首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An on-line stacking method based on moving reaction boundary (MRB) was developed for the sensitive determination of barbital and phenobarbital in human urine via capillary electrophoresis (CE). The optimized conditions for the method are: 60 mmol L−1 pH 11.0 Gly–NaOH as the background electrolyte, 10 mmol L−1 pH 5.5 Gly–HCl as sample buffer, secobarbital as the internal standard (IS), 12.5 kV, 1.4 psi 10 s sample injection, 75 μm ID 60.2 cm total length (50 cm effective length) capillary and 214 nm detect wavelength. Under the optimized conditions, the method can well stack and separate barbital and phenobarbital in urine samples and result in 20.5-fold and 22.6-fold improvement in concentration sensitivity for barbital and phenobarbital, respectively. Furthermore, the method holds: (1) good linear calibration functions for the two target compounds (correlation coefficients r > 0.999), (2) low limits of detection (0.27 μg mL−1 for barbital and 0.26 μg mL−1 for phenobarbital), (3) low limits of quantification (0.92 μg mL−1 for barbital and 0.87 μg mL−1 for phenobarbital), (4) good precision (R.S.D. of intra-day and inter-day less than 5.38% for barbital and 1.67% for phenobarbital, respectively) and (5) high recoveries at three concentration levels (90.27–106.36% for barbital and 93.05–113.60% for phenobarbital in urine). The method is simple, sensitive and efficient, and can fit to the need of clinical and forensic toxicology.  相似文献   

2.
Yazdi AS  Razavi N  Yazdinejad SR 《Talanta》2008,75(5):1293-1299
Dispersive liquid–liquid microextraction (DLLME) coupled with gas chromatography–flame ionization detection (GC–FID) was applied for the determination of two tricyclic antidepressant drugs (TCAs), amitriptyline and nortriptyline, from water samples. This method is a very simple and rapid method for the extraction and preconcentration of these drugs from environmental sample solutions. In this method, the appropriate mixture of extraction solvent (18 μL Carbon tetrachloride) and disperser solvent (1 mL methanol) are injected rapidly into the aqueous sample (5.0 mL) by syringe. Therefore, cloudy solution is formed. In fact, it is consisted of fine particles of extraction solvent which is dispersed entirely into aqueous phase. The mixture was centrifuged and the extraction solvent is sedimented on the bottom of the conical test tube. 2.0 μL of the sedimented phase is injected into the GC for separation and determination of TCAs. Some important parameters, such as kind of extraction and disperser solvent and volume of them, extraction time, pH and ionic strength of the aqueous feed solution were optimized. Under the optimal conditions, the enrichment factors and extraction recoveries were between 740.04–1000.25 and 54.76–74.02%, respectively. The linear range was (0.005–16 μg mL−1) and limits of detection were between 0.005 and 0.01 μg mL−1 for each of the analytes. The relative standard deviations (R.S.D.) for 4 μg mL−1 of TCAs in water were in the range of 5.6–6.4 (n = 6). The performance of the proposed technique was evaluated for determination of TCAs in blood plasma.  相似文献   

3.
A two-dimensional biomimetic optrode for the detection and quantification of uranium in natural waters was fabricated. The sensing element was designed by the inclusion of uranyl ion imprinted polymer particles into polymethyl methacrylate followed by casting a thin film on a glass slide without any plasticizer. The ion imprinted polymer material was prepared via covalent immobilization of the newly synthesised ligand 4-vinyl phenylazo-2-naphthol by thermal polymerization. Operational parameters such as pH, response time and the amount of sensing material were optimized. The response characteristics of the imprinted and the corresponding non-imprinted polymer inclusion optrodes of uranium were compared under optimum conditions. The imprinted polymer inclusion optrode responds linearly to uranium in the concentration range 0–1.0 μg mL−1 with a detection limit of 0.18 μg mL−1, which is much better than the solution studies using 4-vinyl phenylazo-2-naphthol (1.5 μg mL−1). Triplicate determinations of 100 μg of uranium(VI) present in 250 mL of solution gave a mean absorbance of 0.018 with a relative standard deviation of 8.33%. The superior sensitivity of imprinted polymer inclusion optrode is exemplified by lower detection limits and broader dynamic range over non-imprinted polymer inclusion optrode. The developed imprinted polymer inclusion optrode was found to give stable and precise response for 3 months and can be used without any loss in sensitivity. The applicability for analysing ground, lake and tap-water samples collected in the vicinity of uranium deposits was successfully demonstrated.  相似文献   

4.
A new sensitive and selective preconcentration-fluorimetric method for determination of terazosin based on its native fluorescence was developed. The analyte, initially present in aqueous matrix, was treated with an extractive non-ionic surfactant solution and separated by the clouding phenomenon. The optimum analytical conditions for terazosin assay were established. Under these conditions, linear calibration curves were obtained over the range of 1 × 10−5 to 7.0 μg mL−1 with detection and quantification limits of 1.11 × 10−5 and 3.7 × 10−5 μg mL−1, respectively. Additionally, the binding constant (KB) for the terazosin-PONPE 7.5 system was determined given a value of 1028 L mol−1. The developed coupled methodology, which thoroughly satisfies the typical requirements for pharmaceutical control processes, was proved to be appropriate for monitoring terazosin in actual pharmaceutical formulations and biological fluid sample. The results were validated by recovery test and by comparison with other reported methods, being highly satisfactory.  相似文献   

5.
A novel sequential injection (SI) method was developed for the determination of penicillamine (PA) and ephedrine (EP) based on the reaction of these drugs with tris(bipyridyl)ruthenium(II) (Ru(bpy)32+) and peroxydisulfate (S2O82−) in the presence of light. Derivatization of PA and EP with aldehydes has resulted in a significant enhancement of the chemiluminescence emission signal by at least 25 times for PA and 12 times for EP, leading to better sensitivities and lower detection limits for both drugs. The instrumental setup utilized a syringe pump and a multiposition valve to aspirate the reagents, (Ru(bpy)32+ and S2O82−), and a peristaltic pump to propel the sample. The experimental conditions affecting the derivatization reaction and the chemiluminescence reaction were systematically optimized using the univariate approach. Under the optimum conditions linear calibration curves between 0.2–24 μg mL−1 for PA and 0.2–20 μg mL−1 for EP were obtained. The detection limits were 0.1 μg mL−1 for PA and 0.03 μg mL−1 for EP. The procedure was applied to the analysis of PA and EP in pharmaceutical products and was found to be free from interferences from concomitants usually present in these preparations.  相似文献   

6.
Du D  Ding J  Cai J  Zhang J  Liu L 《Talanta》2008,74(5):1337-1343
Gold nanoparticles (AuNPs) were synthesized in situ and electrodeposited onto Au substrate. The AuNPs modified interface facilitates electron transfer across self-assembled monolayers (SAMs) of 11-mercaptoundecanoic acid (MUA). After activation of surface carboxyl groups with 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide and N-hydroxysuccinimide, the interface displayed good stability for immobilization of biomolecules. These modification processes were characterized by contact angle measurement, cyclic voltammetry and electrochemical impedance spectra. The immobilized acetylcholinesterase (AChE), as a model, showed excellent activity to its substrate, leading to a stable AChE biosensor. Under the optimal experimental conditions, the inhibition of malathion on AChE biosensor was proportional to its concentration in two ranges, from 0.001 to 0.1 μg mL−1 and from 0.1 to 25 μg mL−1, with detection limit of 0.001 μg mL−1. The simple method showed good reproducibility and acceptable stability, which had potential application in biosensor design.  相似文献   

7.
An analytical method for analysing acrylamide in coffee was validated. The analysis of prepared coffee includes a comprehensive clean-up using multimode solid-phase extraction (SPE) by automatic SPE equipment and detection by liquid chromatography tandem mass spectrometry using electrospray in the positive mode. The recoveries of acrylamide in ready-to-drink coffee spiked with 5 and 10 μg l−1 were 96±14% and 100±8%, respectively. Within laboratory reproducibility for the same spiking levels were 14% and 9%, respectively. Coffee samples (n = 25) prepared twice by coffee machines and twice by a French Press Cafetière coffee maker contained 8±3 μg l−1 and 9±3 μg l−1 acrylamide. Five ready-to-drink instant coffee prepared twice contained 8±2 μg l−1. Hence, the results do not show significant differences in the acrylamide contents in ready-to-drink coffee prepared by coffee machine, French Press or from instant coffee. Medium roasted coffee contained more acrylamide (10 μg l−1) than dark roasted coffee (5 μg l−1). Males aged 35–45 years, drinking on average 1.1 l coffee per day are exposed to the highest doses of acrylamide from coffee. The dietary intake of acrylamide from coffee comprises, on an average, 10 μg day−1 for males and 9 μg day−1 for females aged 35–45 years. Probabilistic modelling of the exposure of Danish consumers (all adults) to acrylamide from coffee shows a mean exposure of 6.5 μg day−1 and a 95 percentile of 18 μg day−1.  相似文献   

8.
A new rapid flow injection procedure for the simultaneous determination of nitrate, nitrite and ammonium in single flow injection analysis system is proposed. The procedure combines on-line reduction of nitrate to nitrite and oxidation of ammonium to nitrite with spectrophotometric detection of nitrite by using the Griess-llosvay reaction. The formed azo dye was measured at 543 nm. The influence of reagent concentration and manifold parameters were studied. Nitrite, nitrate and ammonium can be determined within the range of 0.02–1.60 μg mL−1, 0.02–1.60 μg mL−1 and 0.05–1.40 μg mL−1, respectively. R.S.D. values (n = 10) were 2.66; 1.41 and 3.58 for nitrate, nitrite and ammonium, respectively. This procedure allows the determination and speciation of inorganic nitrogen species in soils with a single injection in a simple way, and high sampling rate (18 h−1). Detection limits of 0.013, 0.046 and 0.047 μg mL−1were achieved for nitrate, nitrite and ammonium, respectively. In comparison with others methods, the proposed one is more simple, it uses as single chromogenic reagent less injection volume (250 mL in stead of 350 mL) and it has a higher sampling rate.  相似文献   

9.
Soylak M  Tuzen M  Mendil D  Turkekul I 《Talanta》2006,70(5):1129-1135
A solid phase extraction procedure based on biosorption of copper(II), lead(II), zinc(II), iron(III), nickel(II) and cobalt(II) ions on Aspergillus fumigatus immobilized Diaion HP-2MG has been investigated. The analytical conditions including amounts of A. fumigatus, eluent type, flow rates of sample and eluent solutions were examined. Good recoveries were obtained to the spiked natural waters. The influences of the concomitant ions on the retentions of the analytes were also examined. The detection limits (3sigma, N = 11) were 0.30 μg l−1 for copper, 0.32 μg l−1 for iron, 0.41 μg l−1 for zinc, 0.52 μg l−1 for lead, 0.59 μg l−1 for nickel and 0.72 μg l−1 for cobalt. The relative standard deviations of the procedure were below 7%. The validation of the presented procedure is performed by the analysis of three standard reference materials (NRCC-SLRS 4 Riverine Water, SRM 1515 Apple leaves and GBW 07605 Tea). The procedure was successfully applied for the determination of analyte ions in natural waters microwave digested samples including street dust, tomato paste, black tea, etc.  相似文献   

10.
3-Succinylaconitine was conjugated with bovine serum albumin (BSA) for use as an immunogen for the preparation of a monoclonal antibody (MAb) against aconitine (Aco). Splenocytes from mice immunized with the Aco-BSA conjugate were fused with an aminopterin-sensitive mouse myeloma cell line, P3-X63-Ag8-653, and a hybridoma secreting a MAb against Aco was successfully obtained. The MAb cross-reacted with mesaconitine, hypaconitine and jesaconitine, which are Aco-type alkaloids, but not with any other compounds examined. The full measurement range of an enzyme-linked immunosorbent assay (ELISA) developed using the new MAb extended from 100 ng mL−1 to 1.5 μg mL−1 of Aco. The concentrations of Aco-type alkaloids in various Aconiti radixes assayed using the new ELISA method showed good agreement with previous reports.  相似文献   

11.
Analytical procedure for the determination of toxicologically relevant arsenic (the sum of arsenite, arsenate, monomethylarsonate and dimethylarsinate) in urine by flow injection hydride generation and collection of generated inorganic and methylated hydrides on an integrated platform of a transverse-heated graphite atomizer for electrothermal atomic absorption spectrometric determination (ETAAS) is elaborated. Platforms are pre-treated with 2.7 μmol of zirconium and then with 0.10 μmol of iridium which serve both as an efficient hydride sequestration medium and permanent chemical modifier. Arsine, monomethylarsine and dimethylarsine are generated from diluted urine samples (10–25-fold) in the presence of 50 mmol L−1 hydrochloric acid and 70 mmol L−1 l-cysteine. Collection, pyrolysis and atomization temperatures are 450, 500, 2100 and 2150 °C, respectively. The characteristic mass, characteristic concentration and limit of detection (3σ) are 39 pg, 0.078 μg L−1 and 0.038 μg L−1 As, respectively. The limits of detection in urine are ca. 0.4 and 1 μg L−1 with 10- and 25-fold dilutions. The sample throughput rate is 25 h−1. Applications to several urine CRMs are given.  相似文献   

12.
Nie F  Lu J 《Talanta》2008,74(5):1242-1246
Calcein was found to be able to use as chemiluminescence reagent and post-chemiluminescence was observed when fenfluramine was injected into the mixture after the CL reaction of calcein–potassium permanganate. Based on this phenomenon, a flow injection CL method was established for the determination of fenfluramine. The possible CL mechanism was proposed. The CL intensity was correlated linearly with the concentration of fenfluramine over the range of 1.0 × 10−7 to 6.0 × 10−6 g mL−1 and the detection limit was 6 × 10−8 g mL−1. The relative standard deviation was 2.2% for 5.0 × 10−7 g mL−1 fenfluramine (n = 11). This method was applied to the determination of fenfluramine in weight-reducing tonic successfully.  相似文献   

13.
Ruengsitagoon W 《Talanta》2008,74(5):1236-1241
A simple reversed flow injection colourimetric procedure for determining iron(III) was proposed. It is based on the reaction between iron(III) with chlortetracycline, resulting in an intense yellow complex with a suitable absorption at 435 nm. A 200 μl chlortetracycline reagent solution was injected into the phosphate buffer stream (flow rate 2.0 ml min−1) which was then merged with iron(III) standard or sample in dilute nitric acid stream (flow rate 1.5 ml min−1). Optimum conditions for determining iron(III) were investigated by univariate method. Under the optimum conditions, a linear calibration graph was obtained over the range 0.5–20.0 μg ml−1. The detection limit (3σ) and the quantification limit (10σ) were 0.10 and 0.82 μg ml−1, respectively. The relatives standard deviation of the proposed method calculated from 12 replicate injections of 2.0 and 10.0 μg ml−1 iron(III) were 0.43 and 0.59%, respectively. The sample throughput was 60 h−1. The proposed method has been satisfactorily applied to the determination of iron(III) in natural waters.  相似文献   

14.
Khaled E 《Talanta》2008,75(5):1167-1174
A simple, rapid and accurate method for the spectrophotometric determination of terfenadine has been developed. The proposed method based on the charge-transfer reactions of terfenadine, as n-electron donor, with 7,7,8,8-tetracyanoquinodimethane (TCNQ), tetracyanoethylene (TCNE), 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ) or 2,5-dichloro-3,6-dihydroxy-1,4-benzoquinone (chloranilic acid, p-CLA) as π-acceptors to give highly colored complexes. The experimental conditions such as reagent concentration, reaction solvent and time have been carefully optimized to achieve the highest sensitivity. Beer's law is obeyed over the concentration ranges of 3–72, 3–96, 12–168 and 24–240 μg mL−1 terfenadine using TCNQ, TCNE, DDQ and p-CLA, respectively, with correlation coefficients 0.9999, 0.9974, 0.9997 and 0.9979 and detection limits 0.3, 0.4, 2.6 and 12.3 μg mL−1, for the reagents in the same order. DDQ and p-CLA react spontaneously with terfenadine to give colored complexes that can be applied for the flow injection analysis of terfenadine in the concentration ranges 2.4–120 and 24–240 μg with correlation coefficients 0.9990 and 0.9985 and detection limits 0.8 and 2.7 μg for DDQ and p-CLA, respectively, in addition to the high sampling through output of 40 sample h−1.  相似文献   

15.
A procedure for arsenic species fractionation in alga samples (Sargassum fulvellum, Chlorella vulgaris, Hizikia fusiformis and Laminaria digitata) by extraction is described. Several parameters were tested in order to evaluate the extraction efficiency of the process: extraction medium, nature and concentration (tris(hydroxymethyl)aminomethane, phosphoric acid, deionised water and water/methanol mixtures), extraction time and physical treatment (magnetic stirring, ultrasonic bath and ultrasonic focussed probe). The extraction yield of arsenic under the different conditions was evaluated by determining the total arsenic content in the extracts by ICP-AES. Arsenic compounds were extracted in 5 mL of water by focussed sonication for 30 s and subsequent centrifugation at 14,000 × g for 10 min. The process was repeated three times. Extraction studies show that soluble arsenic compounds account for about 65% of total arsenic.

An ultrafiltration process was used as a clean-up method for chromatographic analysis, and also allowed us to determine the extracted arsenic fraction with a molecular weight lower than 10 kDa, which accounts for about 100% for all samples analysed.

Speciation studies were carried out by HPLC–ICP-AES. Arsenic species were separated on a Hamilton PRP-X100 column with 17 mM phosphate buffer at pH 5.5 and 1.0 mL min−1 flow rate. The chromatographic method allowed us to separate the species As(III), As(V), MMA and DMA in less than 13 min, with detection limits of about 20 ng of arsenic per species, for a sample injection volume of 100 μL. The chromatographic analysis allowed us to identify As(V) in Hizikia (46 ± 2 μg g−1), Sargassum (38 ± 2 μg g−1) and Chlorella (9 ± 1 μg g−1) samples. The species DMA was also found in Chlorella alga (13 ± 1 μg g−1). However, in Laminaria alga only an unknown arsenic species was detected, which eluted in the dead volume.  相似文献   


16.
In this paper we have coupled, for the first time, chemiluminescent detection with multicommuted optosensing principles. This approach has been implemented with the use of a commercial flow cell of 1 mm optical path length filled with an appropriate anionic exchanger gel as chemiluminescence sensing phase. The cell was placed in front of the window of the photosensor module of a home-made luminometer developed in our laboratory and a flat mirror was stuck on the back of the cell. The suitability of using chemiluminescence as detection technique in multicommuted flow-through optosensors has been demonstrated: the determination of salicylic acid by simple oxidation with permanganate on the sensing solid phase was chosen as model reaction. The proposed system allows the determination of salicylic acid in pharmaceuticals, with a sample frequency as high as even 60 samples h−1 and showing a detection limit of 0.30 μg mL−1, the linear response range is 1–30 μg mL−1 and the R.S.D. is 3.1%. Satisfactory results have been obtained when applying the sensor to pharmaceuticals. The accuracy of the proposed methodology has been tested by using a reference method.  相似文献   

17.
Yang J  Guan J  Pan L  Jiang K  Cheng M  Li F 《Analytica chimica acta》2008,610(2):263-267
Simple and efficient analytical HPLC methods using Chiralpak AS-H as chiral stationary phase were developed for direct enantioseparation of 11 novel phenylethanolamine derivatives. The chromatographic experiments were performed in normal phase mode with n-hexane–ethanol–triethylamine (TEA) as mobile phase. Excellent baseline enantioseparation was obtained for most of compounds. The effects of the concentration of organic modifiers and column temperature were studied for the enantiomeric separation. The mechanism of chiral recognition was discussed based on the relationship between the thermodynamic parameters and structures of compounds. It was found that the enantioseparations were all enthalpy driven, and the tert-butyl groups of compounds had significant influence on the chiral recognition. Trantinterol enantiomers were resolved (Rs = 2.73) within 14 min using n-hexane–ethanol–TEA (98:2:0.1, v/v/v) as mobile phase with a flow rate of 0.8 mL min−1 at 30 °C. The optimized method was validated for linearity, precision, accuracy and stability in solution and proved to be robust. The limits of detection (LOD) and quantification (LOQ) for (+)-trantinterol were 0.15 and 0.46 μg mL−1. The method was applied for enantiomeric impurity determination of (−)-trantinterol bulk samples.  相似文献   

18.
Zhou X  Xing D  Zhu D  Tang Y  Jia L 《Talanta》2008,75(5):1300-1306
Enrofloxacin (ENR) is a fluoroquinolone developed exclusively for the use in veterinary practice for the treatment of respiratory and gastrointestinal infections, and ciprofloxacin (CIP) is its main active metabolite. Their contents are regulated by the EU Council Regulation no. 2377/90 in animal edible tissues. We developed a sensitive and rapid method for the determination of ENR and CIP by capillary electrophoresis (CE) with electrochemiluminescence (ECL) detection. The method is based on the detection of aliphatic tertiary or secondary amino moieties in ENR and CIP with end-column tris(2,2-bipyridyl)ruthenium(II) electrochemiluminescence. Parameters that affect separation and detection were optimized. Under the optimized conditions, the calibration functions were linear in the range of 0.03–1 μg ml−1 for ENR and 0.05–1.2 μg ml−1 for CIP. The detection limits of ENR and CIR were 10 ng ml−1 and 15 ng ml−1, respectively, based on the signal-to-noise ratio of 3. The relative standard derivations of the peak height and the migration time for ENR and CIP were less than 4.13%. The developed method was successfully applied to determine ENR and CIP in milk with a solid-phase extraction procedure.  相似文献   

19.
Hydrogen peroxide in basic media is proposed as a means for dissolving whole blood samples to be analyzed by electrothermal atomization atomic absorption spectrometry, ET AAS. Approximately 2 g of the whole blood sample were directly weighed in a 150 mL volumetric flask; 3 mL of a NaOH 0.2 mol L−1 solution, two drops of 1-octanol, as an antifoaming agent, and 1 mL of 30% volume hydrogen peroxide were added to the flask to promote oxidation. The solution was then manually shaken and after approximately three minutes of shaking, a clear solution, with no apparent suspended solids or greasy layers, was obtained. Distilled-deionized water was used to complete the volume. Ten μL of the resulting solution along with 10 μL of a solution containing 5000 mg L−1 of NH4H2PO4 and 300 mg L−1 of Mg(NO3)2 as a modifier, were injected into transversely heated graphite tubes for lead determination. Both aqueous standards and standard addition calibration curves produced results not significantly different at a 95% confidence limit level. Accuracy of the measurements was assessed by analysis of the IAEA A-13 (concentration of trace and minor elements in freeze dried animal blood) standard reference material containing 0.18 mg L−1 lead on a dry basis and by means of recovery tests. Analysis of the IAEA A-13 standard produced 0.17 ± 0.02 mg L−1 lead on a dry basis; recovery tests afforded values from 95 to 105%. Ten consecutive measurements of a 5 ppb lead solution gave a characteristic mass of 47.2 pg and a (3S) detection limit of 1.77 μg L−1 Pb. Results obtained from analysis of whole blood samples of volunteer donors covered a lead concentration range between 8 and 21 μg L−1 with a mean value of 11.9 ± 4.7 μg L−1.  相似文献   

20.
Bismuth as BiCl4 and BH4 ware successively retained in a column (150 mm × 4 mm, length × i.d.) packed with Amberlite IRA-410 (strong anion-exchange resin). This was followed by passage of an injected slug of hydrochloric acid resulting in bismuthine generation (BiH3). BiH3 was stripped from the eluent solution by the addition of a nitrogen flow and the bulk phases were separated in a gas–liquid separator. Finally, bismutine was atomized in a quartz tube for the subsequent detection of bismuth by atomic absorption spectrometry. Different halide complexes of bismuth (namely, BiBr4, BiI4 and BiCl4) were tested for its pre-concentration, being the chloride complexes which produced the best results. Therefore, a concentration of 0.3 mol l−1 of HCl was added to the samples and calibration solutions. A linear response was obtained between the detection limit (3σ) of 0.225 and 80 μg l−1. The R.S.D.% (n = 10) for a solution containing 50 μg l−1 of Bi was 0.85%. The tolerance of the system to interferences was evaluated by investigating the effect of the following ions: Cu2+, Co2+, Ni2+, Fe3+, Cd2+, Pb2+, Hg2+, Zn2+, and Mg2+. The most severe depression was caused by Hg2+, which at 60 mg l−1 caused a 5% depression on the signal. For the other cations, concentrations between 1000 and 10,000 mg l−1 could be tolerated. The system was applied to the determination of Bi in urine of patients under therapy with bismuth subcitrate. The recovery of spikes of 5 and 50 μg l−1 of Bi added to the samples prior to digestion with HNO3 and H2O2 was in satisfactory ranges from 95.0 to 101.0%. The concentrations of bismuth found in six selected samples using this procedure were in good agreement with those obtained by an alternative technique (ETAAS). Finally, the concentration of Bi determined in urine before and after 3 days of treatment were 1.94 ± 1.26 and 9.02 ± 5.82 μg l−1, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号