共查询到20条相似文献,搜索用时 15 毫秒
1.
Rhee TS Mak J Röckmann T Brenninkmeijer CA 《Rapid communications in mass spectrometry : RCM》2004,18(3):299-306
A convenient method is described for analyzing the deuterium/hydrogen (D/H) ratio of atmospheric molecular hydrogen (H(2)) based on mass spectrometric isotope-ratio monitoring. The method requires small amounts of air ( approximately 300 mL STP), is operated on-line, and comprises four steps: (1). the condensation of the air matrix at approximately 40 K; (2). the collection of the non-condensed components of the air sample (H(2), Ne, He, and traces of N(2)) in a 5 A molecular sieves pre-concentration trap at approximately 63 K; (3). gas chromatographic purification of H(2) in a flow of He; and (4) quantification of the D/H ratio in an isotope-ratio mass spectrometer. The precision of the determination of the D/H ratio is better than 2 per thousand, which is comparable to, or better than, that obtained by conventional duel-inlet off-line analysis. There are, however, discrepancies relative to the D/H ratios determined by conventional duel-inlet analysis. This is due to differences in peak shape between reference and sample air, depending on the amount of H(2) injected. Consequently, calibration runs are required. After the calibration of the system, we obtained an accuracy of 1.5 per thousand, so that the accumulated uncertainty is estimated to be less than 4 per thousand. The method also allows determination of the H(2) concentration, with an uncertainty estimated to be 2%. 相似文献
2.
3.
Wu Wang Li Li Huaijian Li Dongping Zhang Shen Wen Wanglu Jia Bangjin Wang Guo ying Sheng Jiamo Fu 《Rapid communications in mass spectrometry : RCM》2009,23(17):2675-2678
The stable carbon isotope compositions of tetrols, erythritol and threitol were determined by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). Using four tetrols with various δ13C values derivatized by methylboronic acid, the carbon isotope analysis method achieved excellent reproducibility and high accuracy. There was no carbon isotopic fractionation during the derivatization processes. The differences in the carbon isotopic compositions of methylboronates between the measured and calculated ranged from ?0.20 to 0.12‰, within the specification of the GC/C/IRMS system. It was demonstrated that δ13C values of tetrols could be calculated by a simple mass balance equation between tetrols, methylboronic acid, and methylboronates. The analogous 2‐methyltetrols, marker compounds of photooxidation products of atmospheric isoprene, should have similar behavior using the same derivatization reagent. This method may provide insight on sources and sinks of atmospheric isoprene. Copyright © 2009 John Wiley & Sons, Ltd. 相似文献
4.
5.
同位素质谱与无机质谱分析 总被引:1,自引:0,他引:1
本文是《分析试验室》定期评述中“无机质谱分析”课题的第二篇评述文章,它增加了同位素质谱分析的内容,故将题目改为现今题目,它综述了1985年~1990年间同位素质谱和无机质谱的发展概况。其中包括同位素示踪、同位素稀释、火花源质谱、二次离子质谱、等离子体质谱等。内容以国内为主,也收集了少量代表学科先进水平的外国文献。 相似文献
6.
The most precise method of chlorine isotope analysis described to date is based on the isotope ratio mass spectrometry (IRMS) of chlorine quantitatively converted into chloromethane, CH3Cl. This gas can be produced from several chlorine‐containing compounds and analyzed by IRMS. However, the mass spectrum of chloromethane is rather complicated and the ratio of the most abundant ions (mass‐52/mass‐50) differs from the 37Cl/35Cl isotope ratio. This difference becomes significant when the δ exceeds 10‰. Moreover, the electron ionization source yields approximately 80% of all the ionic species at the useful masses 50 and 52. To overcome these drawbacks, we have devised a negative ion mass spectrometer which retains all the best features of IRMS, including a dual‐inlet system with changeover valve, dual collector assembly and CH3Cl gas as analyte. In the modified ion source we have replaced the ionization chamber with an electron beam by a metal tube with a hot metal filament inside it. Within this tube the 35Cl? and 37Cl? ions are produced with an efficiency dependent on the filament material and its temperature. No other ionic species were found in the mass spectrum except of traces at masses 26 and 28 at ppm levels, probably due to the formation of CN? and CO?. The minimal amount of Cl used in our method is of the order of 5 µmol (3 mg AgCl) and the precision is better than 0.005‰ (1σ). Copyright © 2009 John Wiley & Sons, Ltd. 相似文献
7.
Adam G. West Gregory R. Goldsmith Paul D. Brooks Todd E. Dawson 《Rapid communications in mass spectrometry : RCM》2010,24(14):1948-1954
The use of isotope ratio infrared spectroscopy (IRIS) for the stable hydrogen and oxygen isotope analysis of water is increasing. While IRIS has many advantages over traditional isotope ratio mass spectrometry (IRMS), it may also be prone to errors that do not impact upon IRMS analyses. Of particular concern is the potential for contaminants in the water sample to interfere with the spectroscopy, thus leading to erroneous stable isotope data. Water extracted from plant and soil samples may often contain organic contaminants. The extent to which contaminants may interfere with IRIS and thus impact upon data quality is presently unknown. We tested the performance of IRIS relative to IRMS for water extracted from 11 plant species and one organic soil horizon. IRIS deviated considerably from IRMS for over half of the samples tested, with deviations as large as 46‰ (δ2H) and 15.4‰ (δ18O) being measured. This effect was reduced somewhat by using activated charcoal to remove organics from the water; however, deviations as large as 35‰ (δ2H) and 11.8‰ (δ18O) were still measured for these cleaned samples. Interestingly, the use of activated charcoal to clean water samples had less effect than previously thought for IRMS analyses. Our data show that extreme caution is required when using IRIS to analyse water samples that may contain organic contaminants. We suggest that the development of new cleaning techniques for removing organic contaminants together with instrument‐based software to flag potentially problematic samples are necessary to ensure accurate plant and soil water analyses using IRIS. Copyright © 2010 John Wiley & Sons, Ltd. 相似文献
8.
Farmer NL Meier-Augenstein W Kalin RM 《Rapid communications in mass spectrometry : RCM》2005,19(22):3182-3186
Isotope ratio mass spectrometry (IRMS) was used to assess what contribution the technique could make towards the comparative analysis of matchstick samples within the 'normal' framework of a forensic investigation. A method was developed to allow the comparison of samples submitted as a result of an investigation, with the added advantage of rapid sample turn-around expected within this field. To the best of our knowledge this is the first time that wooden safety matches have been analysed using IRMS. In this particular case, bulk stable isotope analysis carrried out on a 'like-for-like' basis could demonstrate conclusively that matches seized from a suspect were different from those collected at the scene of crime. The maximum delta13C variability observed within one box was 2.5 per thousand, which, in conjunction with the error of measurement, was regarded to yield too wide an error margin as to permit differentiation of matchsticks based on 13C isotopic composition alone given that the 'natural' 13C abundance in wood ranges from -20 to -30 per thousand. However, from the delta2H values obtained for crime scene matches and seized matches of -114.5 per thousand and -65 per thousand, respectively, it was concluded that the matches seized were distinctly different from those collected at the crime scene. 相似文献
9.
Desroches MC Mathurin JC Richard Y Delahaut P de Ceaurriz J 《Rapid communications in mass spectrometry : RCM》2002,16(5):370-374
The detection of exogenous 19-norandrosterone (19-NA) in urines was investigated by using gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS). 19-NA is, for the first time to our knowledge, isolated from urinary matrix by specific immunoaffinity chromatography (IAC) before analysis. The sample preparation consisted of a preliminary purification of urine by solid-phase extraction after hydrolysis by beta-glucuronidase. Unconjugated 19-NA was thus isolated by IAC and directly analysed by GC/C/IRMS. Optimisation of IAC purification was achieved and the reliability of the technique for anti-doping control is discussed. 相似文献
10.
Comparison of gas chromatography/isotope ratio mass spectrometry and liquid chromatography/isotope ratio mass spectrometry for carbon stable‐isotope analysis of carbohydrates 下载免费PDF全文
Tanja C. W. Moerdijk‐Poortvliet Henk Schierbeek Marco Houtekamer Tom van Engeland Delphine Derrien Lucas J. Stal Henricus T. S. Boschker 《Rapid communications in mass spectrometry : RCM》2015,29(13):1205-1214
11.
Yuri V. Dublyansky Christoph Spötl 《Rapid communications in mass spectrometry : RCM》2009,23(17):2605-2613
An analytical line for stable isotope analyses of water recovered from fluid inclusions in minerals was built and successfully tested. The line is based on the principle of continuous‐flow analysis of water via high‐temperature reduction on glassy carbon. It includes a custom‐designed set of high‐efficiency crushers and a cryo‐focusing cell. This paper provides details of the line design and discusses strategies for line conditioning and mitigation of memory effects. The line allows measurements of hydrogen and oxygen isotopes during a single acquisition. The precision of the analyses depends on the amount of water released from the inclusions. The best results are obtained for samples containing at least 0.1–0.2 µL (0.06–0.11 µmol) H2O. For such samples precision is better than 1.5‰ for δD and 0.5‰ for δ18O (1σ). Smaller amounts of water can be measured but at lower precision. Analyses of modern calcite formed under stable conditions in a deep cave allowed assessment of the accuracy of the analyses. The δD values measured in fluid inclusions of this working standard match the δD value of the parent water, and the oxygen isotope values agree within ca. 0.5‰. This indicates that fluid inclusions trapped in calcite at near‐ambient temperatures (e.g. speleothems and low‐temperatures phreatic calcite) faithfully preserve the original isotopic composition of the parent waters. Copyright © 2009 John Wiley & Sons, Ltd. 相似文献
12.
Nelson ST 《Rapid communications in mass spectrometry : RCM》2000,14(4):293-297
Due to the small amounts of sample gas involved in continuous flow mass spectrometric analysis, care should be taken to evaluate the influence of sample containers on the carbon and oxygen isotope ratios of samples. Data indicate that Na-glass and borosilicate glass vials, equipped with butyl rubber septa, can cause significant changes in the isotopic composition of CO(2) gas, even where sample gases are stored within the vial for less than one day. The magnitude of these changes varies from vial to vial. Given the leverage that contamination can potentially exert on small gas samples, each researcher should carefully evaluate the effect of sample vials in order to eliminate unknown and unwanted changes in the composition of samples. Copyright 2000 John Wiley & Sons, Ltd. 相似文献
13.
Zhao L Xiao H Zhou J Wang L Cheng G Zhou M Yin L McCabe MF 《Rapid communications in mass spectrometry : RCM》2011,25(20):3071-3082
As an alternative to isotope ratio mass spectrometry (IRMS), the isotope ratio infrared spectroscopy (IRIS) approach has the advantage of low cost, continuous measurement and the capacity for field‐based application for the analysis of the stable isotopes of water. Recent studies have indicated that there are potential issues of organic contamination of the spectral signal in the IRIS method, resulting in incorrect results for leaf samples. To gain a more thorough understanding of the effects of sample type (e.g., leaf, root, stem and soil), sample species, sampling time and climatic condition (dry vs. wet) on water isotope estimates using IRIS, we collected soil samples and plant components from a number of major species at a fine temporal resolution (every 2 h for 24–48 h) across three locations with different climatic conditions in the Heihe River Basin, China. The hydrogen and oxygen isotopic compositions of the extracted water from these samples were measured using both an IRMS and an IRIS instrument. The results show that the mean discrepancies between the IRMS and IRIS approaches for δ18O and δD, respectively, were: –5.6‰ and ?75.7‰ for leaf water; –4.0‰ and ?23.3‰ for stem water; –3.4‰ and ?28.2‰ for root water; ?0.5‰ and –6.7‰ for xylem water; –0.06‰ and ?0.3‰ for xylem flow; and ?0.1‰ and 0.3‰ for soil water. The order of the discrepancy was: leaf > stem ≈ root > xylem > xylem flow ≈ soil. In general, species of the same functional types (e.g., woody vs. herbaceous) within similar habitats showed similar deviations. For different functional types, the differences were large. Sampling at nighttime did not remove the observed deviations. Copyright © 2011 John Wiley & Sons, Ltd. 相似文献
14.
15.
Richard J. Caimi J. Thomas Brenna 《Journal of the American Society for Mass Spectrometry》1996,7(6):605-610
We demonstrate the high precision C isotopic analysis of a series of purified albumins by liquid chromatography-combustion isotope ratio mass spectrometry (IRMS) by using direct aqueous liquid injection. Albumins from 18 species and albumens from chicken and turkey egg were obtained from a commercial source and shown to be of > 98% purity by capillary zone electrophoresis and high-performance liquid chromatography. One microliter of an aqueous protein solution with a total of < 40-pmol protein (2. 5 µg), which contained about 150-nmol C, was injected directly into a flowing stream of high-performance liquid chromatography grade water. The solution passed through a pneumatic nebulizer, was sprayed onto a moving wire, passed through a drying oven, and was combusted in a furnace. After the water of combustion was removed, the resulting CO2 gas was directed to a high precision IRMS instrument operated in continuous flow mode. The average precision across the 20 samples analyzed was SD(δ 13C)=0.45%., and the average accuracy was δ13C < 0.4%. compared to aliquots analyzed by conventional preparation by using combustion tubes and dual inlet analysis. The observed isotope ratio range was about ?22.5%. < δ 13CPDB < ?16%. as expected for modern materials from a natural source. These results demonstrate rapid, high precision, and accurate C isotopic analysis of untreated macromolecules in an aqueous stream by liquid source IRMS. 相似文献
16.
17.
Site-specific carbon isotope composition of organic compounds can provide useful information on their origin and history in natural environments. Site-specific isotope analyses of small amounts of organic compounds (sub-nanomolar level), such as short-chain carboxylic acids and amino acid analogues, have been performed using gas chromatography/pyrolysis/isotope ratio mass spectrometry (GC/pyrolysis/IRMS). These analyses were previously limited to volatile compounds. In this study, site-specific carbon isotope analysis has been developed for non-volatile aromatic carboxylic acids at sub-micromolar level by decarboxylation using a continuous flow elemental analysis (EA)/pyrolysis/IRMS technique. Benzoic acid, 2-naphthylacetic acid and 1-pyrenecarboxylic acid were pyrolyzed at 500-1000 degrees C by EA/pyrolysis/IRMS to produce CO2 for delta13C measurement of the carboxyl group. These three aromatic acids were most efficiently pyrolyzed at 750 degrees C. Conventional sealed-tube pyrolysis was also conducted for comparison. The delta13C values of CO2 generated by the continuous flow technique were within 1.0 per thousand of those performed by the conventional technique, indicating that the new continuous flow technique can accurately analyze the carbon isotopic composition of the carboxyl group in aromatic carboxylic acids. The new continuous flow technique is simple, rapid and uses small sample sizes, so this technique will be useful for characterizing the isotopic signature of carboxyl groups in organic compounds. 相似文献
18.
Summary A procedure for multielement analysis using mass spectrometry with thermal ionization and the isotope dilution technique was developed. The analytical procedure was checked by investigating the Standard Reference Material no. 1575 Pine Needles supplied by the National Bureau of Standards, USA. The concentrations of the elements Fe, Ni, Cu, Zn, Ga, Rb, Sr, Cd, Tl, and Pb were simultaneously determined in this material. The total amount of ions observed in the mass spectrum originating from the material investigated is discussed. It follows that it might be possible to increase the number of elements determinable simultaneously to 19.
Multielementbestimmung in Umweltproben nach der massenspektrometrischen Isotopenverdünnungsmethode mit thermischer IonisationTeil I: Fichtennadeln
Zusammenfassung Ein Verfahren für die Multielement-analyse nach der massenspektrometrischen Isotopenverdünnungsmethode mit thermischer Ionisation wurde entwickelt. Eine Überprüfung des Analysenverfahrens erfolgte durch die Untersuchung des Standardreferenzmaterials Nr. 1575 Pine Needles, National Bureau of Standards, USA. In diesem Material konnten die Konzentrationen der Elemente Fe, Ni, Cu, Zn, Ga, Rb, Sr, Cd, Tl und Pb simultan bestimmt werden. Die insgesamt im Massenspektrum beobachteten, zur Probe gehörenden Ionen werden diskutiert. Hieraus folgt, daß es möglich sein könnte, die Zahl der gleichzeitig zu bestimmenden Elemente bis auf 19 zu vergrößern.相似文献
19.
20.
Moran JJ Newburn MK Alexander ML Sams RL Kelly JF Kreuzer HW 《Rapid communications in mass spectrometry : RCM》2011,25(9):1282-1290
Stable isotope analysis permits the tracking of physical, chemical, and biological reactions and source materials at a wide variety of spatial scales. We present a laser ablation isotope ratio mass spectrometry (LA‐IRMS) method that enables δ13C measurement of solid samples at 50 µm spatial resolution. The method does not require sample pre‐treatment to physically separate spatial zones. We use laser ablation of solid samples followed by quantitative combustion of the ablated particulates to convert sample carbon into CO2. Cryofocusing of the resulting CO2 coupled with modulation in the carrier flow rate permits coherent peak introduction into an isotope ratio mass spectrometer, with only 65 ng carbon required per measurement. We conclusively demonstrate that the measured CO2 is produced by combustion of laser‐ablated aerosols from the sample surface. We measured δ13C for a series of solid compounds using laser ablation and traditional solid sample analysis techniques. Both techniques produced consistent isotopic results but the laser ablation method required over two orders of magnitude less sample. We demonstrated that LA‐IRMS sensitivity coupled with its 50 µm spatial resolution could be used to measure δ13C values along a length of hair, making multiple sample measurements over distances corresponding to a single day's growth. This method will be highly valuable in cases where the δ13C analysis of small samples over prescribed spatial distances is required. Suitable applications include forensic analysis of hair samples, investigations of tightly woven microbial systems, and cases of surface analysis where there is a sharp delineation between different components of a sample. Copyright © 2011 John Wiley & Sons, Ltd. 相似文献