首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Hepatocellular carcinoma (HCC) is one of the top five cancers with the highest incident of a disease worldwide. To understand the mechanisms of hepatocarcinogenesis, proteomics analysis provides a powerful tool to identify proteins that associate with HCC. We developed a two-step procedure for mapping of HCC proteomics. In the first step, in order to simplify the complexity of proteomics of HCC, the subfractionation of complex protein mixtures in HCC into “subproteomes” is presented based on the solubility of protein. While in the second step an automate comprehensive two-dimensional (2D) separation system, coupling strong cation-exchange (SCX) in the first dimension with capillary reversed-phase chromatography (cRPLC) in the second dimension is developed further to separate and analyze proteins associated with HCC. By using this system, complex sample can be injected, desalted, separated and analyzed in complete automatization. The procedure for proteomics analysis was found to be applied for proteins with great molecular mass (>100 000), small molecular mass (<20 000), highly basic (pI > 9.5) and hydrophobicity, which are not well resolved in 2D-gel electrophoresis. In total 229 proteins were identified by using the described proteomics platform. Among them, several proteins related to the process of carcinogenesis were investigated further.  相似文献   

2.
A novel method for the analysis of endogenous lipids and related compounds was developed employing hydrophilic interaction liquid chromatography with electrospray ionization tandem mass spectrometry. A hydrophilic interaction liquid chromatography with carbamoyl stationary phase achieved clear separation of phosphatidylcholine, lysophosphatidylcholine, sphingomyelin, ceramide, and mono‐hexsosyl ceramide groups with good peak area repeatability (RSD% < 10) and linearity (R2 > 0.99). The established method was applied to human plasma assays and a total of 117 endogenous lipids were successfully detected and reproducibly identified. In addition, we investigated the simultaneous detection of small polar metabolites such as amino and organic acids co‐existing in the same biological samples processed in a single analytical run with lipids. Our results show that hydrophilic interaction liquid chromatography is a useful tool for human plasma lipidome analysis and offers more comprehensive metabolome coverage.  相似文献   

3.
啤酒中单糖的衍生化HPLC-ESI-MS测定方法研究   总被引:4,自引:0,他引:4  
单糖类样品在溶液中非常稳定,难于离子化,不适合于进行ESI-MS检测。采用1-苯基-3-甲基-5-吡唑啉酮(PMP)将糖类物质衍生化,HPLC-ESI-MS在线联用,选择性离子扫描方式对几种啤酒样品中的5种单糖进行了分离检测。检出限可达到80pg。  相似文献   

4.
Electrosonic spray ionization (ESSI) has been studied as an interface between high-performance liquid chromatography (HPLC) and mass spectrometry (MS), using sample flow rates up to 3.0 ml min−1. This ionization interface was compared with pneumatically assisted electrospray ionization (ESI) using mass spectrometry for detection. For experiments that did not involve direct comparison of different flow rates, the ESI experiments were performed using post column splitting to work at optimal conditions. ESSI allows the interfacing of conventional or high-resolution liquid chromatography (LC) methods to mass spectrometry without post column splitting. High sample flow rates could be handled without a significant loss of signal intensity using a nebulization gas flow rate of 5.5 L min−1. Since ESI needs to be operated with lower sample flow rates, it is limited to micro/nano LC systems, or post column splitting must be used. In particular, nano LC systems have to be treated with great care and require constant maintenance. When using post-column splitting, the increased diffusion can become a problem especially when using systems with very small void volumes. In all experiments ESSI showed better signal intensities than a commercially available, pneumatically assisted ESI source. ESSI does not require heating of the nebulizer gas, which should help to preserve the original structure of thermally unstable molecules. Therefore, ESSI is presented as an alternative to the commercially available heated ESI sources of AB SCIEX, Thermo Fischer, Agilent and Waters. The observed LC-ESSI-MS ion chromatograms are shown to be very stable even when using flow rates higher than 1.0 ml min−1, which could be very suitable for ultra high performance LC, where sample flow rates up to 2.0 mL min−1 with backpressures up to 1200 bar are used. Also, a difference in the relative intensities of singly and doubly protonated peptide monomers and dimers was observed between the two ionization methods. The coefficients of determination for the calibration of instrument response for Val–Tyr–Val and Met-Enkephalin showed excellent linearity over a wide concentration range (0.1–100 μM), while ESI results were only linear over a much smaller range (0.1–20 μM). The observed behavior is thought to be caused by insufficient ionization efficiency of solutions above ∼20 μM by ESI, exemplifying the robustness of ESSI as an interface between LC and MS.  相似文献   

5.
Summary A sensitive, selective, and rapid method is described for analysis of ceramides in the human stratum coracum by direct coupling of HPLC with an electrospray ion-trap mass spectrometry. Nonaqueous reversed-phase chromatography stabilizes the electrospray ionization, resulting in sensitivity that enables direct measurement of skin lipid extracts with no special sample preparation. Assignment of individual signals to the corresponding ceramide species is based on interpretation of the fragment spectra from MS-MS experiments. This enables much finer differentiation between ceramdies than that achievable by thin-layer chromatography. Summary A sensitive, selective, and rapid method is described for analysis of ceramides in the human stratum corneum by direct coupling of HPLC with an electrospray ion-trap mass spectrometry. Nonaqueous reversed-phase chromatography stabilizes the electrospray ionization, resulting in sensitivity that enables direct measurement of skin lipid extracts with no special sample preparation. Assignment of individual signals to the corresponding ceramide species is based on interpretation of the fragment spectra from MS-MS experiments. This enables much finer differentiation between ceramides than that achievable by thin-layer chromatography.  相似文献   

6.
Summary A simple, low-cost, sensitive and selective HPLC method was developed for the determination of phenazopyridine in human plasma. The method employs UV detection of phenazopyridine and of the internal Standard at 2 different wavelengths. Calibration curves were linear over a large dynamic range, i.e., within 0.05–10.0 μg mL−1 with limit of quantification of 0.05 μg mL−1, and a limit of detection of 0.01 μg mL−1.  相似文献   

7.
Summary Elevated plasma homocysteine is, a known risk factor in arteriosclerotic vascular disease. To measure homocysteine in a large number of samples, we have developed a rapid, simple, robust and inexpensive reversed-phase HPLC method for routine analysis. Mercaptopro-pionylglycine was used as the internal standard and an external calibration in plasma was performed. Improvement was achieved by the use of gradient elution (using a sodium acetate buffer and methanol) resulting in a higher number of samples analyzed per day. Plasma samples were reduced with tributylphosphine and the proteins were precipitated with perchloric acid before addition of internal standard. The analytes were derivatized by use of 7-fluorobenzofurazone-4-sulfonic acid ammonium salt. For calibration human plasma was spiked with nine different concentrations of homocysteine (range 2–50 μmol L−1). The inter-assay precision of replicate (n=29) analysis of the concentration of homocysteine in a sample of pooled plasma was 3.0%. The limit of detection, defined as three times the signal-to-noise ratio, was 0.25 μmol L−1. The linearity of the assay was confirmed for a plasma concentration range of 2–2000 μmol L−1. The variation of duplicate analyses of 842 plasma samples was 2.6±1.7%.  相似文献   

8.
In this work new high performance liquid chromatographic methods in combination with mass spectrometry have been developed for the quantitation of hindered amine light stabilizers (HALS) which are commonly used as monomeric and oligomeric species for stabilization of plastic materials. These analytes are difficult to separate under traditional reversed phase conditions. In the present study new silica-based pH stable reversed phases that had become available recently were investigated for HALS analysis, and turned out to be well suited employing mobile phases at a pH of around 11 adjusted by addition of ammonia. Detection was done by mass spectrometry employing both time-of-flight and triple quadrupole mass analyzers. The performance of electrospray ionization (ESI) as well as atmospheric pressure photoionization (APPI) was investigated and compared. Despite the high pH of the mobile phase, an excellent ionization could be obtained in the positive ion mode. ESI provided slightly lower limits of quantitation (on average a factor of 2) in comparison with APPI. The method allowed the quantitation of a range of different HALS down to 0.05–0.005% (depending on the HALS) in polymeric materials. Sample preparation consisted in dissolving the sample in toluene and precipitation of the polymer with acetone. The procedure can be routinely applied to aging tests of plastic materials in order to predict the lifetime of plastic components.  相似文献   

9.
A simple and sensitive liquid chromatography-tandem mass spectrometry method was developed and validated for determining domperidone in human plasma. The analyte and internal standard (IS; mosapride) were isolated from plasma samples by protein precipitation with methanol (containing 0.1% formic acid). The chromatographic separation was performed on an Xterra MS C(18) Column (2.1 x 150 mm, 5.0 microm) with a gradient programme mobile phase consisting of 0.1% formic acid and acetonitrile at a flow rate of 0.30 mL/min. The total run time was 4.0 min. The analyses were carried out by multiple reaction monitoring using the parent-to-daughter combinations m/z 426 --> 175 and m/z 422 --> 198 (IS). The areas of peaks from the analyte and IS were used for quantification of domperidone. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicated that the lower limit of quantification was 0.2 ng/mL, and the assay exhibited a linear range of 0.2-60.0 ng/mL and gave a correlation coefficient (r(2)) of 0.999 or better. Quality control samples (0.4, 0.8, 15 and 50 ng/mL) in six replicates from three different analytical runs demonstrated an intra-assay precision (RSD) 4.43-6.26%, an inter-assay precision 5.25-7.45% and an overall accuracy (relative error) of <6.92%. The method can be applied to pharmacokinetic and bioequivalence studies of domperidone.  相似文献   

10.
A general screening method based on solid phase extraction (SPE) and liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) was developed and investigated with 124 different doping agents, including stimulants, -blockers, narcotics, -adrenergic agonists, agents with anti-estrogenic activity, diuretics and cannabinoids. Mixed mode cation exchange/C8 cartridges were applied to SPE, and chromatography was based on gradient elution on a C18 column. Ionization of the analytes was achieved with electrospray ionization in the positive mode. Identification by LC/TOFMS was based on retention time, accurate mass and isotopic pattern. Validation of the method consisted of analysis of specificity, analytical recovery, limit of detection and repeatability. The minimum required performance limit (MRPL), established by World Anti-Doping Agency (WADA), was attained to 97 doping agents. The extraction recoveries varied between 33 and 98% and the median was 58%. Mass accuracy was always better than 5 ppm, corresponding to a maximum mass error of 0.7 mDa. The repeatability of the method for spiked urine samples, expressed as median of relative standard deviations (RSD%) at concentrations of MRPL and 10 times MRPL, were 14% and 9%, respectively. The suitability of the LC/TOFMS method for doping control was demonstrated with authentic urine samples.  相似文献   

11.
A simple method using a one-step liquid-liquid extraction (LLE) with butyl acetate followed by high-performance liquid chromatography (HPLC) with positive ion electrospray ionization tandem mass spectrometric (ESI-MS/MS) detection was developed for the determination of itopride in human plasma, using sulpiride as an internal standard (IS). Acquisition was performed in multiple reaction monitoring (MRM) mode, by monitoring the transitions: m/z 359.5 > 166.1 for itopride and m/z 342.3 > 111.6 for IS, respectively. Analytes were chromatographed on an YMC C18 reverse-phase chromatographic column by isocratic elution with 1 mM ammonium acetate buffer-methanol (20: 80, v/v; pH 4.0 adjusted with acetic acid). Results were linear (r2 = 0.9999) over the studied range (0.5-1000 ng mL−1) with a total analysis time per run of 2 min for LC-MS/MS. The developed method was validated and successfully applied to bioequivalence studies of itopride hydrochloride in healthy male volunteers.  相似文献   

12.
This study aimed to establish complementary high performance liquid chromatography (HPLC) methods including three modes of separation: ion pairing, cation exchange, and anion exchange chromatography, with detection by inductively coupled plasma mass spectrometry (ICPMS). The ion pairing mode enabled the separation of inorganic arsenate (As(V)), monomethylarsonic acid (MMA(V)), and dimethylarsinic acid (DMA(V)). However, the ion pair mode was unable to differentiate inorganic arsenite (As(III)) from arsenobetaine (AsB); instead, cation exchange chromatography was used to isolate and quantify AsB. Anion exchange chromatography was able to speciate all of the aforementioned arsenic species. Potential inaccurate quantification problem with urine sample containing elevated concentration of AsB, which eluted immediately after As(III) in anion exchange or ion pairing mode, was overcame by introducing a post-column hydride generation (HG) derivatization step. Incorporating HG between HPLC and ICPMS improved sensitivity and specificity by differentiating AsB from hydride-forming arsenic species. This paper emphasizes the usefulness of complementary chromatographic separations in combination with HG-ICPMS to quantitatively determine concentrations of As(III), DMA(V), MMA(V), As(V), and AsB in the sub-microgram per liter range in human urine.  相似文献   

13.
Summary A fully automated, direct plasma-injection technique using an LC coupled to a quadrupole mass spectrometric detector with an on-line, sample clean-up procedure for two new pharmaceutical products, YM087 and YM440, has been developed. Plasma samples containing YM440 were mixed with internal standard or plasma containing YM087 and were injected into a chromatographic system based on two coupled columns. An extraction column packed with alkyl-diol-silica (ADS) was used for online sample cleanup. Using a back-flush technique analytes were subsequently transferred to an analytical column, for separation. Detection was based on tandem mass spectrometry either in electronspray or in APCI mode. Despite the relatively small volumes of plasma injected, reasonably low limits of quantitation were achieved. Validation of both assays was performed using guidelines concerning method validation. All parameters studied were within acceptance criteria. The methods were successfully applied to clinical pharmacokinetic studies.  相似文献   

14.
In this work, sorbent-attached membrane funnel-based spray ionization mass spectrometry was explored for quantitative analysis of anti-diabetic drugs spiked in human plasma. C18-attached membrane funnel was fabricated for in situ extraction and clean-up to alleviate matrix suppression effect in the ionization process. Repaglinide was used as a target analyte of anti-diabetic drugs. Under optimal working conditions, good linearity (R2 > 0.99) was obtained in the concentration range of 1–100 ng mL−1. The method detection limit of target drugs spiked in the human plasma was around 0.30 ng mL−1. Through the application of an isotope-labeled internal standard, the signal fluctuation caused by residual background matrices was largely alleviated and the precision of measurement (RSD) was below 15%. The recovery of repaglinide for 5, 25, and 100 ng mL−1 of spiked human plasma matrixes ranged from 87% to 112%. The developed method was successfully applied to determine repaglinide in plasma volunteers who orally received a dose of drug association. Our results demonstrated that membrane funnel-based spray is a simple and sensitive method for rapid screening analysis of complex biological samples.  相似文献   

15.
A sensitive and specific method for the determination of memantine in human plasma is presented. Memantine was extracted from plasma and derivatized to the pentafluorobenzoyl derivative in a one-step procedure avoiding any sample concentration steps. Amantadine was used as an internal standard. The compounds were measured by gas chromatography/negative ion chemical ionization mass spectrometry without any further processing. Using this detection mode, the fragment ions at m/z 353 and 325 were obtained at high relative abundance. Calibration graphs were linear over the range 0.117-30 ng ml(-1). At the limit of quantification (LOQ), the inter-assay precision was 2.00% and the intra-assay variability was 3.22%. The accuracy at the LOQ showed deviations of -1.42% (intra-assay) and -2.47% (inter-assay). The method is rugged, rapid and robust and was applied to the batch determination of memantine during pharmacokinetic profiling of the drug.  相似文献   

16.
Sample displacement chromatography (SDC) in reversed-phase and ion-exchange modes was introduced approximately 20 years ago. This method was first used for the preparative purification of peptides and proteins. Recently, SDC in ion-exchange mode was also successfully used for enrichment of low-abundance proteins from human plasma. In this paper, the use of SDC for the separation of plasma proteins in hydrophobic interaction mode is demonstrated. By use of two or more columns coupled in series during sample application, and subsequent elution of detached columns in parallel, additional separation of bound proteins was achieved. Further low-abundance, physiologically active proteins could be highly enriched and detected by ESI-MS/MS.  相似文献   

17.
Summary Short columns packed with highly crosslinked 2.3 μm poly-styrene/divinylbenzene (PS/DVB) particles were used for rapid and efficient separation of proteins and peptides by reversed-phase high-performance liquid chromatography at elevated temperatures. Enhancement of the diffusivities of the sample components at elevated temperatures together with the short diffusion pathlength with the micropellicular polymeric stationary phases were responsible for high efficiency, high speed of analysis, and short column regeneration times. Underivatized PS/DVB beads as well as PS/DVB microspheres which have been modified with polyvinylalcohol or octadecyl chains on the surface were synthesized, employed, and compared to HY-TACH-C18, a commercially available micropellicular octadecyl-silica stationary phase, for the separation of proteins, octapeptides and tryptic protein digests. Highest performance was obtained with the silica- and PS/DVB-based octadecyl stationary phases, which exhibited similar column efficiencies but different selectivities for proteins and peptides. The minimum detectability at 214 nm and the maximum loading capacity for ribonuclease A using analytical 30×4.6 mm I.D. columns were 10 ng (0.6 pmol) and 1 μg, respectively. Finally, reversed-phase HPLC with a 60×2 mm I.D. narrow-bore column packed with micropellicular octadecyl PS/DVB was coupled successfully to electrospray mass spectrometry at a flow-rate of 0.15 mL min−1 and on-line full-scan mass spectra for molecular mass determination and identification of proteins in the lower picomol range were obtained.  相似文献   

18.
19.
The goal of this study was to develop an effective supercritical fluid chromatography method using single quadrupole MS for analysis of all isomeric forms of vitamin E. Finally, two fast and effective methods, the high resolution one and the high speed one, for the determination of 8 vitamin E isomers in human serum were developed.  相似文献   

20.
Chicken is the most consumed meat in North America. Concentrations of arsenic in chicken range from μg kg−1 to mg kg−1. However, little is known about the speciation of arsenic in chicken meat. The objective of this research was to develop a method enabling determination of arsenic species in chicken breast muscle. We report here enzyme-enhanced extraction of arsenic species from chicken meat, separation using anion exchange chromatography (HPLC), and simultaneous detection with both inductively coupled plasma mass spectrometry (ICPMS) and electrospray ionization tandem mass spectrometry (ESIMS). We compared the extraction of arsenic species using several proteolytic enzymes: bromelain, papain, pepsin, proteinase K, and trypsin. With the use of papain-assisted extraction, 10 arsenic species were extracted and detected, as compared to 8 detectable arsenic species in the water/methanol extract. The overall extraction efficiency was also improved using a combination of ultrasonication and papain digestion, as compared to the conventional water/methanol extraction. Detection limits were in the range of 1.0–1.8 μg arsenic per kg chicken breast meat (dry weight) for seven arsenic species: arsenobetaine (AsB), inorganic arsenite (AsIII), dimethylarsinic acid (DMA), monomethylarsonic acid (MMA), inorganic arsenate (AsV), 3-nitro-4-hydroxyphenylarsonic acid (Roxarsone), and N-acetyl-4-hydroxy-m-arsanilic acid (NAHAA). Analysis of breast meat samples from six chickens receiving feed containing Roxarsone showed the presence of (mean ± standard deviation μg kg−1) AsB (107 ± 4), AsIII (113 ± 7), AsV (7 ± 2), MMA (51 ± 5), DMA (64 ± 6), Roxarsone (18 ± 1), and four unidentified arsenic species (approximate concentration 1–10 μg kg−1).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号