首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Summary Silica beads of 6-μm average diameter were silanized with methylvinyldiethoxysilane and then subjected to encapsulation with poly(methylvinylsiloxane). The resulting product is a new stationary phase for reversed-phase high performance liquid chromatography (RP-HPLC) which has superior ability for the separation of polar, non-polar and basic compounds. The chromatographic peaks are symmetric. Its stability has been studied; after continuous use for three months the carbon content and chromatographic behaviour of the phase were unchanged. on to the silica surface to given an uniform organic film. Material prepared in this way has both good chromatographic behaviour and superior selectivity. Because contact of the silica matrix with the mobile phase is avoided, the alkali-resisting ability of the stationary phase is increased. The non-specific adsorption of alkaline solutes on to the silica surface is also avoided because of the complete coverage of surface silanol groups. Reports of stationary phases encapsulated with polystyrene [6], polybutadiene [I] and octadecylsiloxane polymers have recently appeared in the literature [3]. In this paper we report the encapsulation of poly-(methylvinylsiloxane) (analogous to the phase SE-31 often used in GC) on to a silica matrix previously modified with methylvinyldiethoxysilane. The resulting phase has superior performance in reversed-phase HPLC.  相似文献   

2.
Summary The theory of the evaporation of the liquid stationary phase is elaborated and experimentally verified. On the basis of this theory the role played by the losses in the amount of liquid phase present is quantitatively determined. General techniques are examined which minimize the losses; these techniques are based on saturating the incoming carrier gas with liquid phase vapours and raising the pressure of the carrier gas in the column, e.g. by connecting a capillary to the column outlet in order to offer resistance to the gas flow. The application of these techniques ensures stable performance of the gas chromatographic columns using a volatile liquid phase.  相似文献   

3.
孙元社  瞿其曙  于淑新  李霜霜  唐涛  李彤 《色谱》2016,34(12):1250-1254
采用扫描电镜、透射电镜和氮气吸附法对制备的新型核壳型色谱固定相进行了表征,结果表明该固定相单分散性好、表面放射状孔道壳层结构均一、孔径分布窄。对该核壳材料的表面进行C18键合修饰,考察其基本色谱性能,色谱柱的理论塔板数超过150000块/m,色谱峰峰形对称,甲苯与乙苯的保留因子之比为1.45,亚甲基选择性优异。将该核壳材料应用于汽车尾气中醛酮类化合物的检测,在优化的色谱条件下,2,4-二硝基苯肼(DNPH)衍生的醛酮类化合物在15 min内获得了较好的分离效果。该核壳型C18色谱固定相具有分离速度快、选择性好、柱效高等特点,适于复杂样品的高效、快速分离分析。  相似文献   

4.
A new type of high performance liquid chromatography (HPLC) stationary phase was prepared, and its chromatographic properties were evaluated. The sorbent was composed of metallacarborane covalently bound to silica. Because of the chemical structure of the immobilized metallacarborane, the synthesized stationary phase was able to interact with nonpolar analytes via hydrophobic interactions. The chromatographic behavior of several low-molecular-weight hydrocarbons on the sorbent under typical reversed-phase conditions was compared with octadecyl-, sulfo phenyl- and aminopropyl-modified silica stationary phases. Moreover, as a consequence of the synthetic protocol employed, the immobilization of the metallacarborane led to the development of a zwitterionic chemically bonded phase, which demonstrated excellent resistance to "phase collapse" in a 100% aqueous environment. Finally, preliminary experiments indicated that the new stationary phase has the potential for utilization in hydrophilic interaction chromatography (HILIC) mode for the separation of polar compounds.  相似文献   

5.
Summary Using two polycyclyic aromatic hydrocarbons as solutes, a comparison is made between a bonded liquid crystal stationary phase and a conventional polymeric C-18 phase. The bonded nematic liquid crystal phase was the silanized form of 4-[4-(allyloxy)benzoyl-oxy]biphenyl and the polymeric phase was Vydac 201TP. Both phases display shape and planarity selectivity as indicated by the results of the variable temperature and mobile phase composition studies. The slot theory of retention can be used to explain these results. However, the liquid crystal phase is more sensitive to molecular geometry, probably due to its more ordered structure on the surface. Variable temperature experiments which compare retention during both heating and cooling provides additional support for this conclusion. With the polymeric bonded C-18 phase, each solute had identical retention at the same temperature during both the heating and cooling cycles. On the bonded liquid crystal phase, measurable differences in retention were observed at identical temperatures depending on whether the column was heated or cooled. This effect is attributed to a degree of partially reversible disordering which occurs as the column temperature was increased. However, conditioning with the appropriate mobile phase can restore the original retention characteristics of the bonded liquid crystal phase.  相似文献   

6.
正A new ionic liquid-based high-performance liquid chromatography stationary phase is reported.A derivative of N-methyl pyrrolidinium tetrafluoroborate was covalently immobilized on the surface of silica particles to prepare silica-based N-methyl pyrrolidinium tetrafluoroborate(SilprMP BF4)stationary phase.The obtained ionic liquid-modified silica was evaluated and confirmed by elemental analysis,infrared spectroscopy,and thermogravimetric analysis.A column was packed with the modified particles.The retention behavior of aromatic compounds,alkyl benzenes,and acidic and basic compounds on the SilprMP BF4 stationary phase was studied under reversed-phase liquid chromatography conditions.The effect of the eluent pH on the separation of the acidic and basic compounds was also studied.The new stationary phase involves multiple retention mechanisms,such as electrostatic,hydrophobic,ion-dipole,and anion-exchange interactions,which might lead to multipurpose separation media.  相似文献   

7.
Reversed phase high performance liquid chromatography (RPLC) is currently the method of choice for the analysis of basic compounds. However, with traditional silica materials, secondary interactions between the analyte and residual silanols produce peak tailing which can negatively affect resolution, sensitivity, and reproducibility. In order to reduce these secondary interactions, which comprise ion exchange, hydrogen bonding, and London forces interactions, chromatographic analyses can be carried out at low or high pH values where silanol groups and basic compounds are mostly uncharged. The chromatographic behaviour of a particular bidentate stationary phase, Zorbax Extend C18, was studied with a set of basic and neutral compounds. Thanks to a higher chemical stability than traditional silica based supports, analyses were carried out with a high pH mobile phase, which represents a good alternative to the acidic mobile phases generally used to reduce ion exchange interactions. The performance of this bidentate stationary phase was also compared with that of other supports and it was proved that it is advantageous to work with high pH mobile phases when analyzing basic compounds.  相似文献   

8.
Summary High performance liquid chromatography was used to separate Cu2+, Ni2+, and Zn2+ ions. A column packed with a -diketone bonded phase on silica gel and a mobile phase composed of trifluoroacetylacetone in acetone was used for the separation. After post-column reaction with a color-forming reagent, the metals were detected by absorption in the visible region.Currently assigned to 1155th Technical Operations Squadron, McClellan Air Force Base, California, 95652, USA  相似文献   

9.
The retention behavior of aromatic hydrocarbons and dansylamino acids on cation-exchangers modified with alkylammonium ions has been examined by microcolumn liquid chromatography. Several parameters affected the retention of analytes, involving concentration of the modifier in the mobile phase, its alkyl chain length and mobile phase composition. Stationary phases modified with a reagent having longer alkyl chains achieved better column efficiency.  相似文献   

10.
11.
聚合离子液体毛细管气相色谱固定相的性能评价   总被引:1,自引:0,他引:1  
陈晓燕  卢凯  齐美玲  傅若农 《色谱》2009,27(6):750-754
离子液体作为毛细管气相色谱固定相的选择性和热稳定性是近年人们关注的课题。本文合成了1-烯基-3-苄基咪唑-二(三氟甲基磺酰)亚胺盐(VBIm-NTf2)离子液体并经毛细管柱内聚合制得了聚合离子液体PVBIm-NTf2色谱柱。与VBIm-NTf2色谱柱相比,PVBIm-NTf2色谱柱具有良好的色谱选择性和热稳定性。PVBIm-NTf2色谱柱对Grob试剂、醇混合物、酯混合物和苯系物等都表现了很好的分离能力,并且色谱峰峰形窄且对称。该聚合色谱柱在250 ℃下老化6 h后仍具有良好的分离能力和选择性。本文还测定了PVBIm-NTf2的Abraham溶剂化参数,解析了该固定相与溶质间的相互作用,相关研究国内尚未见报道。研究表明,对常规离子液体进行柱内聚合是改善常规离子液体气相色谱固定相的热稳定性和选择性的有效途径。  相似文献   

12.
Summary Two commercially available liquid crystals, 4-cyano-4′-n-pentyl-1,1′-bipheny and 4-cyano-4′-n-pentoxy-1,1′-bipheny, are bonded to a silica hydride surface via hydrosilation in the presence of a free radical iniator, t-butyl peroxide. Elemental analysis, diffuse reflectance Fourier trans-form infrared spectroscopy, and13C and29Si CP-MAS NMR spectroscopy are used to confirm the success of the bonding reaction. The13C CP-MAS spectra suggest a difference in the bonded phase morphology of the two materials. Static hydrolytic stability tests indicate these materials do not degrade significantly in both acidic and basic solutions. Chromatographic tests confirm that these two bonded phase behave differently with respect to their retention of PAHs, alkyl-substituted benzenes and benzodiazepines.  相似文献   

13.
高效液相色谱手性固定相法拆分阿折地平对映体   总被引:2,自引:0,他引:2  
张恺  薛娜  李林  李凡  杜玉民 《色谱》2010,28(2):215-217
建立了阿折地平对映体的高效液相色谱拆分方法。采用Chiralpak AD-H (250 mm×4.6 mm, 5.0 μm, Daicel公司)手性色谱柱在正相条件下直接拆分阿折地平对映体,考察了固定相种类、流动相组成及柱温等对阿折地平对映体分离的影响。确定了最佳的拆分条件: 流动相为正己烷-异丙醇(90:10, v/v),流速为0.8 mL/min,检测波长为254 nm;柱温为20 ℃;在此条件下阿折地平对映体的分离度为3.3。该法简单快速,重现性好。  相似文献   

14.
The low temperature effect has been investigated on a set of three different silica-gel micro columns with FC-78 as eluent. An open tubular micro glass capillary, a packed micro glass capillary, and a packed micro teflon column were examined. Temperature dependences of separation factors and theoretical plate numbers were determined. It appears that a decrease in column temperature improves chromatographic selectivity while column efficiency decreases. The compensation temperatures were determined for these systems. The results suggest that the retention mechanism operative in the low temperature range is almost the same as that in the normal temperature range. However, the mechanism differs from that of reversed phase systems.  相似文献   

15.
The low temperature effect has been investigated in reversed phase micro high performance liquid chromatography with various aqueous mobile phase systems by an approach based on enthalpy-entropy compensation. The compensation temperatures, Tc , were determined for these systems, and the results show that the retention mechanism in a lower temperature column is similar to that in a normal temperature column in the reversed phase mode at mobile phase water contents above 9.8%. At lower water contents, the separation mechanism is different from that in the reversed phase mode, but otherwise very similar to that in the normal phase mode.  相似文献   

16.
The solvation parameter model system constants and retention factors were used to interpret retention properties of 39 calibration compounds on a biphenylsiloxane-bonded stationary phase (Kinetex biphenyl) for acetone-water binary mobile phase systems containing 30–70% v/v. Variation in system constants, phase ratios, and retention factors of acetone-water binary mobile phases systems were compared with more commonly used acetonitrile and methanol mobile phase systems. Retention properties of acetone mobile phases on a Kinetex biphenyl column were more similar to that of acetonitrile than methanol mobile phases except with respect to selectivity equivalency. Importantly, selectivity differences arising between acetone and acetonitrile systems (the lower hydrogen-bond basicity of acetone-water mobile phases and differences in hydrogen-bond acidity, cavity formation and dispersion interactions) could be exploited in reversed-phase liquid chromatography method development on a Kinetex biphenyl stationary phase.  相似文献   

17.
卢凯  刘伟  齐美玲  李言  傅若农 《色谱》2010,28(8):731-736
采用静态法将合成的端羟基单阳离子咪唑离子液体1-(6-羟己基)-3-丁基咪唑二(三氟甲基)磺酰亚胺盐(HHBIM-NTf2)和1-(8-羟辛基)-3-丁基咪唑二(三氟甲基)磺酰亚胺盐(HOBIM-NTf2)作为固定相制备离子液体毛细管气相色谱柱。采用Grob试剂、混合醇样品和芳香族异构体混合物对固定相色谱选择性进行了考察,Grob试剂和混合醇组分产生的尖锐、对称的色谱峰形及异构体混合物组分达到基线分离的结果均表明端羟基离子液体固定相具有良好的色谱选择性。HHBIM-NTf2柱和HOBIM-NTf2柱经250 ℃老化8 h后对异构体混合物的分离能力没有明显下降,而HHBIM-NTf2柱经300 ℃老化后仍有理想的异构体选择性,表明端羟基离子液体固定相具有理想的热稳定性。本结果为进一步改善单阳离子型咪唑离子液体固定相的色谱性能提供了有效途径。  相似文献   

18.
Although alkylammonium ionic liquids (ILs) such as ethylammonium nitrate and ethylammonium formate have been used as mobile phase "solvents" for liquid chromatography (LC), we have shown that the IL methylammonium formate (MAF), in part because of its lower viscosity as compared to other ILs, can be an effective replacement for methanol (MeOH) in reversed-phase LC. Plots of log retention factor versus the fraction of MeOH and MAF in the mobile phase indicate quite comparable solvent strength slope values of 2.50 and 2.05, respectively. Using a polar endcapped C18 column, furazolidone and nitrofurantoin using 20% MAF-80% water could be separated in 22 min but no baseline separation is possible using MeOH as the modifier, even down to 10%. Suppression of silanol peak broadening effects by MAF is important, permitting a baseline separation of pyridoxine, thiamine, and nicotinamide using 5% MAF-95% water at 0.7 mL/min. Using 5% MeOH-95% water, severe peak broadening for thiamine is evident. The compatibility of MAF as a mobile phase modifer at the 5% level for LC with mass spectrometry detection of water-soluble vitamins is also shown.  相似文献   

19.
The stationary-phase capacity concepts derived from linear capacity are discussed in connection with the needs of analytical, trace enrichment analysis and preparative chromatography and shown to be unsuited to them. A new concept based on stationary-phase saturation and called “available capacity” is proposed. It generalizes the ion-exchanger exchange capacity to adsorption and partition chromatography when the sampling solvent is the mobile phase. In linear elution chromatography the available capacity is proportional to the solute concentration Co and to the analytical capacity factor k′ for given Co and k′ values, it is independent of the nature of the solute. Furthermore, when both the concentrations and the analytical capacity factors (practically, for Co ≥ 1 M and k′ ≥ 10, respectively) are high, the available capacity reaches a value roughly independent of Co and k′, called “maximum available capacity” and related only to the number of sites available on the stationary phase. Numerous measurements were made in ion-exchange, adsorption, and reversed-phase chromatography. For solutes having a single polar functional group interacting with the stationary phase, the orders of magnitude of the maximum available capacity are 1.2 mmole g?1 for a classical silica gel (Partisil 5 μm, 400m?2 g?1 with a water content of 2.7%); 1.8 mmole g?1 for the Lichroprep RP 8 octyl bonded silica (11.6% carbon content); 3.8 mmole g?1 for an anion exchanger resin of Dowex type.  相似文献   

20.
In striving for the best possible separation, the selectivity of stationary phases as an optimization parameter is often underestimated although there are many ways to influence this powerful tool. This review serves to provide an insight into the various ways of adapting the selectivity of a separation in liquid chromatography. Approaches via temperature and flow rate tuning are discussed as a basis followed by focusing on the stationary phase as the superior optimization parameter. Highly selective stationary phases hereby provide an advantage for groups of similar analytes. For more complex mixtures, separations can be improved using mixed-mode technologies where different retention mechanisms are combined. Serial coupling, mixed-bed columns, and stationary phase optimized selectivity liquid chromatography provide solutions to various degrees. Finally, the advantages of stationary phase tuning over adaption of mobile phase and/or temperature are presented in terms of optimum application range.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号