首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 437 毫秒
1.
Summary Toxic metals in sea and inland waters have become a significant research topic in the chemistry of the marine and inland aquatic environment. Advanced polarographic and voltammetric methods offer an expectional efficient and versatile approach to the determination, speciation and physicochemical characterization of those metals. These potentialities are reflected by a reliable method based on differential pulse anodic stripping at an in situ mercury film coated rotatable glassy carbon electrode for the simultaneous determination of ultra-trace levels of Cd, Pb and Cu dissolved in sea water and inland waters and accumulated in marine organisms.In speciation studies at trace levels differential pulse polarographic measurements revealed the influences of sea water components on the chelation of Cd with NTA and by the application of an advanced version of linear sweep anodic stripping voltammetry kind and stability of Pb-carbonato complexes existing in sea water could be elucidated.
Anwendungen der Polarographie und Voltammetrie in der Chemie des Meeres und der BinnengewässerII. Die polarographische Bestimmung und Speziation toxischer Spurenmetalle in der marinen Umwelt
Zusammenfassung Toxische Metalle im Meer und in Binnengewässern sind eine wichtige Forschungsaufgabe in der Chemie dieser Umweltkompartimente. Fortgeschrittene polarographische und voltammetrische Methoden bieten außergew öhnlich effiziente und vielseitige Möglichkeiten zur Bestimmung, Speziation und physikochemischen Charakterisierung der vorliegenden Metalle. Diese Möglichkeiten werden einmal demonstriert durch eine neue zuverlässige Simultanbestimmung der in Meerwasser und Binnengewässern gelöst vorliegenden Spurengehalte von Cd, Pb und Cu mit inversvoltammetrischer differentieller Pulse-Polarographie an einer in situ mit einem dünnen Quecksilberfilm bedeckten rotierbaren Glaskohleelektrode sowie durch Ermittlung der in marinen Organismen angereicherten Spurenmetallgehalte. In Untersuchungen zur Speziation im Ultraspurenbereich wurden unter Einsatz der differentiellen PulsePolarographie die Einflüsse der Makrokomponenten des Meerwassers auf die Chelierung von Cd mit NTA aufgeklärt und mit Hilfe einer fortgeschrittenen Version der Inversvoltammetrie mit linear sweep die Art und Stabilität der im Meerwasser existierenden Pb-Carbonatokomplexe ermittelt.
Dedicated to Dr. G. C. Barker on his 60th birthday.  相似文献   

2.
Summary The simultaneous determination of cadmium, lead and copper in whole blood by anodic stripping voltammetry is described. Different digestion procedures given in literature were examined. In addition, a sample pretreatment method which did not involve digestion was studied. Based on the experience with these methods two digestion procedures were developed. They utilize digestion with mixtures of nitric, perchloric and sulphuric acids, with and without pressure, respectively. Both methods are suitable for routine analysis of about 20 blood samples per day. Special attention was focussed on the completeness of the digestion, and the magnitude of the blank values. Low blank values and a high sensitivity allowed the determination of cadmium at the sub-ppb level with an electrolysis time of 5 min. The methods, which were controlled by recovery tests, were used to analyze blood samples from unexposed persons, and from workers suspected of exposure to cadmium.
Vergleich von Aufschlußverfahren für die Bestimmung von Schwermetallen (Cd, Cu, Pb) in Blut durch Anodic Stripping Voltammetrie
Zusammenfassung Verschiedene in der Literatur beschriebene Aufschlußverfahren wurden untersucht und zusätzlich ein Probenvorbereitungsverfahren ohne Aufschluß geprüft. Aufgrund der mit diesen Methoden gewonnenen Erfahrungen wurden zwei Aufschlußverfahren entwickelt, bei denen Mischungen von Salpeter-, Perchlor- und Schwefelsäure mit und ohne Anwendung von Druck eingesetzt werden. Beide Methoden eignen sich für die Routineuntersuchung von etwa 20 Blutproben je Tag. Besondere Aufmerksamkeit wurde der Vollständigkeit des Aufschlusses und der Größe der Blindwerte gewidmet. Niedrige Blindwerte und hohe Empfindlichkeit erlaubten die Bestimmung von Cadmium im sub-ppb-Bereich mit einer Elektrolysezeit von 5 min. Die Methoden wurden durch Wiederauffindungstests geprüft und für die Blutuntersuchung von Personen, die der Einwirkung von Cd ausgesetzt waren, sowie solchen, bei denen dies nicht der Fall war, angewendet.
  相似文献   

3.
Summary The determination of lead and cadmium in biological materials was carried out by potentiometric stripping analysis. Supporting electrolyte was a mixture of NaCl and HCl. In the presence of 4% lumatom in methanol, oxidation potentials of –0.46 V for Pb and –0.68 V for Cd were found (vs. SCE). The method was applied to different standard reference materials (leaves, needles, hair) and was also compared with the differential pulse anodic stripping technique. The latter presented considerable difficulties, in particular by the interference of oxygen.
Bestimmung von Blei und Cadmium in biologischem Material durch potentiometrische Stripping-Analyse
Zusammenfassung Als Trägerelektrolyt diente bei diesem Verfahren ein Gemisch von NaCl und HCl. In Gegenwart von 4% Lumatom in Methanol wurden Oxidationspotentiale von –0,46 V für Pb und –0,68 V für Cd (gegen SKE) erhalten. Die Methode wurde auf verschiedene Referenzmaterialien (Laub, Nadeln, Haar) angewendet und auch mit der Differentialpuls-Anodic Stripping-Analyse verglichen. Bei der letzteren ergaben sich größere Schwierigkeiten, hauptsächlich durch störenden Sauerstoff.
  相似文献   

4.
Summary The simultaneous determination of lead, cadmium and zinc in air particulate matter by anodic stripping voltammetry is described. Optimum conditions for the anodic stripping of lead, cadmium and zinc were determined using ammonium tartrate buffer at pH 4.5. Interferences from other metals were not encountered and the estimations were reproducible within a standard deviation of ±10%. Low blank values and high sensitivity of the method allowed the determinations at sub-ppb levels with an electrolysis time of 3–10 min. The geometric mean concentrations of lead, cadmium and zinc at various locations in Greater Bombay during 1979 are also presented.
Simultanbestimmung von Blei, Cadmium und Zink in Aerosolen durch anodische Stripping-Voltammetrie
Zusammenfassung Die optimalen Bedingungen für die Bestimmung von Pb, Cd und Zn unter Verwendung von Ammoniumtartratpuffer pH 4,5 wurden ausgearbeitet. Störungen durch andere Metalle traten bei den untersuchten Aerosolen nicht auf. Die Standardabweichungen lagen bei ±10%. Infolge niedriger Blindwerte und hoher Empfindlichkeit konnten Bestimmungen im sub-ppb-Bereich mit Elektrolysenzeiten von 3–10 min durchgeführt werden. Ein Überblick über die Konzentration der genannten Metalle in der Luft von Bombay wird gegeben.
  相似文献   

5.
Zusammenfassung Die Spurenanalyse zur Bestimmung von Ag, Al, Bi, Co, Cu, Ga, Hg, In, Mn, Ni, Pb, Tl und Zn in reinstem Cadmium wurde ausgearbeitet. Nach dem vorgeschlagenen Schema werden einzelne Gruppen von Spurenelementen durch Extraktion bzw. Mitfällung getrennt und spektrophotometrisch mit Hilfe der folgenden organischen Reagenzien bestimmt: Dithizon, PAN, PAR, Rhodamin B, Brillantgrün, Chromazurol S, 1-Nitroso-2-naphthol und-Furildioxim. Durch die Analyse einer Cadmiumprobe mit dem Zusatz bekannter Mengen der zu bestimmenden Elemente wurden Genauigkeit und Präzision der vorgeschlagenen Methode erwiesen.  相似文献   

6.
Zusammenfassung Es werden die Bedingungen für die indirekte potentiometrische Bestimmung einiger Schwermetalle angegeben, bei der zu einer Lösung des Ions ein Cyanoferrat(III)-überschuß zugegeben und die Lösung mit Hydrochinonmaßlösung titriert wird. Das durch die Reduktion entstehende Cyanoferrat(II) reagiert mit dem Schwermetall unter Bildung des entsprechenden Niederschlages. Das Ende der Titration wird durch den ersten Überschuß von Cyanoferrat(II) in der Lösung angezeigt, der eine starke Potentialänderung im Redox-System Cyanoferrat(II)-Cyanoferrat (III) hervorruft. Die Methode eignet sich für die Bestimmung von Zink, Silber und Indium und hat sich in diesen Fällen auch in Gegenwart einiger Fremdionen bewährt. Versuche, in ähnlicher Weise Ni, Co, Mn, Cu. Cd, Pb, Mo und U zu bestimmen, blieben ohne Erfolg.Dagegen konnte eine potentiometrische Methode zur indirekten Bestimmung yon Chlor, Brom, Hypochlorit, Hypobromit und Bromat ausgearbeitet werden, bei der zu der Probelösung ein Übersehuß an Cyanoferrat(II) zugegeben und die äquivalente Menge Cyanoferrat(III), das durch die Oxydation entsteht, mit Hydrochinonmaßlösung titriert wird.  相似文献   

7.
Summary Systematic investigations were carried out on the heavy metal (Cd, Pb, Cu, Zn, Cr, Ba) pollution of drinking water. The samples were analysed by electrothermal AAS directly and after ATMDTCMIBK chelation extraction preconcentration. Results of both methods were in good agreement. Filterable residue of tap water and sediment of reservoirs in the distribution system were analysed by flame AAS after digestion in acidic medium.Final conclusions as follows: I. At present there is no significant heavy metal pollution originating from surface water. II. Because of the non-aggressive property of the Danube water, no significant dissolution of heavy metals occurs from piping materials, only the zinc content is elevated in some parts of the town. III. Heavy metals are adsorbed on the surface of residue materials and become concentrated in the sediments of the reservoirs. IV. It is desirable from the point of public health that the concentration of filterable residue of tap water is kept under a certain limit.
Systematische Untersuchung der Verunreinigung durch Schwermetalle (Cd, Pb, Cu, Zn, Cr, Ba) im Trinkwasser mit Hilfe von AAS-Methoden
Zusammenfassung Die Wasserproben wurden mit Hilfe der elektrothermischen AAS direkt sowie nach Anreicherung durch Chelatextraktion (Ammoniumtetramethylen-dithiocarbamat/Methylisobutylketon) bestimmt. Die nach beiden Methoden erhaltenen Werte stimmten gut überein. Filtrierbare Rückstände von Leitungswasser sowie Ausfällungen aus Wasserreservoirs wurden nach saurem Aufschluß mit Hilfe der Flammen-AAS analysiert.Die Ergebnisse führten zu folgenden Feststellungen: I. Zur Zeit gibt es keine von Oberflächenwasser ausgehende signifikante Verunreinigung mit Schwermetallen. II. Wegen der nicht-korrosiven Eigenschaft des Donauwassers werden keine nennenswerten Mengen von Schwermetallen aus den Rohrmaterialien herausgelöst; lediglich der Zn-Gehalt ist in einigen Stadtteilen erhöht. III. Schwermetalle werden an Rückständen adsorbiert und treten konzentriert in den Ablagerungen von Wasserreservoirs auf. IV. Vom gesundheitlichen Standpunkt ist es wünschenswert, daß der Gehalt an filtrierbaren Rückständen in Leitungswasser eine gewisse Grenze nicht überschreitet.
  相似文献   

8.
Zusammenfassung Mit dem beschriebenen Verfahren konnte eine Weiterentwicklung der alkalimetrischen Methode bei komplexometrischen Bestimmungen erzielt werden, wobei nach einer Vorneutralisation mit nur einer Titration die Bestimmung ausgeführt werden kann. Durch die einfache und exakte Indikation mit der Glaselektrode, verbunden mit einer übersichtlichen Arbeitstechnik, ergibt sich eine weitgehend universelle Anwendbarkeit des Verfahrens auf viele komplexometrische Bestimmungen. Die pH-Einstellung bei der Vorneutralisation ist unkritisch und belastet den Arbeitsgang kaum. Der Einfluß puffernder Substanzen kann durch gezielte Arbeitstechnik weitgehend unterdrückt werden. Die Methode wurde zur Bestimmung von Ca, Cd, Co, Cu, Hg(II), Mg, Mn(II), Ni, Pb und Zn angewendet. Die relative Standardabweichung liegt zwischen ±0,2 und ±0,5%.Herrn P. Sket danke ich für die sorgfältige Ausführung zahlreicher Titrationsversuche.  相似文献   

9.
Zusammenfassung Es wird ein Verfahren zur Anreicherung und Bestimmung von Spuren Ag, Cd, Co, Cu, In, Ni, Pb, Tl und Zn aus Wolframpulver beschrieben. Dazu werden die Elemente nach Lösen des Probenmaterials in H2O2 in Diäthyldithiocarbamidat-Chelate überführt. Die Chelatverbindungen werden beim Filtrieren der Lösung durch ein mit Aktivkohle beschichtetes Filter adsorbiert und an der Kohleoberfläche angereichert. Die angereicherten Elemente werden durch Röntgenfluorescenz-Spektrometrie oder nach Ablösen von der Kohle mit HNO3 durch Atomabsorptions-Spektrometrie bestimmt. Es wurden relative Standardabweichungen, je nach Element, von 0,02–0,16 ermittelt. Die Nachweisgrenze liegt bei 0,04–2,3 ppm.Wir danken dem Fonds der chemischen Industrie für die finanzielle Unterstützung dieser Arbeit.  相似文献   

10.
Summary A convenient and accurate analytical procedure has been developed for the simultaneous determination of the toxic trace metals Cd, Cu, Pb and Zn in soils. The method is based on differential pulse anodic stripping voltammetry at the hanging mercury drop electrode in the analyte resulting from the digested soil. Pressurized wet digestion of the finely powdered soil in a mixture of HNO3-HCl optionally followed by UV irradiation of the analyte to decompose dissolved organic matter, was used to prepare the analyte for the voltammetric analysis. The applicability of the method was proved by the analysis of 12 soil samples from various polluted and unpolluted regions. The accuracy was verified with the standard soil material SO-6 from JRC, Ispra, and by the parallel analysis of 8 different soil samples with the described procedure and with the relevant modes of atomic absorption spectrometry as an independent determination method.
Simultanbestimmung der toxischen Spurenmetalle Cd, Cu, Pb und Zn in Böden mit Hilfe der differentiellen Pulsinversvoltammetrie
Zusammenfassung Ein zuverlässiges und leicht durchführbares Analysenverfahren zur Simultanbestimmung der toxischen Spurenmetalle Cd, Cu, Pb und Zn in Böden wird vorgestellt. Die Bestimmungsmethode ist die differentielle Pulsinversvoltammetrie an der hängenden Quecksilbertropfenelektrode im Analyten, der aus dem Aufschluß der Bodenprobe resultiert. Die fein pulverisierte Bodenprobe wird einem Druckaufschluß mit HNO3-HCl-Gemisch unterworfen. Gegebenenfalls wird der resultierende Analyt mit UVLicht bestrahlt zur photolytischen Zersetzung noch vorhandener gelöster organischer Substanzen. Die breite Anwendbarkeit des Verfahrens wird durch die Analyse von 12 Bodenproben aus verschiedenen belasteten und unbelasteten Regionen demonstriert. Zur Richtigkeitssicherung wurden der Bodenstandard SO-6 von JRC, Ispra, untersucht und acht verschiedene Bodenproben einer Parallelbestimmung mit der differentiellen Pulsinversvoltammetrie und mit entsprechenden Moden der Atomabsorptionsspektrophotometrie unterzogen.
  相似文献   

11.
Zusammenfassung Zur Bestimmung von Sn, Pb, Cu, Cd in Zinkmetall und Zinksalzen wird die Anreicherung an einer Quecksilberfilmelektrode auf Glaskohle in salzsaurer Lösung vorgenommen. In der gleichen Lösung werden Cu und Cd durch anodische Ablösung bestimmt. Zur Trennung von Sn und Pb wird die salzsaure Lösung nach dem Anreicherungsschritt mit ammoniakalischer Citratlösung gemischt. In der resultierenden Lösung werden die Auflösungsströme für Sn und Pb gemessen. Die relativen Standardabweichungen betragen 1,3 bis 4,7%.
Determination of traces of Sn, Pb, Cu, Cd in zinc and zinc salts by anodic stripping voltammetry
The enrichment is performed in 0.8 N HCl at a glassy carbon electrode mercury plated in situ. Cu and Cd are determined by anodic stripping in the same solution. In order to separate Sn and Pb the HCl solution is mixed with a highly ammoniacal citrate solution. In the resulting medium Sn and Pb are stripping out of the electrode. Relative standard deviations are in the range of 1.3 to 4.7%.
  相似文献   

12.
Summary A correction method to diminish errors caused by different mass absorption coefficients of the samples is described. Also errors caused by differing device parameters are diminished. The method is used for the determination of Fe, Cr, Ni, Co, Mn, Zn, Cd, Cu, Hg and Pb on chemically modified silica in the g/g-range.
Anwendung einer Methode zur Matrixkorrektur durch Compton-Streupeaks für die quantitative Bestimmung von Metallen in Kieselgelen mit Hilfe der wellenlängendispersiven Röntgenfluorescenzanalyse (WDXRF)
Zusammenfassung Ein Korrekturverfahren zur Verminderung von Meßfehlern, die durch unterschiedliche Massenabsorptionskoeffizienten der Proben verursacht werden, wird beschrieben. Ebenso werden Fehler durch Schwankungen von Geräteparametern verringert. Die Methode wird benutzt zur Bestimmung von Fe, Cr, Ni, Cd, Co, Mn, Zn, Cu, Hg und Pb auf chemisch modifizierten Kieselgelen im g/g-Bereich.
  相似文献   

13.
Summary A summary is given of possible pitfalls identified in the speciation studies of trace elements by Differential Pulse Anodic Stripping Voltammetry including sampling-, storage- and sample treatment procedures.
Mögliche Mißdeutungen bei ASV-Speciesuntersuchungen von natürlichen Wässern
Zusammenfassung Die Probleme, die bei Speciesuntersuchungen von Spurenelementen mit Hilfe der Differentialpuls Anodic Stripping Voltammetrie auftreten, werden zusammenfassend dargestellt. Neben den bei der eigentlichen Bestimmung auftretenden Problemen, werden auch solche erwähnt, die mit der Probennahme sowie der Lagerung und Vorbehandlung der Proben in Zusammenhang stehen.


Dedicated to Prof. Dr. W. Fresenius on the occasion of his 70th birthday  相似文献   

14.
    
Zusammenfassung Für die Bestimmung des hochwirksamen Insecticids DDVP wurden drei voneinander unabhängige Methoden gefunden. Die erste beruht auf der jodometrischen Bestimmung des durch alkalische Spaltung gebildeten Dichloracetaldehyds. Bei der zweiten wird der durch alkalische Hydrolyse abgespaltene Phosphorsäuredimethylester acidimetrisch erfaßt. Diese beiden Arbeitsmethoden eignen sich für die Bestimmung von Makromengen DDVP, während die dritte Methode Mengen bis auf wenige Mikrogramme herunter erfaßt. Sie beruht auf der Umsetzung von DDVP in wäßriger Lösung mit Resorcin und Alkali unter Bildung eines gelben Farbstoffes mit grüner Fluorescenz, der colorimetrisch gemessen werden kann.  相似文献   

15.
    
Zusammenfassung Es wurde eine neue, gut reproduzierbare und schnell durchführbare Methode zur Bestimmung von Ascorbinsäure und ihrer Salze und Ester ausgearbeitet, bei der die Titration mit Hilfe einer kombinierten Platin-Silber/Silberchlorid-Elektrode erfolgt. Der Endpunkt der Titration kann mit sehr großer Genauigkeit bestimmt werden. Diese Methode ist ganz besonders auch bei farbigen Extrakten mit Vorteil anwendbar. Sie ist zur Automatisierung geeignet. Die relative Standardabweichung beträgt ± 0,15%.
New potentiometric assay method for ascorbic acid and its compounds
The method works fast and the reproducibility is good. A combined platinum-silver/silver chloride electrode is used and the end point can be determined with great accuracy and is especially valuable for coloured solutions. The method is suitable for automatization. Relative standard deviation is ± 0.15%.
  相似文献   

16.
Summary Low levels of copper in niobium may be determined rather rapidly and accurately by differential pulse anodic stripping voltammetry (DPASV). Three sigma detection limit of about 10 ppb can be achieved with a stripping time of 10 min. Wire, sheet and rod samples are dissolved by anodic oxidation in methanol and powder samples in a mixture of hydrofluoric acid and nitric acid. The methanolic solution is transferred into an aqueous one by the addition of an aqueous 1 M oxalic acid solution and by the evaporation of the methanol. The oxalic acid and oxalic acid + hydrofluoric acid solutions, respectively, are analysed by DPASV without any separation of the matrix. Only a few metals interfere with the copper signal when they are present in large excess, but these interferences can be overcome by changing the electrolyte, the solution or the pH. — This method can also be applied to the determination of copper in niobium salts that are soluble in oxalic acid or in hydrofluoric acid.
Bestimmung von Kupfer in Niob im Sub-ppm-Bereich durch inverse differenzielle Pulspolarographie
Zusammenfassung Niedrige Gehalte an Kupfer in Niob können ziemlich schnell und genau mit Hilfe der inversen differenziellen Pulspolarographie bestimmt werden. Mit einer Anreicherungszeit von 10 min erreicht man eine Drei-Sigma-Nachweisgrenze von ungefähr 10 ppb. Draht-, Platten- und Stangenproben werden durch anodische Oxidation in Methanol und Pulverproben in einer Mischung aus Flußsäure und Salpetersäure gelöst. Die methanolische Lösung wird durch Zugabe von 1 M Oxalsäure und durch Verdampfen des Methanols in eine wäßrige Lösung überführt. Die oxalsaure Lösung ohne bzw. mit Flußsäure wird mit Hilfe der inversen differentiellen Pulspolarographie ohne Abtrennen der Matrix analysiert. Nur wenige Metalle stören die Kupferstufe, wenn sie in großem Überschuß zugegen sind. Man kann diese Störungen u.a. durch Änderung des Elektrolyten, durch Lösungswechsel oder pH-Änderung beseitigen. — Diese Analysenmethode kann auch bei der Bestimmung von Kupfer in Niobsalzen angewandt werden, die sich in Oxalsäure oder Flußsäure lösen.
Presented in part at the International Symposium on Microchemical Techniques, Davos, Switzerland, May 22–27, 1977  相似文献   

17.
Zusammenfassung Eine gaschromatographische Methode zur Bestimmung der Zusammensetzung von Aluminiumalkylverbindungen wird beschrieben. Insbesondere eignet sie sich zur Bestimmung des Gehaltes an aktivem Material und des Verhältnisses zwischen den Mengen an Äthylgruppen, Butylgruppen und Hydridwasserstoff in Triäthylaluminium, das mit der Zweistufensynthese nach Ziegler dargestellt wurde.Die mit Cyclohexan stark verdünnten Proben werden zuerst mit Hilfe von Laurinsäure auf einem Träger in einem Zersetzungsrohr zersetzt. Darauf werden die Äthan/Butan- und Äthan/Wasserstoff-Verhältnisse in den gebildeten Gasen in gesonderten Säulen bestimmt. Im ersten Fall verwendet man Wasserstoff und Dibutylphthalat, im zweiten Argon und Silicagel als Trägergas bzw. stationäre Phase. Die absolute Menge wird durch Zusatz einer bekannten Menge n-Pentan als Vergleichssubstanz ermittelt.  相似文献   

18.
Summary A simple and specific quantitative HPLC method for the analysis of methomyl residues in fruit crops and water is described. The method is based on simple extraction steps, high-performance liquid chromatographic separation using a reversed phase column (RP-C18) and UV detection. With this analytical system, methomyl residues at 1 ng/g level can be detected. This approach allows also the simultaneous determination of methomyl and its degradation product methomyl-oxime. This is possible either by using the UV detector at 233 nm or by using both the UV- and the electrochemical detectors in series. Using this combined detection system, it was possible to determine methomyl at the 1 ng/ml level and methomyl-oxime at the 100 pg/ml level in water. Recovery rate in the range of 0.01–1 g/g is 101.4±6% in fruit crops (apples) and 93.7±4% in water.
Bestimmung von Methomyl und Methomyl-oxim in Obst und Wasser mit Hilfe der HPLC
Zusammenfassung Es wird eine hochleistungs-flüssigkeits-chromatographische Methode zur quantitativen Bestimmung der Methomylrückstände in Obst und Wasser beschrieben, mit der noch Rückstandsmengen von 1 ng/g (ppb) erfaßbar sind. Das Verfahren besteht aus einem Extraktionsschritt, Aufreinigungsschritt, der Trennung der Rückstände auf einer Umkehrphase (RP-C18) und der UV-Detektion. Die Methode ermöglicht die gleichzeitige Bestimmung von Methomyl und seinem Hydrolyseprodukt (Methomyl-oxim) durch die Anwendung des UV-Detektors allein oder durch zusätzliche elektrochemische Detektion. Durch diese Schaltanordnung wurden Konzentrationen von 1 ng/ml Methomyl und 100 pg/ml (ppt) Methomyl-oxim in Wasser bestimmt. Die Methode gestattet im Bereich von 0,01–1 g/g eine Wiederfindungsrate von 101,4±6% in Obst (Äpfel) und 93,7±4% in Wasser.
  相似文献   

19.
Summary Thorium in uranium is determined directly at trace levels by an XRF method. Uranium oxide samples are put in the form of double layer pellets and analysed by using Philips PW-1220 X-ray spectrometer. The typical value of the precision of the method at 200 ppm level is ±10% and estimation range is 50–1000 ppm of thorium in uranium.
Direkte Bestimmung von Thorium in Uranoxid durch Röntgenfluorescenz-Spektrometrie
Zusammenfassung Mit Hilfe der beschriebenen Methode kann Th in Spurenkonzentrationen direkt bestimmt werden. Die Uranoxidproben werden als Doppelschicht-Tabletten eingesetzt und mit Hilfe eines Philips PW-1220 Röntgenspektrometers analysiert. Die Genauigkeit im Bereich von 200 ppm beträgt ±10%. Der Anwendungsbereich liegt bei 50–1000 ppm.
  相似文献   

20.
Summary A method is developed for the determination of traces of Bi, Cd, Co, Cu, Fe, Mn, Pb, Te and Zn in selenium of approx. 99.99% purity. The traces are preconcentrated as chelate complexes on activated charcoal and are desorbed without destruction of the charcoal pores via competitive complexation with diethylenetriaminepentaacetic acid. The concentrate is analyzed by flame AAS-pulse aspiration. For increasing the sensitivity of the determination of Bi, Pb and Te a slotted quartz tube atom trap is attached to the burner. The atomization in the flame of metal chelates adsorbed on activated charcoal is discussed.
Mikrospurenbestimmung in hochreinem SelenI. Anreicherung der Spuren auf Aktivkohle mit nachfolgender Flammen-AAS-Bestimmung
Zusammenfassung Ein Verfahren wurde entwickelt zur Bestimmung von Spuren Bi, Cd, Co, Cu, Fe, Mn, Pb, Te und Zn in Selen vom Reinheitsgrad 99,99%. Die Elementspuren werden als Chelatkomplexe auf Aktivkohle angereichert mit nachfolgender Desorption durch Konkurrenz-Komplexbildung mit Diethylenetriamin-pentaessigsäure. Das Konzentrat wird durch Flammen-AAS (Pulstechnik) analysiert. Die Empfindlichkeit der Bestimmung von Bi, Te und Pb wird mit Hilfe einer auf dem Brenner montierten doppelt geschlitzten Quarzröhre erhöht. Die Atomisierung von auf Aktivkohle adsorbierten Metallchelaten in der Flamme wird diskutiert.
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏