 共查询到20条相似文献,搜索用时 109 毫秒
1.
We report the fabrication and performance of a silicon‐on‐glass micro gas chromatography eight‐capillary column based on microelectromechanical systems technology that is 50 cm long, 30 μm wide, and 300 μm deep. According to the theory of a gas chromatography column, an even gas flow among different capillaries play a vital role in the peak broadening. Thus, a flow splitter structure is designed by the finite element method through the comparison of the velocity distributions of the eight‐capillary columns with and without splitter as well as an open tubular column. The simulation results reveal that eight‐capillary column with flow splitters can receive more uniform flow velocity in different capillaries, hence decreases the peak broadening and in turn increases the separation efficiency. The separation experiment results show that the separation efficiency of about 22 000 plates/m is achieved with the chip column temperature programmed for analysis of odorous sulfur pollutants. This figure is nearly two times higher than that of the commercial capillary column coated the similar stationary phase. And the separation time of all the components in the microcolumn is less than 3.8 min, which is faster than the commercial capillary column.  相似文献   

2.
Porous polymer monoliths have been prepared in capillaries with circular or square cross-sections and lateral dimensions of 50, 75, 100 μm as well as in a rectangular 38 μm × 95 μm capillary. These capillaries have been used to determine the effect of the size and shape of their cross-section on the porous and hydrodynamic properties of poly(butyl methacrylate-co-ethylene dimethacrylate) monoliths. The capillaries were studied by scanning electron microscopy and evaluated for their permeability to flow and their performance in the liquid chromatographic separation of a protein mixture comprising ribonuclease A, cytochrome c, myoglobin, and ovalbumin using a linear gradient of acetonitrile in the mobile phase. No differences resulting from channel geometry were found for the various capillary columns. These results demonstrate that standard capillaries with circular geometry are a good and affordable alternative conduit for modeling the processes carried out in microfluidic chips with a variety of geometries.  相似文献   

3.
We report a new device for the estimation of the content of chlorophyll a pigment in water samples as an indicator of water quality. The extraction of the pigment from water was also optimized. 10 mL of water was filtered through a nylon filter (45 μm pore size and 13 mm of diameter), after the chlorophylls were dissolved by immersing the filter in 1 mL of a low non-hazardous solvent as ethanol. An in-valve in-tube SPME device coupled to capillary liquid chromatography with diode array detection was designed. A capillary column of 70 cm in length (0.32 mm i.d. coated with 5% diphenyl-95% polydimethylsiloxane, 3 μm coating thickness) was used as the loop of the injection valve for preconcentration and a Zorbax SB C18 (SiO2-based) 150 mm × 0.5 mm i.d., 5 μm column (Agilent) was used as analytical column. The achieved detection limit was 0.05 μg L−1 and the working range of concentrations was 0.1-1 μg L−1. % RSD values between 2 and 11 were obtained. Chlorophyll a in several water matrices was determined with good results in presence of other pigments such as chlorophyll b, pheophytin a and pheophytin b.  相似文献   

4.
Fabrication of porous frits to retain stationary phases is a critical issue in column preparation for capillary electrochromatography (CEC). In this work, porous frits were prepared by applying an external magnetic field to magnetically responsive particles placed inside a fused-silica capillary. Three batches of uniform magnetite spheres with particle diameters of 0.3, 0.4, and 0.6 μm and saturation magnetization values of 73.03, 74.41, and 77.83 emu/g, respectively, were used as frit particles and octadecyl- and phenyl-bonded silica gels were packed successfully into frit-containing capillaries. The performance of the resulting magnetically immobilized frits and packed columns was evaluated. The electroosmotic mobilities in capillaries containing outlet frit only were found to be reduced by 2–4% whereas the plate heights of an unretained marker increased by 30–50% as compared to those in open capillaries. These variations are believed to be associated with the inhomogeneities of the packed structure of the frits. The magnetically immobilized frits showed adequate mechanical strength to withstand the flow drag force, allowing separation in capillaries packed with 5-μm stationary phases up to 10–15 cm, thus rendering column efficiency and reproducibility comparable with those obtained with sintered frits. Taken together, retaining frits made of uniform magnetite particles serves as a viable alternative to sintered frits for column preparation, which offers several distinct advantages such as ease of preparation, improved durability as compared to sintered frits where the removal of the polyimide coating makes the packed column susceptible to breakage, and use of large-bore capillaries for semipreparative separations.  相似文献   

5.
The objective of the present research is directed towards the optimized use of a 50 μm ID secondary column, in a comprehensive two-dimensional gas chromatography–quadrupole mass spectrometry (GC × GC–qMS) system. The analytical aim was achieved by exploiting a split-flow GC × GC approach, and a rapid-scanning qMS instrument. The stationary phase combination consisted of an apolar (silphenylene polymer) 30 m × 0.25 mm ID column, linked by means of a Y-union, to an MS-connected 1 m × 0.05 mm ID polar one [poly(ethyleneglycol)], and to a 0.20 m × 0.05 mm ID uncoated capillary segment; the latter was connected to a manually operated split-valve. It will be herein demonstrated that the split-flow GC × GC approach, successfully employed in previous H2-based, flame ionization detection experiments, provides equally satisfactory results using mass spectrometric detection and helium as carrier gas. An optimized split-flow GC × GC–qMS method was developed and exploited for the analysis of a perfume sample. The results attained were compared with those observed using the same analytical column combination, but with no flow-splitting. It was found that it is not convenient to employ a 50 μm ID secondary column in a conventional GC × GC–MS instrument. On the contrary, the use a 50 μm ID secondary column, in a split-flow, twin-oven system, provided a good performance. A recently developed comprehensive chromatography software was used for data processing.  相似文献   

6.
Fekete S  Fekete J 《Talanta》2011,84(2):416-423
The performance of 5 cm long narrow-bore columns packed with 2.6-2.7 μm core-shell particles and a column packed with 1.7 μm totally porous particles was compared in very fast gradient separations of polar neutral active pharmaceutical compounds. Peak capacities as a function of flow-rate and gradient time were measured. Peak capacities around 160-170 could be achieved within 25 min with these 5 cm long columns. The highest peak capacity was obtained with the Kinetex column however it was found that as the flow-rate increases, the peak capacity of the new Poroshell-120 column is getting closer to that obtained with the Kinetex column. Considering the column permeability, peak capacity per unit time and per unit pressure was also calculated. In this comparison the advantage of sub-3 μm core-shell particles is more significant compared to sub-2 μm totally porous particles. Moreover it was found that the very similar sized (dp = 2.7 μm) and structured (ρ = 0.63) new Poroshell-120 and the earlier introduced Ascentis Express particles showed different efficiency. Results obtained showed that the 5 cm long narrow bore columns packed with sub-3 μm core-shell particles offer the chance of very fast and efficient gradient separations, thus these columns can be applied for fast screening measurements of routine pharmaceutical analysis such as cleaning validation.  相似文献   

7.
Volatile organic compounds (VOCs) were monitored in the different sections of a wastewater treatment plant (WWTP), the outlet of both the WWTP and rainfall water, and the downstream of the WWTP joining the river in the area or vicinity of an industrial science park located in Hsinchu, Taiwan. Levels of VOCs were determined by collecting air samples over several sampling points and analyzed using gas chromatography. Among VOCs identified in the drainage and effluent system in each season, acetone, isopropanol (IPA) and dimethyl sulfide (DMS) were the major emission species and maximum concentrations were 400.4, 22.8 and 641.2 ppbv, respectively. The ambient air and wastewater sample analysis from neighboring wastewater streams identified pollutants being discharged from unaccounted sources other than the industrial park. According to the 24 h semi-continuous monitoring data (27/7/2002-29/7/2002), the total VOC concentration was an average of 93 ppbv (acetone contributed ∼78%) with a dramatic variation during the day and night. The emission rate of measured VOCs estimated using fixed box model projected an average of 2-4 μg m−2 h−1) during the day and 9-17 μg m−2 h−1 during the night. In addition, the isopleth maps show that the acetone and DMS emissions influence adversely the nearby residential area located at less than 100 m downwind from the plant. Eventually, based on this study, an on-line monitoring and alerting system could be built for a long-term performance, and with regular information on the varying pollutants over time construction of a green strategy and creation of a sustainable environment can be achieved.  相似文献   

8.
A simple and fast capillary chromatographic method has been developed to identify and quantify organic pollutants at sub-ppb levels in real water samples. The major groups of pesticides (organic halogens, organic phosphorous, and organic nitrogen compounds), some hydrocarbons (polycyclic aromatic hydrocarbons), phthalates and some phenols such as phenol and bisphenol A (endocrine disruptors) were included in this study. The procedure was based on coupling, in-tube solid-phase microextraction (IT-SPME) by using a conventional GC capillary column (95% methyl–5% phenyl substituted backbone, 80 cm × 0.32 mm i.d., 3 μm film thickness) in the injection valve to capillary liquid chromatography with diode array detection. A comparative study between the IT-SPME manifold and a column-switching device using a C18 column (35 mm × 0.5 mm i.d., 5 μm particle size) has been performed. The IT-SPME procedure was optimal, it allows reaching limits of detection (LODs) between 0.008 and 0.2 μg/L. No matrix effect was found and recoveries between 70 and 116% were obtained. The precision of the method was good, and the achieved intra- and inter-day variation coefficients were between 2 and 30%. This procedure has been applied to the screening analysis of 28 compounds in whole waters from several points of the Mediterranean coast (Valencia Community, Spain).  相似文献   

9.
Hydrodynamic chromatography (HDC) was used as a size classification and purification method for porous bridged ethyl hybrid (BEH) packing materials (particles) in the micron to sub-micron range. Using packed column HDC, a batch of particles with size 0.76 ± 0.26 μm was fractionated to yield classified material of 1.05 ± 0.16 μm, reducing the relative standard deviation from 33% to 15%. Subsequent chromatographic evaluation of this packing material showed significant improvement in column performance and decrease in flow resistance over the unclassified material. Comparing a column packed with the classified versus non-classified material, the effective flow resistance of the two columns was decreased by 58% and the minimum HETP for the packing material was improved from 4 to 2.5 μm.  相似文献   

10.
A flow injection micro-analyser with an integrated injection device and photometric detection is described. Channels measuring 205-295 μm depth by 265-290 μm maximum width were manufactured by deep UV lithography on two layers of urethane-acrylate oligomers-based photoresist. Hypodermic syringe needles (450 μm diameter) were connected to the channels for introduction of solutions into the system. Plastic optical fibres were connected to the ends of a 5.0 mm long channel, in order to conduct the light from and to a homemade photometer. The device has a total volume of 7.0 μL and three different sample volumes (0.09, 0.22 and 0.30 μL) can be inserted into the system by choosing the appropriate loop of the hydrodynamic injection approach. The micro-analyser, designed as a single line manifold, was evaluated by determining chloride in waters (mercuric thiocyanate method), and chromium (VI) in wastewater and total chromium in metallic alloys (diphenylcarbazide method). For chloride determination two micro-pumps were employed to impel the solutions, while for chromium determination this task was performed by a conventional peristaltic pump. The results obtained in all determinations did not differ significantly from the reference methods at a confidence level of 95%. In the chloride determination, a flow rate of 50 μL min−1 was used, providing a sample frequency of 45 injection h−1, generating ca. 0.7 mg of Hg(II) after an 8-h working day (ca. 20 mL of solution). This result suggests the potential of the micro-analyser towards the reduction of waste, following the philosophy of Green Chemistry.  相似文献   

11.
An approach for rapid optimization of dual-mode gradient high performance liquid chromatography (HPLC) by response surface methodology (RSM) was developed for fast simultaneous separation of hydrophilic and hydrophobic components in Radix et Rhizoma Salviae Miltiorrhizae (Danshen) and its preparations. The aim of this study was to achieve a high throughput RSM optimization using a short ultra-high performance liquid chromatographic (UHPLC) column to simultaneously optimize flow rate and solvent gradient, and then transfer the optimized method to conventional HPLC for routine analytical purposes. The optimization was designed with Box Behnken design (BBD) and the global Derringer's desirability was used for describing the multicriteria response variables. Sixty-two designed experiments were performed by UHPLC with a short sub-2 μm column (2.1 mm × 50 mm, 1.7 μm) and a total running time of only 5 h. The predicted gradient profile was further transferred to a long UHPLC column (2.1 mm × 100 mm, 1.7 μm) and a conventional HPLC columns (2.1 mm × 100 mm, 3.5 μm and 4 mm × 100 mm, 5 μm, respectively). Compared to the published methods, the newly developed dual-mode gradient is faster and more efficient at simultaneously separating hydrophilic and hydrophobic components in Danshen and its preparations.  相似文献   

12.
Today sub-2 μm packed columns are very popular to conduct fast chromatographic separations. The mass-transfer resistance depends on the particle size but some practical limits exist not to reach the theoretically expected plate height and mass-transfer resistance. Another approach applies particles with shortened diffusion path to enhance the efficiency of separations. In this study a systematical evaluation of the possibilities of the separations obtained with 5 cm long narrow bore columns packed with new 2.6 μm shell particles (1.9 μm nonporous core surrounded by a 0.35 μm porous shell, Kinetex™, Core-Shell), packed with other shell-type particles (Ascentis Express™, Fused-Core), totally porous sub-2 μm particles and a 5 cm long narrow bore monolith column is presented. The different commercially available columns were compared by using van Deemter, Knox and kinetic plots. Theoretical Poppe plots were constructed for each column to compare their kinetic performance. Data are presented on polar neutral real-life analytes. Comparison of a low molecular weight compounds (MW = 270–430) and a high molecular weight one (MW ∼ 900) was conducted. This study proves that the Kinetex column packed with 2.6 μm shell particles is worthy of rivaling to sub-2 μm columns and other commercially available shell-type packings (Ascentis Express or Halo), both for small and large molecule separation. The Kinetex column offers a very flat C term. Utilizing this feature, high flow rates can be applied to accomplish very fast separations without significant loss in efficiency.  相似文献   

13.
A practical investigation of frictional heating effects in conventional C18 columns was undertaken, to investigate whether problems found for sub-2 μm columns were also present for those of particle size 3 μm and 5 μm and different internal diameter. The influence of a water bath, a still air heater, and a forced air heater on performance was investigated. Heating effects were substantial, with a decrease in k of almost 15% for toluene over the flow rate range ∼0.4–2.3 mL/min with a 15 cm × 0.46 cm ID column packed with 3 μm particles. Heating effects on retention increased with increasing solute k, with increase in the column ID, with decrease in the column particle size, and with decrease in the set column oven temperature. While the water bath minimised axial temperature gradients and thus its effect on k, radial temperature gradients were potentially serious with this system, especially at high mobile phase velocity, even with columns containing 5 μm particles. In contrast to the effects of axial temperature gradients in 4.6 mm columns, very little difference in Van Deemter plots was noted between the three different thermostats with 2 mm ID columns, even when 3 μm particles were used. However, the efficiency of 2 mm columns for peaks of low or moderate k (k < 4) can be compromised by the extra dead volume introduced by the heating systems, even with conventional HPLC systems with otherwise minimised extra column volume.  相似文献   

14.
Zhao J  Chen Z  Li X  Pan J 《Talanta》2011,85(5):2614-2619
A microfluidic chip manufactured from glass substrate and indium tin oxide (ITO) coated glass use for contactless conductivity detection was developed. The detecting electrodes were fabricated by screen-printing and chemical etching methods using an ITO-coated glass wafer. Then, the glass substrate containing separation channels was bonded with the bare side of the processed ITO-coated glass, thus producing an electrophoresis chip integrated with contactless conductivity detector. The prepared microchip displayed considerable stability and reproducibility. Sensitive response was obtained at optimal conditions (including the gap between electrodes, excitation frequency, and excitation voltage). The feasibility of this microfluidic device was examined by detection of inorganic ions, and further demonstrated by the quantification of aminopyrine and caffeine in a compound pharmaceutical. The two ingredients can be completely separated within 1 min. The detection limits were 8 μg mL−1 and 3 μg mL−1, respectively; with the correlation coefficient of 0.996-0.998 in the linear range from 10 μg mL−1 to 800 μg mL−1. The results have showed that the present method is sensitive, reliable and fast.  相似文献   

15.
In this work, a new type of miniaturized fibre-coupled solid-state light source is demonstrated as an excitation source for fluorescence detection in capillary electrophoresis. It is based on a parabolically shaped micro-light emitting diode (μ-LED) array with a custom band-pass optical interference filter (IF) deposited at the back of the LED substrate. The GaN μ-LED array consisted of 270 individual μ-LED elements with a peak emission at 470 nm, each about 14 μm in diameter and operated as a single unit. Light was extracted through the transparent substrate material, and coupled to an optical fibre (OF, 400 μm in diameter, numerical aperture NA = 0.37), to form an integrated μ-LED-IF-OF light source component. This packaged μ-LED-IF-OF light source emitted approximately 225 μW of optical power at a bias current of 20 mA. The bandpass IF filter was designed to reduce undesirable LED light emissions in the wavelength range above 490 nm. Devices with and without IF were compared in terms of the optical power output, spectral characteristics as well as LOD values. While the IF consisted of only 7.5 pairs (15 layers) of SiO2/HfO2 layers, it resulted in an improvement of the baseline noise as well as the detection limit measured using fluorescein as test analyte, both by approximately one order of magnitude, with a LOD of 1 × 10−8 mol L−1 obtained under optimised conditions. The μ-LED-IF-OF light source was then demonstrated for use in capillary electrophoresis with fluorimetric detection. The limits of detection obtained by this device were compared to those obtained with a commercial fibre coupled LED device.  相似文献   

16.
Greg E. Collins  Qin Lu  Peter Wu 《Talanta》2007,72(1):301-304
A long pathlength, three-dimensional U-type flow cell was microfabricated and evaluated for improved absorbance detection on a glass microdevice. A small diameter hole (75 μm) was laser etched in a thin glass substrate whose thickness (100 μm) defined much of the pathlength of the cell. This substrate was thermally bonded and sandwiched between two different glass substrates. The top substrate contained a typical injection cross and separation microchannel. Projecting out of the plane of the separation device was a 126 μm pathlength flow cell as defined by the laser etched hole and the attached microchannels. The flow cell was connected to a microchannel on the bottom substrate that led to a waste reservoir. The planar, flat windows on the top and bottom of this device made light introduction and collection a simple matter using a light emitting diode (LED) and microscope objective. The experimentally obtained detection limit for rhodamine B was determined to be 0.95 μM, which is nearly identical to the theoretical limit calculated by Beer's Law. A separation of three fluorescent dyes was performed, and direct comparisons were made between the transmittance changes through the narrow pathlength separation microchannel and the adjacent long pathlength, three-dimensional U-type flow cell.  相似文献   

17.
In this approach, a novel method to fabricate an integrated amperometric platform used in off-channel electrophoresis has been introduced. A simple screen printed protocol combining a wet etching procedure was used to define the pattern on a glass substrate, and whole electrodes were constructed by filling the conductive carbon ink into the etched cavities. A simple Teflon tape was used to align this platform with the micro-channel, and the variation of reassembling of this device can be down to 2.2% without the assistance of microscope. This device was characterized by dopamine (DA) and catechol (CA), and the width of half peak is around 4 s, even a 100 μm double T shape injection design and a 550 μm working electrode were used in this work. Under the optimum condition, this device possesses a low background with a noise level of 1.4 pA (peak to peak). The linear range for DA and CA are 0.1–100 μM (R = 0.998) and 0.2–200 μM (R = 0.996) with a theoretical plate number of 1.57 × 104 and 3.46 × 104 (plate/m), respectively.  相似文献   

18.
Detection of polymerase chain reaction (PCR) products obtained from cultured greenhouse fungal pathogens, Botrytis cinerea and Didymella bryoniae has been achieved using a previously developed microfluidic microarray assembly (MMA) device. The flexible probe construction and rapid DNA detection resulted from the use of centrifugal pumping in the steps of probe introduction and sample delivery, respectively. The line arrays of the oligonucleotide probes were “printed” on a CD-like glass chip using a polydimethylsiloxane (PDMS) polymer plate with radial microfluidic channels, and the sample hybridizations were conducted within the spiral channels on the second plate. The experimental conditions of probe immobilization and sample hybridization were optimized, and both complementary oligonucleotides and PCR products were tested. We were able to achieve adequate fluorescent signals with a sample load as small as 0.5 nM (1 μL) for oligonucleotide samples; for PCR products, we achieved detection at the level of 3 ng.  相似文献   

19.
The isolation and analysis of circulating tumor cells (CTCs) from blood are the subject of intense research. Although tests to detect metastasis on a molecular level are available, progress has been hampered by a lack of tumor-specific markers and predictable DNA abnormalities. The main challenge in this endeavor is the small number of available cells of interest, 1–2 per mL in whole blood. We have designed a micromachined device to fractionate whole blood using physical means to enrich for and/or isolate rare cells from peripheral circulation. It has arrays of four successively narrower channels, each consisting of a two-dimensional array of columns. Current devices have channels ranging in width from 20 to 5 μm, and in depth from 20 to 5 μm. Several optimizations resulting in the fabrication of a total of 10 derivative devices have been carried out; only two types are used in this study. Both have increasingly narrower gap widths between the columns along the flow axis with 20, 15, 10, and 5 μm spacing all on one device. The first 20 μm wide segment disperses the cell suspension and creates an evenly distributed flow over the entire device, whereas the others were designed to retain increasingly smaller cells. The channel depth is constant across the entire device, the first type was 10 μm deep and the second type is 20 μm deep. When cells from each of eight tumor cell lines were loaded into the device, all cancerous cells were isolated. In mixing experiments using human whole blood, we were able to fractionate cancer cells without interference from the blood cells. Additionally, either intact cells, or DNA, could be extracted for molecular analysis. The ultimate goal of this work is to characterize the cells on the molecular level to provide non-invasive methods to monitor patients, stage disease, and assess treatment efficacy. Furthermore, this work will use gene expression profiles to gain insights into metastasis.  相似文献   

20.
This paper describes a high pressure device for filling small diameter capillaries with stationary phase solutions is described. A liquid is forced into the capillary column with the help of high pressure syringe whose needle (provided with a side opening) is tightened in a PTFE seal. The device allows use of liquefied gas as solvent. A detailed procedure is given for filling the capillary with stationary phase solution. The performance of the device was evaluated by filling 12 m × 15 μm i. d. glass capillary with 6.5 % (w/v) SE-54.  相似文献   