首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Q Dong  W Jin 《Electrophoresis》2001,22(13):2786-2792
A method for determination of the drug diclofenac sodium introduced into individual human erythrocytes by electroporation using capillary zone electrophoresis with electrochemical detection at a carbon fiber array microelectrode was developed. In this method, the whole cell was injected into the separation capillary by electromigration. Cell lysis was accomplished by injecting a plug of the separation buffer (1.25 x 10(-2) mol/L Na2B4O7-3.13 x 10(-3) mol/L NaOH). The optimum conditions of separation and detection were 20 kV for the separation voltage and 1.0 V for the detection potential. The concentration of diclofenac sodium in the single cells was quantified by a calibration curve. The mean concentration of diclofenac sodium introduced into the cell was 4.21 micromol/L. The relative standard deviation of the concentration of diclofenac sodium introduced into ten cells is 10%.  相似文献   

2.
A Pd/IrO(2) co-electrodeposited glassy carbon electrode was prepared and the electrochemical behavior of glutathione (GSH) at this chemically modified electrode (CME) has been studied by cyclic voltammetry (CV). The results indicated that the modified electrode efficiently exhibited electrocatalytic oxidation for GSH with relatively high sensitivity, stability, and long-life. Coupled with high-performance liquid chromatography (HPLC), the Pd/IrO(2) modified electrode was utilized for the electrochemical detection (ECD) of the thiocompounds, glutathione and cysteine (Cys). The peak currents were linear with the substance concentrations in the range of 1.0 x 10(-5) mol L(-1) to 8.0 x 10(-4) mol L(-1) for GSH and 4.0 x 10(-6) mol L(-1) to 2.0 x 10(-4) mol L(-1) for Cys. The detection limits were 2.0 x 10(-6) mol L(-1) for GSH and 5.0 x 10(-7) mol L(-1) for Cys with S/N of 3. The method has been successfully applied to assess the contents of GSH and Cys in rat brain microdialysates.  相似文献   

3.
Jin W  Dong Q  Yu D  Ye X  Li W 《Electrophoresis》2000,21(8):1540-1544
A capillary electrophoresis (CE)/electrochemical detection system with on-line deoxygenation was developed, consisting of a deoxygenation injector, a deoxygenation protector, and an electrochemical detection cell. When the system was utilized for 60 min, the steady-state current of oxygen detected could be dropped to 3% of the original value for the gold/mercury amalgam electrode and to 8% of the original value for the gold electrode, and the limit of detection could be decreased two orders of magnitude for the reducible analytes such as TI+ (from 3.1 x 10-5 mol/L to 8.0 x 10-7 mol/L) and metronidazole (from 3.8 x 10-5 mol/L to 4.0 x 10-7 mol/L).  相似文献   

4.
Jin W  Xu Q  Li W 《Electrophoresis》2000,21(7):1415-1420
Capillary zone electrophoresis was employed for the determination of clozapine using an end-column amperometric detection at a carbon fiber array microdisk electrode with simplified capillary/electrode alignment. The optimum conditions of separation and detection are: Britton-Robinson buffer, pH 2.0 (1.3 x 10(-2) mol/L total concentration of acids, 3.2 x 10(-3) mol/L NaOH), 15 kV for separation voltage, 5 kV and 10 s for injection voltage and injection time, respectively. The limit of detection is 4.2 x 10(-7) mol/L or 1.2 fmole (signal to noise, S/N = 2). The relative standard deviation is 1.4% for the migration time and 2.5% for the electrophoretic peak current. The method was applied to the determination of clozapine in human blood. The recovery of the method is between 94-104%.  相似文献   

5.
Sun X  Jin W  Li D  Bai Z 《Electrophoresis》2004,25(12):1860-1866
A novel method for the determination of alkaline phosphatase (ALP) isoenzymes in individual fibroblast cells of mouse bone marrow was developed by combining capillary electrophoresis with an on-capillary enzyme-catalyzed reaction and electrochemical detection. In this method, a single an cell, followed by 5.0 x 10(-2) mol/L Na2B4O7- 3.0 x 10(-2) mol/L NaCl (pH 9.8) as cell lysis solution, was injected into the inlet of the separation capillary by electromigration. The cell was lysed by applying a voltage of 2 kV. The ALP isoenzymes in the cell were preseparated at 20 kV for 1 min, and then allowed to react for 30 min with disodium phenyl phosphate as enzyme substrate in the running buffer. ALP converted disodium phenyl phosphate into its product, phenol, at a relatively high reaction rate without consumption, with resultant amplification of the signal on prolonged reaction time, producing an adequate amount of product for final detection. A mass detection limit as low as 3.5 x 10(-21) mol/L (corresponding to 1.5 nU) was achieved. Finally, the two zones of products generated by ALP isoenzymes were detected at the outlet of the capillary by using the end-capillary amperometric detection at a carbon fiber microdisk bundle electrode with a constant potential.  相似文献   

6.
A simple, reliable and reproducible method, based on capillary zone electrophoresis with amperometric detection, has been developed for the determination of idarubicin in human urine. A carbon disk electrode was used as working electrode. The optimal conditions of separation and detection were pH 5.6 phosphate buffer (0.20 mol/L), 22 kV for the separation voltage and 1.00 V (vs. Ag/AgCl, 3 mol/L KCl) for the detection potential. The linear range was from 4.0 x 10(-7) to 2.0 x 10(-5) mol/L with a regression coefficient of 0.9986, and the detection limit was 8.0 x 10(-8) mol/L. The method was directly applied to the determination of idarubicin in spiked human urine without any other sample pretreatment except filtration, and the assay results were satisfactory.  相似文献   

7.
Cao W  Liu J  Yang X  Wang E 《Electrophoresis》2002,23(21):3683-3691
A new end-column electrochemiluminescence (ECL) detection technique coupling to capillary electrophoresis (CE) is characterized. A 300 microm diameter Pt working electrode was used to directly couple with a 75 microm inner diameter separation capillary without an electric field decoupler. The hydrodynamic cyclic voltammogram (CV) of Ru(bpy) 3 2+ showed that electrophoretic current did not affect the ECL reaction. The presence of high-voltage (HV) field only resulted in the shift of the ECL detection potential. The distance of capillary to electrode was an important parameter for optimizing detection performance as it determined the characteristics of mass transport toward the electrode and the actual concentration of Ru(bpy) 3 2+ in the detection region. The optimum distance of capillary to electrode was decided by the inner diameter of the capillary, too. For a 75 microm capillary, the working electrode should be placed away from the capillary outlet at a distance within the range of 220-260 microm. The effects of pH value of ECL solution and molecular structure of analytes on peak height and theoretical plate numbers were discussed. Using the 75 microm capillary, under the optimum conditions, the method provided a linear range for tripropylamine (TPA) between 1 x 10(-10) and 1 x 10(-5) mol/L with correlation coefficient of 0.998. The detection limit (signal-to-noise ratio S/N = 3) was 5.0 x 10(-11) mol/L. The relative standard deviation in peak height for eight consecutive injections was 5.6%. By this new technique lidocaine spiked in a urine sample was determined. The method exhibited the linear range for lidocaine from 5.0 x 10(-8) to 1.0 x 10(-5) mol/L with correlation efficient of 0.998. The limit of detection (S/N = 3) was 2.0 x 10(-8) mol/L.  相似文献   

8.
The weak fluorescence of N-[P-(2-benzoxazolyl)phenyl]maleimide (BOPM) can be greatly enhanced by thiol-containing compounds. A sensitive and simple spectrofluorimetric method based on the use of BOPM has been developed for the determination of thiols such as cysteine (Cys) and reduced glutathione (GSH). Calibration plots were linear in the concentration range from 0 to 1.6 x 10(-7) mol L(-1) for Cys and 0 to 1.7 x 10(-7) mol L(-1) for GSH. The detection limits (3a) were 2.36 x 10(-10) mol L(-1) for Cys and 1.49 x 10(-10) mol L(-1) for GSH. Many other amino acids (present at 100-fold greater concentrations) did not interfere with the determination. The proposed method has been used for the determination of Cys in protein hydrolysate and cystine electrolyte or GSH in serum, with recoveries of 95.4-103.7%.  相似文献   

9.
A new chemically modified electrode based on the immobilization of Pt particles is fabricated and exhibits electrocatalytic oxidation for L-cysteine (L-Cys), glutathione (GSH) and penicillamine (PEN) with relatively high sensitivity. It is also adaptable to HPLC for pulsed amperometric detection (PAD) of these thiols. PAD largely improves the detection sensitivity because the alternated polarizations can effectively clean and reactivate the electrode surface. It is shown that the peak currents of L-Cys, GSH and PEN are linear to their concentrations, with the calculated detection limit of 1.1 x 10(-7), 1.8 x 10(-7) and 3.8 x 10(-7) mol L(-1), respectively (S/N = 3). The method has been successfully applied to assess the contents of L-Cys and GSH in rat striatal microdialysates. The average contents of the two analytes in rat striatum are 2.6 x 10(-6) and 2.8 x 10(-6) mol L(-1), respectively.  相似文献   

10.
建立了胶束电动毛细管色谱结合电化学安培检测同时分析中药马齿苋中多巴胺和去甲肾上腺素的方法。考察了缓冲液的浓度、pH值、十二烷基硫酸钠(SDS)浓度以及工作电极电势对分离检测的影响。在优化的条件下,多巴胺和去甲肾上腺素在1.0×10-6~5 0×10-4mol/L范围内有良好线性,浓度检测限(S/N=3)分别为8 7×10-7mol/L和4 2×10-7mol/L,质量检测限分别为1 45fmol和0 41fmol。该方法组分定性可靠,不需要衍生处理,选择性好。将该法应用于中药马齿苋样品的分析,获得了较好的结果。  相似文献   

11.
Liu YM  Cao JT  Tian W  Zheng YL 《Electrophoresis》2008,29(15):3207-3212
A novel method for the determination of norfloxacin (NOR) and levofloxacin (LVX) was developed by CE separation and electrochemiluminesence detection (ECL). The methods for capillary conditioning and the effect of solvent type were studied. Parameters affecting the CE and ECL were also investigated. Under the optimum conditions, the two analytes were well separated within 9 min. The LODs (S/N = 3) in standard solution are 4.8 x 10(-7) mol/L for NOR and 6.4 x 10(-7) mol/L for LVX, respectively. The precisions of intraday and interday are less than 4.2 and 8.1%, respectively. The LOQs (S/N = 10) in real human urine samples are 1.2 x 10(-6) mol/L for NOR and 1.4 x 10(-6) mol/L for LVX, respectively. The applicability of the proposed method was illustrated in the determination of NOR and LVX in human urine samples and the monitoring of pharmacokinetics for NOR. The recoveries of NOR and LVX at different levels in human urine samples were between 84.3 and 92.3%.  相似文献   

12.
A method based on capillary electrophoresis with electrochemical detection (CE-ED) has been developed for the determination of hesperidin (HP) and synephrine (SP) in the Chinese traditional herbal drug, Pericarpium Citri Reticulatae, the dried rind of the ripe fruits of Citrus reticulata Blanco (mandarin orange). The effects of some important factors such as the acidity and concentration of running buffer, separation voltage, and detection potential were investigated to determine the optimum conditions. The working electrode was a 300 microm diameter carbon disc electrode positioned opposite the outlet of the capillary. Both analytes could be well separated within 5 min in a 40 cm long capillary at a separation voltage of 12 kV in 50 mmol L(-1) borate buffer (pH 9.0). Excellent linearity was observed for the dependence of peak current on analyte concentration in the range from 2.5 x 10(-6) to 1.0 x 10(-3) mol L(-1) for SP and from 5.0 x 10(-6) to 1.0 x 10(-3) mol L(-1) for HP. The detection limits (S/N=3) for SP and HP were 4.96 x 10(-7) mol L(-1) and 6.54 x 10(-7) mol L(-1), respectively. This method has been successfully applied for the analysis of real samples, with satisfactory results.  相似文献   

13.
Guan Y  Chu Q  Fu L  Ye J 《Journal of chromatography. A》2005,1074(1-2):201-204
A new and efficient method for the determination of antioxidants [Propyl gallate (PG), tert-butylhydroquinone (TBHQ), butylated hydroxyanisole (BHA), and butylated hydroxytoluene (BHT)] in cosmetics has been established by using micellar electrokinetic capillary chromatography with electrochemical detection (MECC-ED). Under the optimum conditions of the method, all analytes were successfully separated within 13 min at the separation voltage of 18 kV in a 20 mmol/L borate running buffer (pH 7.4) containing 25 mmol/L sodium dodecyl sulfate. The excellent linearity was obtained in the concentration range from 5.0 x 10(-4) to 2.0 x 10(-6) mol/L and the detection limits (S/N = 3) of PG, TBHQ, BHA, and BHT range from 3 x 10(-7) to 3 x 10(-6) mol/L.  相似文献   

14.
A universal detector based on backscatter interferometry has been developed to perform nanoliter volume refractive index measurements for on-chip sodium dodecyl sulfate (SDS) gel based (polyethylene oxide gel) separations and quantification label-free proteins. The on-chip interferometric backscatter detector (OCIBD) system consists of a simple, folded optical train based on the interaction of a laser beam with an etched channel in the shape of half cylinder in a fused-silica plate. The backscattered light from the channel takes on the form of a high-contrast interference pattern that contains information related to the bulk properties of the fluid located within the probe or detection volume of 2.32 x 10(-9) L. Depending on capillary electrophoresis (CE) injection method, the positional changes of the interference pattern extrema (fringes) allow for the quantification of unlabeled proteins at levels ranging from 11 to 310 amol (2.7 x 10(-8)mol/L) with a linear dynamic range of 2.5 decades (egg albumin). Using OCIBD microchannel-based SDS capillary gel electrophoresis (SDS/CGE), separation and detection of five label-free proteins was achieved in less than 100 seconds with detection limits ranging from 0.95 pg (1.1 x 10(-16)mol or 2.5 x 10(-7)mol/L) of calmodulin to 7.0 pg (1.0 x 10(-16)mol or 2.4 x 10(-7)mol/L) for bovine serum albumin (BSA) without signal filtering or active thermal control. This development shows that a universal detector based on backscatter interferometry can be used effectively for on-chip label-free solute analysis.  相似文献   

15.
Jin W  Li W  Xu Q  Dong Q 《Electrophoresis》2000,21(7):1409-1414
Capillary zone electrophoresis was employed for the determination of metronidazole using end-column amperometric detection with a gold microelectrode at a constant potential of -0.52V vs. saturated calomel electrode. To overcome interference of oxygen in the solution, a deaeration injector and a deaeration protector at the detection cell were used. The optimum conditions of separation and detection are 1.0 x 10(-3) mol/L potassium dihydrogen citrate (KH2C6H5O7) for the buffer solution, 20 kV for the separation voltage, and 5 kV and 10 S for injection voltage and injection time, respectively. The limit of detection is 6.0 x 10(7) mol/L or 0.78 fmole (S/N = 3). The relative standard deviation is 3.9% for the electrophoretic peak current. The method was applied to the determination of metronidazole in human urine.  相似文献   

16.
Fang L  Kang J  Yin XB  Yang X  Wang E 《Electrophoresis》2006,27(22):4516-4522
CE with electrochemiluminescence (ECL) detection technique was successfully applied for the chiral separation of a kind of class IA antiarrhythmic racemic drug. To the best of our knowledge, this is the first report of ECL detection used in chiral CE. To get better detection sensitivity and good enantioresolution at the same time, the conditions of capillary inlet and outlet buffer were systematically optimized. Unlike the traditional chiral separation method, the buffers we used in the capillary inlet and outlet differed from each other in terms of buffer pH, ionic strength, type of BGE as well as buffer composition. Under the optimum conditions, baseline enantioseparation and highly sensitive detection of the enantiomers were achieved. Wide linear relationship of each enantiomer was achieved in the range of 5 x 10(-7) to 2 x 10(-5) mol/L with relative coefficients of 0.996 and 0.997, respectively. The detection limits were estimated to be 8 x 10(-8) and 1.0 x 10(-7) mol/L (S/N = 3) for the enantiomers, respectively. In addition, a successful application of this new method to the chiral separation of the racemic drug in spiked plasma samples confirmed the validity and applicability of the chiral CE-ECL method.  相似文献   

17.
The separation of three common anabolic steroids (methyltestosterone, methandrostenolone and testosterone) was performed for the first time by capillary EKC. Different charged CD derivatives and bile salts were tested as dispersed phases in order to achieve the separation. A mixture of 10 mmol/L succinylated-beta-CD with 1 mmol/L beta-CD in a 50 mmol/L borate buffer (pH 9) enabled the separation of the three anabolic steroids in less than 9 min. Concentration LODs, obtained for these compounds with low absorption of UV light, were approximately 5 x 10(-5) mol/L. The use of online reverse migrating sample stacking with large-volume injection (the effective length of the capillary) enabled to improve the detection sensitivity. Sensitivity enhancement factors (SEFs) ranging from 95 (for testosterone) to 149 (for methyltestosterone) were achieved by single stacking preconcentration. Then, the possibilities of multistep stacking to improve the sensitivity for these analytes were investigated. SEFs obtained by double stacking preconcentration ranged from 138 to 185, enabling concentration LODs of 2.79 x 10(-7) mol/L (for methyltestosterone), 3.47 x 10(-7) mol/L (for testosterone) and 3.56 x 10(-7) mol/L (for methandrostenolone). Although online triple stacking preconcentration was achieved, its repeatability was very poor and SEFs for the studied analytes were not calculated.  相似文献   

18.
A capillary electrophoresis with tris(2,2'-bipyridyl)ruthenium(II)-based electrogenerated chemiluminescence detection method was investigated for the determination of monosaccharides using 2-diethylaminoethanethiol as a derivatizing reagent. Xylose, rhamnose, glucose and glucosamine were selected for the demonstration of the method. Under optimal conditions, the calibration curve of glucose was linear over the range of 1.0 x 10(-4) to 1.0 x 10(-7) mol/L (R = 0.999) and the detection limit was 6.0 x 10(-8) mol/L (S/N = 3). The method was successfully applied for the assay of glucose in angelica.  相似文献   

19.
Ding SN  Xu JJ  Chen HY 《Electrophoresis》2005,26(9):1737-1744
The major goal of this work was to develop a new solid-state electrochemiluminescence (ECL) detector suitable for capillary electrophoresis (CE). The detector was fabricated by coating a sol-gel derived zirconia (ZrO(2))-Nafion composite film on a graphite electrode, then the zirconia-Nafion modified electrode was immersed in tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)(3) (2+)) solution to immobilize this active chemiluminescence reagent. The voltammetric and ECL behaviors of the detector were investigated and optimized in tripropylamine solution. The ratio of 53% for zirconia in the zirconia-Nafion composite provided the highest luminescence intensity of immobilized Ru(bpy)(3) (2+). The ECL can maintain its stability very well in the phosphate solution in the period of 5-90 h when the solid-state ECL detector was immersed in the solution all the time. The optimum distance of capillary outlet to the solid-state ECL detector has been found to be ca. 50-80 microm for a 75 microm capillary. The effects of ionic strength and pH of ECL solution on peak height were investigated. The CE with solid-state ECL detector system was successfully used to detect tripropylamine, lidocaine, and proline. The detection limits (S/N = 3) were 5 x 10(-9) mol.L(-1) for tripropylamine, 1 x 10(-8) mol.L(-1) for lidocaine and 5 x 10(-6) mol.L(-1) for proline, and the linear ranges were from 1.0 x 10(-8) to 1.0 x 10(-5) mol.L(-1) for tripropylamine, 5.0 x 10(-7) mol.L(-1) to 1.0 x 10(-5) mol.L(-1) for lidocaine and 1.0 x 10(-5) to 1.0 x 10(-3) mol.L(-1) for proline, respectively.  相似文献   

20.
Wang J  Ren J 《Electrophoresis》2005,26(12):2402-2408
In this paper we have presented a sensitive and rapid immunoassay (IA) method by capillary electrophoresis with an enhanced chemiluminescence detection system (CE-CL) based on the catalytic effects of horseradish peroxidase (HRP) on the luminol-hydrogen peroxide reaction. The conditions for the CL reaction and electrophoresis were systematically investigated using HRP as a model sample. The linear range from 2.5 x 10(-11) to 1.0 x 10(-9) mol/L (R = 0.999), and the detection limit of 1.0 x 10(-12) mol/L (signal-to-noise ratio = 3) for HRP were achieved using para-iodophenol as CL enhancer. The relative standard deviations of the migration time and peak area for 5.0 x 10(-10) mol/L HRP (n = 7) were 0.26 and 4.8%, respectively, using a CE system with a home-built CL detector. Under the optimal condition, the HRP-labeled CA125 antibody (Ab) and the Ab-antigen complex were well separated within 4 min by CE using a high-pH buffer (pH 10.20). The assay was successfully used for quantification of CA125 in human sera from health controls and patients associated with ovarian cancer, and the recoveries of the standard addition experiments were 93-109%. Our primary results demonstrated that IA based on CE-CL detection is a powerful tool for clinical diagnosis combined with these commercial IA kits.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏