首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
Fusarium species, a plant pathogenic fungus of wheat and other cereals, produces toxic metabolites such as nivalenol (NIV) and deoxynivalenol (DON). Control of contamination by these toxins is very difficult, and a continuous survey of the occurrence is necessary for these toxins. Thus, the accurate and convenient determination of the cereals contaminated with these toxins is important for the supply of safe foods. A selective analytical method based on high‐performance liquid chromatography, combined with atmospheric pressure photoionization (APPI) mass spectrometry, has been developed for simultaneous determination of NIV and DON. The parameters investigated for the optimization of APPI were the ion source parameters fragmentor voltage, capillary voltage, and vaporizer temperature, and also mobile phase composition and flow rate. Furthermore, chemical noise and signal suppression of analyte signals due to sample matrix interference were investigated for APPI. The results indicated that APPI provides lower matrix effect and the correlation coefficient of NIV and DON in the range 0.2–100 ng · mL?1 was above 0.999. Recoveries of NIV and DON in wheat ranged from 86 to 107% and limits of detection of NIV and DON were 0.20 ng · g?1 and 0.39 ng · g?1, respectively. In addition, the proposed method was applied for the analysis of naturally contaminated wheat samples. APPI was found to offer lower matrix effect and was a convenient technique for routine analysis of NIV and DON residues in wheat at trace levels. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
Liquid chromatography/atmospheric pressure photoionization tandem mass spectrometry (LC/APPI-MS/MS) was investigated as an instrumental method for the analysis of the halogenated norbornene flame retardants, Mirex, Dechloranes 602, 603, 604, and Dechlorane Plus (DP). The LC separation was optimized by screening a variety of stationary and mobile phases, resulting in a short LC separation time of 5 min. Different atmospheric pressure ionization approaches were examined including electrospray ionization, atmospheric pressure chemical ionization, and APPI, each with and without post-column addition. APPI without post-column addition was chosen for providing the best ionization response. The optimized LC/APPI-MS/MS approach resulted in instrument detection limits ranging between 25 and 50 pg. Good linearity was also achieved (up to 25.0 ng/μL; R >0.999). The method was applied to extracts of environmental samples including surface water, fish and sediments for screening purposes, and the results agreed well with those obtained by gas chromatography/mass spectrometry.  相似文献   

4.
CZE is an appropriate technique for separating charged species, but lacks selectivity for neutral compounds. Alternative approaches such as microemulsion electrokinetic chromatography (MEEKC) have been developed to broaden its range of applications. Hyphenation of MEEKC with MS is an attractive perspective since it can enhance sensitivity and selectivity. The on-line coupling of MEEKC with MS, however, is not straightforward due to the low compatibility of non-volatile surfactant additives (e.g. SDS) and the commonly used API source, namely ESI. In order to hyphenate MEEKC with MS detection, the atmospheric pressure photoionization (APPI) source was investigated. Possibilities offered by the coupling of MEEKC with APPI-MS were highlighted for the complex separation of ionized and neutral compounds in both the positive and negative modes. MEEKC-APPI-MS performance, in terms of selectivity, efficiency and sensitivity was compared to CZE-ESI-MS and MEEKC-ESI-MS for the screening of doping substances (beta-blockers, central stimulants, diuretics, etc). Relevant selectivity and detectability, particularly for neutral, structurally related and isobaric compounds was demonstrated with the MEEKC-APPI-MS approach opening new avenues for CE-MS, in addition to the well-established CZE-ESI-MS technique.  相似文献   

5.
A methodology has been developed and validated for quantifying 8-hydroxydeoxyguanosine (8-OHdG) in both commercial DNA and DNA isolated from livers of male Sprague-Dawley rats by liquid chromatography/positive atmospheric pressure photoionization tandem mass spectrometry. The analytical method conditions, including conditions for stabilizing 8-OHdG during complex nuclease P1 enzymatic digestion, were also evaluated. The limit of detection for 8-OHdG was 1.0 ng/mL (17.6 fmol on-column), and the linearity of the calibration curve was greater than 0.998 from 1.0 to 500 ng/mL. The intraday assay precision relative standard deviation (RSD) value for quality control (QC) samples was < or =5.59% with accuracies ranging from 91.84 to 117.61%. The interday assay precision (RSD) value was < or =1.76% with accuracies ranging from 91.84 to 116.67%. This method, combined with the LC/UV analysis of deoxyguanosine (dG), was used for determination of the levels of 8-OHdG/10(6) dG in DNA nuclease P1 enzymatic hydrolysates from both commercial DNA and rat liver DNA.  相似文献   

6.
Gas chromatography (GC) and ion trap mass spectrometry (MS) were combined with microchip atmospheric pressure chemical ionization (microAPCI) and microchip atmospheric pressure photoionization (microAPPI) sources. Selected polychlorinated biphenyls (PCBs, IUPAC Nos. 28, 52, 101, 118, 138, 153 and 180) were analyzed by GC/microAPCI-MS and GC/microAPPI-MS to demonstrate the applicability of the miniaturized ion sources in negative ion mode analysis. The microAPCI and microAPPI methods were evaluated in respect of detection limit, linearity and repeatability. The detection limits for the PCB congeners were somewhat lower with microAPCI than with microAPPI, whereas microAPPI showed slightly wider linear range and better repeatability. With both methods, the best results were obtained for highly chlorinated or non-ortho-chlorinated PCBs, which possess the highest electron affinities. Finally, the suitability of the GC/microAPPI-MS method for the analysis of PCBs in environmental samples was demonstrated by analyzing soil extracts, and by comparing the results with those obtained by gas chromatography with electron capture detection (GC/ECD).  相似文献   

7.
Analysis of several polar and non-polar compounds is performed with a newly developed dual electrospray ionization/atmospheric pressure photoionization (ESI/APPI) or ESPI source. Several variables are considered in the source, such as ESI probe heater temperature, solvent flow, dopant effects, repeller plate voltage, source geometry and photon energy (Kr vs. Ar lamp). Direct photoionization resulting in a molecular radical cation [M](*+) dominates at high temperatures (>400 degrees C) and low flow rates (<200 microL/min). Indirect photo-induced chemical ionization (PCI) involving solvent molecules becomes important at lower temperatures and higher solvent flow rates. Indirect PCI is enhanced using an Ar lamp, which yields comparable [M+H](+) signal but poorer [M](*+) signal than the Kr lamp at lower temperatures and higher flow rates. This is in support of our recent finding that the Ar lamp results in a solvent-dependent enhancement of analyte molecules via PCI. Analysis of 12 compounds in methanol under low-flow conditions (10 microL/min) demonstrates that the dual ESPI source performs favorably for most compounds versus the standard ESCI source, and significantly better than ESCI for the analysis of unstable drugs, like flurbiprofen. Several factors contributing to the benefits of the ESPI source are the shared optimal geometry for ESI and APPI sources and soft ionization of APPI versus APCI.  相似文献   

8.
9.
We examined the feasibility of capillary liquid chromatography/microchip atmospheric pressure photoionization tandem mass spectrometry (capLC/µAPPI‐MS/MS) for the analysis of anabolic steroids in human urine. The urine samples were pretreated by enzymatic hydrolysis (with β‐glucuronidase from Helix pomatia), and the compounds were liquid‐liquid extracted with diethyl ether. After separation the compounds were vaporized by microchip APPI, photoionized by a 10 eV krypton discharge lamp, and detected by selected reaction monitoring. The capLC/µAPPI‐MS/MS method showed good sensitivity with detection limits at the level of 1.0 ng mL?1, good linearity with correlation coefficients between 0.9954 and 0.9990, and good repeatability with relative standard deviations below 10%. These results demonstrate that microchip APPI combined with capLC/MS/MS provides a new potential method for analyzing non‐polar and neutral compounds in biological samples. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

10.
11.
12.
We introduce a novel electropneumatic‐heated nebulizer (EPn‐HN), incorporating an electrified internal pneumatic nebulizer, to enhance the yield of sprayed ions from PhotoSpray? atmospheric pressure photoionization (APPI) sources for liquid chromatography/mass spectrometry (LC/MS). Spray ionization from the pneumatic‐heated nebulizers used in APPI sources provides a supplemental, complementary ionization method to be used for involatile and thermally labile compounds, otherwise intractable to APPI. Details of the construction and operation of the EPn‐HN device are provided. The performance of the EPn‐HN is demonstrated using two model compounds: substance P, a peptide used as a standard in studies of ion fragmentation mechanisms, and aztreonam, a thermally labile antibiotic. At the optimum voltage for spray ionization, improvements in sensitivity of two orders of magnitude are obtained relative to when the sprayer is grounded, the conventional case. Since both substance P and aztreonam cannot be detected using the APPI method alone, the results demonstrate how spray ionization from the EPn‐HN may be used to extend the range of compounds amenable to PhotoSpray sources. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

13.
14.
The study of several structural variations (the length, the degree of unsaturation and hydroxylation of the alkyl chains, the number and nature of osidic residues) helped understand the behaviour of neutral glycosphingolipids (GSLs) on porous graphitic carbon stationary phase (PGC). Atmospheric pressure photoionization mass spectrometry (APPI) and tandem mass spectrometry were used to perform the detection and the identification of molecular species in positive mode where [M+H](+) and [M-H(2)O+H](+) ions provided structural information on the fatty acid and the sphingoid base. The retention of GSLs increased with the hydrocarboneous volume of their alkyl chains and with the number of osidic residues in agreement with hydrophobic properties and polar retention effect of graphite, respectively. The presence of polar groups, such as OH-group or double bond within alkyl chains, decreased their retention. The coupling of chromatography on PGC with APPI tandem mass spectrometry detection appeared a powerful technique to discriminate isobaric molecules. Isobaric solutes differing by the position of two double bonds or by the repartition of hydrocarboneous skeleton were discriminated according to their chromatographic comportment or their mass spectrum, respectively. Among isobaric molecules, only few structures differing by the nature of osidic residue were not discriminated (i.e. glucosylceramide and galactosylceramide with similar ceramide skeleton were co-eluted and no difference in mass spectra was observed).  相似文献   

15.
16.
17.
The composition of the dopant for the analysis of polycyclic aromatic hydrocarbons (PAHs) by liquid chromatography/dopant-assisted atmospheric-pressure photoionization/mass spectrometry under reversed-phase conditions was optimized to enhance the ionization efficiency for PAHs. The most suitable dopant was a toluene/anisole mixture (99.5:0.5, v/v) and it could improve limit of detections (LODs) to 0.79-168 ng mL(-1) (signal-to-noise (S/N)=3) for 16 common PAHs. The LODs are 3.8-40 times lower than those obtained with toluene alone and are comparable to those obtained using gas chromatography/mass spectrometry.  相似文献   

18.
A simple, fast and sensitive liquid chromatography/atmospheric pressure photoionization mass spectrometry (LC/APPI-MS) method, with automated on-line extraction using turbulent flow chromatography (TFC), was developed for the determination of perfluorooctane sulfonate (PFOS) in river water. In this method, following an on-line extraction by injection onto a column under TFC conditions, PFOS is back-flushed onto a reversed-phase column via on-line column switching, and resolved chromatographically at a laminar flow rate of 1 mL min(-1). Using this tandem LC-LC/APPI-MS system the extraction, separation and selective detection of PFOS in river water could be achieved with satisfactory selectivity and sensitivity. The limit of detection (LOD) (S/N = 3) and the limit of quantitation (LOQ) (S/N = 10)were 5.35 and 17.86 pg mL(-1). The described procedure was very simple since no off-line sample preparation was required, total analysis time being 18.75 min.  相似文献   

19.
An analytical method is presented for the determination of chlorantraniliprole residues in crops. Chlorantraniliprole residues were extracted from crop matrixes with acetonitrile after a water soak. The extracts were passed through a strong anion-exchange (SAX) SPE cartridge stacked on top of a reversed-phase (RP) polymer cartridge. After both cartridges were rinsed and vacuum-dried, the SAX cartridge was removed, and chlorantraniliprole was eluted from the RP polymer cartridge with acetonitrile. The acetonitrile eluate was evaporated to dryness, reconstituted, and analyzed using an LC/MS/MS instrument equipped with an atmospheric pressure chemical ionization source. The method was successfully validated at 0.010, 0.10, and 10 mg/kg for the following crop matrixes: potatoes, sugar beets (tops), lettuce, broccoli, soybeans, soybean forage, tomatoes, cucumbers, oranges, apples, pears, peaches, almonds (nutmeat), rice grain, wheat grain, wheat hay, corn stover, alfalfa forage, cottonseed, grapes, and corn grain. The average recoveries from all crop samples fortified at the method LOQ ranged from 91 to 108%, with an overall average recovery of 97%. The average recoveries from all crop samples fortified at 10 times the method LOQ ranged from 89 to 115%, with an overall average recovery of 101%. For all of the fortified control samples analyzed in this study, the overall average recovery was 99%.  相似文献   

20.
This study compared the sensitivities and matrix effects of four ionization modes and four reversed-phase liquid chromatographic (LC) systems on analyzing estrone (E1), 17β-estradiol (E2), estriol (E3), 17α-ethinylestradiol (EE2), 4-nonylphenol (NP), 4-tert-octylphenol (OP), bisphenol A (BPA) and their derivatives of dansyl chloride or pentafluorobenzyl bromide (PFBBr) in water matrixes using a triple-quadrupole mass spectrometer with selected reaction monitoring (SRM). The four probes were electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI), atmospheric pressure photoionization (APPI) and APCI/APPI; the four LC systems were ultra-performance liquid chromatography (UPLC) with or without post-column split, a mixed-mode column and two-dimensional LC (2D-LC). Dansylated compounds with ESI at UPLC condition had the most intense signals and less matrix effects of the various combinations of ionization and LC systems. The on-column limits of detection (LODs) of dansylated estrogens by SRM were 0.05–0.20 pg, and the LODs in sewage treatment plant effluent and in river water were 0.23–0.52 and 0.56–0.91 ng/L, respectively. The LODs using selected ion monitoring (SIM) reached low ng/L levels in real samples and measured concentrations were comparable with those of SRM.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号