共查询到20条相似文献,搜索用时 31 毫秒
1.
John H. Letcher 《Magnetic resonance imaging》1989,7(6):581-583
For a number of reasons, it is desirable to fabricate coils which, for a known current, shall produce predetermined values of the magnetic field intensity at a number of points within a nuclear magnetic resonance imager. The calculation of the magnetic field intensity at a set of points involves the integration of the Biot-Savart equation for all components of the segments of conductor which make up the coil. This process in itself is a rather formidable task. When this process is parameterized in terms of coil diameter, coil spacing, etc. the problem is to determine the values of these parameters to match values of magnetic field intensities which are desired. The problem thereby increases in complexity to the point where, by ordinary methods, the problem becomes intractable. This note describes an algorithm and offers a computer subroutine to calculate magnetic fields for coils of arbitrary shape and complexity for fixed currents. 相似文献
2.
Hirata H Itoh T Hosokawa K Deng Y Susaki H 《Journal of magnetic resonance (San Diego, Calif. : 1997)》2005,175(2):177-184
This article describes a systematic method for determining the cutoff frequency of the low-pass window function that is used for deconvolution in two-dimensional continuous-wave electron paramagnetic resonance (EPR) imaging. An evaluation function for the criterion used to select the cutoff frequency is proposed, and is the product of the effective width of the point spread function for a localized point signal and the noise amplitude of a resultant EPR image. The present method was applied to EPR imaging for a phantom, and the result of cutoff frequency selection was compared with that based on a previously reported method for the same projection data set. The evaluation function has a global minimum point that gives the appropriate cutoff frequency. Images with reasonably good resolution and noise suppression can be obtained from projections with an automatically selected cutoff frequency based on the present method. 相似文献
3.
In this article,a novel designed radio frequency (RF) coil is designed and built for the imaging of puppies in a V-shape permanent magnetic resonance imaging (MRI) system.Two sets of Helmholtz coil pairs with a V-shape structure are used to improve the holding of an animal in the coil.The homogeneity and the sensitivity of the RF field in the coil are analysed by theoretical calculation.The size and the shape of the new coil are optimized and validated by simulation through using the finite element method (FEM).Good magnetic resonance (MR) images are achieved on a shepherd dog. 相似文献
4.
一种基于减法运算的图象解卷积算法 总被引:1,自引:1,他引:1
分析了光学成象系统中点扩展函数的作用,采用减法运算从图象中消除了点扩展函数对图象造成的影响,从而实现了图象恢复.文章给出了该算法的流程及实例. 相似文献
5.
Measuring eye movements (EMs) using the search-coil eye-tracking technique is superior to video-based infrared methods [Collewijn H, van der Mark F, Jansen TC. Precise recording of human eye movements. Vision Res 1975;15(3):447-50], which suffer from the instability of pupil size, blinking behavior and lower temporal resolution. However, no conventional functional magnetic resonance imaging (fMRI)-compatible search-coil eye tracker exists. The main problems for such a technique are the interaction between the transmitter coils and the magnetic gradients used for imaging as well as the limited amount of space in a scanner. Here we present an approach to overcome these problems and we demonstrate a method to record EMs in an MRI scanner using a search coil. The system described has a spatial resolution of 0.07 degrees (visual angle) and a high temporal resolution (22 kHz). The transmitter coils are integrated into the visual presentation system and the control/analysis unit is portable, which enables us to integrate the eye tracker with an MRI scanner. Our tests demonstrate low noise in the recorded eye traces and scanning with minimal artifact. Furthermore, the induced current in the search coil caused by the RF pulses does not lead to measurable heating. Altogether, this MR-compatible search-coil eye tracker can be used to precisely monitor EMs with high spatial and temporal resolution during fMRI. It can therefore be of great importance for studies requiring accurate fixation of a target, or measurement and study of the subject's oculomotor system. 相似文献
6.
Nathan Kelso Seung-Kyun Lee Louis-S. Bouchard Vasiliki Demas Michael Mück Alexander Pines John Clarke 《Journal of magnetic resonance (San Diego, Calif. : 1997)》2009,200(2):285-290
MRI is a powerful technique for clinical diagnosis and materials characterization. Images are acquired in a homogeneous static magnetic field much higher than the fields generated across the field of view by the spatially encoding field gradients. Without such a high field, the concomitant components of the field gradient dictated by Maxwell’s equations lead to severe distortions that make imaging impossible with conventional MRI encoding. In this paper, we present a distortion-free image of a phantom acquired with a fundamentally different methodology in which the applied static field approaches zero. Our technique involves encoding with pulses of uniform and gradient field, and acquiring the magnetic field signals with a SQUID. The method can be extended to weak ambient fields, potentially enabling imaging in the Earth’s field without cancellation coils or shielding. Other potential applications include quantum information processing and fundamental studies of long-range ferromagnetic interactions. 相似文献
7.
One of the main problems with rapid magnetic resonance imaging (MRI) techniques is the artifacts that result from off-resonance effects. The proposed off-resonance frequency filtered MRI (OFF-MRI) method focuses on the elimination of off-resonance components from the image of the observed object. To maintain imaging speed and simultaneously achieve good frequency selectivity, MRI is divided into two steps: signal acquisition and post-processing. 相似文献
8.
A novel approach to designing cylindrical-surface shimcoils for a superconducting magnet of magnetic resonance imaging
下载免费PDF全文

For a superconducting magnet of magnetic resonance imaging (MRI), the novel approach presented in this paper allows the design of cylindrical gradient and shim coils of finite length. The method is based on identification of the weighting of harmonic components in the current distribution that will generate a magnetic field whose z-component follows a chosen spherical harmonic function. Mathematical expressions which relate the harmonic terms in the cylindrical current distribution to spherical harmonic terms in the field expansion are established. Thus a simple matrix inversion approach can be used to design a shim coil of any order pure harmonic. The expressions providing a spherical harmonic decomposition of the field components produced by a particular cylindrical current distribution are novel. A stream function was applied to obtain the discrete wire distribution on the cylindrical-surface. This method does not require the setting of the target-field points. The discussion referring to matrix equations in terms of condition numbers proves that this novel approach has no ill-conditioned problems. The results also indicate that it can be used to design cylindrical-surface shim coils of finite length that will generate a field variation which follows a particular spherical harmonic over a reasonably large-sized volume. 相似文献
9.
Brunner G Nambi V Yang E Kumar A Virani SS Kougias P Shah D Lumsden A Ballantyne CM Morrisett JD 《Magnetic resonance imaging》2011,29(8):1065-1075
Muscle volume measurements are essential for an array of diseases ranging from peripheral arterial disease, muscular dystrophies, neurological conditions to sport injuries and aging. In the clinical setting, muscle volume is not routinely measured due to the lack of standardized ways for its repeatable quantification. In this paper, we present magnetic resonance muscle quantification (MRMQ), a method for the automatic quantification of thigh muscle volume in magnetic resonance imaging (MRI) scans. MRMQ integrates a thigh segmentation and nonuniform image gradient correction step, followed by feature extraction and classification. The classification step leverages prior probabilities, introducing prior knowledge to a maximum a posteriori classifier. MRMQ was validated on 344 slices taken from 60 MRI scans. Experiments for the fully automatic detection of muscle volume in MRI scans demonstrated an averaged accuracy, sensitivity and specificity for leave-one-out cross-validation of 88.3%, 93.6% and 87.2%, respectively. 相似文献
10.
11.
12.
The theory of diffusion gradient-weighted MRI (DGWI) is presented in this paper. The Bloch-Torrey equation was modified to include the effect of intravoxel spatial-location variation of water diffusion (diffusion gradient) on MRI signal, in addition to the effect of intravoxel spatial-direction variation of water diffusion (diffusion anisotropy). An analytical solution for a diffusion-encoding spin-echo pulse sequence was derived. Unlike water diffusion which attenuates the image signal intensity, this newly derived solution relates the spatial gradient of the water diffusion with the phase of the image signal. This novel MRI technique directly measures both the water diffusion and its spatial gradient, and thus offers a noninvasive imaging tool to simultaneously investigate the intravoxel inhomogeneity and anisotropy of tissue structures. In addition, as demonstrated with our preliminary data, this new method may be utilized to delineate the interfaces of tissues with different diffusion. This method is an extension of the successful diffusion tensor MRI (DTI), but requires no additional data acquisition. In addition to the measured diffusion tensor, this new method provides measurements of the spatial derivatives of the three principal diffusivities of the tensor, thereby providing additional information for improving white matter fiber tractography. 相似文献
13.
Suchandrima Banerjee Esin Ozturk-Isik Sarah J. Nelson Sharmila Majumdar 《Magnetic resonance imaging》2009
Magnetic Resonance Spectroscopic Imaging (MRSI) is a technique for imaging spatial variation of metabolites and has been very useful in characterizing biochemical changes associated with disease as well as response to therapy in malignant pathologies. This work presents a self-calibrated undersampling to accelerate 3D elliptical MRSI and an extrapolation-reconstruction algorithm based on the GRAPPA method. The accelerated MRSI technique was tested in three volunteers and five brain tumor patients. Acceleration allowed larger spatial coverage and consequently, less lipid contamination in spectra, compared to fully sampled acquisition within the same scantime. Metabolite concentrations measured from the accelerated acquisitions were in good agreement with measurements obtained from fully sampled MRSI scans. 相似文献
14.
15.
In pharmacological magnetic resonance imaging (phMRI) with anesthetized animals, there is usually only a single time window to observe the dynamic signal change to an acute drug administration since subsequent drug injections are likely to result in altered response properties (e.g., tolerance). Unlike the block-design experiments in which fMRI signal can be elicited with multiple repetitions of a task, these single-event experiments require stable baseline in order to reliably identify drug-induced signal changes. Such factors as subject motion, scanner instability and/or alterations in physiological conditions of the anesthetized animal could confound the baseline signal. The unique feature of such functional MRI (fMRI) studies necessitates a technique that is able to monitor MRI signal in a real-time fashion and to interactively control certain experimental procedures. In the present study, an approach for real-time MRI on a Bruker scanner is presented. The custom software runs on the console computer in parallel with the scanner imaging software, and no additional hardware is required. The utility of this technique is demonstrated in manganese-enhanced MRI (MEMRI) with acute cocaine challenge, in which temporary disruption of the blood-brain barrier (BBB) is a critical step for MEMRI experiments. With the aid of real-time MRI, we were able to assess the outcome of BBB disruption following bolus injection of hyperosmolar mannitol in a near real-time fashion prior to drug administration, improving experimental success rate. It is also shown that this technique can be applied to monitor baseline physiological conditions in conventional fMRI experiments using blood oxygenation level-dependent (BOLD) contrast, further demonstrating the versatility of this technique. 相似文献
16.
Reconstruction of dynamic contrast enhanced magnetic resonance imaging of the breast with temporal constraints 总被引:1,自引:0,他引:1
A number of methods using temporal and spatial constraints have been proposed for reconstruction of undersampled dynamic magnetic resonance imaging (MRI) data. The complex data can be constrained or regularized in a number of different ways, for example, the time derivative of the magnitude and phase image voxels can be constrained separately or jointly. Intuitively, the performance of different regularizations will depend on both the data and the chosen temporal constraints. Here, a complex temporal total variation (TV) constraint was compared to the use of separate real and imaginary constraints, and to a magnitude constraint alone. Projection onto Convex Sets (POCS) with a gradient descent method was used to implement the diverse temporal constraints in reconstructions of DCE MRI data. For breast DCE data, serial POCS with separate real and imaginary TV constraints was found to give relatively poor results while serial/parallel POCS with a complex temporal TV constraint and serial POCS with a magnitude-only temporal TV constraint performed well with an acceleration factor as large as R=6. In the tumor area, the best method was found to be parallel POCS with complex temporal TV constraint. This method resulted in estimates for the pharmacokinetic parameters that were linearly correlated to those estimated from the fully-sampled data, with Ktrans,R=6=0.97 Ktrans,R=1+0.00 with correlation coefficient r=0.98, kep,R=6=0.95 kep,R=1+0.00 (r=0.85). These results suggest that it is possible to acquire highly undersampled breast DCE-MRI data with improved spatial and/or temporal resolution with minimal loss of image quality. 相似文献
17.
Hutchinson M Schiffer W Joseffer S Liu A Schlosser R Dikshit S Goldberg E Brodie JD 《Magnetic resonance imaging》1999,17(10):1808-1436
In general, image analysis of cognitive experiments using functional magnetic resonance imaging techniques has emphasized those regions of the brain where increases in signal intensity, with regard to the reference state, are associated with activation. Nevertheless, a number of recent papers have shown that there are areas of deactivation as well. In this study, we have used a univariate analysis and echo-planar functional magnetic resonance imaging to address the relationship of the reference state to the deactivations. We employed two dichotomous covert tasks, orthographic lexical retrieval and pure visual retrieval, to contrast with the reference state (baseline) of silent counting. Our analysis yielded extensive, task-specific landscapes of regional incremental and decremental responses. We have specifically demonstrated that the decremental responses are not due to activation in the reference state. We have also demonstrated that they are not an artifact of a specific part of the image analysis, and propose that they represent a physiological, task specific signal that should be considered an integral component of neural networks representing brain function. 相似文献
18.
Jason A. Pates Mustapha R. Hatab Donald D. McIntire F. Gary Cunningham Diane M. Twickler 《Magnetic resonance imaging》2010
Objective
The purpose of this study is to determine the feasibility of measuring total uterine blood flow in pregnancy using magnetic resonance imaging (MRI) technique.Methods
Uterine blood flow was determined in pregnant women in whom MRI was being carried out to assess a fetal anomaly. A two-dimensional time-of-flight magnetic resonance (MR) angiogram sequence was performed. Scout images and a peripherally gated phase contrast MR sequence were planned to study simultaneous blood flow in the uterine and ovarian arteries.Results
The MR pelvic angiogram sequence was completed in 13 women. The uterine arteries were visualized and their cross-sectional area determined. The complexity of the pelvic blood supply prevented the calculation of blood flow velocity and, thus, total uterine blood flow.Conclusion
The measurement of total uterine blood flow during pregnancy was not possible using our MR technique. The ovarian vessels were not consistently visualized. Doppler ultrasonography remains the best modality by which to estimate total uterine blood flow in pregnancy. 相似文献19.
Magnetic resonance (MR) perfusion imaging is a clinical technique for measuring brain blood flow parameters during stroke and other ischemic events. Ischemia in brain tissue can be difficult to accurately measure or visualize when using MR-derived cerebral blood flow (CBF) maps. The deconvolution techniques used to estimate flow can introduce a mean transit time-dependent bias following application of noise stabilization techniques. The underestimation of the CBF values, greatest in normal tissues, causes a decrease in the image contrast observed in CBF maps between normally perfused and ischemic tissues; resulting in ischemic areas becoming less conspicuous. Through application of the proposed simple extrapolation technique, CBF biases are reduced when missing high-frequency signal components in the MR data removed during deconvolution noise stabilization are restored. The extrapolation approach was compared with other methods and showed a statistically significant increase in image contrast in CBF maps between normal and ischemic tissues for white matter (P<.05) and performed better than most other methods for gray matter. Receiver operator characteristic curve analysis demonstrated that extrapolated CBF maps better-detected penumbral regions. Extrapolated CBF maps provided more accurate CBF estimates in simulations, suggesting that the approach may provide a better prediction of outcome in the absence of treatment. 相似文献
20.
An innovative algorithm is presented which is effective in reducing the truncation artefacts occurring in magnetic resonance images due to missing k-space samples. The algorithm works first by filling the incomplete matrix of coefficients with zeroes and then adjusting, by an iterative process, the missing coefficients by performing a reduction of the undersampling artefacts. Then, this set of coefficients is used as a basis for a superresolution algorithm that estimates the missing coefficients by modeling the data as a linear combination of increasing and decreasing exponential functions using Prony's method. In fact, the Prony's method consists of the interpolation of a given data set with a sum of exponential functions: the MRI signals can be well represented as a sum of exponential functions and the missing data can be extrapolated by this representation. The algorithm has been proven to perform better than either a simple algorithm, which detects and then reduces the undersampling artefacts, or an algorithm that models the measured data with approximation functions. The presented algorithm is quite simple and is applicable both to missing rows (phase-frequency acquisitions) and to radial-missing angle (acquisition from projections) undersampling. Experimental results are reported; comparisons, made between the results obtained using the presented algorithm and the alternative methods described above, clearly demonstrate the superiority of the algorithm. 相似文献