首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 531 毫秒
1.
Plasma amyloid‐β peptide (Aβ) levels have been suggested as a biomarker candidate for detecting incipient AD. Aβ peptides are known to be sensitive to distinct preanalytical sample handling, which calls for standardised preanalytical procedures. We investigated serum and plasma samples of 19 patients with no clinical signs of dementia for different preanalytical sample handlings. Both serum and plasma were analysed by the one‐dimensional Aβ‐SDS‐PAGE/immunoblot, either immediately or after storage at room temperature for 24 and 48 h, respectively. The panel of Aβ1–37/38/39/40/42 and Aβ2–40 was evaluated. In both analytical matrices, sample storage led to a significant loss of measurable peptide levels. This effect was most pronounced during the first 24 h of storage and stronger in serum than in plasma. There were no significant differences between the distinct analysed Aβ peptide species regarding these results. The ratios of peptides (e.g. Aβ1–42/Aβ1–40 and Aβ1–42/Aβ1–38) displayed a higher stability under the influence of storage than each single peptide. In conclusion, plasma may be more appropriate than serum for analysing Aβ peptides for routine application. At least, the analysis should be done within 24 h and peptide ratios should be created to minimise artificial results.  相似文献   

2.
A high performance liquid chromatographic method for the measurement of bemoradan levels in plasma/serum is described. This method uses Varian's AASP (Varian Associates, Sunnyvale, CA, USA), a semi-automatic liquid/solid extraction sample preparation system. It requires only small volumes of plasma/serum samples (0.2-1 mL) and needs no organic solvent for sample preparation. The mean recovery of bemoradan at plasma or serum concentrations of 0.5-100 ng/mL is 82%. The assay has a detection limit of 0.5 ng/mL (when 1 mL of plasma/serum is used) and is linear in the concentration range 0.5-500 ng/mL.  相似文献   

3.
采用自动前处理LC/MS进行血浆中药物的快速分析   总被引:3,自引:0,他引:3  
药物研究的发展对高通量的样品处理分析提出了越来越高的要求,减少样品制备时间和分析时间是解决问题的关键。我们新近发展了一种具有在线稀释旁路和新的样品预处理柱的Shim-Pack MAYI-ODS自动柱切换HPLC和LC/MS系统,该系统无需样品前处理,可直接进样进行血浆、血清中的药物分析。本文利用自动样品前处理LC/MS系统,用ODS整体柱实现了血浆中药物的快速分析。包括样品预处理,整个分析仅需1.2min完成。  相似文献   

4.
Selected‐ion flow‐tube mass spectrometry (SIFT‐MS) is particularly suited for the analysis of volatile low molecular weight compounds. We have evaluated this technique for the assay of different alcohols in aqueous solutions, including blood plasma, and in particular whether the osmolality or sample volume affected vapourisation. Solutions of three different alcohols (methanol, ethanol and isopropanol) ranging from 0.005 to 50 mmol/L were prepared in deionised water (0 milliosmol), phosphate‐buffered saline (690 mOsm), isotonic saline (294 mOsm) and plasma (296 mOsm). The vapour above the sample (50 to 1000 µL) contained in air‐tight tubes at 37°C was aspirated into the instrument. The outputs for ethanol, methanol and isopropanol were linear over the concentration range and independent of the sample volume and relatively independent of the osmolar concentration. SIFT‐MS can reliably and accurately measure common alcohols in the headspace above aqueous solutions, including serum/plasma. This novel application of SIFT‐MS is easy to follow, requires no sample preparation and the wide dynamic range will facilitate measurement of alcohols present from normal metabolism as well as when taken in excess or in accidental poisoning. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

5.
The tremendous complexity of the serum and plasma proteome presents extreme analytical challenges in comprehensive analysis due to the wide dynamic range of protein concentrations. Therefore, robust sample preparation methods remain one of the important steps in the proteome characterization workflow. We present the results on a new column for the specific depletion of 14 high-abundant proteins from human serum and plasma and the subsequent reversed-phase fractionation of the flow-through proteins. Analysis of tryptic peptides was accomplished with microfluidic HPLC-Chip/MS system. Results indicate that high-abundant protein depletion combined with RP fractionation of plasma showed an improved dynamic range for proteomic analysis and enabled the identification of low-abundant plasma proteins.  相似文献   

6.
Cefuroxime is a second-generation cephalosporin used against different kinds of bacterial infections. To be able to optimize the dosing it is necessary to characterize the pharmacokinetics of cefuroxime which requires a selective and sensitive analytical method for cefuroxime in plasma or serum. A new rapid liquid chromatography/electrospray tandem mass spectrometry (LC/MS/MS) method, using cefotaxime as internal standard, was developed for analysis of cefuroxime in human serum. The work-up procedure consisted of protein precipitation with acetonitrile/cefotaxime, and after centrifugation the supernatant was dissolved in mobile phase. The sample was injected on a SB-CN column and the detection was performed using tandem mass spectrometry (MS/MS). The limit of quantification was determined to 0.025 microg/mL. The method was linear in the range 0.025-50 microg/mL with a coefficient of correlation >0.999. The limit of quantification and intra-day variability were found to be the same for plasma samples, which indicates that the method is valid for serum as well as plasma samples.  相似文献   

7.
The PhastSystem was used for three different analyses of human serum transferrins (Tf) by isoelectric focusing: (i) The distribution of iron over the two iron binding sites by separation of the four forms: apoTf, TfFeC, FeNTf and Fe2Tf by using less than 1 microL serum or plasma. The focused bands were visualized by immunoprecipitation and quantified by densitometry. (ii) The relative proportions of the diferic sialo-transferrin fractions in human sera or plasma were determined in a similar way. (iii) The presumed genetic variants can be determined. The methods are easy and reproducible and require much less sample (0.3 microL), time (1 h per run) and antibody (10 microL/sample) than crossed immunoelectrofocusing.  相似文献   

8.
A rapid, sensitive, and widely applicable method for the simultaneous quantitative analysis of 20 underivatized amino acids in different biological matrices, including serum, plasma, and tissue homogenates, using ultra high performance liquid chromatography with tandem mass spectrometry was developed and validated. Only 4 µL of serum, plasma, or tissue homogenate was extracted with 996 µL of solution (1.7 mM ammonium formate in 85% acetonitrile containing 0.1% formic acid) containing 100 ng/mL phenylalanine‐d5 as an internal standard without any further derivatization step. In addition, the matrix effects were small because a large volume of extraction solution was used. The total run time including reequilibration was 13 min. The results of linearity, accuracy, repeatability, precision, limits of detection, limits of quantification, and sample stability were sufficient to allow the measurement of the amino acids in different biological matrices. We conclude that our method is rapid, sensitive, and widely applicable and represents an improvement over other currently available technologies.  相似文献   

9.
A gradient elution high-performance liquid chromatographic method is described for the analysis of the beta-lactamase inhibitor tazobactam (YTR-830H) and a semi-synthetic parenteral penicillin, piperacillin, in human plasma, serum, bile and urine. The assay for plasma, serum and bile involves deproteinization with acetonitrile and the removal of lipids with dichloromethane; urine is diluted with buffer. Separation and quantitation are achieved using a mobile phase based on ion-suppression chromatography on a C18 reversed-phase column with ultraviolet detection at 220 nm. The limit of quantitation for both compounds is 1.0 microgram/ml in plasma, serum and bile using a 0.2-ml sample and 50.0 micrograms/ml in urine using a 0.1-ml sample. The method has been validated by preparing and analyzing a series of fortified samples (range 1.0-200 micrograms/ml for each compound in plasma, serum and bile and 50.0-10,000 micrograms/ml for each compound in urine). Excellent linearity, accuracy, precision and recovery were obtained. The method was not interfered with by other endogenous components, nor by other commonly administered antibiotics such as amoxicillin, mezlocillin, cefometazole and cefotaxime. The assay has been successfully applied to the analysis of samples from pharmacokinetic studies in man and animals.  相似文献   

10.
In most diseases, the clinical need for serum/plasma markers has never been so crucial, not only for diagnosis, but also for the selection of the most efficient therapies, as well as exclusion of ineffective or toxic treatment. Due to the high sample complexity, prefractionation is essential for exploring the deep proteome and finding specific markers.In this study, three different sample preparation methods (i.e., highly abundant protein precipitation, restricted access materials (RAM) combined with IMAC chromatography and peptide ligand affinity beads) were investigated in order to select the best fractionation step for further differential proteomic experiments focusing on the LMW proteome (MW inferior to 40,000 Da). Indeed, the aim was not to cover the entire plasma/serum proteome, but to enrich potentially interesting tissue leakage proteins. These three methods were evaluated on their reproducibility, on the SELDI-TOF-MS peptide/protein peaks generated after fractionation and on the information supplied.The studied methods appeared to give complementary information and presented good reproducibility (below 20%). Peptide ligand affinity beads were found to provide efficient depletion of HMW proteins and peak enrichment in protein/peptide profiles.  相似文献   

11.
Clotting and anticoagulation of blood samples may give rise to different metabolic profiles of serum and plasma samples, respectively. The anticoagulant used for blood plasma preparation may affect the resulting metabolic profile due to different mechanisms involved in anticoagulation by various agents, e.g. heparin, EDTA and citrate. In the present study, we looked into metabolite and other differences in matched serum and plasma samples and different plasma preparations by using untargeted UPLC-ESI-QTOF/MS profiling and multivariate data analysis (PCA and OPLS-DA). Metabolite differences between serum and plasma samples were mainly related to small peptides reflecting presence or absence of coagulation. Only subtle metabolite differences between the different plasma preparations were noticed, which were primarily related to ion suppression or enhancement caused by citrate and EDTA anticoagulants. For the first time, we also report that anticoagulant counter cation (Na+ or K+) in Na-citrate and K-EDTA plasma can make some metabolites more dominant in ESI-MS. Polymeric material residues originating from blood collection tubes for serum preparation were observed only in serum samples. Hypoxanthine and xanthine were found at higher levels in serum than in plasma samples, possibly due to release from the clot. Mass spectral features of sodium formate and potassium formate ion clusters were detected in citrate and EDTA plasma samples, respectively, originating from formate in mobile phase and Na+ (in Na-citrate tubes) and K+ (in K-EDTA tubes). Among the anticoagulants, heparin is recommended for plasma samples used for LC-ESI/MS-based metabolomics of hydrophilic compounds because no plasma interferences or matrix effects were noticed for this polarity range. Citrate and EDTA should be avoided since interferences and serious matrix effects were encountered on some co-eluting polar metabolites. Serum is recommended as a second choice and an alternative to plasma. In conclusion, heparin plasma or serum should be the order of best choice for LC-ESI/MS-based metabolomics research.  相似文献   

12.
Abstract

Theophylline is a drug used in the treatment of asthma. Its therapeutic value is dependent upon its concentration in the blood with levels greater than 20 mg/1 causing side affects, sometimes severe. Various people metabolize the drug at different rates, so a method for analyzing serum Theophylline is necessary. We have developed a rapid, quantitative HPLC method for the analysis of serum Theophylline. No pretreatment of the sample is necessary, the method uses direct injection of the serum sample onto a guard column.  相似文献   

13.
袁倚盛  赵飞浪 《色谱》1997,15(1):12-14
 用动物免疫法制备了免疫亲和柱纯化水溶性的沙丁胺醇血浆样品。琥珀酸酐交联沙丁胺醇和牛血清白蛋白获得抗原免疫家兔抗沙丁胺醇抗体——免疫球蛋白。琼脂糖Sepharose4B与抗体交联制成免疫球蛋白亲和柱。对高效液相色谱法测定中的一般提取方法和固相小柱提取法作了比较,后者具有内源性杂质干扰少的优点,是生物样品预处理的一种有效的方法。  相似文献   

14.
Serum/plasma concentrations of 5‐aminolaevulinic acid (ALA) and porphobilinogen (PBG) are elevated in patients with acute hepatic porphyrias, especially during acute attacks. Current assays require lengthy sample pre‐treatment and derivatization steps. We report here a rapid, sensitive and specific hydrophilic interaction liquid chromatography–tandem mass spectrometry method for the direct and simultaneous quantitation of ALA and PBG in serum or plasma following simple protein precipitation with acetonitrile and centrifugation prior to injection. ALA and PBG were detected using selected reaction monitoring mode, following positive atmospheric pressure chemical ionization. Calibration was linear from 0.05 to 50 µmol/L for ALA and PBG. For both analytes, imprecision (relative standard deviation) was <13% and accuracy (percentage nominal concentrations) was between 92 and 107%. The method was successfully applied to the measurement of ALA and PBG in serum or plasma samples for the screening, biochemical diagnosis and treatment monitoring of patients with acute hepatic porphyrias. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

15.
《Analytical letters》2012,45(1-3):483-502
Blood studies for clinical screening/analysis are geared toward point of care testing. Flow based techniques have expanded their applications with unique approaches that may be adaptable for use as alternative disease screening/diagnosis. Many newly developed systems for solution based chemical analysis can be easily adapted for use with plasma and serum. However, cell and intracellular analyses are different. Blood cell analyses require a particular way of sample introduction and detection. This review emphasizes the applications of flow based techniques, especially those that were coupled with FI/SI, in clinical studies through analysis of red blood cells and their intracellular substances.  相似文献   

16.
Promising profiling techniques based on new material/solid phase extraction for capturing “molecular signatures” from body fluids are being coupled to MALDI-TOF-MS. Sample preparation significantly influences spectrum quality in this ionization method. Mesoporous silica beads (MSB), by the means of nano-sized porous channels with high surface area, enable harvesting of peptides from plasma and serum excluding large size proteins. We have investigated the morphology of a sample slurry, developed as a new tool for plasma peptides enrichment based on mesoporous materials. Our study highlights a correlation between crystals morphology and enhanced performances in MALDI-TOF-MS analysis. This is the first report which correlates the increase in signal intensity with crystal formation in samples preparations which make use of various kinds of slurries for the analysis of samples clinically relevant like human plasma.  相似文献   

17.
A simple, fast and cost‐effective method was developed and validated for the determination of levetiracetam (LEV) in plasma/serum of patients using high performance liquid chromatography (HPLC) with ultraviolet detection. The stability of LEV plasma/serum samples over time and in different blood collection tubes was evaluated. Serum/plasma samples were deproteinized by methanol spiked with the internal standard, gabapentin. HPLC was carried out on a Venusil XBP C18, 250 × 4.6 mm, 5 μm column, at a flow rate of 1.0 mL/min and with mobile phase consisting of 50 mm potassium dihydrogen phosphate–acetonitrile at a pH of 5.5. The UV detector was set at 205 nm and 10 μL was injected. Total runtime was 15 min. Calibration curves were linear (correlation coefficient = 0.999) over a concentration range of 1–60 μg/mL. Relative standard deviation values for both the inter‐day and intra‐day precision and accuracy were <5% for the concentration range. The influence of different collection tubes and the effect of time on the stability of LEV was investigated. These factors may cause inaccuracies owing to drug–protein binding and interference in the matrix. This method is simple, fast, cost‐effective, reliable and accurate with minimal sample preparation for daily routine use in therapeutic drug monitoring.  相似文献   

18.
Methylmalonic acid (MMA) is a functional biomarker of vitamin B12 deficiency. Measurement of plasma MMA is challenging due to its small molecular weight and hydrophilic nature. Several liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods have been developed for measuring plasma MMA. However, these methods involve lengthy sample preparation, long chromatographic run time, inadequate sensitivity, or interference from succinic acid (SA). Here we report a novel LC-MS/MS method for quantitation of underivatized MMA in serum or heparinized plasma with high sensitivity and selectivity. Sample preparation involved only strong anion exchange solid phase extraction. The extract was purified by online turbulent flow and analyzed on an Organic Acids column. MS/MS analysis was performed in negative electrospray mode, and the analytical time was 6 min. The use of ion ratio confirmation in combination with chromatographic resolution from SA greatly enhanced the selectivity. No interference was observed. This method was linear from 26.2 to 26,010.0 nM with an accuracy of 98-111 %. Total coefficient of variation was less than 4.6 % for three concentration levels tested. Comparison with a reference laboratory LC-MS/MS method using leftover patient serum specimens (n = 48) showed a mean bias of -2.3 nM (-0.61 %) with a Deming regression slope of 1.016, intercept of -6.6 nM, standard error of estimate of 25.3 nM, and a correlation coefficient of 0.9945. In conclusion, this LC-MS/MS method offers highly sensitive and selective quantitation of MMA in serum and plasma with simple sample preparation.  相似文献   

19.
This paper describes an analytical method for the determination of ceruloplasmin (Cp) in human serum. The method uses immunoaffinity chromatography and size-exclusion chromatography (SEC) to “purify” the serum sample prior to analysis of 63Cu and 65Cu by inductively-coupled plasma mass spectrometry (ICPMS). By removing the six most abundant proteins from serum with immunoaffinity chromatography and by using SEC to separate Cu bound by Cp from any free Cu that might be present in the serum sample, we demonstrated that SEC-ICPMS can accurately and reproducibly measure Cp in the ERM DA470 reference serum. Cp identification is based on retention time match of the unknown in the serum sample with the Cp external standard and the presence of 63Cu and 65Cu at a ratio of 2.2±0.1. This method was used to analyze a reference serum certified for Cp, 47 serum samples from four different diseases and a set of normal controls. The reference serum and a serum sample from a patient with myocardial infarction, as well as a Cp standard, were also analyzed by electrospray mass spectrometry to confirm the presence of Cp in the SEC fraction known to contain 63Cu.  相似文献   

20.
Human blood plasma and serum pose significant challenges to implanted devices because of highly unfavorable nonspecific protein adsorption on the surface. In this work, we introduce an improved two-step method to immobilize initiator thiols on a gold substrate for the surface-initiated atom-transfer radical polymerization (SI-ATRP) of hydroxypropyl methacrylate (HPMA). We investigate protein adsorption from a single-protein solution, diluted (10%) and undiluted (100%) human blood plasma, and serum on the poly(HPMA) brushes with different film thicknesses using surface plasmon resonance (SPR) sensors. SPR results show a correlation between antifouling properties and film thickness; that is, the poly(HPMA) brushes exhibit high protein resistance at medium film thicknesses of ~25-40 nm (e.g. <0.3 ng/cm(2) for single-protein adsorption and 10% human blood plasma and serum, ~24.5 ng/cm(2) for 100% human serum, and ~52.8 ng/cm(2) for 100% human plasma at a thickness of ~29 nm). With an optimal film thickness and surface roughness, the poly(HPMA) brush also demonstrates its high resistance to fibroblast adhesion. This work provides an alternative surface polymerization approach to preparing effective antifouling poly(HPMA) materials for potential applications in blood-contacting medical devices.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号