首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.

A novel stability-indicating LC assay method was developed and validated for quantitative determination of olmesartan in bulk drugs and in pharmaceutical dosage form in the presence of degradation products generated from forced degradation studies. An isocratic, reversed phase LC method was developed to separate the drug from the degradation products, using an Ace5-C18 (250 mm × 4.6 mm, 5 μm) column, and 50 mM ammonium acetate (pH-5.5 by acetic acid) and acetonitrile (70:30 v/v) as a mobile phase. The detection was carried out at the wavelength of 235 nm. The olmesartan was subjected to stress conditions of hydrolysis (acid, base), oxidation, photolysis and thermal degradation. Degradation was observed for olmesartan in acid, base and in 30% H2O2 conditions. The drug was found to be stable in the other stress conditions attempted. The degradation products were well resolved from the main peak. The percentage recovery of olmesartan ranged from (99.89 to 100.95%) in pharmaceutical dosage form. The developed method was validated with respect to linearity, accuracy (recovery), precision, specificity and robustness. The forced degradation studies prove the stability-indicating power of the method.

  相似文献   

2.
A novel stability-indicating high-performance liquid chromatographic assay method was developed and validated for quantitative determination of nitazoxanide in bulk drugs and in pharmaceutical dosage form in the presence of degradation products generated from forced decomposition studies. An isocratic, reversed phase LC method was developed to separate the drug from the degradation products, using an Ace5- C18 (250 mm × 4.6 mm, 5 μm) column, and 50 mM ammonium acetate (pH 5.5 by acetic acid) and acetonitrile (55:45 v/v) as a mobile phase. The detection was carried out at a wavelength of 240 nm. The nitazoxanide was subjected to stress conditions of hydrolysis (acid, base), oxidation, photolysis and thermal degradation. Degradation was observed for nitazoxanide in base, acid and in 30% H2O2 conditions. The drug was found to be stable in the other stress conditions attempted. The degradation products were well resolved from the main peak. The percentage recovery of nitazoxanide was from (100.55 to 101.25%) in the pharmaceutical dosage form. The developed method was validated with respect to linearity, accuracy (recovery), precision, system suitability, specificity and robustness. The forced degradation studies prove the stability indicating power of the method.  相似文献   

3.
The objectives of this investigation were to establish a validated stability-indicating LC method for assay of carvedilol and to study the degradation behaviour of the drug under different ICH-recommended stress conditions. Chromatographic separation was achieved on a C18 column with 55:45 (%, v/v) acetonitrile–0.02 m phosphate buffer, pH 3.5, as mobile phase at a flow rate of 1.0 mL min?1; detection was by UV absorbance at 242 nm. The method was validated for linearity, precision, accuracy, robustness, specificity, and sensitivity, with the bulk drug. The drug was subjected to forced degradation and peaks of all the degradation products were well resolved from that of the pure drug, with significantly different retention times, which indicates the specificity and stability-indicating properties of the method. First-order degradation kinetics of carvedilol were observed under acidic and alkaline conditions. When the utility of the method was verified by analysis of the drug in marketed tablets and a nano-emulsion formulation, the assay was found to be 98.60–99.61 and 99.52–99.87, respectively. These results indicate the method can be successfully used for routine analysis of carvedilol in the bulk drug and in pharmaceutical dosage forms.  相似文献   

4.

A stability-indicating liquid chromatographic method was developed and validated for quantitative determination of olmesartan medoxomil (OLM) in coated tablets in the presence of degradation products generated under stress conditions. An isocratic LC separation was performed using a Phenomenex RP-18 column using a mobile phase consisting of water:triethylamine:acetonitrile (60:0.3:40 v/v/v, pH adjusted to 6.3 with phosphoric acid). The flow rate was 1.2 mL min−1 and the detection was achieved with a photodiode array detector set at 257 nm. The response was linear over a range of 10.0 to 30.0 μg mL−1 (r = 0.9999). The specificity and stability-indicating capability of the method was verified subjecting the reference substance and drug product to hydrolytic, oxidative, photolytic, and thermal stress conditions. The method showed a good and consistent recovery (100.2%) with low intra- and inter-day relative standard deviation (RSD) (≤1.0%). A considerable degradation occurred in all stress conditions and the degradation product was well resolved from the main peak. There was no interference of the excipients in the determination of the active pharmaceutical ingredient. Thus, the proposed method was found to be stability-indicating and can be used for routine analysis for quantitative determination of OLM in coated tablets without the interference of major degradation products.

  相似文献   

5.
A simple, selective, precise, and stability-indicating thin-layer chromatographic method has been developed and validated for analysis of the cephalosporins cefpodoxime proxetil, ceftriaxone sodium, ceftazidime pentahydrate, cefotaxime sodium, cefoperazone sodium, cefazolin sodium, and cefixime in the bulk drug and in pharmaceutical formulations. TLC was performed on aluminium sheets precoated with silica gel G 60F254 as stationary phase. The mobile phases chosen for development gave compact spots for all the drugs (R F values 0.43–0.60). The separated compounds were visualized as orange spots by spraying with Dragendorff’s reagent. Linear regression analysis data for the calibration plots revealed good linear relationships between response and amounts of the drugs with correlation coefficients ranging from 0.9977 to 0.9998 and determination coefficients ranging from 0.9954 to 0.9996 over the concentration ranges 5–25 μg per spot for cefpodoxime proxetil, ceftriaxone sodium, and ceftazidime pentahydrate and 10–50 μg per spot for cefotaxime sodium, cefoperazone sodium, cefazolin sodium, and cefixime. The method was validated for precision, recovery, and robustness. Limits of detection and quantitation for the drugs ranged from 0.35 to 2.48 and from 1.07 to 7.50 μg per spot, respectively. The method was successfully applied to analysis of the drugs in their pharmaceutical dosage forms with good precision and accuracy. The method can also be used as a stability-indicating assay.  相似文献   

6.

This paper discusses the development of a stability-indicating reversed-phase LC method for analysis of cholecalciferol as the bulk drug and in formulations. The mobile phase was acetonitrile–methanol–water 50:50:2 (v/v). The calibration plot for the drug was linear in the range 0.4–10 μg mL−1. The method was accurate and precise with limits of detection and quantitation of 64 and 215 ng, respectively. Mean recovery was 100.71%. The method was used for analysis of cholecalciferol in pharmaceutical formulations in the presence of its degradation products and commonly used excipients.

  相似文献   

7.
A simple, sensitive, selective, precise and stability-indicating thin-layer chromatographic method for determination of dutasteride both as a bulk drug and as pharmaceutical tablets was developed and validated as per the International Conference on Harmonization guidelines. The method employed thin-layer chromatography aluminium plates precoated with silica gel 60F254 as the stationary phase and the mobile phase consisted of acetonitrile:methanol:dichloromethane in the ratio of 2.0:1.0:2.0, v/v/v. This solvent system was found to give compact spots for dutasteride (R f value of 0.64 ± 0.02). Densitometric analysis of dutasteride was carried out in the absorbance mode at 244 nm. The linear regression analysis data for the calibration plots showed good linear relationship with r = 0.9943 with respect to peak area in the concentration range of 100–600 ng per band. The method was validated for precision, accuracy, ruggedness and recovery. The limits of detection and quantitation were 7.54 and 22.85 ng per band, respectively. Dutasteride was subjected to acid and alkali hydrolysis, oxidation, photo degradation, dry heat and wet heat treatment. The drug undergoes degradation under acidic, basic conditions, photolytic, oxidative and upon wet and dry heat treatment. The degraded products were well separated from the pure drug. The statistical analysis proves that the developed method for quantification of dutasteride as bulk drug and from pharmaceutical tablets is reproducible and selective. As the method could effectively separate the drug from its degradation products, it can be employed as stability-indicating.  相似文献   

8.
A sensitive, stability-indicating liquid-chromatographic method for analysis of racecadotril in the presence of its degradation products has been developed and validated. Efficient chromatographic separation was achieved on a C18 column with a simple isocratic mobile phase—60:40 methanol–water. Quantification was by photo-diode array (PDA) detection at 220 nm. The linearity of the method was excellent over the range 1–32 μg mL?1. The method was sensitive, with low limits of detection (20 ng mL?1) and quantification (100 ng mL?1). The recovery of the method was consistently good (98.7–100.9%), with low (<1%) intra-day and inter-day relative standard deviation. Robustness studies confirmed that peak area was unaffected by small changes in temperature, and mobile phase composition and flow rate. Both alkaline and acidic hydrolytic degradation were performed in methanolic solution. In alkaline medium the drug was degraded immediately; it was degraded within 90 min in acidic medium. The validated, stability-indicating, method was used for analysis of racecadotril in pharmaceutical dosage form and also to reveal the hydrolytic degradation profile of the racecadotril.  相似文献   

9.
A high-performance liquid chromatography-diode array detector (HPLC-DAD) method was developed and validated for the quantitation of dexibuprofen in dexibuprofen tablets using ovomucoid chiral stationary phase (Ultron ES-OVM). The mobile phasewas composed of 0.025 M potassium phosphate dibasic (pH 4.5)-methanol-ethanol (85:10:5 v/v/v). The method was validated for specificity, linearity, range, accuracy, precision and robustness. The method was enantiomerspecific for the determination of dexibuprofen [S-(+)-isomer ibuprofen] in the presence of R-(-)-isomer ibuprofen in bulk drug, pharmaceutical dosage form and under stress degradation. The method was linear over the range 15-35 mg/mL with r2 = 0.9995; accuracy and precision were acceptable with %RSD < 2.0%. The method was found to be specific, precise, accurate, robust and stability-indicating, and can be successfully applied for the routine analysis of dexibuprofen in bulk drug and pharmaceutical dosage form.  相似文献   

10.
A validated, specific, stability-indicating reversed-phase liquid chromatographic method has been developed for quantitative analysis of gatifloxacin, its degradation products, and its process-related impurities in bulk samples and in pharmaceutical dosage forms. Forced degradation of gatifloxacin bulk sample was conducted in accordance with ICH guidelines. Acidic, basic, neutral, and oxidative hydrolysis, thermal stress, and photolytic degradation were used to assess the stability-indicating power of the method. Substantial degradation was observed during oxidative hydrolysis. No degradation was observed under the other stress conditions. The method was optimized using samples generated by forced degradation and sample solution spiked with impurities. Good resolution of the analyte peak from peaks corresponding to process-related impurities and degradation products was achieved on a C18 column by use of a simple linear mobile-phase gradient prepared from mixtures of acetonitrile and an aqueous solution of sodium dihydrogen orthophosphate dihydrate and triethylamine adjusted to pH 6.5 with orthophosphoric acid. Detection was performed at 240 nm. Limits of detection and quantification were established for gatifloxacin and its process-related impurities. When the stressed test solutions were assayed by comparison with gatifloxacin working standard the mass balance was always close to 99.3%, indicating the method was stability-indicating. Validation of the method was performed in accordance with ICH requirements. The method was found to be suitable for checking the quality of bulk samples of gatifloxacin at the time of batch release and also during storage.  相似文献   

11.
Aksoy  B.  K&#;&#;&#;kg&#;zel  &#;.  Rollas  S. 《Chromatographia》2007,66(1):57-63

The objective of the current study was the development and subsequent validation of a simple, sensitive, precise and stability-indicating reversed-phase HPLC method for the determination of ciprofloxacin HCl in pharmaceutical dosage forms in the presence of its potential impurities. The chromatographic separation of ciprofloxacin HCl and its related compounds was achieved on an Inertsil ODS3 column using UV detection. The optimized mobile phase consisted of phosphoric acid solution: acetonitril. The proposed method provided linear responses within the concentration range 250–750 μg mL−1 for ciprofloxacin HCl and 0.5–1.5 μg mL−1 for its related compounds. LOD and LOQ values for the active substance were 5.159 and 15.632 μg mL−1, respectively. Correlation coefficients (r) of the regression equations for the impurities were greater than 0.99 in all cases. The precision of the method was demonstrated using intra- and inter-day assay RSD% values which were less than 1% in all instances. No interference from any components of pharmaceutical dosage forms or degradation products was observed.

  相似文献   

12.
A stability-indicating HPLC assay method was developed for the quantitative determination of tadalafil in bulk samples and in pharmaceutical dosage forms in the presence of the degradation products. It involved a 250 mm × 4.6 mm, 5 μm C-18 column. The gradient LC method employs solution A and B as mobile phase. Solution A contains a mixture of buffer (phosphate buffer and tetra-n-butyl ammonium hydrogen sulfate) pH 2.5: acetonitrile (80:20, v/v) and solution B contains a mixture of water: acetonitrile (20:80, v/v). The flow rate was 1.0 mL min−1 and the detection wavelength was 220 nm. The retention time of tadalafil is about 17 min. Tadalafil was subjected to different ICH prescribed stress conditions. Degradation was found to occur in hydrolytic and to some extent in oxidative stress conditions, while the drug was stable to photolytic and thermal stress. The drug was particularly labile under alkaline hydrolytic conditions. The drug was subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. The assay of stress samples was calculated against a qualified reference standard and the mass balance was close to 99.5%. The developed RP-LC method was validated with respect to linearity, accuracy, precision and ruggedness.  相似文献   

13.
A simple, rapid, isocratic, stability-indicating reverse phase ultra-performance liquid chromatographic (RP-UPLC) method was developed and validated for the routine analysis of moxonidine in the presence of its degradation products in active pharmaceutical ingredient and pharmaceutical dosage forms. Forced degradation studies were performed according to the guidance of International Conference for Harmonization and were used to evaluate moxonidine intrinsic stability. The drug was subjected to acid, neutral and base hydrolysis as well as to oxidative, thermal and photolytic decomposition in both solution and solid state. The drug appeared to be unstable towards acid and base hydrolysis. To achieve desirable conditions for UPLC analysis, the method development was done with the assistance of experimental design and multivariate optimization methodology by means of Derringer’s desirability function. Stress samples were analyzed according to the experimental plan for fractional factorial screening design and Box-Behnken optimization design. The chromatographic separation was achieved on a C18 Hypersil Gold aq. column (100 mm × 2.1 mm, 1.9 μm) with the mobile phase consisting of methanol–ammonium acetate buffer (10 mM, pH 3.43) mixture (0.9:99.1, v/v) pumped at a flow rate of 870 μL min?1 and detection wavelength of 255 nm. The UPLC–MS and UPLC–MS/MS analyses were further used to characterize the found degradation products. The validation of the proposed method was also performed considering selectivity, linearity, accuracy, precision, limit of detection and limit of quantification, and the results indicated that the method fulfilled all required criteria. The method was successfully applied to the analysis of commercial tablets.  相似文献   

14.

A reversed-phase liquid chromatography (RP-LC) method was validated for the determination of rupatadine in pharmaceutical dosage forms. The LC method was carried out on a Gemini C18 column (150 mm × 4.6 mm I.D.), maintained at 30 °C. The mobile phase consisted of ammonium acetate buffer (pH 3.0; 0.01 M) with 0.05% of 1-heptanesulfonic acid–acetonitrile (71.5:28.5, v/v), run at a flow rate of 1.0 mL min−1 and using photodiode array (PDA) detection at 242 nm. The chromatographic separation was obtained with retention time of 5.15 min, and was linear in the range of 0.5–400 μg mL−1 (r = 0.9999). The specificity and stability-indicating capability of the method was proven through the degradation studies and showing also, that there was no interference of the excipients. The accuracy was 100.39% with bias lower than 0.58%. The limits of detection and quantitation were 0.01 and 0.5 μg mL−1, respectively. Moreover, method validation demonstrated acceptable results for precision, sensitivity and robustness. The proposed method was applied for the analysis of pharmaceutical dosage forms assuring the therapeutic efficacy.

  相似文献   

15.
A stability-indicating liquid chromatographic method was developed and validated for quantitative determination of olmesartan medoxomil (OLM) in coated tablets in the presence of degradation products generated under stress conditions. An isocratic LC separation was performed using a Phenomenex RP-18 column using a mobile phase consisting of water:triethylamine:acetonitrile (60:0.3:40 v/v/v, pH adjusted to 6.3 with phosphoric acid). The flow rate was 1.2 mL min?1 and the detection was achieved with a photodiode array detector set at 257 nm. The response was linear over a range of 10.0 to 30.0 μg mL?1 (r = 0.9999). The specificity and stability-indicating capability of the method was verified subjecting the reference substance and drug product to hydrolytic, oxidative, photolytic, and thermal stress conditions. The method showed a good and consistent recovery (100.2%) with low intra- and inter-day relative standard deviation (RSD) (≤1.0%). A considerable degradation occurred in all stress conditions and the degradation product was well resolved from the main peak. There was no interference of the excipients in the determination of the active pharmaceutical ingredient. Thus, the proposed method was found to be stability-indicating and can be used for routine analysis for quantitative determination of OLM in coated tablets without the interference of major degradation products.  相似文献   

16.

A simple, selective, precise, rapid and accurate stability-indicating high-performance thin-layer chromatography (HPTLC) method was developed and validated for the estimation of dapagliflozin and metformin in tablet dosage form. In this work, methanol–ethyl acetate–ammonium acetate (6:4:0.1, V/V) as the mobile phase and aluminum-backed TLC plates pre-coated with 250 µm layer of silica gel 60F254 as the stationary phase were used for the estimation of dapagliflozin and metformin. The wavelength selected for detection was 220 nm. The linearity range was found to be 20–100 ng/spot (r2 = 0.9985) for dapagliflozin and 500–2500 ng/spot (r2 = 0.9984) for metformin. Validation of the developed method was performed as per the International Council for Harmonisation (ICH) guidelines. Stress testing of dapagliflozin and metformin was performed under acidic, alkaline, oxidative, photolytic and dry-heat degradation conditions. The chromatographic conditions successfully resolved dapagliflozin and metformin from their degradation products, formed under various stress conditions. From stress testing, dapagliflozin was found to be significantly degrading under acidic, alkaline, oxidative, photolytic and dry-heat degradation conditions, while metformin was found to be significantly degrading in acidic and alkaline degradation conditions and stable under oxidative, photolytic and dry-heat degradation conditions. Tablet dosage form of dapagliflozin and metformin was analyzed by the developed method.

  相似文献   

17.
Simvastatin and ezetimibe are used to treat hyperlipidemia. A simple, selective and stability-indicating HPTLC method has been established for analysis of simvastatin and ezetimibe. The method has been validated so that both drugs can routinely be analyzed simultaneously. The method uses aluminum-backed silica gel 60F254 TLC plates as stationary phase with n-hexane–acetone 6:4 (v/v) as mobile phase. Densitometric analysis of both drugs was carried out in absorbance mode at 234 nm. This system was found to give compact bands for simvastatin and ezetimibe (R F 0.39 ± 0.05 and 0.50 ± 0.05, respectively). Linear relationships were obtained between response and amount of drug in the range 200–1,600 ng per band with high correlation coefficients (r 2 = 0.9917 ± 0.0018 for simvastatin and r 2 = 0.9927 ± 0.0021 for ezetimibe). The method was validated for precision, robustness, and recovery. The limits of detection and quantitation were 25 and 150 ng per band, respectively. Simvastatin and ezetimibe were subjected degradation by acid, pH 6.8 phosphate buffer, oxidation, dry heat, and wet heat. The degradation products were well resolved from the pure drug with significantly different R F values. Because the method could effectively separate the drug from its degradation products, it can be used for stability-indicating analysis.  相似文献   

18.
A simple, precise, and rapid stability-indicating reversed-phase-HPLC method was developed and validated for the estimation of metformin (MET), dapagliflozin (DAP), and saxagliptin (SAX) combination in bulk and tablet dosage forms. The proposed method uses a Kromasil C18 column (150 × 4.6 mm, 5 μm) with column oven temperature of 30°C and mobile phase containing a mixture of 60% phosphate buffer (pH = 3) and 40% acetonitrile. The flow rate was set at 1.0 mL/min, and the injection volume was 10 μL. The detection was carried out at 230 nm using a photodiode array detector, and the total run time was 4 min. The proposed method was validated according to International Council for Harmonisation (ICH) guidelines for specificity, linearity, precision, accuracy, robustness, and solution stability. The method is linear over the range of 125–750 μg/mL for MET, 1.25–7.5 μg/mL for DAP, and 0.625–3.75 μg/mL for SAX. The observed correlation coefficients (R2) for MET, DAP, and SAX are >0.999. The proposed method is precise, and the percentage relative standard deviation was found to be between 0.4 and 0.8. The observed percentage recoveries were between 98.51 and 100.80 for all three compounds. The product was subjected to stress conditions of acid, base, oxidative, thermal, and photolytic degradation. The product was found to degrade significantly in oxidative, acid, and base hydrolysis degradation conditions, and the degradation products were well determined from the active peaks, thus proving the stability-indicating power of the method. The developed and validated stability-indicating reversed-phase-HPLC method was appropriate for quantitative determination of these drugs in pharmaceutical preparations and also for quality control in bulk manufacturing.  相似文献   

19.
Three stability-indicating assay methods were developed for the determination of tropisetron in a pharmaceutical dosage form in the presence of its degradation products. The proposed techniques are HPLC, TLC, and first-derivative spectrophotometry (1D). Acid degradation was carried out, and the degradation products were separated by TLC and identified by IR, NMR, and MS techniques. The HPLC method was based on determination of tropisetron in the presence of its acid-induced degradation product on an RP Nucleosil C18 column using methanol-water-acetonitrile-trimethylamine (65 + 20 + 15 + 0.2, v/v/v/v) mobile phase and UV detection at 285 nm. The TLC method was based on the separation of tropisetron and its acid-induced degradation products, followed by densitometric measurement of the intact spot at 285 nm. The separation was carried out on silica gel 60 F254 aluminum sheets using methanol-glacial acetic acid (22 + 3, v/v) mobile phase. The 1D method was based on the measurement of first-derivative amplitudes of tropisetron in H2O at the zero-crossing point of its acid-induced degradation product at 271.9 nm. Linearity, accuracy, and precision were found to be acceptable over concentration ranges of 40-240 microg/mL, 1-10 microg/spot, and 6-36 micro/mL for the HPLC, TLC, and 1D methods, respectively. The suggested methods were successfully applied for the determination of the drug in bulk powder, laboratory-prepared mixtures, and a commercial sample.  相似文献   

20.
A novel, sensitive, stability-indicating gradient RP-LC method has been developed for quantitative analysis of balsalazide disodium and its related impurities both in the bulk drug and in pharmaceutical dosage forms. Efficient chromatographic separation was achieved on a C18 stationary phase with a simple mobile-phase gradient prepared from methanol and phosphate buffer (10 mm potassium dihydrogen orthophosphate monohydrate, adjusted to pH 2.5 by addition of orthophosphoric acid). The mobile-phase flow rate was 1.0 mL min?1. Quantification was achieved by use of ultraviolet detection at 240 nm. Under these conditions resolution of balsalazide disodium from its three potential impurities was greater than 2.0. Regression analysis resulted in a correlation coefficient greater than 0.99 for balsalazide disodium and all three impurities. This method was capable of detecting the three impurities at 0.003% of the test concentration of 0.3 mg mL?1, using an injection volume of 10 μL. Inter-day and intra-day precision for all three impurities and for balsalazide disodium was within 2.0% RSD. Recovery of balsalazide disodium from the bulk drug (99.2–101.5%) and from pharmaceutical dosage forms (99.8–101.3%), and recovery of the three impurities (99.1–102.1%) was consistently good. The test solution was found to be stable in 70:30 (v/v) methanol–water for 48 h. When the drug was subjected to hydrolytic, oxidative, photolytic, and thermal stress, acidic and alkaline hydrolysis and oxidizing conditions led to substantial degradation. The RP-LC method was validated for linearity, accuracy, precision, and robustness.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号