首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

The change in the thermodynamic properties of triclosan adsorption on three activated carbons with the different surface chemistry was studied through immersion calorimetry and equilibrium data; the amount adsorbed of triclosan (Q) during calorimetry was determined and correlated with the energy associated with adsorbate–adsorbent interactions in the adsorption process. It was noted that triclosan adsorption capacity decreases with an increase in oxygenated surface groups. For an activated carbon oxidized with HNO3 (OxAC), the amount adsorbed was 8.50?×?10?3 mmol g?1, for a activated carbon without modification (GAC) Q?=?10.3?×?10?3 mmol g?1 and for a activated carbon heated at 1073 K (RAC1073) Q?=?11.4?×?10?3 mmol g?1. The adsorbed amounts were determined by adjusting the isotherms to the Sips model. For the activated carbon RAC1073, the immersion enthalpy (ΔHimm) was greater than those of the other two activated carbons due to the formation of interactions with the solvent (ΔHimmOxAC?=?? 27.3 J g?1?<?ΔHimmGAC?=?? 40.0 J g?1?<?ΔHimm RAC1073?=???60.7 J g?1). The changes in the interaction enthalpy and Gibbs energy are associated with adsorbate–adsorbent interactions and side interactions such as the adsorbate–adsorbate and adsorbate–solvent interactions.

  相似文献   

2.

Tritium concentration was monitored in different water sources collected around Kaiga Nuclear Power plant, India. The concentration was in the ranges?<?1.9–27.4 Bq L?1 (GM?=?4.0 Bq L?1) for groundwater,?<?1.9–42.1 Bq L?1 (GM?=?3.5 Bq L?1) for surface water and in 12.4–42.0 Bq L?1 (GM?=?24.07 Bq L?1) for reservoir water. The concentration values observed in this study are similar to those reported for other PHWR stations of the world. The radiation dose to the public due to ingestion of Tritium through groundwater was computed to be 0.08 μSvy?1.

  相似文献   

3.
Zhang  Xue  Yu  Hong  Cai  Ya-qi 《Analytical and bioanalytical chemistry》2019,411(16):3427-3434

An ion chromatography and solid-phase extraction method has been applied for the separation and detection of morpholinium cations in environmental water samples. The water samples were purified and enriched by a UF-SCX sulfonic acid extraction column and eluted with 0.5 mol L−1 phosphoric acid/sodium dihydrogen phosphate buffer solution/55% methanol. The target compounds were separated on a carboxylic acid cation exchange column with 5.0 mmol L−1 methane sulfonic acid/2% acetonitrile as the mobile phase and direct conductivity detection. The method has been successfully applied to extract morpholinium cations from spiked water samples of Songhua River, Hulan River, East Lake, and Mopanshan Reservoir in China with the recoveries ranging from 75.0% to 98.3%. The relative standard deviations of intraday precision and interday precision are 2.1% and 5.9% or less, respectively. Using this method it is possible to preconcentrate water samples to 0.01–0.04 mg L−1. The results show that the method is applicable to detection of morpholinium ionic liquid cations in environmental water samples and provides a new approach for monitoring ionic liquids in environmental water.

The analysis procedure of morpholinium ionic liquids in environmental water samples.

  相似文献   

4.

Magnetic graphene oxide/lanthanum phosphate nanocomposite (MGO@LaP) was synthesized and used as an efficient adsorbent for magnetic dispersive microsolid-phase extraction (MD-µ-SPE) of pesticides before gas chromatography–electron capture detector (GC–ECD) analysis. The adsorbent was thoroughly characterized with scanning electron microscopy, vibrating sample magnetometer, energy-dispersive X-ray spectroscopy, and Fourier transform infrared spectroscopy. Optimized extraction conditions were investigated concerning extraction time, adsorbent amount, sample pH, and salt amount as well as desorption conditions (type and volume of desorption solvent and desorption time). Under the optimal conditions, the method demonstrated good linearity (3–1500 µg L?1) with satisfactory determination coefficients of >?0.997 and low detection limits for both chlorpyrifos (0.67 µg L?1) and hexaconazole (0.89 µg L?1). Finally, the method showed high analyte relative recoveries in the range of 78–120% for the determination of the selected pesticides in water and fruit juice samples.

  相似文献   

5.
A flow-injection chemiluminescence (CL) method for the determination of melatonin based on the CL reaction of melatonin with hydrogen peroxide and sodium hypochlorite (NaOCl) in a basic alkaline solution was developed. The possible CL mechanism has been discussed, and a proposal for the reaction pathway was given that singlet oxygen was clarified to be produced in this reaction system and was responsible for the CL emission. Under the optimized conditions, the linear concentration range of application was 1.0×10^-7-2.5 × 10^-4 moloL-I with a de- tection limit of 5.0 ×10^-8 moloL-1 (S/N= 3). The relative standard deviation for eight repeated measurements of 1.0×10^-6 mol·L^-1 melatonin was 2.8%. The interferences of several important biological substances, some indole compound, cations and anions were studied. No interference was found for the anions, glucose, starch, most of cations and low concentration (less than 3.0 × 10^-6 mol·L^-1) of some biological substances and indole compound. The method was applied to the determination of melatonin in rat pineal gland and drug with satisfactory results. The sample throughput was 90 injections per hour.  相似文献   

6.
A reliable multiclass method has been developed and validated for the determination of eight antibiotics from distinct classes (sulfonamides, macrolides, fluoroquinolones, tetracyclines, cephalosporins and dihydrofolate reductase inhibitors) in wastewater – influent and effluent – and surface water from Porto Alegre, Brazil. The pre-concentration and clean-up was conducted with a simple and fast protocol using solid-phase extraction allowing a 100-fold concentration factor. The proposed method was validated by using spiked blank wastewater samples in terms of linearity, repeatability, reproducibility, recovery, matrix effects and limits of detection and quantification. Recovery was obtained in the range of 66–149%. Method limit of quantification ranged between 1.6 and 61.7 ng L?1. Samples (n = 16) were taken from January to August 2011 in one wastewater treatment plant, which uses conventional biological treatment. Sulfamethoxazole and trimethoprim show higher concentration, ranging from >10 to <6500 ng L?1, whereas erythromycin presented the lower amount. Differences between influent and effluent profiles were discussed. Surface water samples (n = 8) were collected in Arroio Diluvio, in four sampling points, in February 2012. From the eight antibiotics analysed, five were detected: sulfamethoxazole, trimethoprim, azythromicyn, ciprofloxacin and norfloxacin, in a concentration range of 376–572 ng L?1, 27–94 ng L?1, 24–40 ng L?1, 16–66ng L?1 and 30–54 ng L?1, respectively.  相似文献   

7.
In this paper a simple and highly sensitive electroanalytical method for the determination of caffeine content using 1,4-benzoquinone modified carbon paste electrode is presented. The method is based on suppression of 1,4-benzoquinone peak current on addition of caffeine. Square-wave and cyclic voltammetric techniques were utilised for the investigation. The 1,4-benzoquinone modified electrode exhibited a well-defined peak with reproducible peak current values for repetitive measurements; and showed a decrease in peak current value with an increase in caffeine content. The result revealed two linear range regions between 0 mmol L−1 and 0.5 mmol L−1 and 0.5 mmol L−1 and 8.0 mmol L−1, with detection limits of 0.3 μmol L−1 and 5.1 μmol L−1, respectively. The method was then successfully applied to the determination of caffeine content in coffee samples. The effects of pH, electrode composition, step potential, pulse amplitude and square-wave frequency on the voltammetric responses were also investigated.  相似文献   

8.
Lead is the non-essential trace element in the human body, and it has been confirmed that drinking water is one of the sources of lead in human body. In the research, based on the sensitive colour reaction of lead with I?–EV+–PVA, a simple, sensitive, accurate and portable method for the determination of trace lead in drinking waters was proposed. Chemicals and physicals had been optimized in detail. The apparent molar absorption coefficient was up to 7.4 × 105 mol L?1 cm?1. The developed method provided a linearity range over 5–80 μg L?1. The regression deviation was between 0.71% and 2.33%. The 3σ detection limit was 0.9 μg L?1. Close to the quantitation limit for the analyte the relative standard deviation was 1.10% (n = 10) at 40 μg L?1. The method developed here for analysis of lead yielded results that were comparable with those of the GFAAS.  相似文献   

9.
Lucigenin chemiluminescence (CL) in conjunction with flow-injection analysis (FIA) is used for the determination of phosphate in freshwater samples. The procedure is based on the formation of molybdophosphoric heteropoly acid (MoP–HPA) by the reaction of phosphate and ammonium molybdate under acidic conditions. CL emission was observed as a result of oxidation of lucigenin in aqueous sodium hydroxide solution in the presence of MoP–HPA. Calibration was linear up to 500?µg?L?1 (r 2?=?0.9998; n?=?8), with a detection limit (S/N?=?3) of 0.95?µg?L?1. An injection throughput of 120 h?1, and relative standard deviation (RSD; n?=?4) of 1.3–3.2% were achieved in the concentration range studied. An on-line chelating column was used to remove interfering cations. The method was applied to freshwater samples, and the results (51?±?1.0 – 107?±?2.0?µg?L?1) did not differ significantly from results obtained using a spectrophotometric method (52.5?±?1.0 – 102?±?2.0?µg?L?1) at 95% confidence level (t-test).  相似文献   

10.
《Analytical letters》2012,45(17):2747-2757
Abstract

Brazilian sugarcane spirits were analyzed to elucidate similarities and dissimilarities by principal component analysis. Nine aldehydes, six alcohols, and six metal cations were identified and quantified. Isobutanol (LD 202.9 µg L?1), butiraldehyde (0.08–0.5 µg L?1), ethanol (39–47% v/v), and copper (371–6068 µg L?1) showed marked similarities, but the concentration levels of n-butanol (1.6–7.3 µg L?1), sec-butanol (LD 89 µg L?1), formaldehyde (0.1–0.74 µg L?1), valeraldehyde (0.04–0.31 µg L?1), iron (8.6–139.1 µg L?1), and magnesium (LD 1149 µg L?1) exhibited differences from samples.  相似文献   

11.
The developed method for trace analysis of volatile components in plasma allows direct injection of up to 150 samples to the GC–MS/MS system without injector cleaning. This method requires no modification of plasma and the working environment does not interfere with the determination of these analytes. The method allows simultaneous quantification of non-polar sevoflurane and its polar metabolite hexafluoroisopropanol (free, unconjugated form). It is characterized by high repeatability and sensitivity with the detection limit of 0.009 mg L?1 for sevoflurane and 0.018 mg L?1 for hexafluoroisopropanol and the linear range 0.050–150 mg L?1. The method was used to determine the concentration of sevoflurane and hexafluoroisopropanol in plasma samples of 7 patients undergoing general anesthesia with sevoflurane. The average concentration of sevoflurane and free hexafluoroisopropanol was 57.2 mg L?1 and 0.39 mg L?1, respectively. The method can be applied for clinical monitoring, as well as for analytical toxicology.  相似文献   

12.
A simple, rapid, sensitive, and inexpensive method for spectrophotometric determination of chromium(VI), based on the absorbance of its complex with 1,4,8,11-tetraazacyclotetradecane (cyclam) is presented. The complex showed a molar absorbtivity of 1.5?×?104?L?mol?1?cm?1 at 379?nm. Under optimum experimental conditions, a pH of 4.5 and 1.960?×?103?mg?L?1 cyclam were selected, and all measurements were performed 10?min after mixing. Major cations and anions did not show any interference; Beer's law was applicable in the concentration range 0.2–20?mg?L?1 with a detection limit of 0.001?mg?L?1. The standard deviation in the determination is ±0.5?mg?L?1 for a 15.0?mg?L?1 solution (n?=?7). The described method provides a simple and reliable means for determination of Cr(VI) in real samples.  相似文献   

13.

The activity concentrations of 226Ra, 228Ra and 222Rn were measured in 87 groundwater samples to estimate the activity concentrations of these radionuclides and health impact due to intake of these radionuclides in groundwater of Jordan. The mean activity concentrations of 226Ra, 228Ra and 222Rn in groundwater were found to be 0.293?±?0.005 Bq L?1, 0.508?±?0.009 Bq L?1 and 58.829?±?8.824 Bq L?1, respectively. They give a mean annual effective dose of 0.481 mSv with mean lifetime risk of 24.599?×?10?4, exceeding the admissible limit of 10?4. Most of the received annual effective dose (59.15% of the total) is attributed to 228Ra.

  相似文献   

14.

The effect of EDTA-masking on the alpha-spectral characteristics corresponding to uranium analysis in ground- and seawater samples after cation-exchange and electrodeposition is systematically investigated. Addition of EDTA (1 mmol l?1) to the investigated samples results in dramatic increase of the spectra quality, including improvement of the separation efficiency up to 75% and 85% for ground and seawaters, respectively. For EDTA concentrations lower than 1 mmol l?1 the spectral resolution and counting efficiencies decline, whereas for higher concentrations the resolution increases but the separation efficiency decreases due to the U(VI) stabilization in solution.

  相似文献   

15.
This study reports a deep eutectic solvent based dispersive liquid-liquid microextraction (DES-DLLME) to extract aromatic amines (4-chloroaniline, 3-nitroaniline, 2-naphtylamine) in environmental water samples before their HPLC-UV determination. The hydrophobic deep eutectic solvent (DES) was prepared by mixing bis(2-ethylhexyl) phosphate (BEHP) as a hydrogen bond acceptor and phenol as a hydrogen bond donor. Affecting factors on the extraction of the aromatic amines were investigated and optimized. Optimum conditions were: DES type: BHHP-Ph ratio: 1 to 2; pH of solution: 8.0; DES volume: 80 µL, salt amount: 10% (w/v). Under optimum conditions, the developed method showed a wide linear range of 0.2–200 µg L?1 (R2 ≥ 0.99) with satisfactory recoveries (≥90.0%). The limit of detections (LODs) and limit of quantifications (LOQs) were in the range of 0.07–0.17 µg L?1 and 0.2–0.5 µg L?1, respectively. The enrichment factors were 170, 180 and 190 for 4-chloroaninile, 3-nitroaniline, 2-naphtylamine, respectively. Based on obtained results, the proposed method is straightforward, efficient, sensitive, and eco-friendly for the extracting and determining of the aromatic amines in environmental water samples.  相似文献   

16.
A single‐piece solid‐contact Pb2+‐selective electrode was prepared by adding a thiophene oligomer into the ion‐selective cocktail directly. The one‐step fabrication yielded an electrode with Nernstian response spanning a wide concentration range of 10?3–10?8 mol L?1, and detection limit as low as 5.6×10?9 mol L?1. The electrode had a quick response time of approximately 10–15 s and showed excellent selectivity over the most common univalent and divalent cations. The practical application of the proposed electrode has been tested by determining Pb2+ in real water samples.  相似文献   

17.
Zhang  Qianchun  Wang  Yutong  Yang  Bingnian  Bao  Linchun  Wu  Yun  Wang  Xingyi 《Chromatographia》2022,85(8):733-741

Estrogen plays a crucial role in various stages of human development and is present in the human body at trace level; therefore, an efficient strategy for the quantitative analysis of trace estrogens is required. However, this analysis is complicated by the presence of extremely complex biological matrices. To address this challenge, a novel method based on monolithic column solid-phase microextraction and ultra-high-performance liquid chromatography-tandem mass spectrometry was developed for the sensitivity analysis of six estrogens: β-estradiol, α-estradiol, 17α-ethynylestradiol, estrone, diethylstilbestrol, and hexestrol, in human urine and serum samples. The method exhibits a low limit of detection (8.6–37 ng L?1), with wide linear ranges (0.10–25 μg L?1) for each analyte and remarkable correlation coefficients (R2?=?0.9953–0.9995). The developed method was successfully used to detect estrogens in urine and serum samples. The six analytes were satisfactorily recovered between 76.2 and 107% with relative standard deviations ranging from 2.5 to 8.3% (n?=?3). The results demonstrated that the developed method, based on a poly(methacrylic acid/3-acrylamidophenylboronic acid-co-ethylene glycol dimethacrylate) monolithic column, is an effective enrichment approach toward the analysis of trace estrogens in human urine and serum samples.

Graphical abstract
  相似文献   

18.
《Electroanalysis》2017,29(5):1267-1277
Graphite rod (GR) modified with electrochemicaly deposited gold nanoparticles (AuNPs) and adsorbed glucose oxidase (GOx) was used in amperometric glucose biosensor design. Enzymatic formation of polypyrrole (Ppy) on the surface of GOx/AuNPs/GR electrode was applied in order to improve analytical characteristics and stability of developed biosensor. The linear glucose detection range for Ppy/GOx/AuNPs/GR electrode was dependent on the duration of Ppy‐layer formation and the linear interval was extended up to 19.9 mmol L−1 after 21 h lasting synthesis of Ppy. The sensitivity of the developed biosensor was determined as 21.7 μA mM−1 cm−2, the limit of detection – 0.20 mmol L−1. Ppy/GOx/AuNPs/GR electrodes demonstrated advanced good stability (the t 1/2 was 9.8 days), quick detection of glucose (within 5 s) in the wide linear interval. Additionally, formed Ppy layer decreased the influence of electroactive species on the analytical signal. Developed biosensor is suitable for the determination of glucose in human serum samples.  相似文献   

19.
This work proposes a spectrophotometric method for the determination of hydrogen peroxide during photodegradation reactions. The method is based on the reaction of H2O2 with amonium metavanadate in acidic medium, which results in the formation of a red-orange color peroxovanadium cation, with maximum absorbance at 450 nm. The method was optimized using the multivariate analysis providing the minimum concentration of vanadate (6.2 mmol L−1) for the maximum absorbance signal. Under these conditions, the detection limit is 143 μmol L−1. The reaction product showed to be very stable for samples of peroxide concentrations up to 3 mmol L−1 at room temperature during 180 h. For higher concentrations however, samples must be kept refrigerated (4 °C) or diluted. The method showed no interference of Cl (0.2-1.3 mmol L−1), NO3 (0.3-1.0 mmol L−1), Fe3+ (0.2-1.2 mmol L−1) and 2,4-dichlorophenol (DCP) (0.2-1.0 mmol L−1). When compared to iodometric titration, the vanadate method showed a good agreament. The method was applied for the evaluation of peroxide consumption during photo-Fenton degradation of 2,4-dichlorophenol using blacklight irradiation.  相似文献   

20.
A simple and fast reaction between 12-molybdophosphate heteropoly anion and the polymethine dye Astra Phloxine was used for the development of a new SIA method for the determination of orthophosphate. The suggested method has higher sensitivity and a broader calibration range than existing SIA methods. It can be used to detect phosphate in the range from 0.2 to 10 μmol L−1 with a detection limit of 0.1 μmol L−1 and an acceptable throughput of 20 samples h−1. The comparably low molybdate (5.6 mmol L−1) and dye (0.1 mmol L−1) concentrations led to an improvement in the stability of the base line. Inter-day reproducibility was better than 5%, while the intra-day RSD was in the range 0.8-3.5%. The method was used for the analysis of natural water samples and phosphorus-containing chemicals having a low content of orthophosphate.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号