1) methodologies. The quantification limits for SBSE-LD approach ranging from 0.11 to 96.56 μg Land from 0.06 to 67.63 μg L−1 for HS-SPME. Using the HS-SPME approach an average recovery of about 70% was obtained whilst by using SBSE-LD obtained average recovery were close to 80%. The analytical and procedural advantages and disadvantages of these two methods have been compared.Both analytical methods were used to determine the HAA, IsoE and EE fatty acids content in “Terras Madeirenses” table wines. A total of 16 esters were identified and quantified from the wine extracts by HS-SPME whereas by SBSE-LD technique were found 25 esters which include 2 higher alcohol acetates, 4 isoamyl esters and 19 ethyl esters of fatty acids. Generally SBSE-LD provided higher sensitivity with decreased analysis time.  相似文献   

20.
Dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-flame ionization detector (GC-FID) was developed for preconcentration and determination of some nitroaromatic compounds in wastewater samples. The effects of different variables on the extraction efficiency were studied simultaneously using experimental design. The variables of interest in the DLLME process were extraction and disperser solvent volumes, salt effect, sample volume, extraction temperature and extraction time. A Plackett-Burman design was performed for screening of variables in order to determine the significant variables affecting the extraction efficiency. Then, the significant factors were optimized by using a central composite design (CCD) and the response surface equations were derived. The optimum experimental conditions found from this statistical evaluation included: sample volume, 9 mL; extraction solvent (CCl4) volume, 20 μL; disperser solvent (methanol) volume, 0.75 mL; sodium chloride concentration, 3% (w/v); extraction temperature, 20 °C and extraction time, 2 min. Under the optimum conditions, the preconcentration factors were between 202 and 314. Limit of detections (LODs) ranged from 0.09 μg L−1 (for 2-nitrotoluene) to 0.5 μg L−1 (for 2,4-dinitrotoluene). Linear dynamic ranges (LDRs) of 0.5-300 and 1-400 μg L−1 were obtained for mononitrotoluenes (MNTs) and dinitrotoluenes (DNTs), respectively. Performance of the present method was evaluated for extraction and determination of nitroaromatic compounds in wastewater samples in the range of microgram per liter and satisfactory results were obtained (RSDs < 10.1%).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号