首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive, efficient, high throughput, direct injection bioanalytical method based on a single column and high-performance liquid chromatography (HPLC) with tandem mass spectrometry (MS/MS) was developed for pharmacokinetic analysis of early drug discovery compounds in plasma samples. After mixing with a working solution containing an internal standard each plasma sample was directly injected into a polymer-coated mixed-function column for sample cleanup, enrichment and chromatographic separation. The stationary phase incorporates hydrophilic polyoxyethylene groups and hydrophobic groups to the polymer-coated silica. This allows proteins and macromolecules to pass through the column due to restricted access to the surface of the packing while retaining the drug molecules on the bonded hydrophobic phase. The analytes retained in the column with a largely aqueous liquid mobile phase were then chemically separated by switching to a strong organic mobile phase. The column effluent was diverted from waste to the mass spectrometer for analyte detection. Within 200 plasma sample injections the response ratio (analyte vs. internal standard, %CV = 4.6) and the retention times for analyte and internal standard were found consistent and no column deterioration was observed. The recoveries of test compound in various plasma samples were greater than 90%. The total analysis time was 相似文献   

2.
An ultrafast bioanalytical method using monolithic column high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) was evaluated for the simultaneous determination of a drug discovery compound and its metabolite in plasma. Baseline separation of the two compounds was achieved with run times of 24 or 30 s under isocratic or gradient conditions, respectively. The monolithic column HPLC/MS/MS system offers shorter chromatographic run times by increasing flow rate without sacrificing separation power for the drug candidate and its biotransformation product (metabolite). In this work, the necessity for adequate chromatographic resolution was demonstrated because the quantitative determination of the drug-related metabolism product was otherwise hampered by interference from the dosed drug compound. The chromatographic performance of a monolithic silica rod column as a function of HPLC flow rates was investigated with a mixture of the drug component and its synthetic metabolite. The assay reliability of the monolithic column HPLC/MS/MS system was checked for matrix ionization suppression using the post-column infusion technique. The proposed methods were successfully applied to the analysis of study rat plasma samples for the simultaneous quantitation of both the dosed drug and its metabolite. The analytical results obtained by the proposed monolithic column methods and the 'standard' silica particle-packed HPLC column method were in good agreement, within 10% error.  相似文献   

3.
A sensitive and high-throughput LC-MS-MS method was developed for simultaneous determination of nitrendipine (NIT) and its major metabolite, dehydronitrendipine (DNIT) in human plasma using nifedipine as the internal standard. Plasma samples were prepared based on a simple liquid-liquid extraction. The extracted samples were analyzed on a Zorbax SB C(18) column interfaced with a triple quadrupole tandem mass spectrometer. Positive atmospheric pressure chemical ionization was employed as the ionization source. The analytes were detected by use of selected reaction monitoring mode. Standard curves were linear (r > or = 0.995) over the concentration range of 0.4-40 ng/mL for NIT and 0.2-20 ng/mL for DNIT. The intra- and inter-run precision was measured to be below 8.5% for NIT and DNIT. The inter-run accuracy was less than 4% for the analytes. The overall extraction recoveries of NIT and DNIT were determined to be about 75% and 78% on average, respectively. The chromatographic run time was approximately 3 min. More than 120 samples could be assayed daily with this method, including sample preparation, data acquisition and processing. The method developed was successfully used to investigate plasma concentrations of NIT and DNIT in a pharmacokinetic study of volunteers who received NIT orally.  相似文献   

4.
A confirmatory method has been developed and validated for the determination of chlormadinone acetate (CMA), megestrol acetate (MGA), melengestrol acetate (MLA) and medroxyprogesterone acetate (MPA) in bovine and porcine plasma. Analytes are extracted from plasma samples using matrix-assisted liquid-liquid extraction (LLE) on Extrelut NT columns followed by C18 solid-phase extraction (SPE). Analytes were analysed using liquid chromatography-tandem mass spectrometry (LC-MS/MS), and quantification was performed using matrix-matched calibration standards in combination with deuterated internal standards. In accordance with Commission Decision 2002/657/EC, two ion transitions were monitored for each analyte. Decision limits (CCalpha) were estimated by analysing 20 blank plasma samples and ranged from 0.1 to 0.2 ng mL(-1). Detection capabilities (CCbeta) were estimated using 20 plasma samples fortified at 0.5 ng mL(-1) and were <0.5 ng mL(-1). In the range 0.5-2 ng mL(-1), the mean intra-laboratory reproducibility of the analytes ranged from 6 to 18% (%R.S.D.). Analytes were shown to be stable in fortified plasma samples for >8 months when stored at -20 degrees C.  相似文献   

5.
6.
Yi X  Han L  Yang H  Fan X  Zhu J  Guo D 《色谱》2010,28(7):649-653
建立了液相色谱-串联质谱分析洋槐蜜、荆条蜜、蜂巢蜜、杂花蜜、野蜂蜜中杀虫脒及其代谢产物残留的方法。样品经氢氧化钠水溶液稀释溶解后,采用Waters Oasis HLB固相萃取柱净化。样品提取液经Agilent XDB-C18色谱柱分离,以0.1%甲酸水溶液和乙腈为流动相进行梯度洗脱。以电喷雾正离子(ESI+)模式电离,多反应监测(MRM)模式检测,基质匹配标准溶液外标法定量。杀虫脒及其代谢产物(4-氯邻甲苯胺)在2.5~250 μg/L范围内呈线性相关,相关系数(r)均大于0.999;定量限(S/N>10)为5 μg/kg,检出限(S/N>3)为2.5 μg/kg。各种蜂蜜基质样品在5、10和20 μg/kg添加水平时,杀虫脒及其代谢产物的回收率范围分别为75.8%~113.8%和85.6%~114.3%,相对标准偏差(RSD)分别为4.8%~10.2%和4.7%~9.1%,可以满足蜂蜜中杀虫脒及其代谢产物残留量的检测需要。  相似文献   

7.
A sensitive and selective liquid chromatographic–electrospray ionization mass spectrometric method for the simultaneous determination of propentofylline and enantiomers of its active metabolite M1 in rat serum, cortex and hippocampus was developed and validated according to GLP procedures. Sample preparations were carried out by liquid–liquid extraction using diethyl ether after the addition of the internal standard (pentoxifylline). The dried residue was reconstituted in mobile phase and injected onto a Chiralpak AD column (10 µm, 250 × 4.6 mm i.d.). The limit of quantification for propentofylline in serum, cortex and hippocampus was set at 0.25 ng/mL and for enantiomers of its metabolite M1 at 1.25 ng/mL. The established LC/ESI‐MS/MS method has been successfully applied to an initial pharmacokinetic study of propentofylline and also to assessment of distribution of parent drug and enantiomers of its pharmacologically active metabolite M1 to cortex and hippocampus after intravenous administration of propentofylline to rats at a dose of 5 mg/kg. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

8.
A new method for the fast simultaneous quantification of fluticasone propionate and salmeterol from plasma samples by liquid chromatography–tandem mass spectrometry, with adequate sensitivity for pharmacokinetic applications, was developed and validated. The chromatographic separation and mass‐spectrometric parameters were optimized for the retention and detection of the two compounds, despite quite different structures and properties. Two columns connected in series were used, cation‐exchange (Zorbax 300‐SCX, 5 cm × 2.1 mm, 5 µm) and octadecyl (Discovery HSC18, 10 cm × 2.1 mm, 5 µm). The mass‐spectrometric interface was operated in negative electrospray ionization mode; high sensitivity and lesser matrix effects were obtained, permitting smaller consumption of plasma. The sample preparation was based on supported liquid–liquid extraction in 96‐well format plates that provided clean samples with a simplified procedure that was suitable for automation. The method was validated according to regulatory guidelines, by assessing lower limits of quantification, selectivity, linearity, accuracy, precision, extraction recoveries and matrix effects. A comparison with two other methods for the separate determination of fluticasone propionate and salmeterol in plasma samples, previously developed by our group, is presented. The statistical evaluation of the results obtained with the three methods on a set of unknown samples from treated patients demonstrated good correlation (R2 0.987 for fluticasone propionate and 0.967 for salmeterol). Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

9.
建立了大鼠灌胃麻杏石甘汤后血浆中苦杏仁苷、野黑樱苷的定性及定量方法。样品经液液萃取净化处理,定性采用超高效液相色谱-串联四极杆飞行时间质谱仪(UPLC-QTOF-MS/MS),经Shim-pack XR-ODS Ⅲ色谱柱(75 mm×2.0 mm,1.6 μm)分离,定量采用超高效液相色谱-串联三重四极杆质谱仪(UPLC-Q-TRAP-MS),经Agilent C18色谱柱(50 mm×2.1 mm,1.7 μm)分离,电喷雾负离子化(ESI)及MRM模式测定,流动相均为乙腈-0.1%(v/v)甲酸水溶液。结果显示苦杏仁苷、野黑樱苷在相应浓度范围内线性关系良好(相关系数分别为0.9990、0.9970),精密度(RSD)小于9.20%,回收率为82.33%~95.25%,检出限(LOD)约为0.50 ng/mL。本方法快速简便,为血浆样品中苦杏仁苷、野黑樱苷的定性和定量分析提供良好参考。  相似文献   

10.
An enantioselective method for the determination of fluoxetine (a selective serotonin reuptake inhibitor) and its pharmacologically active metabolite norfluoxetine has been developed for raw and treated wastewater samples. The stable isotope-labeled fluoxetine and norfluoxetine were used in an extended way for extraction recovery calculations at trace level concentrations in wastewater. Wastewater samples were enriched by solid phase extraction (SPE) with Evolute CX-50 extraction cartridges. The obtained extraction recoveries ranged between 65 and 82% in raw and treated wastewater at a trace level concentration of 50 pM (15-16 ng L−1). The target compounds were identified by the use of chiral liquid chromatography tandem mass spectrometry (LC-MS/MS) in selected reaction monitoring (SRM) mode. The enantiomers were successfully resolved on a chiral α1-acid glycoprotein column (chiral AGP) with acetonitrile and 10 mM ammonium acetate buffer at pH 4.4 (3/97, v/v) as the mobile phase. The effects of pH, amount of organic modifier and buffer concentration in the mobile phase were investigated on the enantiomeric resolution (Rs) of the target compounds. Enantiomeric Rs-values above 2.0 (1.03 RSD%, n = 3) were achieved for the enantiomers of fluoxetine and norfluoxetine in all mobile phases investigated. The method was validated by assessing parameters such as cross-contamination and carryover during SPE and during LC analysis. Cross-talk effects were examined during the detection of the analytes in SRM mode. In addition, the isotopic purity of fluoxetine-d5 and norfluoxetine-d5 were assessed to exclude the possibility of self-contamination. The interassay precision of the chromatographic separation was excellent, with relative standard deviations (RSD) equal to or lower than 0.56 and 0.81% in raw and treated wastewaters, respectively. The method detection and quantification limits (respectively, MDL and MQL) were determined by the use of fluoxetine-d5 and norfluoxetine-d5. The MQL for the single enantiomers ranged from 12 to 14 pM (3.6-4.3 ng L−1) in raw wastewater and from 3 to 4 pM (0.9-1 ng L−1) in treated wastewater. The developed method has been employed for the quantification of (R)-fluoxetine, (S)-fluoxetine and the enantiomers of norfluoxetine in raw and treated wastewater samples to be presented in Part II of this study.  相似文献   

11.
Guo N  Hu Z  Fan X  Zheng J  Zhang D  Xu T  Yu T  Wang Y  Li H 《Molecules (Basel, Switzerland)》2012,17(4):4733-4754
Salidroside and its aglycone p-tyrosol are two major phenols in the genus Rhodiola and have been confirmed to possess various pharmacological properties. In our present study, p-tyrosol was identified as the deglycosylation metabolite of salidroside after intravenous (i.v.) administration to rats at a dose of 50 mg/kg, but was not detectable after intragastric gavage (i.g.) administration through HPLC-photodiode array detection (PDA) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis. Next, an accurate and precise LC-MS/MS method was developed to quantitatively determine salidroside and p-tyrosol in rat plasma samples. Samples were analyzed by LC-MS/MS on a reverse-phase xTerra MS C18 column which was equilibrated and eluted with an isocratic mixture of acetonitrile-water (1:9, v/v) at a flow rate of 0.3 mL/min. The analytes were monitored by multiple reaction monitoring (MRM) under the negative electrospray ionization mode. The precursor/product transitions (m/z) were 299.0 → 118.8 for salidroside, 137.0 → 118.9 for p-tyrosol and 150.1 → 106.9 for the internal standard (IS), paracetamol, respectively. The calibration curve was linear over the concentration ranges of 50-2,000 ng/mL for salidroside and 20-200 ng/mL for p-tyrosol. The inter- and intra-day accuracy and precision were within ± 15%. The method has been successfully applied to the pharmacokinetic study and the oral bioavailability was calculated.  相似文献   

12.
建立了超高效液相色谱-串联质谱(UPLC-MS/MS)快速测定鸡蛋中氟虫腈及其代谢物的方法。在2 g鸡蛋中加入2 mL水后,用4 mL乙腈提取,然后加入1 g NaCl,于4℃以9000 r/min离心10 min,稀释后过有机膜。采用C18色谱柱(100 mm×2.1 mm,1.7 μm)分离,在电喷雾电离源、负离子模式下进行多反应监测(MRM)采集。结果表明,氟虫腈及其代谢物在3个添加水平下的回收率为77.4%~112.1%,相对标准偏差为4.0%~13.6%,检出限为0.10~0.43 μg/kg。该法简单、高效,可用于实际样品检测。  相似文献   

13.
Jiang X  Dong J  Wang F  Feng S  Ye M  Zou H 《Electrophoresis》2008,29(8):1612-1618
An automated nano-LC-MS/MS platform without trap column was established, which only used a 20 cm lauryl methacrylate-ethylene dimethacrylate (LMA-EDMA) monolithic capillary column to allow preconcentration and separation of peptides. The monolithic column had the advantages of good permeability and low backpressure resulting in higher flow rates for capillary columns. Tryptic digests of bovine albumin and yeast protein extract were tested using the monolithic column system. High proteomic coverage using this approach were demonstrated in this study. Furthermore, peptide samples extracted from mouse liver were separated by using the monolithic column system combined with size-exclusion chromatography prefractionation. This monolithic column system might be a promising alternative for the automated system previously using a trap column for routine proteome and peptide profiling analysis.  相似文献   

14.
Methoxyphenamine (o-methoxy-N,alpha-dimethylphenethylamine, Orthoxine) used in earlier times as a bronchodilator is prohibited in sports according to the regulations of the World Anti-Doping Agency (WADA). The drug and several of its metabolites are commonly analysed in doping control screening assays using gas chromatography-mass spectrometry requiring extraction from urine specimens. A complementary method employing liquid chromatography-atmospheric pressure chemical ionisation-tandem mass spectrometry and direct injection of urine aliquots was developed, which provided a fast and sensitive alternative to confirm the presence of the prohibited compound and degradation products in sports drug testing samples. In particular, the chromatographic separation of the active drug from isomeric compounds such as the designer drug p-methoxymetamphetamine (PMMA) was of particular interest to unambiguously identify the applied substance and was accomplished using a C6-phenyl reverse-phase column with isocratic elution. The established procedure was validated for methoxyphenamine with regard to specificity, limit of detection (0.7 ng mL(-1)), intraday- and interday precision (2.5-5.8% and 10.8-16.2%, respectively) and its applicability was demonstrated with an authentic doping control sample which tested positive for the prohibited compound early in 2008.  相似文献   

15.
气相色谱-质谱/质谱法检测蔬菜中的毒死蜱及其代谢物   总被引:6,自引:0,他引:6  
凌云  王菡  雍炜  储晓刚 《色谱》2009,27(1):78-81
建立了蔬菜中毒死蜱及其代谢物3,5,6-三氯-2-羟基吡啶(3,5,6-trichloro-2-pyridinol,TCP)的气相色谱-质谱/质谱分析方法。蔬菜样品采用丙酮提取,浓缩后TCP用N-甲基-N-叔丁基二甲基硅基三氟乙酰胺(MTBSTFA)衍生,再经氟罗里硅土固相萃取柱净化。采用三重四极杆质谱电子轰击多反应监测(MRM)模式测定。采用内标法对毒死蜱定量,方法的检出限为1 μg/kg,加标回收率为75.57%~106.41%,相对标准偏差(RSD)为8.33%~17.58%。采用外标法对TCP定量,方法的检出限为0.5 μg/kg,加标回收率为69.11%~108.43%,RSD为5.20%~19.42%。在2~100 μg/L范围内,两种被测物的线性关系良好(r>0.99)。该方法可用于蔬菜中毒死蜱及其代谢物的检测。  相似文献   

16.
In the HPLC of basic drugs and metabolites, good efficiency and peak shape can often be attained using strong cation‐exchange packings with isocratic 100% methanol eluents containing an ionic modifier at an appropriate pH* and ionic strength. Solvent extracts can be analysed directly, and use of ammonium acetate as modifier facilitates the use of atmospheric pressure chemical ionization (APCI)–tandem mass spectrometry, selected reaction monitoring mode. For the analysis of amisulpride and of metamfetamine/amfetamine in plasma (200 µL) after single oral doses in man, a column packed with Waters Spherisorb S5SCX (5 µm average particle size, 100 × 2.1 mm i.d.) was used with methanolic ammonium acetate (40 mmol/L, pH* 6.0, flow rate 0.5 mL/min) as eluent (35°C). Deuterated internal standards were used for each analyte. Detection was by positive‐mode APCI. Responses for all analytes were linear over the calibration ranges. Intra‐assay precision (RSD) was 2–18%, and inter‐assay precision was 2–12%. The limit of detection was 0.5 µg/L for all analytes. No significant matrix effects or isobaric interferences were noted. The total analysis time was 7 min. Similar methodology can be applied to a wide range of basic analytes using MS/MS detection. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

17.
A reliable method for the confirmation of the synthetic hormone stanozolol and its major metabolite, 16beta-hydroxystanozolol, in bovine urine by liquid chromatography coupled with tandem mass spectrometry has been developed. [2H3]Stanozolol was used as internal standard. Sample preparation involved enzymatic hydrolysis, liquid-liquid extraction and purification on an amino solid-phase extraction column. The analytes were ionized using atmospheric pressure chemical ionization with a heated nebulizer interface operating in the positive ion mode, where only the protonated molecules, [M+H]+, at m/z 329 and m/z 345, for stanozolol and 16beta-hydroxystanozolol, respectively, were generated. These served as precursor ions for collision-induced dissociation and three diagnostic product ions for each analyte were identified for the unambiguous hormone confirmation by selected reaction monitoring liquid chromatography-tandem mass spectrometry. The accuracy ranged from 19.7 to 14.9% and from 18.9 to 13.2% for stanozolol and 16beta-hydroxystanozolol, respectively. The precision ranged from 12.4 to 2.4% and from 13.1 to 1.8% for stanozolol and 16beta-hydroxystanozolol, respectively. The limit of quantification of the method was 1 ng/ml in the bovine urine for both stanozolol and 16beta-hydroxystanozolol. The developed method fulfils the European Union requirements for confirmatory methods.  相似文献   

18.
A detailed procedure for the analysis of four beta-blockers, acebutolol, labetalol, metoprolol and propranolol, in human plasma by high-performance liquid chromatography (LC)-tandem mass spectrometry (MS-MS) using an MSpak GF column, which enables direct injection of crude plasma samples, is presented. Protein and/or macromolecule matrix compounds were eluted first from the column, while the drugs were retained on the polymer stationary phase of the MSpak GF column. The analytes retained on the column were then eluted into an acetonitrile-rich mobile phase using a gradient separation technique. All drugs showed base peak ions due to [M + H]+ ions by LC-MS with positive ion electrospray ionization, and the product ions were produced from each [M + H]+ ion by LC-MS-MS. Quantification was performed by selected reaction monitoring. The recoveries of the four beta-blockers spiked into plasma were 73.5-89.9%. The regression equations for all compounds showed excellent linearity in the range 10-1000 ng/mL of plasma, with the exception of propranolol (10-800 ng/mL). The limits of detection and quantification for each drug were 1-3 and 10 ng/mL, respectively, of plasma. The intra- and inter-day coefficients of variation for all drugs in plasma were not greater than 10.9%.  相似文献   

19.
A liquid chromatography-tandem mass spectrometric (LC-MS-MS) method was developed for the determination of the neurotropic-musculotropic spasmolytic agent denaverine and five of its metabolites in urine. In a first step beta-glucuronidase was used to cleave glucuronides in the human urine. After that samples containing denaverine and its phase I metabolites were extracted and cleaned up using an automated solid phase extraction method. An external calibration was used. The analytes were measured employing the multiple reaction-monitoring mode (MRM). The linear dynamic range for denaverine and its five metabolites determination was demonstrated from lower limit of quantification (8.0 ng/ml) to at least 500 ng/ml. The presented method is suitable for pharmacokinetic or toxicokinetic studies. With the help of reference substances some additional potential metabolites could be excluded in the urine samples. To look for additional unknown metabolites the LC-MS-MS system operated on one hand in the precursor ion mode using typical product ions of denaverine and of its metabolites and on the other hand in the product ion mode using postulated protonated molecules [M+H](+). With the help of the chromatographic behaviour and typical fragment ions of the unknown metabolites it was possible to elucidate their structures. Nine until now unknown metabolites were found in the urine samples. However, without reference substances a quantification of these analytes was not possible.  相似文献   

20.
A liquid chromatography-tandem mass spectrometric (LC-MS-MS) method was developed and validated for the determination of the anticholinergic and antimuscarinc drug propiverine and eight of its metabolites in serum, urine, faeces and different tissue samples of rats. Samples containing propiverine and its metabolites in serum and urine and in the supernatants of faeces and tissue homogenates were extracted and cleaned up using an automated solid phase extraction (SPE) method. An external calibration was used. The analytes were measured employing the multiple reaction monitoring mode (MRM). A sufficient response over the range of 10-1000 ng/ml was demonstrated. The lower limit of quantification of the nine substances was 10 ng/ml. The presented method is suitable for pharmacokinetic or toxicokinetic studies. To look for additional unknown metabolites, the LC-MS-MS system operated in the precursor ion mode using typical product ions of propiverine and of its metabolites. With the help of the chromatographic behaviour and typical fragment ions of the unknown metabolites, it was possible to elucidate their structure. Five until now unknown metabolites were found in the urine and faeces samples. However, without reference substances, a quantification of these analytes was not possible.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏