首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An autoclave reactor was modified to perform simultaneously high energy resolution fluorescence detected X-ray absorption spectroscopy (HERFD XAS) and attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy measurements without altering the reactor design. This operando cell allows one to follow changes in the electronic and geometric structure of the catalyst with HERFD XAS and relate them to the simultaneously detected activity and reaction species with ATR-FTIR formed during the reaction in the liquid phase. The capability of the cell is demonstrated by two studies. The first shows the reduction of Au/CeO(2) precursors in different solvents. The second shows that mainly Au(0) is present in the hydrogenation of nitrobenzene over Au/CeO(2).  相似文献   

2.
In situ X-ray absorption spectroscopy (XAS) at the Pt L(3) edge is a useful probe for Pt-O interactions at polymer electrolyte membrane fuel cell (PEMFC) cathodes. We show that XAS using the high energy resolution fluorescence detection (HERFD) mode, applied to a well-defined monolayer Pt/Rh(111) sample where the bulk penetrating hard X-rays probe only surface Pt atoms, provides a unique sensitivity to structure and chemical bonding at the Pt-electrolyte interface. Ab initio multiple-scattering calculations using the FEFF code and complementary extended X-ray absorption fine structure (EXAFS) results indicate that the commonly observed large increase of the white-line at high electrochemical potentials on PEMFC cathodes originates from platinum oxide formation, whereas previously proposed chemisorbed oxygen-containing species merely give rise to subtle spectral changes.  相似文献   

3.
The electronic structure of UV‐ and UVI‐containing uranates NaUO3 and Pb3UO6 was studied by using an advanced technique, namely X‐ray absorption spectroscopy (XAS) in high‐energy‐resolution fluorescence‐detection (HERFD) mode. Due to a significant reduction in core–hole lifetime broadening, the crystal‐field splittings of the 5f shell were probed directly in HERFD‐XAS spectra collected at the U 3d edge, which is not possible by using conventional XAS. In addition, the charge‐transfer satellites that result from U 5f–O 2p hybridization were clearly resolved. The crystal‐field parameters, 5f occupancy, and degree of covalency of the chemical bonding in these uranates were estimated by using the Anderson impurity model by calculating the U 3d HERFD‐XAS, conventional XAS, core‐to‐core (U 4f–3d transitions) resonant inelastic X‐ray scattering (RIXS), and U 4f X‐ray photoelectron spectra. The crystal field was found to be strong in these systems and the 5f occupancy was determined to be 1.32 and 0.84 electrons in the ground state for NaUO3 and Pb3UO6, respectively, which indicates a significant covalent character for these compounds.  相似文献   

4.
Recent studies, based on X-ray absorption spectroscopy (XAS) and X-ray Raman scattering (XRS), have shown that the hydrogen bond network in liquid water consists mainly of water molecules with only two strong hydrogen bonds. Since this result is controversial, it is important to demonstrate the reliability of the experimental data, which is the purpose of this paper. Here we compare X-ray absorption spectra of liquid water recorded with five very different techniques sensitive to the local environment of the absorbing molecule. Overall, the spectra obtained with photon detection show a very close similarity and even the observable minor differences can be understood. The comparison demonstrates that XAS and XRS can indeed be applied reliably to study the local bonding of the water molecule and thus to reveal the hydrogen bond situation in bulk water.  相似文献   

5.
We utilized X-ray absorption spectroscopy (XAS) and X-ray Raman scattering (XRS) in order to study the ion solvation effect on the bulk hydrogen bonding structure of water. The fine structures in the X-ray absorption spectra are sensitive to the local environment of the probed water molecule related to the hydrogen bond length and angles. By varying the concentration of ions, we can distinguish between contributions from water in the bulk and in the first solvation sphere. We show that the hydrogen bond network in bulk water, in terms of forming and breaking hydrogen bonds as detected by XAS/XRS, remains unchanged, and only the water molecules in the close vicinity to the ions are affected.  相似文献   

6.
The reaction of oxygen with rhodium complexes containing N-heterocyclic carbenes was found to give dioxygen complexes with rare square planar geometries and unusually short O-O bond lengths. Analysis of the bonding in these complexes by Rh L-edge X-ray absorption spectroscopy (XAS), Raman spectroscopy, and DFT calculations provides evidence for a bonding model in which singlet oxygen is bound to a Rh(I) d8 metal complex, rather than the more common Rh(III) d6 peroxo species with octahedral geometry and O-O bond lengths in the 1.4-1.5 A range.  相似文献   

7.
Element specificity is one of the key factors underlying the widespread use and acceptance of X-ray absorption spectroscopy (XAS) as a research tool in the environmental and geo-sciences. Independent of physical state (solid, liquid, gas), XAS analyses of metal(loid)s in complex environmental matrices over the past two decades have provided important information about speciation at environmentally relevant interfaces (e.g. solid–liquid) as well as in different media: plant tissues, rhizosphere, soils, sediments, ores, mineral process tailings, etc. Limited sample preparation requirements, the concomitant ability to preserve original physical and chemical states, and independence from crystallinity add to the advantages of using XAS in environmental investigations. Interpretations of XAS data are founded on sound physical and statistical models that can be applied to spectra of reference materials and mixed phases, respectively. For spectra collected directly from environmental matrices, abstract factor analysis and linear combination fitting provide the means to ascertain chemical, bonding, and crystalline states, and to extract quantitative information about their distribution within the data set. Through advances in optics, detectors, and data processing, X-ray fluorescence microprobes capable of focusing X-rays to micro- and nano-meter size have become competitive research venues for resolving the complexity of environmental samples at their inherent scale. The application of μ-XANES imaging, a new combinatorial approach of X-ray fluorescence spectrometry and XANES spectroscopy at the micron scale, is one of the latest technological advances allowing for lateral resolution of chemical states over wide areas due to vastly improved data processing and detector technology.  相似文献   

8.
9.
In situ and operando techniques providing information regarding adsorbate bonding and atomic arrangements on the electrode surface along with pure electrochemical measurements are needed to more fully understand the detailed mechanism of electrocatalytic reactions on high surface areas/nanoparticle electrocatalysts. X-ray adsorption spectroscopy (XAS) is a powerful tool to interrogate the electronic structure and local coordination environment of such electrocatalysts under working conditions, but it should be acknowledged that standard XAS methods are not intrinsically surface sensitive. This review will present recent in situ XAS studies on single-atom, metal, and metal oxide electrocatalysts, highlighting the approaches taken to achieve surface sensitivity by careful designing of the sample under investigation.  相似文献   

10.
Hydrogen bonding (H-bonding) is generally thought to play an important role in tuning the electronic structure and reactivity of metal-sulfur sites in proteins. To develop a quantitative understanding of this effect, S K-edge X-ray absorption spectroscopy (XAS) has been employed to directly probe ligand-metal bond covalency, where it has been found that protein active sites are significantly less covalent than their related model complexes. Sulfur K-edge XAS data are reported here on a series of P450 model complexes with increasing H-bonding to the ligated thiolate from its substituent. The XAS spectroscopic results show a dramatic decrease in preedge intensity. DFT calculations reproduce these effects and show that the observed changes are in fact solely due to H-bonding and not from the inductive effect of the substituent on the thiolate. These calculations also indicate that the H-bonding interaction in these systems is mainly dipolar in nature. The -2.5 kcal/mol energy of the H-bonding interaction was small relative to the large change in ligand-metal bond covalency (30%) observed in the data. A bond decomposition analysis of the total energy is developed to correlate the preedge intensity change to the change in Fe-S bonding interaction on H-bonding. This effect is greater for the reduced than the oxidized state, leading to a 260 mV increase in the redox potential. A simple model shows that E degrees should vary approximately linearly with the covalency of the Fe-S bond in the oxidized state, which can be determined directly from S K-edge XAS.  相似文献   

11.
An in situ electrochemical X-ray absorption spectroscopy (XAS) cell has been fabricated that enables high oxygen flux to the working electrode by utilizing a thin poly(dimethylsiloxane) (PDMS) window. This cell design enables in situ XAS investigations of the oxygen reduction reaction (ORR) at high operating current densities greater than 1 mA in an oxygen-purged environment. When the cell was used to study the ORR for a Pt on carbon electrocatalyst, the data revealed a progressive evolution of the electronic structure of the metal clusters that is both potential-dependent and strongly current-dependent. The trends establish a direct correlation to d-state occupancies that directly tracks the character of the Pt-O bonding present.  相似文献   

12.
A combination of soft X-ray absorption spectroscopy (XAS) measurements and StoBe density functional theory (DFT) calculations has been used to study the electronic structures of the ferrocene-labeled peptides Fc-Pro(n)-OBz (n = 1-4). Excellent agreement between the measured and the simulated data is observed in all cases, and the origin of all major spectral features was assigned. The breaking of the degeneracy of the ferrocene 3e(2u)-like unoccupied molecular orbital under the influence of a substituent attached to a Cp ring was observed experimentally. The influence of the bonding environment on the O 1s and N 1s XAS spectra was examined. A corrected assignment of one of the major features in the Fe 2p XAS spectra of ferrocene is proposed and supported by the DFT simulations, as well as the measured spectra.  相似文献   

13.
Kβ X-ray emission spectroscopy (XES) is emerging as a powerful tool for the study of chemical bonding. Analyses of the Kβ XES of ferrocene (Fc) and ferrocenium (Fc(+)) are presented as further demonstrations of the capabilities of the technique. Assignments of the valence to core (V2C) region of these spectra as electric dipole-allowed cyclopentadienyl (Cp) → Fe 1s transitions demonstrate that XES affords electronic structural insight into the energetics of ligand-based molecular orbitals (MOs). Combined with K-edge X-ray absorption spectroscopy (XAS), we show that XES can provide analogous information to photoemission spectroscopy (PES). Density functional theory (DFT) analyses reveal that the V2C transitions in Fc/Fc(+) derive their intensity from Fe 4p admixture (on the order of 5-10%) into the Cp-based MOs from which they originate. These 4p admixtures confer bonding character to the Cp-based a(2u) and e(1u) MOs to at least the extent of backbonding contributions to frontier MOs from higher-lying Cp π* MOs.  相似文献   

14.
X-ray absorption spectroscopy (XAS) is one of the best techniques to obtain the information on the electronic and local structures of materials. In the last few decades, XAS becomes a common analytical technique for the investigation of solid oxide fuel cells and proton-conducting ceramic fuel cells. In particular, operando and/or advanced XAS measurements can be recently available with the increased accessibility of synchrotron radiation. In this article, recent trends of solid oxide fuel cell and proton-conducting ceramic fuel cell researches using XAS are overviewed.  相似文献   

15.
镧在轮藻节间细胞中的分布及与细胞壁的结合状态   总被引:1,自引:0,他引:1  
利用电感耦合等离子体质谱(ICP-MS)和X射线吸收谱(XAS)研究了稀土元素镧在轮藻节间细胞中的分布和配位环境. 实验结果发现, 4 μmol•dm-3 LaCl3溶液处理12 h, 细胞中绝大部分的La存在于细胞壁且结合紧密, 各亚细胞组分中La的浓度依次为: 细胞壁>>细胞质>>液泡. XAS的结果表明La3+在细胞壁中与9个氧原子配位, 配位环境类似于醋酸镧, 说明在细胞壁中La3+的主要配位基团是羧基. 珊瑚轮藻具有很强的从培养介质中富集La3+的能力, 可用于水体中稀土元素的监测与污染治理.  相似文献   

16.
Ligand K-edge X-ray absorption spectroscopy (XAS) provides a direct experimental probe of ligand-metal bonding. In previous studies, this method has been applied to mononuclear Fe-S and binuclear 2Fe-2S model compounds as well as to rubredoxins and the Rieske protein. These studies are now extended to the oxidized and reduced forms of ferredoxin I from spinach. Because of its high instability, the mixed-valence state was generated electrochemically in the protein matrix, and ligand K-edge absorption spectra were recorded using an XAS spectroelectrochemical cell. The experimental setup is described. The XAS edge data are analyzed to independently determine the covalencies of the iron-sulfide and -thiolate bonds. The results are compared with those obtained previously for the Rieske protein and for 2Fe-2S model compounds. It is found that the sulfide covalency is significantly lower in oxidized FdI compared to that of the oxidized model complex. This decrease is interpreted in terms of H bonding present in the protein, and its contribution to the reduction potential E degrees is estimated. Further, a significant increase in covalency for the Fe(III)-sulfide bond and a decrease of the Fe(II)-sulfide bond are observed in the reduced Fe(III)Fe(II) mixed-valence species compared to those of the Fe(III)Fe(III) homovalent site. This demonstrates that, upon reduction, the sulfide interactions with the ferrous site decrease, allowing greater charge donation to the remaining ferric center. That is the dominant change in electronic structure of the Fe(2)S(2)RS(4) center upon reduction and can contribute to the redox properties of this active site.  相似文献   

17.
Despite the growing popularity of X-ray absorption spectroscopy (XAS) in scientific research, many researchers do not receive formalized training on this technique. Some of them learned from online resources, which only briefly introduce XAS and its applications. Here, this article aims to provide the overview of tips about the XAS analysis, general rules, as well as required information for presenting XAS data in publications, and some common mistakes in XAS data interpretations. Armed with these basics, the motivated aspiring XAS researchers will find existing resources more accessible and can progress much faster in understanding and using XAS.  相似文献   

18.
Changes in electronic structure upon electrochemical lithium insertion into two iron compounds, namely, rhombohedral Fe2(SO4)3 with a NASICON-type structure and monoclinic Fe2(MoO4)3, were investigated using X-ray absorption spectroscopy (XAS). Fe K-edge and L(III)- and L(II)-edge XAS revealed that the rearrangement of Fe d electrons or rehybridization of Fe d-O p bonding took place accompanied by the reduction of Fe ions upon Li insertion for both samples and that a larger change in spectra was observed in Fe2(SO4)3. In addition, the changes in the electronic structure of the polyanion units XO4(2-) (X = S or Mo) after Li insertion were also investigated by O K-edge and S K-edge or Mo L(III)-edge XAS. The results indicated that the electronic structure around oxygen markedly changed in Fe2(MoO4)3, while no significant change was observed in Fe2(SO4)3.  相似文献   

19.
Chlorine K-edge X-ray absorption spectroscopy (XAS) and ground-state and time-dependent hybrid density functional theory (DFT) were used to probe the electronic structures of O(h)-MCl(6)(2-) (M = Ti, Zr, Hf, U) and C(4v)-UOCl(5)(-), and to determine the relative contributions of valence 3d, 4d, 5d, 6d, and 5f orbitals in M-Cl bonding. Spectral interpretations were guided by time-dependent DFT calculated transition energies and oscillator strengths, which agree well with the experimental XAS spectra. The data provide new spectroscopic evidence for the involvement of both 5f and 6d orbitals in actinide-ligand bonding in UCl(6)(2-). For the MCl(6)(2-), where transitions into d orbitals of t(2g) symmetry are spectroscopically resolved for all four complexes, the experimentally determined Cl 3p character per M-Cl bond increases from 8.3(4)% (TiCl(6)(2-)) to 10.3(5)% (ZrCl(6)(2-)), 12(1)% (HfCl(6)(2-)), and 18(1)% (UCl(6)(2-)). Chlorine K-edge XAS spectra of UOCl(5)(-) provide additional insights into the transition assignments by lowering the symmetry to C(4v), where five pre-edge transitions into both 5f and 6d orbitals are observed. For UCl(6)(2-), the XAS data suggest that orbital mixing associated with the U 5f orbitals is considerably lower than that of the U 6d orbitals. For both UCl(6)(2-) and UOCl(5)(-), the ground-state DFT calculations predict a larger 5f contribution to bonding than is determined experimentally. These findings are discussed in the context of conventional theories of covalent bonding for d- and f-block metal complexes.  相似文献   

20.
Development and recent progress of a depth-resolved X-ray absorption spectroscopy (XAS) technique are presented, together with future prospects. The technique has been developed by controlling the probing depth of the electron-yield XAS data, which depends on the electron emission angle. This novel technique enables us to achieve depth profiling of the magnetic structure of thin films with a sub-nm depth resolution by using X-ray magnetic circular dichroism (XMCD) in X-ray absorption, which provides quantitative information on the element-specific spin and orbital magnetic moments. The chemical state and electronic structure at the surface and interface are also investigated by depth-resolved XAS analysis. As for future prospects, a three-dimensional micro XAS technique is being developed by combining an X-ray microbeam with depth-resolved XAS. Moreover, it is expected to manipulate magnetic anisotropy by using element-specific and depth-resolved magnetic anisotropy energies obtained from the depth-resolved XMCD to design thin films and multilayers with proper elements and proper thicknesses. The observation of the spin dynamics at the interface will be also possible in future by adopting the pump-probe method.  相似文献   