共查询到20条相似文献,搜索用时 31 毫秒
1.
Alessandro Bacaloni Luciano CallipoEleonora Corradini Piero GiansantiRiccardo Gubbiotti Roberto SamperiAldo Laganà 《Journal of chromatography. A》2009,1216(36):6400-6409
We describe the development of a liquid chromatography with negative-ion atmospheric pressure photoionization tandem mass spectrometric (LC/NI-APPI/MS/MS) method for the simultaneous determination of tetrabromobisphenol A (TBBP-A) and five polybrominated diphenyl ethers (BDE-47, BDE-99, BDE-100, BDE-153 and BDE-154) in water. A mobile phase methanol/acetone/water was used, where acetone acts also as dopant. NI-APPI produced precursor ions corresponding to [M−H]− for TBBP-A, [M−Br+O]−, and [M−2Br+O]− for the BDE congeners studied. Each compound was quantified operating in multiple reaction monitoring mode. Linearity was observed in the range 0.025–10 ng injected for all compounds. Coefficients of determination R2 ranged from 0.9934 to 0.9982. BDEs were poorly retained by solid-phase extraction (SPE) from river water and sewage treatment plant effluent, thus liquid–liquid extraction (LLE) by n-hexane should be used for these samples. The recoveries of TBBP-A and PBDEs from tap water (SPE), river water and industrial wastewater (LLE) were in the range of 81–88%, 78–92%, and 43–99%, respectively, with relative standard deviations below 17%. The limits of detection, based on signal-to-noise ratio of 3, ranged from 0.004 to 0.1 ng injected, and method quantification limits were 0.2–3.3 ng L−1 but BDE47 (20.3 ng L−1). Only TBBP-A was found in a treated industrial sewage at 4 ng L−1, while BDE-99 and BDE-100 were detected on suspended solids. 相似文献
2.
Tina Suominen Markus Haapala Anna Takala Raimo A. Ketola Risto Kostiainen 《Analytica chimica acta》2013
A new and simple APPI interface employing commercially available hardware is used to combine GC to MS. The feasibility of the method is demonstrated in the analysis of urine samples for neurosteroids as their trimethylsilyl (TMS) derivatives. The effect of different dopants (chlorobenzene, toluene, anisole) on the ionization of the TMS derivatives was investigated. With chlorobenzene, the TMS derivatives produced intense molecular ions with minimal fragmentation, and chlorobenzene was selected as best dopant. Protonated molecules in addition to intense molecular ions were produced with toluene and anisole. The performance of the method was verified in the analysis of human urine samples. Chromatographic performance was good with peak half-widths of 3.6–4.3 s, linearity (r2 > 0.990) was acceptable, limits of detection (LODs) were in the range of 0.01–10 ng mL−1, and repeatability was good with relative standard deviations (rsd%) below 22%. The results show that the method is well suited for the determination of neurosteroids in biological samples. 相似文献
3.
4.
Jutta Lintelmann Monica Heil França Evelyn Hübner Georg Matuschek 《Journal of chromatography. A》2010,1217(10):1636-1646
The development, optimization and validation of a liquid chromatography–atmospheric pressure photoionization tandem mass spectrometric (LC–APPI/MS/MS) method for the determination of 15 azaarenes (4-azafluorene, benzo[h] and -[f]quinoline, phenanthridine, acridine, 1-azafluoranthene, 4-azapyrene, benz[a]- and -[c]acridine, -10-azabenzo[a]pyrene, 7,9- and 7,10-dimethylbenz[c]acridine, dibenz[a,j]-, -[c,h] and [a,i]acridine) in airborne particulate matter is described. Each compound was detected and quantified operating in multiple reaction monitoring mode. Extraction of azaarenes was achieved using accelerated solvent extraction (ASE) with dichlormethane/methanol (50/50, v/v). After extraction, no additional clean-up procedure like solid phase or liquid/liquid extraction was necessary. Limits of quantification (S/N × 10) ranged from 0.2 pg/μl to 1.4 pg/μl, matrix dependent recoveries were between 57% and 94%, with relative standard deviations from 8% to 17%. Applicability of the method was demonstrated analyzing 10 samples of particulate matter (PM2.5) collected in winter 2008. In all samples dimethylbenz[c]acridines as well as dibenzacridines were below the limit of quantification, concentration of the remaining analytes were in the range from 0.002 ng/m3 to 0.356 ng/m3. 相似文献
5.
6.
Long-Kai Shi Yu-Lan Liu Hua-Min Liu Ming-Ming Zhang 《Analytical and bioanalytical chemistry》2015,407(13):3605-3616
7.
Fei Yang Haozhe Cui Chunqiong Wang Ying Wang Wenjing Zhu Huimin Deng Shanshan Liu Zhaoyang Bian Junli Lu Gangling Tang Yuan Ji 《Journal of separation science》2023,46(19):2300449
This study used reversed-phase liquid chromatography–tandem mass spectrometry and supercritical fluid chromatography–tandem mass spectrometry for determination of the stereoisomers of chlorfenvinphos and dimethylvinphos in tobacco. Tobacco samples were extracted and purified with a modified quick, easy, cheap, effective, rugged, and safe technique using spherical carbon. The performance of both methodologies was comprehensively compared in terms of methods validation parameters (separation efficiency, linearity, selectivity, recovery, repeatability, sensitivity, matrix effect, etc.). Under optimized conditions, the calibration curves of the stereoisomers of chlorfenvinphos and dimethylvinphos in the range of 10–500 ng/mL showed excellent linearity with R2 ≥ 0.997 in both methods. The adequate recoveries of analytes from three different spiked tobaccos were obtained using reversed-phase liquid chromatography–tandem mass spectrometry (86.1–95.7%) as well as supercritical fluid chromatography–tandem mass spectrometry (86.5–94.0%). The relative standard deviations for spiked samples were all below 7.0%. Compared with supercritical fluid chromatography–tandem mass spectrometry, lower matrix effects and LODs can be obtained in reversed-phase liquid chromatography–tandem mass spectrometry. 相似文献
8.
Gas chromatography coupled to ion trap tandem mass spectrometry (GC–ITMS-MS) is proposed for the analysis of methoxylated polybrominated diphenyl ethers (MeO-PBDEs) in fish and shellfish. MS–MS operating parameters related to the isolation and fragmentation of the precursor ions were optimized to achieve maximum sensitivity and selectivity. This new method allows the determination of both MeO-PBDEs and PBDEs in a single run. Low limits of detection (0.4–2.5 pg injected) and high precision (RSD < 13%) were achieved. A sample treatment based on a selective pressurized liquid extraction (PLE) using Florisil as fat retainer was applied for the analysis of these compounds in fish samples. Method limits of quantification ranged from 0.11 to 0.95 ng g−1 lipid weight for MeO-PBDEs and between 0.18 and 0.50 ng g−1 lipid weight for PBDEs. In addition, good repeatability of the whole method was achieved (RSD < 15%). The suitability of the method was evaluated by analyzing a certified reference material (SRM 1945, whale blubber) with satisfactory results. The developed method was applied to the simultaneous analysis of MeO-PBDEs and PBDEs in fish and shellfish samples from the Mediterranean Sea. 相似文献
9.
A new analytical method was established and validated for the analysis of 27 brominated flame retardants (BFRs), including so called “emerging” and “novel” BFRs (EBFRs and NBFRs) in fish samples. High performance liquid chromatography (HPLC) coupled to Orbitrap mass spectrometry (Orbitrap-MS) employing atmospheric pressure photoionization (APPI) interface operated in negative mode was used for the identification/quantitation of contaminants. HPLC-Orbitrap-MS analysis provided a fast separation of selected analytes within 14 min, thus demonstrating a high throughput processing of samples. The developed methodology was tested by intralaboratory validation in terms of recovery, repeatability, linear calibration ranges, instrumental and method limits of quantitation (i-LOQ and m-LOQ), and where possible, trueness was verified by analysis of certified reference materials (CRMs). Recoveries of analytes were between 80 and 119%, while the repeatability in terms of relative standard deviations (RSDs) was in the range from 1.2 to 15.5%. The measured values for both analyzed CRMs agreed with the provided consensus values, revealing the recovery of reference concentrations in 72–119% range. The elaborated method met the sensitivity criterion according to Commission Recommendation 2014/118/EU on monitoring of BFRs in food products for majority of the compounds. The concentrations of polybrominated diphenyl ethers (PBDEs) in real samples determined by HPLC-APPI-Orbitrap-MS method and validated gas chromatography–high-resolution mass spectrometry (GC–HRMS) method were found to be in a good agreement. 相似文献
10.
11.
This study presents a focused ultrasound solid-liquid extraction (FUSLE) and gas chromatography tandem mass spectrometry method for the determination of brominated diphenyl ethers (BDEs), from mono- to hexa-congeners, in indoor dust. This approach provided a simple, fast, and economical method. After the solvent extraction selection, the FUSLE conditions were studied using a central composite design. Finally, the number of extraction cycles was studied. The selected conditions were 8?mL of 3:1 n-hexane-acetone mixture as extraction solvent, at a power of 65% for 20?s. The proposed method allowed accurate determination of BDEs, with recovery values around 100% and detection limits between 0.05 and 0.8?ng?g(-1). It also has advantages over other existing methods in terms of simplicity, analysis time, and solvent consumption. The analysis of several indoor dust samples showed high concentration values of BDEs 47, 99, 100, 153, and 154 in some of the samples, moreover, BDEs 47 and 99 were found in all samples. 相似文献
12.
13.
Electrophilic attack of aristolactam-nitrenium ion by the C7 position to the exocyclic amino group in the DNA bases led to the formation of the major adducts. In this study, liquid chromatography coupled with electrospray ionization tandem mass spectrometry was applied to the study of DNA adducts of aristolochic acid (AA). When DNA (bases and CT-DNA) was incubated with AA, dG-AAI, dG-AAII, dA-AAI, dA-AAII, dC-AAI, and dC-AAII were detected and characterized. The dC adducts of AA were identified for the first time. The soft ionization technology allowed detection of the intact DNA adducts. High-resolution MS and MS-MS capabilities of a quadrupole time-of-flight mass spectrometer were shown to be efficient for DNA adducts analysis. DNA-AA adducts showed characteristic fragmentation patterns in MS-MS analysis. The dissociative loss of 116 Da from the DNA-AA adducts, which resulted from internal hydrogen transfer and cleavage at the C-N glycosidic bond, provided a characteristic fragment for the structural elucidation. 相似文献
14.
Analysis of 11 polybrominated diphenyl ethers (PBDEs), tetrabromobisphenol A bis 2,3-dibromopropylether (TBBPA-bis), tetrachlorobisphenol A (TCBPA), tetrabromobisphenol A (TBBPA) and hexabromocyclododecanes (HBCDs) was optimized by ultrahigh pressure liquid chromatography/tandem mass spectrometry (UPLC–MS/MS) operating in negative ion (NI) mode. Electrospray ionization (ESI), atmospheric pressure photoionization (APPI) and atmospheric pressure chemical ionization (APCI) sources were tested and for PBDEs APCI gave higher sensitivity than APPI while for TBBPA-bis APCI and APPI showed similar performance. ESI was the best option for TCBPA, TBBPA and HBCDs. Detection limits were between 20 and 59 fg for the compounds analyzed by ESI, 0.10 and 0.72 pg for PBDEs and 6 pg for TBBPA-bis. The matrix effect of sewage sludge extract was also tested showing negligible ion suppression for APCI and an increase of the background level of all investigated pollutants leading to a worsening of the limits of quantification by a factor between 1.2 and 3.3. The UPLC-APCI/MS/MS method for PBDEs, after pressurized liquid extraction (PLE), was validated by comparison with the concentration values from the NIST 1944 standard reference material. The advantages of the methods include low detection limits, PBDE congeners specificity using selected multiple reaction monitoring (MRM) transitions, and the absence of thermal degradation of higher PBDE congeners, especially BDE-209. The methods were applied for the determination of the above reported flame retardants in sewage sludge in order to get more information about the degradation on PBDEs (in particular BDE-209) during municipal wastewater treatments. 相似文献
15.
Ashok Kumar Malik Cristina Blasco Yolanda Picó 《Journal of chromatography. A》2010,1217(25):4018-4040
The use of powerful mass spectrometric detectors in combination with liquid chromatography has played a vital role to solve many problems related to food safety. Since this technique is especially well suited for, but not restricted to the analysis of food contaminants within the food safety area, this review is focused on providing an insight into this field. The basic legislation in different parts of the world is discussed with a focus on the situation within the European Union (EU) and why it favors the use of liquid chromatography–mass spectrometry (LC–MS). Main attention in this review is on the achievements that have been possible because of the latest advances and novelties in mass spectrometry and how these progresses have influenced the best control of food allowing an increase in the food safety and quality standards. Emphasis is given to the potential and pitfalls of the different LC–MS approaches as well as in its possibilities to address current hot issues in food safety, such as the development of large-scale multi-residue methods and the identification of non-target and unknown compounds. Last but not least, future perspectives and potential directions are also outlined highlighting prospects and achievements. 相似文献
16.
Yim Ling Mak Jia Jun Wu Wing Hei Chan Margaret B. Murphy James C. W. Lam Leo L. Chan Paul K. S. Lam 《Analytical and bioanalytical chemistry》2013,405(10):3331-3340
Ciguatera fish poisoning (CFP) is a food intoxication caused by exposure to ciguatoxins (CTXs) in coral reef fish. Rapid analytical methods have been developed recently to quantify Pacific-CTX-1 (P-CTX-1) in fish muscle, but it is destructive and can cause harm to valuable live coral reef fish. Also fish muscle extract was complex making CTX quantification challenging. Not only P-CTX-1, but also P-CTX-2 and P-CTX-3 could be present in fish, contributing to ciguatoxicity. Therefore, an analytical method for simultaneous quantification of P-CTX-1, P-CTX-2, and P-CTX-3 in whole blood of marketed coral reef fish using sonication, solid-phase extraction (SPE), and liquid chromatography tandem mass spectrometry (LC-MS/MS) was developed. The optimized method gave acceptable recoveries of P-CTXs (74–103 %) in fish blood. Matrix effects (6–26 %) in blood extracts were found to be significantly reduced compared with those in muscle extracts (suppressed by 34–75 % as reported in other studies), thereby minimizing potential for false negative results. The target P-CTXs were detectable in whole blood from four coral reef fish species collected in a CFP-endemic region. Similar trends in total P-CTX levels and patterns of P-CTX composition profiles in blood and muscle of these fish were observed, suggesting a relationship between blood and muscle levels of P-CTXs. This optimized method provides an essential tool for studies of P-CTX pharmacokinetics and pharmacodynamics in fish, which are needed for establishing the use of fish blood as a reliable sample for the assessment and control of CFP. Figure
Chromatograph of P-CTXs in whole blood of wild-caught moray eel 相似文献
17.
Residue analysis of glucocorticoids in bovine milk by liquid chromatography–tandem mass spectrometry
Fulvia Caretti Alessandra Gentili Annalisa Ambrosi Lucia Mainero Rocca Maurizio Delfini Maria Enrica Di Cocco Giuseppe D’Ascenzo 《Analytical and bioanalytical chemistry》2010,397(6):2477-2490
A sensitive liquid chromatography–tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of 13 steroidal
anti-inflammatory drugs in bovine milk is presented. Due to their weakly acid nature, analytes were separated by ion suppression
reversed phase chromatography and detected in positive-ion mode by a high flow electrospray source. Dexamethasone-d4 was used
as internal standard. The sample preparation was simple and reliable; it included acidic deproteinization of milk followed
by sample enrichment and clean-up, utilizing a C18 solid phase extraction cartridge. Recoveries exceeded 70% with an intra-day
precision not larger than 12%. The efficiency of the sample clean-up and internal standardization rendered negligible the
matrix effect, estimated by comparing standard and matrix-matched calibration curves. A small-scale reconnaissance was carried
out on several raw and whole fresh milk samples. A large number of analyzed samples showed a chromatographic peak, in the
retention time window of cortisol, at levels included between its decision limit (CCα) and detection capability (CCβ). As
a result of a heat-induced transformation, an isomeric product of triamcinolone was observed during the extract evaporation.
Since this rearrangement might occur during the milk pasteurization process, LC-MS/MS and 1H-NMR investigations were performed out to conclusively differentiate the two isomers. One- and two-dimensional proton NMR
spectra were able to identify the transformation product as 9a-fluoro-11b,16a-trihydroxy-17b-hydroxymethyl-D-homoandrosta-1,4-diene-3,17a-dione. 相似文献
18.
J. Chico A. Rúbies F. Centrich R. Companyó M. D. Prat M. Granados 《Analytical and bioanalytical chemistry》2013,405(14):4777-4786
An analytical method for determination and confirmation of nine coccidiostatics in eggs is reported. Ethyl acetate is used as extraction solvent, with satisfactory results, and simple automated clean-up is based on gel-permeation chromatography (GPC) . The target compounds are then analysed by liquid chromatography–electrospray ionization–tandem mass spectrometry. The method was validated in-house in accordance with Commission Decision 2002/657/EC. Trueness and precision were determined at four concentrations, and the mean errors obtained were <10 %, with relative standard deviations ranging from 3 to 18 %. For three non-authorized coccidiostatics (clopidol, ethopabate, and ronizadole), decision limit and detection capability were in the ranges 0.12–0.16 and 0.18–0.23 μg kg?1, respectively. The results obtained prove the suitability of this new analytical method for routine monitoring of these substances in eggs. 相似文献
19.
S. Borràs R. Companyó J. Guiteras J. Bosch M. Medina S. Termes 《Analytical and bioanalytical chemistry》2013,405(26):8475-8486
A rapid multiclass method that covers 50 antimicrobials from 13 different families in animal feeds was developed. Samples were extracted using a mixture of methanol, acetonitrile and a McIlvaine buffer combined with sonication. Feed extracts were simply diluted prior to injection, since the clean-up strategies that were tested, based on either solid-phase extraction or dispersive solid-phase extraction, were ineffective at minimizing matrix-related signal suppression/enhancement. Analysis was carried out by liquid chromatography coupled to tandem mass spectrometry using an electrospray ionization source operating in positive and negative modes. For the quantification, matrix-fortified standard calibration curves were used to compensate for matrix effects and losses in sample preparation. The method was validated in-house in pig, poultry and cattle feed matrices and showed satisfactory performance characteristics. Thus, the proposed approach was suitable for application in a routine high-throughput laboratory for the official control of feeds. Figure
Multiclass method for antimicrobial analysis in animal feeds. 相似文献
20.
Two carbonyl compounds, nabumetone and testosterone, were derivatized with pentafluorophenyl hydrazine (PFPH) and analyzed by atmospheric-pressure chemical-ionization mass spectrometry. The PFPH derivatives underwent dissociative electron capture in negative-ion APCI (ECAPCI) and gave intense [M–20]– ions in the mass spectra. In positive-ion APCI, the PFPH derivatives underwent efficient protonation and gave intense [M+H]+ ions in the mass spectra. In CID, the major product ions of the [M–20]– ions in ECAPCI corresponded to the partial moiety of PFPH. In contrast, the major product ions of [M+H]+ corresponded to the partial moiety of the analyte. By using selected reaction monitoring (SRM) detection, low pg of nabumetone (1 pg) and testosterone (7 pg) could be detected in both ECAPCI and positive-ion APCI. In comparison with the detection limits (SRM) of the underivatized analytes, use of the PFPH derivatives resulted in 2500-fold and 35-fold sensitivity enhancements for nabumetone and testosterone, respectively. The PFPH derivatives were applied to the analysis of nabumetone and testosterone in human plasma by both ECAPCI and positive-ion APCI and were found to enable detection of 0.1 ng mL–1 nabumetone in spiked plasma. For testosterone, endogenous testosterone in female plasma was detected in both ECAPCI and positive-ion APCI. 相似文献