首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
3.
Presented is the first comprehensive study of drugs of abuse on suspended particulate matter (SPM) in wastewater. Analysis of SPM is crucial to prevent the under-reporting of the levels of analyte that may be present in wastewater. Analytical methods to date analyse the aqueous part of wastewater samples only, removing SPM through the use of filtration or centrifugation. The development of an analytical method to determine 60 compounds on SPM using a combination of pressurised liquid extraction, solid phase extraction and liquid chromatography coupled with tandem mass spectrometry (PLE-SPE-LC-MS/MS) is reported. The range of compounds monitored included stimulants, opioid and morphine derivatives, benzodiazepines, antidepressants, dissociative anaesthetics, drug precursors, and their metabolites. The method was successfully validated (parameters studied: linearity and range, recovery, accuracy, reproducibility, repeatability, matrix effects, and limits of detection and quantification). The developed methodology was applied to SPM samples collected at three wastewater treatment plants in the UK. The average proportion of analyte on SPM as opposed to in the aqueous phase was <5% for several compounds including cocaine, benzoylecgonine, MDMA, and ketamine; whereas the proportion was >10% with regard to methadone, EDDP, EMDP, BZP, fentanyl, nortramadol, norpropoxyphene, sildenafil and all antidepressants (dosulepin, amitriptyline, nortriptyline, fluoxetine and norfluoxetine). Consequently, the lack of SPM analysis in wastewater sampling protocol could lead to the under-reporting of the measured concentration of some compounds.  相似文献   

4.
This is the first study presenting a multi-residue method allowing for comprehensive analysis of several chiral pharmacologically active compounds (cPACs) including beta-blockers, antidepressants and amphetamines in wastewater and digested sludge at the enantiomeric level. Analysis of both the liquid and solid matrices within wastewater treatment is crucial to being able to carry out mass balance within these systems. The method developed comprises filtration, microwave assisted extraction and solid phase extraction followed by chiral liquid chromatography coupled with tandem mass spectrometry to analyse the enantiomers of 18 compounds within all three matrices. The method was successfully validated for 10 compounds within all three matrices (amphetamine, methamphetamine, MDMA, MDA, venlafaxine, desmethylvenlafaxine, citalopram, metoprolol, propranolol and sotalol), 7 compounds validated for the liquid matrices only (mirtazapine, salbutamol, fluoxetine, desmethylcitalopram, atenolol, ephedrine and pseudoephedrine) and 1 compound (alprenolol) passing the criteria for solid samples only. The method was then applied to wastewater samples; cPACs were found at concentration ranges in liquid matrices of: 1.7 ng L−1 (metoprolol) – 1321 ng L−1 (tramadol) in influent, <LOD (desmethylcitalopram and metoprolol) – 506 ng L−1 in effluent, and in solid matrix digested sludge: 0.4 ng g−1 (metoprolol) – 275 ng g−1 (citalopram). Enantiomeric profiling revealed that studied compounds were present in analysed samples in non-racemic composition. Furthermore, enantiomeric composition of studied analytes differed in liquid and solid matrices. This demonstrates that not analysing the solid fraction of wastewater may lead to over-estimation of the removal rates of cPACs as well as possible misrepresentation of the enantiomeric fraction of the compounds as they leave the wastewater treatment plant. Consequently risks from cPACs entering the environment might be higher than anticipated.  相似文献   

5.
The paper presents the development and validation of a new multi-residue method for the determination of 28 basic/neutral pharmaceuticals (antiepileptics, antibacterial drugs, beta-blockers, analgesics, lipid-regulating agents, bronchodilators, histamine-2-blockers, anti-inflammatory agents, calcium channel blockers, angiotensin-II antagonists and antidepressants) and illicit drugs in surface water with the usage of a new technique: ultra performance liquid chromatography-positive electrospray tandem mass spectrometry (UPLC-MS/MS). The usage of the novel UPLC system with 1.7 microm particle size and 1mm internal diameter column allowed for low mobile phase flow rates (0.07 mL min(-1)) and short retention times (from 1.3 to 15.5 min) for all compounds analysed. As a result, a fast and cost-effective method was developed. SPE with the usage of Oasis MCX strong cation-exchange mixed-mode polymeric sorbent was chosen for pharmaceuticals extraction from environmental samples. The influence of matrix-assisted ion suppression and low SPE recovery on the sensitivity of the method was studied. The instrumental limits of quantification varied from 0.2 to 10 microg L(-1). The method limits of quantification were at low nanogram per litre levels and ranged from 0.3 to 50 ng L(-1). The instrumental and method intra- and inter-day repeatabilities were on average less than 10%. The method was applied for the determination of pharmaceuticals in Rivers Taff (UK) and Warta (Poland). Fifteen compounds were determined in river water at levels ranging from single nanograms to single micrograms per litre.  相似文献   

6.
A sensitive rapid resolution liquid chromatography-tandem mass spectrometry (RRLC-MS/MS) method, combined with solid-phase extraction, ultrasonic extraction and silica gel cartridge cleanup, was developed for 28 steroids including 4 estrogens (estrone (E1), 17β-estradiol (E2), 17α-ethynyl estradiol (EE2), diethylstilbestrol (DES)), 14 androgens (androsta-1,4-diene-3,17-dione (ADD), 17α-trenbolone, 17β-trenbolone, 4-androstene-3,17-dione, 19-nortestoserone, 17β-boldenone, 17α-boldenone, testosterone (T), epi-androsterone (EADR), methyltestosterone (MT), 4-hydroxy-androst-4-ene-17-dione (4-OHA), 5α-dihydrotestosterone (5α-DHT), androsterone (ADR), stanozolol (S)), 5 progestagens (progesterone (P), ethynyl testosterone (ET), 19-norethindrone, norgestrel, medroxyprogesterone (MP)), and 5 glucocorticoids (cortisol, cortisone, prednisone, prednisolone, dexamethasone) in surface water, wastewater and sludge samples. The recoveries of surface water, influents, effluents and sludge samples were 90.6-119.0% (except 5α-DHT was 143%), 44.0-200%, 60.7-123% and 62.6-138%, respectively. The method detection limits for the 28 analytes in surface water, influents, effluents and freeze-dried sludge samples were 0.01-0.24 ng/L, 0.02-1.44 ng/L, 0.01-0.49 ng/L and 0.08-2.06 ng/g, respectively. This method was applied in the determination of the residual steroidal hormones in two surface water of Danshui River, 12 wastewater and 8 sludge samples from two wastewater treatment plants (Meihu and Huiyang WWTPs) in Guangdong (China). Ten analytes were detected in surface water samples with concentrations ranging between 0.4 ng/L (17β-boldenone) and 55.3 ng/L (5α-DHT); twenty analytes in the wastewater samples with concentrations ranging between 0.3 ng/L (P) and 621 ng/L (5α-DHT); and 12 analytes in the sludge samples with concentrations ranging between 1.6 ng/g (E1) and 372 ng/g (EADR).  相似文献   

7.
This paper describes the development and validation of a method for the simultaneous determination of 53 multi-class emerging organic pollutants in water samples using solid-phase extraction (SPE) followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS), using electrospray ionisation (ESI) in both positive and negative modes. Target compounds include acidic herbicides, UV filters, insect repellents, organophosphorous flame retardants, a bactericide, pharmaceuticals and metabolites. A single SPE consisting on the loading of 200-500 mL of sample adjusted to pH 7 on Oasis HLB 200mg cartridges and elution with methanol, permitted obtaining good recoveries: higher than 60% for tap, surface and wastewater in most cases. The 7 isotopically labelled internal standards effectively compensated losses during sample preparation and matrix effects at LC-MS/MS determination. The precision of the method, calculated as relative standard deviation (RSD) was below 15% for all compounds and all tested matrices. Detection limits (LODs) based on the confirmation, less intense, MRM (multiple reaction monitoring) transition and considering blanks varied between 0.3 and 30 ngL(-1). Finally, the developed method was applied to the determination of target analytes in various samples, including tap, surface and waste water. Among the tested emerging pollutants, 31 were found in wastewater in concentrations reaching up to 10 microgL(-1) in the case of ibuprofen. Also, 13 species were detected in tap water with concentrations up to 0.13 microgL(-1) for tri(chloropropyl) phosphate (TCPP).  相似文献   

8.
Drugs deposited in human teeth are well preserved; the spectrum of toxicological investigations may therefore be supplemented by an analysis method for drugs in teeth. A liquid chromatography–electrospray ionization tandem mass spectrometry assay for the detection and quantification of basic drugs of abuse in bovine dentin samples was developed and validated. The drugs and metabolites amphetamine, methamphetamine, methylenedioxymethylamphetamine, methylenedioxyethylamphetamine, codeine, morphine, cocaine and benzoylecgonine were extracted from 50 mg ground dentin powder by ultrasonication for 60 min in methanol 3 times. The extracts were analyzed on a triple‐quadrupole mass‐spectrometer in multiple reaction monitoring mode. The method was validated and proved to be accurate, precise, selective, specific and stable with good linearity within the calibration range and a lower limit of quantification of 10 to 20 pg/mg. To artificially load bovine dentin samples with drugs, the natural process of de‐ and remineralization in the oral cavity was mimicked by a pH‐cycling experiment. The artificially drug‐loaded dentin samples showed drug concentrations of 20 to 80 pg/mg. The method can be applied in further in vitro experiments as well as in post‐mortem cases, especially where limited sample tissue is available. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

9.
朱峰  姚志建  霍宗利  吉文亮  刘华良  周庆  李爱民  焦伟  谷静 《色谱》2020,38(12):1465-1471
近年来,环境水体中出现的药物及个人护理品污染物受到人们越来越多的关注,其中就包括解热镇痛类药物。传统的固相萃取材料对水体中解热镇痛类药物的富集效率较低。为此,开发了一种亲水亲脂型的双亲多孔吸附聚合物材料(Guochuang hydrophilic material, GCHM)。以N-乙烯基吡咯烷酮和二乙烯基苯为原料,利用乳液胶束-分步反应法成功制备出GCHM。基于自主研发的固相萃取柱,采用超高效液相色谱-串联质谱技术,建立了水体中4种解热镇痛类药物的检测方法。水样经GCHM固相萃取柱富集净化后上机检测,以0.1%(v/v)甲酸水溶液和乙腈作为流动相进行梯度洗脱,目标分析物在ACQUITY UPLC■ HSS T3色谱柱(100 mm×2.1 mm, 1.8μm)上实现分离,在电喷雾正离子模式下进行多反应监测(MRM),内标法定量。比较Oasis HLB、Bond Elut Plexa和GCHM 3种固相萃取柱的富集效率,结果表明GCHM固相萃取柱总体效果最优。在不同pH值下比较了GCHM固相萃取柱对目标分析物的富集效果,并对基质效应进行了评估。结果表明,当pH为7时,4种目标分析物在...  相似文献   

10.
An analytical method was developed to quantitatively determine pharmaceuticals in biosolid (treated sewage sludge) from wastewater treatment plants (WWTPs). The collected biosolid samples were initially freeze dried, and grounded to obtain relatively homogenized powders. Pharmaceuticals were extracted using accelerated solvent extraction (ASE) under the optimized conditions. The optimal operation parameters, including extraction solvent, temperature, pressure, extraction time and cycles, were identified to be acetonitrile/water mixture (v/v 7:3) as extraction solvent with 3 extraction cycles (15 min for each cycle) at 100 °C and 100 bars. The extracts were cleaned up using solid-phase extraction followed by determination by liquid chromatography coupled with tandem mass spectrometry. For the 15 target pharmaceuticals commonly found in the environment, the overall method recoveries ranged from 49% to 68% for tetracyclines, 64% to 95% for sulfonamides, and 77% to 88% for other pharmaceuticals (i.e. acetaminophen, caffeine, carbamazepine, erythromycin, lincomycin and tylosin). The developed method was successfully validated and applied to the biosolid samples collected from WWTPs located in six cities in Michigan. Among the 15 target pharmaceuticals, 14 pharmaceuticals were detected in the collected biosolid samples. The average concentrations ranged from 2.6 μg/kg for lincomycin to 743.6 μg/kg for oxytetracycline. These results indicated that pharmaceuticals could survive wastewater treatment processes, and accumulate in sewage sludge and biosolids. Subsequent land application of the contaminated biosolids could lead to the dissemination of pharmaceuticals in soil and water environment, which poses potential threats to at-risk populations in the receiving ecosystems.  相似文献   

11.
A method was developed to determine 11 pharmaceutical compounds in water samples. The method uses SPE and HPLC coupled to MS (LC/MS) using ESI in both positive and negative modes. Three different sorbents were compared for the extraction of analytes from river and sewage treatment plant (STP) waters and OASIS HLB provided the best results. For the solid-phase extraction of 500 mL of river water samples, the recoveries were between 41 and 101% with the exception of acetaminophen, salicylic acid and naproxen. The LODs were between 3 and 5 ng/L for all the compounds, except naproxen which had an LOD of 15 ng/L. Acetaminophen, caffeine, carbamazepine, bezafibrate and ibuprofen were found in three of the tested river samples at ng/L levels and among them, the highest values were for caffeine and bezafibrate with 305 and 363 ng/L, respectively. For the influent and effluent water samples of the STP, volumes of 100 and 250 mL were used, respectively, to obtain acceptable recoveries. All the compounds showed recoveries between 33 and 91% for effluent samples and 33-72% for influent samples, with the exception of acetaminophen, salicylic acid and bezafibrate, which had lower recoveries. The method developed enabled pharmaceuticals in the influent and effluent sewage waters to be determined in five campaigns carried out between February 2004 and June 2005. Several pharmaceuticals were found in the influent samples: for instance, maximum concentrations of ibuprofen and caffeine were 6 and 40 microg/L, respectively.  相似文献   

12.
张明  唐访良  俞雅雲  陈峰  徐建芬  叶永根 《色谱》2014,32(5):472-476
建立了固相萃取-超高效液相色谱-电喷雾串联三重四极杆质谱联用技术分析水中16种全氟有机化合物的高通量检测方法。样品经WAX固相萃取柱富集和净化后,采用Waters ACQUITY UPLCTM BEH C18色谱柱,含2 mmol/L乙酸铵的甲醇和含2 mmol/L乙酸铵的水作为流动相进行梯度洗脱,质谱采用电喷雾负离子电离,多反应监测模式检测。16种全氟有机化合物在0.5~100 μg/L或1.0~100 μg/L浓度范围内线性关系良好,相关系数为0.9987~0.9999,方法的检出限为0.06~0.46 ng/L;高、中、低3个添加水平的回收率为67.6%~103%,相对标准偏差为2.94%~12.0%。结果表明,该方法灵敏、准确且检测范围广,分析速度快,是一种适于实际水样中全氟有机化合物检测分析的方法。  相似文献   

13.
A simple and sensitive method for simultaneous analysis of 43 pharmaceutical compounds in sewage sludge and sediment samples was developed and validated. The target compounds were extracted using pressurized liquid extraction (PLE) and then purified and pre-concentrated by solid phase extraction (SPE) using a hydrophilic-lipophilic balanced polymer. PLE extraction was performed on temperature of 100 °C, with methanol/water mixture (1/2, v/v) as extraction solvent. The quantitative analysis was performed by liquid chromatography tandem mass spectrometry using a hybrid triple quadrupole-linear ion trap mass spectrometer (LC-QqLIT-MS). Data acquisition was carried out in selected reaction monitoring (SRM) mode, monitoring two SRM transitions to ensure an accurate identification of target compounds in the samples. Additional identification and confirmation of target compounds were performed using the Information Dependent Acquisition (IDA) function. The method was validated through the estimation of the linearity, sensitivity, repeatability, reproducibility and matrix effects. The internal standard approach was used for quantification because it efficiently corrected matrix effects. Despite the strong matrix interferences, the recoveries were generally higher of 50% in both matrixes and the detection and quantification limits were very low. Beside the very good sensitivity provided by LC-QqLIT-MS, an important characteristic of the method is that all the target compounds can be simultaneously extracted, treated and analysed. Hence, it can be used for routine analysis of pharmaceuticals providing large amount of data. The method was applied for the analysis of pharmaceuticals in river sediment and wastewater sludge from three treatment plants with different treatment properties (i.e. capacity, secondary treatment, quality of influent waters). The analysis showed a widespread occurrence of pharmaceuticals in the sludge matrices.  相似文献   

14.
Ye S  Yao Z  Na G  Wang J  Ma D 《Journal of separation science》2007,30(15):2360-2369
This paper describes a rapid method for the determination of 14 kinds of sulfonamides (SAs) in wastewater using SPE, and LC-MS/MS with positive ESI (ESI(+)) and selected reaction monitoring (SRM) mode. The SPE was performed on an Oasis hydrophilic-lipophilic-balanced (HLB) cartridge. Chromatographic separation on a C18 column was achieved using a binary eluent containing methanol and water with 0.2% formic acid. Typical recoveries of the analytes ranged from 22.3 to 87.0% at a fortification level of 100 ng/L. The LODs in wastewater except sulfathiazole (3 ng/L) could be detected and quantified at levels as low as 1 ng/L. Finally, the method was applied to water from the municipal outlet and the aquaculture wastewater effluent. Sulfamethazine (SM(2)), sulfamethoxypyridazine (SMP), and sulfamethoxazole (SMZ) were most frequently found in wastewater in a concentration range between 1.2 and 31.7 ng/L.  相似文献   

15.
刘正才  杨方  余孔捷  林永辉  刘素珍  张琼  苏芝娇 《色谱》2012,30(12):1253-1259
建立了鸡组织中抗病毒类药物多残留检测的液相色谱-电喷雾串联质谱法(LC-ESI-MS/MS)。采用三氯乙酸-乙腈溶液提取鸡组织中的金刚烷胺、金刚乙胺、美金刚、咪喹莫特和吗啉胍,离心过滤后经强阳离子交换柱(SCX)净化,色谱柱Xamide(100 mm×2.1 mm, 5 μm)分离,多反应监测(MRM)正离子扫描方式进行质谱检测。结果表明,鸡组织与鸡肝中5种药物的检出限为0.06~0.30 μg/kg,定量限为0.2~1.0 μg/kg。当5种药物的添加水平为0.2~10.0 μg/kg时,在鸡肉中的平均回收率为72.3%~94.2%,相对标准偏差(RSD)(n=6)为3.5%~11.3%;在鸡肝中的平均回收率为70.8%~92.7%, RSD(n=6)为5.3%~12.6%。该方法选择性好,抗干扰能力强,可作为鸡肉和鸡肝中抗病毒药物残留检测的确证方法。  相似文献   

16.
A fast and sensitive ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed for the determination of lovastatin in human plasma. With simvastatin as internal standard, sample pretreatment involved one-step extraction with n-hexane-methylene dichloride-isopropanol (20:10:1, v/v/v) of 0.5 mL plasma. Chromatographic separation was carried out on an Acquity UPLC BEH C(18) column with mobile phase consisting of acetonitrile-water (containing 5 mmol/L ammonium acetate; 85:15, v/v) at a flow-rate of 0.35 mL/min. The detection was performed on a triple-quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) via electrospray ionization source with positive mode. The analysis time was shorter than 1.7 min per sample. The standard curve was linear (r2>or=0.99) over the concentration range 0.025-50.0 ng/mL with a lower limit of quantification of 0.025 ng/mL. The intra- and inter-day precision values were below 11% and the accuracy (relative error) was within 6.0% at three quality control levels. This is the first method of MS with MRM coupled to UPLC for the determination of lovastatin, which showed great advantages of high sensitivity, selectivity and high sample throughput. It was fully validated and successfully applied to the pharmacokinetic study of lovastatin tablets in healthy Chinese male volunteers after oral administration.  相似文献   

17.
王硕  张向明  张晶  邵兵  李书明 《色谱》2015,33(7):730-739
建立了超高效液相色谱-电喷雾串联质谱(UPLC-ESI MS/MS)分析生活饮用水中54种药物的方法。采用HLB固相萃取柱对水样中的目标化合物进行富集净化,以5 mL甲醇洗脱;洗脱液用氮气吹至近干,用0.4 mL 0.1%甲酸水溶液定容,上机分析;ACQUITY UPLCTMBEH C18柱用作色谱分离,以0.1%甲酸水溶液-甲醇为流动相进行梯度洗脱;多反应监测(MRM)模式进行检测;目标药物使用基质外标法定量。54种药物在自备井水、市政末梢水和地表水中的加标回收率分别为58.7%~104.4%、53.1%~109.5%和50.7%~118.8%,相对标准偏差(n=6)分别为0.3%~12.8%、1.0%~15.5%和0.4%~19.3%;方法定量限为0.002~5.000 ng/L。将建立的方法应用于北京部分自备井水、市政末梢水和地表水样品的分析,结果在自备井水样中检出26种药物。  相似文献   

18.
In environmental analyses there is an ever-increasing need to develop simple and sensitive multi-residue methods. In many agricultural regions, there is particular concern of the potential for pesticides to enter rivers and other waterways. This study reports on the development and validation of a multi-residue method of analysis for 30 pesticides in water samples using solid-phase extraction (SPE) followed by LC-MS/MS. The electrospray and MS/MS parameters were optimised for each pesticide, including capillary voltage, collision-induced dissociation voltage, and selection of a precursor ion and two product ions. A variety of SPE sorbents were tested for sample pre-concentration, including numerous polymeric based phases. Bond Elut PPL and Oasis HLB were the only phases capable of retaining the majority of the target analyte classes in a single method. An off-line pre-concentration method using a Gilson Aspec system was optimised using the Bond Elut PPL cartridges, with a concentration factor of 25 producing limits of quantitation in the order of 6–100 ng/L. Excellent linearity (r 2 > 0.9), precision (<20%) and recovery (>60%) was obtained for nearly all of the analytes, covering a wide variety of chemical and physical properties. This is the first study to fully validate Bond Elut PPL cartridges for use in multi-residue pesticide analysis.  相似文献   

19.
Zhang M  Tang F  Chen F  Xu J  Zhang L 《色谱》2012,30(1):51-55
建立了固相萃取-超高效液相色谱-电喷雾串联三重四极杆质谱(SPE-UPLC-ESI-MS/MS)联用技术分析水中9种微囊藻毒素的方法。样品经SPE提取和净化后,以Waters ACQUITY UPLCTM BEH C18色谱柱为分离柱,以含0.1%甲酸乙腈和含0.1%甲酸水作为流动相进行梯度洗脱,电喷雾离子源电离、正离子多反应监测模式质谱进行定性和定量分析。9种微囊藻毒素在0.1~50 μg/L或0.5~100 μg/L质量浓度范围内线性良好,相关系数为0.9990~0.9998,方法的检出限(以3倍信噪比计)为0.1~0.5 ng/L;高、中、低3个添加水平的回收率为75.8%~109%,相对标准偏差为0.49%~10.0%。结果表明,该方法灵敏、准确,检测范围广,分析速度快。应用该方法检测了杭州市两处水库水样中的微囊藻毒素,分别检出了3种和8种微囊藻毒素。  相似文献   

20.
建立了分散固相萃取-高效液相色谱-串联质谱(dispersive-SPE-HPLC-MS/MS)同时测定畜禽肉中 β-内酰胺类、喹诺酮类、磺胺类、磺胺类增效剂和抗寄生虫类共5类63种兽药残留的新方法。样品经0.1 mol/L Na2EDTA溶液及含1% (体积分数)乙酸的乙腈溶液涡旋提取,提取液经C18分散固相萃取净化后,用Poroshell EC-C18色谱柱(100 mm×2.1 mm, 2.4 μm)分离,在电喷雾离子源正离子模式下以动态多反应监测(DMRM)方式采集数据并做定性筛查和定量分析。63种药物在相应的浓度范围内线性关系良好,相关系数均大于0.99;不同畜禽肉(猪肉、牛肉及鸡肉)在3个不同添加水平下的平均回收率为62.2%~112.0%,相对标准偏差(RSD)为3.1%~16.3%,检出限(LOD, S/N≥3)和定量限(LOQ, S/N≥10)分别为0.1~3.0 μg/kg和0.5~10.0 μg/kg。该方法简便快速、灵敏可靠,适用于畜禽产品中兽药多残留的同时快速定性筛查和定量分析。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号