首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Methotrexate (MTX) is widely used for the treatment of many types of cancer. Folinic acid (FNA) and folic acid (FA) were usually simultaneously supplemented with MTX to reduce the side effects of a folate deficiency. This study, for the first time, included on‐line sample preconcentration by stacking and sweeping techniques under reduced or enhanced electric conductivity in the sample region using short chain alkyl imidazolium ionic liquids (ILs) as micelle forming agents for analyte focusing. Both analyte focusing by micelle collapse (AFMC) and sweeping‐MEKC had been investigated for the comparison of their effectiveness to examine simultaneously MTX, FNA and FA in plasma and urine under physiological conditions. In sweeping‐MEKC, the sample solution without micelles was hydrodynamically injected as a long plug into a fused‐silica capillary pre‐filled with phosphate buffer containing 3.0 mol/L of 1‐butyl‐3‐methylimidazolium bromide (BMIMBr). Using AFMC, the analytes were prepared in BMIMBr micellar matrix and hydrodynamically injected into the phosphate buffer without IL micelles. The conductivity ratio between BGE and sample (γ, BGE/sample) was optimized to be 3.0 in sweeping‐MEKC and 0.33 in AFMC resulting the adequate separation of analytes within 4.0 min. To reduce the possibility of BMIMBr adsorption, an appropriate rinsing protocol was used. The limits of detection were calculated as 0.1 ng/mL MTX, 0.05 ng/mL FNA and 0.05 ng/mL FA by sweeping‐MEKC and 0.5 ng/mL MTX, 0.3 ng/mL FNA and 0.3 ng/mL FA by AFMC. The accuracy was tested by recovery in plasma and urine matrices giving values ranging between 90 and 110%. Both stacking and sweeping by BMIMBr could be successfully used for the rapid, selective and sensitive determination of pharmaceuticals in complex matrices due to its fascinating properties, including high conductivity, good thermal stability and ability to form different types of interactions by electrostatic, hydrophobic, hydrogen bonding and π–π interactions. In sweeping‐MEKC, the using of BMIMBr enhanced the γ factor, k retention factor and the injected amount of sample. Consequently, this technique offers particular potential for higher sensitivity by giving 22‐ and 5‐fold sensitivity enhancement factors (SEFs) of MTX compared to CZE and AFMC, respectively.  相似文献   

2.
Sweeping is a powerful on-line sample preconcentration technique that improves the concentration sensitivity of capillary electrophoresis (CE). This approach is designed to focus the analyte into narrow bands within the capillary, thereby increasing the sample volume that can be injected, without any loss of CE efficiency. It utilizes the interactions between an additive [i.e., a pseudostationary phase (PS) or complexing agent] in the separation buffer and the sample in a matrix that is devoid of the additive used. The accumulation occurs due to chromatographic partitioning, complexation or any interaction between analytes and the additive through electrophoresis. The extent of the preconcentration is dependent on the strength of interaction involved. Both charged and neutral analytes can be preconcentrated. Remarkable improvements—up to several thousandfold—in detection sensitivity have been achieved. This suggests that sweeping is a superior and general approach to on-line sample preconcentration in CE. The focusing mechanism of sweeping under different experimental conditions and its combination with other on-line preconcentration techniques are discussed in this review. The recently introduced techniques of transient trapping (tr-trapping) and analyte focusing by micelle collapse (AFMC) as well as other novel approaches to on-line sample preconcentration are also described.
Joselito P. QuirinoEmail:
  相似文献   

3.
In the present study, an analytical method using capillary electrophoresis with on-line preconcentration technique was developed for rapid determination of melamine in infant formula. Both stacking and sweeping preconcentration techniques had been investigated for the comparison of their effectiveness in melamine analysis. The limit of detection of melamine standard was 0.5 ng/mL for the field amplified sample stacking (FASS) technique and 9.2 ng/mL for the sweeping technique. Although the FASS technique provided better concentration efficacy than the sweeping technique, the matrix effect was more profound with the former. Matrix effect was evaluated by comparing the enhancement factor (EF) of melamine standard and post-extraction spiked infant formula solution. The EF was changed from 429.86 ± 9.81 to the level less than 133.31 with significant peak distortion in the FASS system, and it was remained unchanged in the sweeping system. Sweeping-micellar electrokinetic chromatography (sweeping-MEKC) was demonstrated to be most suitable for real sample analysis. Under optimum sweeping-MEKC conditions, melamine content in infant formulas could be determined within 6 min. The developed solid phase extraction (SPE) procedures coupled with the sweeping-MEKC method was subjected to method validation. Run-to-run repeatability (n = 3) and day-to-day reproducibility (n = 3) of peak area were within 3.6% and 4.8% RSD, respectively. The accuracy was tested by spiking 0.5 and 2 μg/mL of melamine standard in the melamine contaminated milk powder provided by the European Commission, and the recoveries were 93.4 ± 0.5% and 98.7 ± 0.4%, respectively. Results of this study show a great potential for the sweeping-MEKC method as a tool for the fast screening of melamine in infant formulas.  相似文献   

4.
Electrokinetic supercharging (EKS) has been used in the last few years as a powerful tool for separation and on-line preconcentration of different types of analytes. We have developed a valuable modification for EKS system, namely counter-flow EKS (CF-EKS) and applied it for the separation and on-line preconcentration of seven non-steroidal anti-inflammatory drugs (NSAIDs) in water samples. In CF-EKS, a hydrodynamic counter-flow is applied during electrokinetic injection of the analytes within the EKS system. This counter-flow minimises the introduction of the sample matrix into the capillary, allowing longer injections to be performed. Careful choice of the optimum counter-flow as well as the optimum injection voltage allowed the sensitivity to be enhanced by 11,800-fold, giving limits of detection (LODs) of 10.7–47.0 ng/L for the selected NSAIDs. The developed method was validated and then applied for the determination of the studied NSAIDs in drinking water as well as wastewater samples from Hobart city.  相似文献   

5.
Zhang H  Zhou L  Chen X 《Electrophoresis》2008,29(7):1556-1564
An easy, simple, and highly efficient on-line preconcentration method for polyphenolic compounds in CE was developed. It combined two on-line concentration techniques, large-volume sample stacking (LVSS) and sweeping. The analytes preconcentration technique was carried out by pressure injection of large-volume sample followed by the EOF as a pump pushing the bulk of low-conductivity sample matrix out of the outlet of the capillary without the electrode polarity switching technique using five polyphenols as the model analytes. Identification and quantification of the analytes were performed by photodiode array UV (PDA) detection. The optimal BGE used for separation and preconcentration was a solution composed of 10 mM borate-90 mM sodium cholate (SC)-40% v/v ethylene glycol, without pH adjustment, the applied voltage was 27.5 kV. Under optimal preconcentration conditions (sample injection 99 s at 0.5 psi), the enhancement in the detection sensitivities of the peak height and peak area of the analytes using the on-line concentration technique was in the range of 18-26- and 23-44-fold comparing with the conventional injection mode (3 s). The detection limits for (-)-epigallocatechin (EGC), (-)-epicatechin (EC), (+)-catechin (C), (-)-epigallocatechin gallate (EGCG), and (-)-epicatechin gallate (ECG) were 4.3, 2.4, 2.2, 2.0, and 1.6 ng/mL, respectively. The five analytes were baseline-separated under the optimum conditions and the experimental results showed that preconcentration was well achieved.  相似文献   

6.
Cao J  Dun WL 《Talanta》2011,84(1):155-159
In this report, a novel means for the separation and sweeping of flavonoids (quercetin, rutin, calycosin, ononin and calycosin-7-O-β-d-glucoside) by microemulsion electrokinetic chromatography using mixed anionic and cationic surfactants as modified pseudostationary phase was presented. The optimized background electrolyte consisted of 0.5% (w/v) ethyl acetate, 2.0% (w/v) SDS, 9 mM DTAC, 4.0% (w/v) 1-butanol and 10 mM sodium borate or 25 mM phosphoric acid. We systematically investigated the separation and preconcentration conditions, including the concentrations of surfactant, types of sweeping, sample matrix, the effect of high salt or acetonitrile, and sample injection volume. It was found that the use of mixed surfactants significantly enhanced the separation efficiency through the change of the efficient electrophoretic mobility of analytes. Compared with normal sample injection, 185-508-fold sensitivity enhancement in terms of limit of detection was achieved through effective sweeping of large sample volume at 50 mbar pressure (up to 45% capillary length). At last, the proposed method was suitable for the determination of Radix Astragali sample.  相似文献   

7.
A sol–gel titania poly(tetrahydrofuran) (poly-THF) coating was developed for capillary microextraction hyphenated on-line with high-performance liquid chromatography (HPLC). Poly-THF was covalently bonded to the sol–gel titania network which, in turn, became chemically anchored to the inner surface of a 0.25 mm I.D. fused silica capillary. For sample preconcentration, a 38-cm segment of the sol–gel titania poly-THF coated capillary was installed on an HPLC injection port as a sampling loop. Aqueous samples containing a variety of analytes were passed through the capillary and, during this process, the analytes were extracted by the sol–gel titania poly-THF coating on the inner surface of the capillary. Using isocratic and gradient elution with acetonitrile/water mobile phases, the extracted analytes were desorbed into the on-line coupled HPLC column for separation and UV detection. The sol–gel titania poly-THF coating was especially efficient in extracting polar analytes, such as underivatized phenols, alcohols, amines, and aromatic carboxylic acids. In addition, this coating was capable of extracting moderately polar and nonpolar analytes, such as ketones and polycyclic aromatic hydrocarbons. The sol–gel titania poly-THF coated capillary was also able to extract polypeptides at pH values near their respective isoelectric points. Extraction of these compounds can be important for environmental and biomedical applications. The observed extraction behavior can be attributed to the polar and nonpolar moieties in the poly-THF structure. This coating was found to be stable under extremely low and high pH conditions—even after 18 h of exposure to 1 M HCl (pH ≈0.0) and 1 M NaOH (pH ≈14.0).  相似文献   

8.
Mitotane is a cytotoxic drug used in the treatment of inoperable adrenocortical carcinoma, it inhibits steroidogenesis as well, and therefore monitoring the level of steroid hormones in patients treated with mitotane is a crucial point of therapy. Hence, we have developed a simple, fast, and efficient electrophoretic method combined with reverse polarity sweeping as online preconcentration technique and dispersive liquid–liquid microextraction for the simultaneous determination of mitotane, its main metabolite DDA, and five steroid hormones (progesterone, testosterone, epitestosterone, cortisol, and corticosterone) in urine samples. In addition, a new sample matrix consisting of β-CD2SDS1 complexes for a high hydrophobic compounds solubilization was developed. Approach based on the application of β-cyclodextrin and SDS complex of a ratio 2:1 allowed for hydrodynamic injection into the capillary of a solution containing both mitotane and other analytes. The detection limits of the analytes for the reverse polarity sweeping-dispersive liquid–liquid microextraction method were found to be in the range of 1.5–3 ng/mL, which were approximately 1000 times lower than in the conventional hydrodynamic injection (5 s, 0.5 psi) without any preconcentration procedure. All analytes were completely resolved in less than 13 min by uncoated silica capillary with an inner diameter of 75 μm (ID) × 60 cm. Electrophoretic separation was performed in reverse polarity with a voltage of –25 kV with a background electrolyte (BGE) consisting of 100 mM SDS, 25% ACN, 25 mM phosphate buffer (pH 2.5), and 7 mM β-cyclodextrin.  相似文献   

9.
A flow injection on-line sorption system was developed for the separation and preconcentration of traces of Ag, Cd, Co, Ni, Pb, U and Y from natural water samples with subsequent detection by ICP TOF MS. Simultaneous preconcentration of the analytes was achieved by complexation with the chelating reagent 1-phenyl-3-methyl-4-benzoylpyrazol-5-one immobilized on the inner walls of a (200 cm × 0.5 mm) PTFE knotted reactor. The analytes were eluted and transported to an axial ICP TOF MS system with 1% (v/v) HNO3 containing 0.3 μg l−1 of Rh as an internal standard using ultrasonic nebulization. The detection limits (3σ) varied from 0.3 ng l−1 for Y to 15.2 ng l−1 for Ni and the precision (R.S.D.) was better than 4%. Using a loading time of 90 s and a sample flow rate of 4.5 ml min−1, enhancement factors of 3-14 were obtained for the different analytes in comparison with their direct determination by ICP TOF MS with ultrasonic nebulization without preconcentration. The accuracy of the method was demonstrated by analysis of water based certified reference materials.  相似文献   

10.
Practical considerations for the injection and separation of nitroaromatic explosives in seawater sample matrices are discussed. The use of high surfactant concentrations and long electrokinetic injections allows for improved detection limits. Sensitivity was enhanced by two mechanisms, improved stacking at the detector-side of the sample plug and desorption of analyte from the capillary wall by surfactant-containing BGE from the inlet side of the sample plug. Calculated limits of detection (S/N = 3) for analytes prepared in pure seawater were 70–800 ppb with injection times varying from 5 to 100 s.  相似文献   

11.
A field-amplified sample injection (FASI) technique was elaborated for fast and sensitive determination of selected central nervous system drugs in human urine samples. Factors affecting the sensitivity enhancement, such as background electrolyte (BGE) and the analytical matrix composition were optimized and discussed. Pseudo-isotachophoresis (p-ITP) mechanism contribution in preconcentration mechanism was discussed. All separations were performed in uncoated fused silica capillaries 50 μm × 57 cm at 22 kV. The optimized analytical matrix was composed of 0.25 mM HCOOH in 90% (v/v) methanol, while BGE contained 45 mM TRIS/HCl (pH 2.20). The head-column injection was performed in 0.25 mM HCOOH water solution (3 s, 3.45 kPa). Sample was introduced into the capillary by electrokinetic injection (70 s, 5 kV) followed by short BGE plug (3 s, 3.45 kPa). Seven psychiatric drugs (olanzapine, prochlorperazine dimaleate, trifluoperazine dihydrochloride, perphenazine, promazine hydrochloride, clomipramine hydrochloride, and chlorprothixene hydrochloride) were separated in about 6 min. The elaborated method was additionally supported with dispersive liquid–liquid microextraction (DLLME) technique which in summary with FASI provided about 8000–13,000-fold sensitivity enhancement in comparison to the capillary zone electrophoresis (CZE) method with standard hydrodynamic injection (5 s, 3.45 kPa).  相似文献   

12.
《Analytica chimica acta》2003,493(1):35-45
A novel, versatile and sensitive continuous-flow on-line solid phase fluorescence based system is proposed for the simultaneous determination of benomyl and carbendazim. The continuous-flow system is based on the on-line preconcentration and resolution of the pesticides on a solid sensing zone, followed by the sequential measure of their native fluorescence, monitored at 235/306 and 293/398 nm (λexc/λem for carbendazim and benomyl, respectively), and later desorption of these analytes (from the flow-through cell filled with C18 silica gel) using aqueous methanol mixtures as carrier and eluent solutions.A double discrimination is used for the simultaneous monitoring of these analytes: (1) the usage of two pair of excitation/emision wavelengths, performed by the use of a multiwavelength fluorescence detection mode and (2) a temporary sequentiation in the arrival of the analytes to the sensing system by on-line separation due to the different kinetics showed by the analytes in the sorption-desorption process performed just in the solid support placed in the flow-through cell. Carbendazim is determined the first, because it shows a weaker retention in the C18 bonded phase silica beads, while benomyl is strongly fixed. Then, benomyl is conveniently eluted from the flow-through sensing zone and its native fluorescence signal is measured (at 398 nm). The sensor was calibrated for two different injection volumes: 400 and 2000 μl. Using a 2000 μl sample volume, the analytical signal showed linearity in the range 0.050-1.0 and 0.020-0.50 μg ml−1 with detection limits of 3.0 and 7.5 ng ml−1 for carbendazim and benomyl, respectively, and R.S.D. values smaller than 2% for both analytes. A recovery study was performed on four different spiked environmental water samples at concentration levels from 0.05 to 0.35 μg ml−1. The recovery percentage ranged from 97 to 104%, and from 98 to 104%, for benomyl and carbendazim, respectively.  相似文献   

13.
Hai-Bo He  Qiong-Wei Yu 《Talanta》2010,82(4):1562-5717
Simultaneous determination of 9 (fluoro)quinolone antibiotics (FQs) was accomplished by capillary electrophoresis-ultraviolet (CE-UV) based on poly(methacrylic acid-co-ethylene glycol dimethacrylate) (MAA-EGDMA) monolith microextraction (PMME) coupled with on-line preconcentration technique of field-amplified sample stacking (FASS). The effects of composition of the acid and organic solvent in the sample solution, sampling time, and voltage on the efficiency of the sample stacking have been systematically investigated. Several parameters that influence extraction efficiency for PMME such as pH of sample solution, extraction volume, and wash and desorption conditions were optimized. In the proposed method, a substantial increase in sensitivity for all the FQs tested was achieved by the combination of PMME procedure with on-line preconcentration of FASS prior to CE analysis. Good linearities were obtained for the 9 tested FQs with the correlation coefficients (R) above 0.9954. The limits of detection (S/N = 3) were found to be 2.4-34.0 ng g−1 and the recoveries ranged from 81.2 to 100% with relative standard deviations less than 11.3%. The proposed PMME-FASS-CE method was applied to the determination of FQs residues in chicken samples.  相似文献   

14.
Several strategies, namely, large volume sample stacking (LVSS), field‐amplified sample injection (FASI), sweeping, and in‐line SPE‐CE, were investigated for the simultaneous separation and preconcentration of a group of parabens. A BGE consisting of 20 mM sodium dihydrogenphosphate (pH 2.28) and 150 mM SDS with 15% ACN was used for the separation and preconcentration of the compounds by sweeping, and a BGE consisting of 30 mM sodium borate (pH 9.5) was used for the separation and preconcentration of the compounds by LVSS, FASI, and in‐line SPE‐CE. Several factors affecting the preconcentration process were investigated in order to obtain the maximum enhancement of sensitivity. The LODs obtained for parabens were in the range of 18–27, 3–4, 2, and 0.01–0.02 ng/mL, and the sensitivity evaluated in terms of LODs was improved up to 29‐, 77‐, 120‐, and 18 400‐fold for sweeping, LVSS, FASI, and in‐line SPE‐CE, respectively. These preconcentration techniques showed potential as good strategies for focusing parabens. The four methods were validated with standard samples to show the potential of these techniques for future applications in real samples, such as biological and environmental samples.  相似文献   

15.
The global determination of anionic surfactants is proposed by using flow injection potentiometry, and by employing specifically developed tubular flow-through ion selective electrodes (ISEs). The low concentration requirements needed for the environmental application are obtained with an on-line preconcentration stage embedded in the flow system, which has as its goal the unattended monitoring of anionic surfactants in surface waters. The on-line preconcentration is achieved by employing an octadecylsilica extraction disk in the FIA system. This stage performs the solid phase extraction (SPE) for the enrichment and purification of the target analytes from common interfering anions. The outlined procedure improves the detection limit of a direct injection system, which is decreased from 10 to 0.25 μM by using a preconcentration volume of 3.0 mL and 50 μL of 75% acetonitrile in water as the eluent. Precision was estimated as 2.9% relative standard deviation (n = 20) for a 0.25 μM (0.070 mg·L− 1) sodium docecylsulfate standard.  相似文献   

16.
A capillary electrophoretic method with UV detection for separation and quantitation of perfluorocarboxylic acids (PFCAs) from C6-PFCA to C12-PFCA has been developed. The optimization of measurement conditions included the choice of the most appropriate type and concentration of buffer in the background electrolyte (BGE), as well as the type and the content of an organic modifier. The optimal separation of investigated PFCAs was achieved with 50 mM phosphate buffer and 40% isopropanol in the BGE using direct UV detection. The optimum wavelength for direct UV detection was optimized at 190 nm. For indirect detection, several chromophores were studied. Five mM 3,5-Dinitrobenzoic acid (3,5-DNBA) in 20 mM phosphate buffer BGE and indirect UV detection at 280 nm gave the optimal detection and separation performance for the investigated PFCAs. The possibility of on-line preconcentration of solutes by stacking has been examined for indirect detection. The detection limits (LODs) determined for direct UV detection ranged from 2 microg/mL for C6-PFCA to 33 microg/mL for C12-PFCA. The LODs obtained for indirect UV detection were comparable to those obtained for direct UV detection.  相似文献   

17.
Solvent-bar microextraction (SBME) based on two-phase (water-to-organic) extraction was for the first time used as the sample pretreatment method for the non-aqueous capillary electrophoresis (NACE) of herbicides of environmental concern. Due to the compatibility of the extractant organic solvent and the NACE separation system, the extract could be introduced directly to the CE system after SBME. Through investigations of the effect of sample pH, extraction time, agitation speed and salt addition on extraction efficiency, the most suitable extraction conditions were determined: sample solution at a pH of 1, without added salt, and stirring at 700 revolutions per minute for 30 min. SBME as applied here was also compared with single-drop microextraction and hollow fiber-protected liquid-phase microextraction. SBME showed the highest extraction efficiency. In addition, field-amplified sample injection with pre-introduced organic solvent plug removal using the electroosmotic flow as a pump (FAEP) was used to enhance the sensitivity further in NACE. Based on studies of the effect of different organic solvents, different lengths of the organic plugs and different volumes of sample injection on stacking efficiency under the most suitable separation conditions, methanol was found to be the most efficient solvent for on-line preconcentration. Combined with SBME, FAEP-NACE achieved limits of detection of between 0.08 ng/mL and 0.14 ng/mL for the studied analytes. This preconcentration approach for NACE was demonstrated to be amenable to aqueous environmental samples by applying it to spiked river water.  相似文献   

18.
In this article, optimization of BGE for simultaneous separation of inorganic ions, organic acids, and glutathione using dual C4D‐LIF detection in capillary electrophoresis is presented. The optimized BGE consisted of 30 mM 2‐[4‐(2‐hydroxyethyl)piperazin‐1‐yl]ethanesulfonic acid, 15 mM 2‐amino‐2‐hydroxymethyl‐propane‐1,3‐diol, and 2 mM 18‐crown‐6 at pH 7.2 and allowed simultaneous separation of ten inorganic anions and cations, three organic acids and glutathione in 20 min. The samples were injected hydrodynamically from both capillary ends using the double‐opposite end injection principle. Sensitive detection of anions, cations, and organic acids with micromolar LODs using C4D and simultaneously glutathione with nanomolar LODs using LIF was achieved in a single run. The developed BGE may be useful in analyses of biological samples containing analytes with differing concentrations of several orders of magnitude that is not possible with single detection mode.  相似文献   

19.
A continuous flow liquid membrane extraction (CFLME)-C18 precolumn-liquid chromatography system was developed for preconcentration and determination of chlorinated phenols (CPs). After preconcentration by CFLME, which is based on the combination of continuous flow liquid-liquid extraction and supported liquid membrane, CPs were enriched in 960 μl of 0.5 mol l−1 NaOH used as acceptor. This acceptor was on-line neutralized and transported onto the C18 precolumn where analytes were absorbed and focused. Then the focused analytes were injected onto the C18 analytical column for separation and detected at 215 nm with a diode array detector. CFLME related parameters such as flow rates, pH of donor and acceptor concentration were optimized. The proposed method presents detection limits of 0.02-0.09 μg l−1 (S/N=3) when 100 ml samples were enriched. The proposed method was successfully applied to determine CPs in tap water and river water samples with spiked recoveries in the range of 70-121%.  相似文献   

20.
A simple and sensitive sweeping micellar electrokinetic chromatography method coupled with UV laser-induced native fluorescence detection has been developed for quantitative analysis of biogenic amines in biofluids. The background electrolyte comprised 30 mmol L−1 phosphoric acid and 20 mmol L−1 sodium dodecyl sulfate. The concentration limits of detection of analytes using sweeping-micellar electrokinetic chromatography (sweeping-MEKC) were in the range 7–100 nmol L−1, which were 250–3600-fold improvement for dopamine, DOPA and epinephrine compared with conventional capillary zone electrophoresis. An improvement of approximately 20-fold was observed for all analytes compared with typical micellar electrokinetic chromatography conditions. Baseline separation was achieved for the all analytes within 12 min and migration-time and peak-area repeatability were better than RSD 0.35% and 5.68%, respectively. The developed method was applied to measure the biogenic amines in biofluids extracted from wheat phloem sap, human plasma and human urine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号