1.
Sun LX  Matsuda N  Takatsu A  Kato K  Okada T 《Talanta》2005,65(5):1143-1148
A slab optical waveguide (SOWG) has been used for study of adsorption of both methylene blue (MB) and new methylene blue (NMB) in liquid–solid interface. Adsorption characteristics of MB and NMB on both bare SOWG and silanized SOWG by octadecyltrichlorosilane (ODS) were compared. Effect of pH on adsorption on MB and NMB was investigated. Binding rate constant analysis showed that both MB and NMB on bare SOWG demonstrates larger association constants than those on ODS-SOWG. Interactions of MB and NMB on bare SOWG and ODS-SOWG were analyzed by molecular mechanics calculation method. The binding energy change was in the following order: ENMB–bare > EMB–bare > ENMB–ODS > EMB–ODS.  相似文献   

2.
Takahashi K  Koitabashi M  Kusu F 《Talanta》2005,65(5):1120-1125
A new spectroelectrochemical cell for slab optical waveguide (SOWG) spectroscopy was developed in order to observe in situ an electrode/electrolyte interface for bulk electrolysis. The new SOWG spectroelectrochemical cell has been evaluated by simultaneous electrochemical-absorption experiments of methylene blue (MB) using cyclic voltammetry (CV) and SOWG spectrometry. CV was performed in the SOWG spectroelectrochemical cell using indium tin oxide (ITO) coated glass as the working electrode, platinum wire as the counter electrode and a silver/silver chloride electrode (Ag/AgCl) as the reference electrode. Based on the CV and SOWG spectrometric data, it was found that the SOWG spectra showed the MB spectra on the electrode surface selectively and that SOWG with the cell would be useful as a tool for in situ study of an electrode/electrolyte interface. Using this cell, the effects of the supporting electrolytes, NaNO3, KNO3, CH3COONa, and CH3COOK on the absorbance of MB were examined at the potential of +0.8 V versus Ag/AgCl. The decrease in MB absorbance by nitrate ions was greater than that of acetate ions. Therefore the competitive adsorption of nitrate ions was stronger than that of acetate ions. Thus, the decrease in absorbance of MB in the presence of anions demonstrates the competitive adsorption of anions. These results show that the extent of specific adsorption of electrolytes was observed by measuring the SOWG absorbance intensity of MB.  相似文献   

3.
The orientation of molecular chains in polymers cannot be easily extracted from ATR spectra measurements. One can infer the orientation parameters by using plausible models that describe the type of the statistical distribution of the molecular chains in the sample. In this work, we are interested in the case of weakly aligned polymers. Therefore, we first adjusted the partial axial orientation model usually applied for strongly oriented polymers to the samples under our investigations and second, related the parameters describing the orientation configuration to the dichroic ratios in four particular molecular chain distributions: randomly, totally, partially, and elliptically oriented. A new method that leads to the determination of these dichroic ratios from ATR spectra is presented. This method is based only on the use of three distinct polarizations of the beam. Thus, all the practical difficulties usually encountered in the other methods are eliminated. © 1997 John Wiley & Sons, Inc. J Polym Sci B: Polym Phys 35 : 1361–1372, 1997  相似文献   

4.
A slab optical waveguide (SOWG) has been used for study of adsorption of both methylene blue (MB) and new methylene blue (NMB) in liquid-solid interface. Adsorption characteristics of MB and NMB on both bare SOWG and silanized SOWG by octadecyltrichlorosilane (ODS) were compared. The simultaneous determinations of both MB and NMB were explored by flow injection SOWG spectrophotometric analysis and artificial neural networks (ANNs) for the first time. Concentrations of MB and NMB were estimated simultaneously with the ANNs. Results obtained with SOWG were compared with those got by conventional UV-visible spectrophotometry.  相似文献   

5.
Umemura T  Kasuya Y  Odake T  Tsunoda K 《The Analyst》2002,127(1):149-152
Attenuated total reflection spectrometry with a slab optical waveguide (SOWG) was explored for the simple, rapid and sensitive measurement of total anionic surfactants by the methylene blue active substance (MBAS) method. A fused-silica sheet used as a guiding layer was modified with trimethylsilane (TMS) to extract and concentrate the MBASs on the SOWG surface. Based on preliminary studies of the adsorption behavior and visible ATR spectrum of MB on the modified silica surface, a detection wavelength of 600 nm was chosen for the sensitive measurement of anionic surfactants. When the concentration of MB was set at 10 microM in the final measurement solution, the calibration curve for a typical anionic surfactant (sodium dodecylbenzenesulfonate) was linear up to 0.6 microM and the detection limit was 0.07 microM. The proposed method was applied to the determination of total anionic surfactants in river water.  相似文献   

6.
An investigation into the rapid detection of mycotoxin-producing fungi on corn by two mid-infrared spectroscopic techniques was undertaken. Corn samples from a single genotype (RWA2, blanks, and contaminated with Fusarium graminearum) were ground, sieved and, after appropriate sample preparation, subjected to mid-infrared spectroscopy using two different accessories (diffuse reflection and attenuated total reflection). The measured spectra were evaluated with principal component analysis (PCA) and the blank and contaminated samples were classified by cluster analysis. Reference data for fungal metabolites were obtained with conventional methods. After extraction and clean-up, each sample was analyzed for the toxin deoxynivalenol (DON) by gas chromatography with electron capture detection (GC-ECD) and ergosterol (a parameter for the total fungal biomass) by high-performance liquid chromatography with diode array detection (HPLC-DAD). The concentration ranges for contaminated samples were 880–3600 g/kg for ergosterol and 300–2600 g/kg for DON. Classification efficiency was 100% for ATR spectra. DR spectra did not show as obvious a clustering of contaminated and blank samples. Results and trends were also observed in single spectra plots. Quantification using a PLS1 regression algorithm showed good correlation with DON reference data, but a rather high standard error of prediction (SEP) with 600 g/kg (DR) and 490 g/kg (ATR), respectively, for ergosterol. Comparing measurement procedures and results showed advantages for the ATR technique, mainly owing to its ease of use and the easier interpretation of results that were better with respect to classification and quantification.  相似文献   

7.
We tried to develop a library search system using a portable, attenuated total reflection Fourier transform infrared (ATR-FT-IR) spectrometer for on-site identification of 3,4-methylenedioxymethamphetamine (MDMA) and 3,4-methylenedioxyamphetamine (MDA) tablets. The library consisted of the spectra from mixtures of controlled drugs (e.g. MDMA and ketamine), adulterants (e.g. caffeine), and diluents (e.g. lactose). In the seven library search algorithms, the derivative correlation coefficient showed the best discriminant capability. This was enhanced by segmentation of the search area. The optimized search algorithm was validated by the positive (n = 154, e.g. the standard mixtures containing the controlled drug, and the MDMA/MDA tablets confiscated) and negative samples (n = 56, e.g. medicinal tablets). All validation samples except for four were judged truly. Final criteria for positive identification were decided on the basis of the results of the validation. In conclusion, a portable ATR-FT-IR spectrometer with our library search system would be a useful tool for on-site identification of amphetamine-type stimulant tablets.  相似文献   

8.
Attenuated total internal reflection (ATR) spectroscopy with an s- or p-polarized visible light was examined for some species of protonated 5,10,15,20-tetraphenylporphine (tpp) at toluene/aqueous H2SO4 (3-6 mol dm−3) interface. Tpp initially dissolved in the toluene phase was diprotonated at the interface to form monomeric H2tpp2+, the absorption peak of which was 438 nm. At the same time, a long H2tpp2+ oligomer was formed, the absorption peak of which was 448 nm. The two interfacial species were transient. Just after their disappearance, a rod-shaped H2tpp2+ associate was formed at the interface, the absorption peak of which was 417 and 478 nm. The former and latter wavelengths corresponded to H- and J-bands of the associate, respectively. Theoretical calculation of the strength of electric field of light at the interface allowed one to estimate the interfacial concentration of the three species with measured reflection absorbance (AR). The monomeric H2tpp2+ and its oligomer were at sub-monolayer levels, whereas the associate was at a multilayer level. Reflection absorption anisotropy (KR), which was calculated from AR with the s- and p-polarized lights, was adopted for the evaluation of out-of-plane orientation of the interfacial species for the first time. The KR value suggested that the rod-shaped associate lay at the interface.  相似文献   

9.
10.
A compact measurement system based on a novel combination of cantilever enhanced photoacoustic spectroscopy (CEPAS) and optical parametric oscillator (OPO) was applied to the gas phase measurement of benzene, toluene, and o-, m- and p-xylene (BTX) traces. The OPO had a band width (FWHM) of 1.3 nm, was tuned from 3237 to 3296 nm in steps of 0.1 nm and so spectra of BTX at different concentrations were recorded. The power emitted by the OPO increased from 88 mW at 3237 nm to 103 mW at 3296 nm. The univariate detection limits (3σ, 0.951 s) for benzene, toluene, p-, m- and o-xylene at 3288 nm were 12.0, 9.8, 13.2, 10.1 and 16.0 ppb, respectively. Multivariate data analysis using science-based calibration was used to resolve the interference of the analytes. The multivariate detection limits (3σ, 3237–3296 nm, 591 spectral points each 0.951 s) for benzene, toluene, p-, m- and o-xylene in the multi-compound sample, where all other analytes and water interfere were 4.3, 7.4, 11.0, 12.5 and 6.2 ppb, respectively. Without interferents, the multivariate detection limits varied between 0.5 and 0.6 ppb. The sum of the cross-selectivities (3237–3296 nm, 591 spectral points, each 0.951 s) per analyte were below 0.05 ppb/ppb, with an average of 0.038 ppb/ppb. The cross-selectivity of water to the analytes was on average 1.22 × 10−4 ppb/ppb. The OPO is small in size (L × W × H 125 × 70 × 45 mm), commercially available, and easy to operate and integrate to setups. The combination with sensitive CEPAS enables compact measurement systems for industrial as well as environmental trace gas monitoring.  相似文献   