首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An on-line affinity selection method using a polymeric monolithic support is proposed for the retention of histidine-containing peptides and their subsequent separation by capillary zone electrophoresis (CZE). Monolithic capillary columns were prepared in fused-silica capillaries of 150 mum inner diameter (ID) by ionizing radiation-initiated in situ polymerization and cross-linking of diethylene glycol dimethacrylate and glycidyl methacrylate, and chemically modified with iminodiacetic acid (IDA) and copper ion. Monolithic microextractors were coupled on-line near the inlet of the separation capillary (fused-silica capillary, 75 mum ID x 28 cm from the microextractor to the detector). Model peptide mixtures of histidine-containing and histidine-noncontaining peptides were assessed. Peptides were released from the sorbent by a 5 mM imidazole solution and then separated by CZE with ultraviolet detection. Relative standard deviation values for migration times and corrected peak areas were found to be lower than 5.8 and 10.5%, respectively. IDA-Cu(II) ion modified monolithic microextractors showed a chromatographic behavior and could be reused at least 25 times. The use of monolithic supports proved to be an advantageous alternative to packed particles for the preparation of microextractors.  相似文献   

2.
Wei F  Zhang M  Feng YQ 《Electrophoresis》2006,27(10):1939-1948
A novel poly(methacrylic acid-ethylene glycol dimethacrylate) (MAA-EGDMA) monolith microextraction method coupled with CZE was proposed for rapidly determining a mixture of opiates comprising heroin, 6-monoacetylmorphine, morphine, codeine, papaverine, and narcotine in human urine. The extraction device contained a regular plastic syringe, the poly(MAA-EGDMA) monolithic capillary tube (530 microm id x 3 cm) and a plastic pinhead, which connected the monolithic capillary tube and the syringe without leakage. In the polymer monolith microextraction, the sample solution was ejected via the monolithic capillary tube by a programmable syringe pump, followed by desorption with an aliquot of appropriate solution, which was collected into a vial for the subsequent analysis by CZE. The best separation was achieved using a buffer composed of 0.1 M disodium hydrogen phosphate (adjusted to pH 4.5 with 1 M hydrochloric acid) and 20% methanol v/v with temperature and voltage of 25 degrees C and 25 kV, respectively. By applying electrokinetic injection with field-enhanced sample stacking, detection limits of 6.6-19.5 ng/mL were achieved. Excellent method of reproducibility was found over a linear range of 80-2000 ng/mL.  相似文献   

3.
A non‐specific on‐line method is presented for the extraction and preconcentration of two rare earth elements using a microcartridge containing C18‐derivatized silica particles prior to their analysis by CZE. The microcartridge, named analyte concentrator, was coupled on‐line to the inlet of the separation capillary (fused‐silica (FS) capillary, 75 μm id ×12 cm from the inlet to the microcartidge and 37 cm from the microcartridge to the detector). The reversed‐phase sorbent quantitatively retained gadolinium (Gd) and lanthanum (La) as 2‐(5‐bromo‐2‐pyridylazo)‐5‐diethylaminophenol complexes in the presence of non‐ionic micelles of polyethylene glycol tert‐octylphenyl ether, enabling sample clean‐up and concentration enhancement with minimum sample handling. The rare earth elements chelates were released from the sorbent with methanol and then analyzed by CZE with diode array detection. A background electrolyte of 20 mM sodium tetraborate containing 8% ACN, pH 9.0, was found to be optimal for the separation of metal chelates. The concentration limits of detection were lowered to picogram per liter levels (20 pg/L for La and 80 pg/L for Gd). A 1000‐fold improvement in concentration sensitivity for La‐ and Gd‐2‐(5‐bromo‐2‐pyridylazo)‐5‐diethylaminophenol complexes with respect to CZE without preconcentration was reached.  相似文献   

4.
A butyl methacrylate-co-ethylene dimethacrylate (BuMA-co-EDMA) monolith was synthesized by UV initiated polymerization at the inlet end of a 75 microm I.D. fused silica capillary that had been previously coated with a protein compatible polymer, poly(vinyl)alcohol. The monolith was used for on-line preconcentration of proteins followed by capillary electrophoresis (CE) separation. For the analysis of standard proteins (cytochrome c, lysozyme and trypsinogen A) this system proved reproducible. The run-to-run %RSD values for migration time and corrected peak area were less than 5%, which is typical of CE. As measured by frontal analysis using lysozyme as solute, saturation of a 1cm monolith was reached after loading 48 ng of protein. Finally, the BuMA-co-EDMA monolithic preconcentrator was coupled to a protein G monolithic column via a zero dead volume union. The coupled system was used for on-line removal of IgG, preconcentration of standard proteins and CE separation. This system could be a valuable sample preparation tool for the analysis of low abundance proteins in complex samples such as human serum, in which high abundance proteins, e.g., human serum albumin (HSA) and immunoglobulin G (IgG), hinder identification and quantification of low abundance proteins.  相似文献   

5.
Novel polymer monolith microextraction (PMME) using a poly(methacrylic acid-ethylene glycol dimethacrylate) (poly(MAA-EGDMA)) monolith in conjunction with capillary zone electrophoresis (CZE) was developed for the determination of several angiotensin II receptor antagonists (ARA-IIs) in human urine. The extraction device consisted of a regular plastic syringe (1 mL), a poly(MAA-EGDMA) monolithic capillary (2 cm x 530 microm I.D.) and a plastic pinhead connecting the former two components seamlessly. The extraction was achieved by driving the sample solution through the monolithic capillary tube using a syringe infusion pump, and for the desorption step, an aliquot of organic solvent was injected via the monolithic capillary and collected into a vial for subsequent analysis by CZE. The best separation was realized at 25 kV using a buffer that consisted of 50% acetonitrile and 50% buffer solution (v/v) containing 10 mM disodium hydrogenphosphate (adjusted to pH 2.3 with 1M hydrochloric acid). The method was successfully applied to the determination of telmisartan (T), irbesartan (I) and losartan (L) in urine samples with candesartan (C) as internal standard, yielding the detection limit of 15-20 ng/mL. Close correlation coefficients (R>0.999) and excellent method reproducibility were obtained for all the analytes over a linear range of 0.08-3 microg/mL.  相似文献   

6.
The use of capillary electrochromatography (CEC) for the separation by isocratic elution of synthetic peptides, proteins as well as the tryptic digest of cytochrome c has been demonstrated. The monolithic porous stationary phase was prepared from silanized fused-silica capillaries of 75 microm I.D. by in situ copolymerization of vinylbenzyl chloride and ethylene glycol dimethacrylate in the presence of propanol and formamide as the porogens. The chloromethyl groups at the surface of the porous monolith were reacted with N,N-dimethylbutylamine to form a positively charged chromatographic surface with fixed n-butyl chains. Results of studies on the influence of temperature and mobile phase composition on the retention and selectivity of separation by CEC demonstrated the feasibility of rapid polypeptide analysis and tryptic mapping at elevated temperature with high resolution and efficiency. Typically the chromatography of a tryptic digest of cytochrome c took about 5 min at 55 degrees C and 75 kV/m with hydro-organic mobile phases containing acetonitrile in 50 mM phosphate buffer, pH 2.5. For peptides and proteins plots of logarithmic k'cec against acetonitrile concentration were nonlinear, whereas Arrhenius plots for the mobilities were nearly linear. Comparison of the separation of such samples under conditions of CEC and capillary zone electrophoresis (CZE) indicates that the mechanism of separation in CEC is unique and leads to a chromatographic profile different from that obtained by CZE.  相似文献   

7.
An integrated system for DNA sequencing based on a nanoreactor for cycle-sequencing reaction coupled with on-line capillary zone electrophoresis (CZE) for purification and capillary gel electrophoresis (CGE) for separation is presented. Less than 100 nl of premixed reagent solution, which includes dye-labeled terminator pre-mix, bovine serum albumin and template, was hydrodynamically injected into a fused-silica capillary (75 microm I.D.) inside a laboratory-made microthermocycler for cycle sequencing reaction. In the same capillary, the reaction products were purified by CZE followed by on-line injection of the DNA fragments into another capillary for CGE. Over 540 base pairs (bp) of DNA can be separated and the bases called for single-standed DNA with 0.9% error rate. The total time was about 3.5 h, or a cycle time of 2 h with staggered operation. For double-stranded DNA, a longer reaction time was required and base calling up to 490 bp with 1.2% error rate was achieved. The whole system is readily adaptable to automated multiplex operation for DNA sequencing or polymerase chain reaction analysis.  相似文献   

8.
Monolithic columns of 2.7 mm I.D. have been prepared and used in electrochromatography (EC) separation. Although capillary electrochromatography (CEC) has higher separation efficiency, it displays some shortcomings, such as limited sample loadability and restricted concentration detectability etc. In this paper, we investigate the feasibility of EC separation with millimeter diameter monolithic columns. By using a designed preparation method of monolithic column packed with about 150 microm quartz sand, the effect of Joule heating can be reduced, and the processes of frit making and column packing can be avoided. The concentration detectability of the EC is improved comparing with that of CEC. Moreover, the separation efficiency of 52,000 plates/m was achieved with a 70 mm length and 2.7 mm I.D. monolithic column.  相似文献   

9.
Low capacity anion exchangers for IC have been prepared by modification of nonporous uniformed silica MICRA microbeads and by modification of the organic polymeric monolithic matrixes prepared in situ in quarz capillary. Due to the small particle size (1.5 microm) high-performance adsorbents were prepared allowing to obtain up to 190,000 tp/m. However, the column possesses a very high back-pressure and can be used in a short length up to 50 mm only to meet the requirements of conventional chromatographic equipment. An analysis of a test mixture of seven anions was completed within 3 min with a back column pressure of about 350 bar (HETP of about 5.5 microm, where HETP is the height equivalent to the theoretical plate). Monolithic capillary columns provide lower efficiency per column unit length than MICRA columns; however, they can be used at a longer length because of their low flow resistance. Monolithic column of ca. 40 cm length has workable pressure below 10 bar and allows separation of a five anions test mixture within less than 10 min. A better efficiency of monolithic column (HETP approximately 75 microm) can be achieved at reduced flow rates when the analysis time is not a critical parameter.  相似文献   

10.
Huang K  Zhou N  Chen B 《色谱》2011,29(10):957-961
利用溶胶-凝胶法,经过烷氧基硅烷的水解、硅羟基的缩聚、凝胶化、陈化、中孔制备、干燥和表面修饰等步骤制备了全氟癸基修饰的毛细管硅胶整体柱。采用该整体柱对全氟辛烷磺酸(PFOS)进行萃取富集,考察其富集特性和效率,并与传统的C18毛细管硅胶整体柱进行对比。结果表明,全氟癸基修饰毛细管硅胶整体柱(15 cm×75 μm)对PFOS具有更高的吸附量和更好的富集选择性,其平均吸附量可以达到75 ng;样品中PFOS的质量浓度为0.25 mg/L时,富集倍数平均可以达到29倍。此全氟癸基修饰毛细管硅胶整体柱对PFOS具有良好的萃取富集性能,可用于水质中痕量PFOS的萃取富集。  相似文献   

11.
The determination of three aconitine alkaloids (hypaconitine, aconitine, mesaconitine) in five traditional Chinese medicines including two Tibetan medicines, Chuanwu, Caowu, Fuzi, Aconitum Tanguticum Maxim and Aconitum Gymnandrum Maxim by non-aqueous capillary electrophoresis using a new recording mode is described. The dissociation constants of aconitine, mesaconitine and hypaconitine have also been determined by CZE and were 7.71, 6.60 and 6.25, respectively. The separation was achieved by optimizing the applied voltage, the pH and the concentration of the buffer. The electrophoretic medium was 20 mM borax-70% (v/v) methanol (pH 8.5) and an uncoated capillary (50 cm x 75 microm i.d.) was used. Detection was carried out with a UV monitor at 214 nm. The total time for separation and determination was under 13 min.  相似文献   

12.
《Analytica chimica acta》2004,514(2):167-177
In this work, an on-line preconcentration capillary electrophoresis method was optimized and evaluated for the purity control of the biologically active synthetic peptide fas-F (a 28-residue long fragment of fasciculin-1) and applied for the purity profiling of angiotensin I, oxytocin, bradykinin and luteinizing hormone releasing hormone. The laboratory-made device of the analyte concentrator cartridge consisted of a fused-silica capillary piece (150 μm i.d.×8 mm in length) packed with silica-based C18 reversed-phase chromatographic material and coupled on-line near the inlet of the separation capillary (bare fused-silica capillary, 75 μm from the concentrator to the detector). Separation of impurities present in assayed samples was achieved by using 25 mM potassium dihydrogen phosphate, pH 3.5, as running buffer and a mixture of acetonitrile: running buffer, 75:25 (v/v), as elution buffer. The intra-day relative standard deviation (R.S.D.) values for migration times ranged from 3.4 to 4.2 and 2.2-2.6% for peak areas. The inter-day R.S.D. values were 5.6-7.1 and 4.6-5.1% for migration times and peak areas, respectively. The impurity profiles obtained for each peptide were compared by CZE and on-line preconcentration CE. The proposed method allowed the preconcentration and separation of impurities with greater selectivity and higher sensitivity (100-200-fold) with respect to capillary zone electrophoresis without on-line preconcentration.  相似文献   

13.
Monolithic silica capillary columns were successfully prepared in a fused silica capillary of 530 microm inner diameter and evaluated in HPLC after octadecylsilylation (ODS). Their efficiency and permeability were compared with those of columns pakked with 5-microm and 3-microm ODS-silica particles. The monolithic silica columns having different domain sizes (combined size of through-pore and skeleton) showed 2.5-4.0-times higher permeability (K= 5.2-8.4 x 10(-14) m2) than capillary columns packed with 3-mm particles, while giving similar column efficiency. The monolithic silica capillary columns gave a plate height of about 11-13 microm, or 11 200-13 400 theoretical plates/150 mm column length, in 80% methanol at a linear mobile phase velocity of 1.0 mm/s. The monolithic column having a smaller domain size showed higher column efficiency and higher pressure drop, although the monolithic column with a larger domain size showed better overall column performance, or smaller separation impedance (E value). The larger-diameter (530 microm id) monolithic silica capillary column afforded a good peak shape in gradient elution of proteins at a flow rate of up to 100 microL/min and an injection volume of up to 10 microL.  相似文献   

14.
Monolithic capillary columns were prepared via ring-opening metathesis polymerization (ROMP) using norborn-2-ene (NBE) and 1, 4, 4a, 5, 8, 8a-hexahydro-1, 4, 5, 8-exo,endo-dimethanonaphthalene (DMN-H6) as monomers. The monolithic polymer was copolymerized with Grubbs-type initiator RuCl(2)(PCy(3))(2)(CHPh) and a suitable porogenic system within the confines of fused silica capillaries of different inner diameter (I.D.). The first part of the study focused on batch-to-batch reproducibility of ROMP-derived capillary monoliths. Capillary monoliths of 200 microm I.D. showed good reproducibility in terms of retention times, with relative standard deviations (RSD) of 1.9% for proteins and 2.2% for peptides. However, the separately synthesized capillary monoliths revealed pronounced variation in back pressure with RSD values of up to 31%. These variations were considerably reduced by cooling of the capillaries during polymerization. Using this optimized preparation procedure capillary monoliths of 100 and 50 microm I.D. were synthesized and the effects of scaling down the column I.D. on the morphology and on the reproducibility of the polymerization process were investigated. In the second part, the applicability of ROMP-derived capillary monoliths to a separation problem common in medical research was assessed. A 200 microm I.D. monolithic column demonstrated excellent separation behavior for insulin and various insulin analogs, showing equivalent separation performance to Vydac C4 and Zorbax C3-based stationary phases. Moreover, the high permeability of monoliths enabled chromatographic separations at higher flow rates, which shortened analysis time to about one third. For the analysis of insulin in human biofluid samples, enhanced sensitivity was achieved by using a 50 microm I.D. ROMP-derived monolith.  相似文献   

15.
Monolithic capillary columns (320 microm I.D.) were prepared for capillary liquid chromatography (CLC) by radical polymerization of butylmethacrylate (BMA) and ethylenedimethacrylate (EDMA) in the presence of a porogen solvent containing propan-1-ol, butane-1,4-diol and water. The influence of the contents of the porogen solvent and EDMA in the polymerization mixture on the monolith porosity and column efficiency was investigated. The composition of the polymerization mixture was optimized to attain a minimum HETP of the order of tens of microm for test compounds with various polarities. The separation performance and selectivity of the most efficient monolithic column prepared was characterized by van Deemter curves, peak asymmetry factors and Walters hydrophobicity and silanol indices. It was demonstrated that the 320-microm I.D. monolithic column exhibited CLC separation performance similar to that observed for 100- and 150-microm I.D. monolithic columns reported in the literature; moreover, the 320-microm I.D. column was easier to operate in CLC and exhibited a higher sample loadability.  相似文献   

16.
Kato M  Dulay MT  Bennett B  Chen J  Zare RN 《Electrophoresis》2000,21(15):3145-3151
A solution is prepared of 5 microm silica particles modified with (S)-N-3,5-dinitrobenzoyl-1-naphthylglycine (particle 1) or (S)-N-3,5-dinitrophenylaminocarbonyl-valine (particle 2) suspended in liquid tetraethylorthosilicate, ethanol, and aqueous hydrochloric acid. This solution is injected under pressure into a 30 cm long, 75 microm inner diameter capillary column and heated for 1 h at 120 degrees C after which the modified particles are embedded in a monolithic column of sol gel. The packed column measures approximately 15 cm from the inlet to the window used to view the laser-induced fluorescence. Thirteen different amino acids and three nonprotein amino acids are derivatized with the fluorogenic reagent 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F) before injection onto the column for capillary electrochromatographic separation. The enantiomeric separation of the monolithic column packed with particle 1 results in a resolution ranging from 1.14 to 4.45, whereas that packed with particle 2 results in a resolution ranging from 0.79 to 1.17. On the basis of resolution and amount of chiral packing material the enantiomeric separation obtained by capillary electrochromatography is judged to be superior to that obtained previously with high performance liquid chromatography (HPLC).  相似文献   

17.
CZE was assayed for the separation of carbamate pesticides susceptible to protonation (Pirimicarb, Carbendazim). Different electrophoretic media with high organic contents were explored, adequate separation and resolution being achieved when a BGE based on ACN with acetic acid in the presence of SDS as an ionic additive was used. With a view to increasing the sensitivity of the method, an in-capillary SPE step prior to the electrophoretic separation was developed. We employed a monolithic polymer formed in situ within the capillary as a medium for analyte retention. The synthesized monolithic bed exhibited high porosity and allowed samples to be loaded at flow rates of about 65 microL/min by applying a pressure of 12 bar. A 5-cm length of monolithic sorbent was used to preconcentrate the target analytes from aqueous samples. The analytes retained were eluted from the polymeric phase directly in the separation capillary with the same electrophoretic medium used for their further separation by CZE. For a 15-min preconcentration time, the in-line SPE-CZE approach proposed here permitted the determination of these pesticides in drinking water at a concentration level of 0.1 microg/L, as demanded by current EU legislation.  相似文献   

18.
High-efficiency peptide analysis using multimode pressure-assisted capillary electrochromatography/capillary electrophoresis (pCEC/pCE) monolithic polymeric columns and the separation of model peptide mixtures and protein digests by isocratic and gradient elution under an applied electric field with UV and electrospray ionization-mass spectrometry (ESI-MS) detection is demonstrated. Capillary multipurpose columns were prepared in silanized fused-silica capillaries of 50, 75, and 100 microm inner diameters by thermally induced in situ copolymerization of methacrylic monomers in the presence of n-propanol and formamide as porogens and azobisisobutyronitrile as initiator. N-Ethylbutylamine was used to modify the chromatographic surface of the monolith from neutral to cationic. Monolithic columns were termed as multipurpose or multimode columns because they showed mixed modes of separation mechanisms under different conditions. Anion-exchange separation ability in the liquid chromatography (LC) mode can be determined by the cationic chromatographic surface of the monolith. At acidic pH and high voltage across the column, the monolithic stationary phase provided conditions for predominantly capillary electrophoretic migration of peptides. At basic pH and electric field across the column, enhanced chromatographic retention of peptides on monolithic capillary column made CEC mechanisms of migration responsible for separation. The role of pressure, ionic strength, pH, and organic content of the mobile phase on chromatographic performance was investigated. High efficiencies (exceeding 300 000 plates/m) of the monolithic columns for peptide separations are shown using volatile and nonvolatile, acidic and basic buffers. Good reproducibility and robustness of isocratic and gradient elution pressure-assisted CEC/CE separations were achieved for both UV and ESI-MS detection. Manipulation of the electric field and gradient conditions allowed high-throughput analysis of complex peptide mixtures. A simple design of sheathless electrospray emitter provided effective and robust low dead volume interfacing of monolithic multimode columns with ESI-MS. Gradient elution pressure-assisted mixed-mode separation CE/CEC-ESI-MS mass fingerprinting and data-dependent pCE/pCEC-ESI-MS/MS analysis of a bovine serum albumin (BSA) tryptic digest in less than 5 min yielding high sequence coverage (73%) demonstrated the potential of the method.  相似文献   

19.
Bedair M  El Rassi Z 《Electrophoresis》2002,23(17):2938-2948
A novel monolithic stationary phase having long alkyl chain ligands (C17) was introduced and evaluated in capillary electrochromatography (CEC) of small neutral and charged species. The monolithic stationary phase was prepared by the in situ copolymerization of pentaerythritol diacrylate monostearate (PEDAS) and 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPS) in a ternary porogenic solvent consisting of cyclohexanol/ethylene-glycol/water. While AMPS was meant to support the electroosmotic flow (EOF) necessary for transporting the mobile phase through the monolithic capillary, the PEDAS was introduced to provide the nonpolar sites for chromatographic retention. Monolithic columns at various EOF velocities were readily prepared by conveniently adjusting the amount of AMPS in the polymerization solution as well as the composition of the porogenic solvent. The monolithic stationary phases thus obtained exhibited reversed-phase chromatography behavior toward neutral solutes and yielded a relatively strong EOF. For charged solutes (e.g., dansyl amino acids), nonpolar as well as electrostatic interaction/repulsion with the monoliths were observed in addition to electrophoretic migration. Therefore, for charged solutes, selectivity and migration can be readily manipulated by changing various parameters including the nature of the monolith and the composition of the mobile phase (e.g., pH, ionic strength and organic modifier). Ultrafast separation on the time scale of seconds of 17 different charged and neutral pesticides and metabolites were performed using short capillary columns of 8.5 cm x 100 microm ID.  相似文献   

20.
A silica-based monolithic stationary phase prepared by the sol-gel process in a 100 microm I.D. fused-silica (FS) capillary has been modified chemically with 3-mercaptopropyl trimethoxysilane followed by immobilization of a strong cation-exchange (SCX) type chiral selector, (S)-N-(4-allyloxy-3,5-dichlorobenzoyl)-2-amino-3,3-dimethylbutane phosphonic acid, by radical addition reaction onto the reactive sulfhydryl surface. After a fine-tuning of the mobile phase composition, the enantioselective capillary column was evaluated for the separation of various chiral basic drugs by enantioselective non-aqueous capillary electrochromatography (CEC), in comparison to capillary column analogs packed with 3.5 microm silica particles having attached the same selector. The performance of the monolithic silica column was further compared to corresponding polymethacrylate-based organic polymer monoliths. The study indicated that strong counter-ions such as 2-aminobutanol or N,N,N',N'-tetramethylethylenediamine are needed, although they reduce the electroosmotic flow velocity and separation factors in comparison to less efficient counter-ions, in order to allow the elution of the oppositely charged solutes in the ion-exchange retention mode within reasonable run time and as sharp zones. In contrast, weak counter-ions such as N,N-diisopropylethylamine (Huenig base) provided stronger electroosmotic flow and much better separation factors, but relatively poor peak efficiencies. Overall, with the chemically functionalized monolithic silica column the high quality separations of packed column analogs could be approximated, with regards to both separation factors and peak performances. On the other hand, the monolithic capillary column certainly outperformed the packed column in terms of system robustness under capillary electrochromatography conditions and showed excellent column longevity. The enantioselective strong cation-exchange-type monolithic silica column performed also well in comparison to the organic polymer monolith.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号