1.
McWhorter S  Soper SA 《Electrophoresis》2000,21(7):1267-1280
As capillary electrophoresis continues to focus on miniaturization, either through reducing column dimensions or situating entire electrophoresis systems on planar chips, advances in detection become necessary to meet the challenges posed by these electrophoresis platforms. The challenges result from the fact that miniaturization requires smaller load volumes, demanding highly sensitive detection. In addition, many times multiple targets must be analyzed simultaneously (multiplexed applications), further complicating detection. Near-infrared (NIR) fluorescence offers an attractive alternative to visible fluorescence for critical applications in capillary electrophoresis due to the impressive limits of detection that can be generated, in part resulting from the low background levels that are observed in the NIR. Advances in instrumentation and fluorogenic labels appropriate for NIR monitoring have led to a growing number of examples of the use of NIR fluorescence in capillary electrophoresis. In this review, we will cover instrumental components used to construct ultrasensitive NIR fluorescence detectors, including light sources and photon transducers. In addition, we will discuss various types of labeling dyes appropriate for NIR fluorescence and finally, we will present several applications that have used NIR fluorescence in capillary electrophoresis, especially for DNA sequencing and fragment analysis.  相似文献   

2.
We prepared a series of low-molecular-mass fluorescent ampholytes with narrow pI range. These fluorescein-based ampholytes are detection compatible with argon laser-induced fluorescence (LIF) detection. The selected properties, important for their routine use as fluorescent pI markers, were examined. The pI values of new fluorescein-based pI markers were determined by capillary isoelectric focusing (CIEF) using currently available low-molecular-mass pI markers for CIEF with photometric detection. The examples of CIEF with fluorometric detection of new compounds together with fluorescein isothiocyanate (FITC) derivatized proteins are presented.  相似文献   

3.
Chan KC  Muschik GM  Issaq HJ 《Electrophoresis》2000,21(10):2062-2066
Two solid-state UV lasers were applied to the laser-induced fluorescence (LIF) detection of various groups of compounds after separation by capillary electrophoresis. These lasers are thermoelectric-cooled, highly compact, and inexpensive. Such lasers provide few mW of quasi-continuous wave (CW) power which are sufficient and stable for LIF detection. Native fluorescence detection of tryptophan-containing proteins and peptides and related indoles was achieved at the nM level with the laser operating at 266 nm. Detection of fluorescamine-labeled amino acids and peptides was also possible at the nM level with the laser operating at 355 nm. Amino acids at a concentration as low as 10 ng/mL could be labeled with fluorescamine. Solid-state UV-LIF detection of the tryptic digest of cytochrome c after fluorescamine derivatization was demonstrated.  相似文献   

4.
In this study, we developed a novel assay that simultaneously detects multiple miRNAs (microRNAs) within a single capillary by combining a tandem adenosine-tailed DNA bridge-assisted splinted ligation with denaturing capillary gel electrophoresis with laser-induced fluorescence. This proposed method not only represents a significant improvement in resolution but also allows for the detection of multiple miRNAs within a single capillary based on the length differences of specified target bridge DNA. The assay's linear range covers three orders of magnitude (1.0 nM to 1.0 pM) with a limit of detection (S/N=3) as low as 190 fM (2.5 zmol). Five miRNAs of Epstein-Barr virus (EBV) were also detected in EBV-infected nasopharyngeal carcinoma cells, while they did not appear in non-virus infected cells. Moreover, the electropherogram indicated that the screening of isomiRs (isomer of miRNA) of BART2 by CE-LIF is feasible by our proposed method. The developed electrophoresis-based method for miRNA detection is fast, amplification-free, multiplexed and cost-effective, making it potentially applicable to large-scale screening of isomiRs.  相似文献   

5.
A wall-free detection method based on liquid junction in a capillary gap was proposed for laser-induced fluorescence (LIF) of capillary electrophoresis (CE). The capillary gap of the wall-free cell was fabricated by etching a 10-mm × 50-μm I.D. fused-silica capillary to obtain a polyimide coating sleeve, decoating about 6 mm at one end of both 50 μm I.D. separation and liquid junction capillary, inserting the treated capillary ends into the coating sleeve oppositely, fixing the capillaries with a gap distance of 140 μm by epoxy glue and removing the coating sleeve by burning. The theoretical model, experimental results and wall-free cell images indicated that the gap distance and applied voltage were main influence factors on the wall-free detection. Since the wall-free cell increased the absorption light path and avoided the stray light from the capillary wall, it improved the ratio of signal to noise and limit of detection (LOD) of CE-LIF. Three flavin compounds of riboflavin (RF), flavin mononucleotide sodium (FMN) and flavin adenine dinucleotide disodium (FAD) were used to evaluate the wall-free detection method. Compared with on-column cell, the LODs of the wall-free cell were improved 15-, 6- and 9-fold for RF, FMN and FAD, respectively. The linear calibration concentrations of the flavins ranged from 0.005 to 5.0 μmol/L. The column efficiency was in the range from 1.0 × 105 to 2.5 × 105 plates. The wall-free detection of CE-LIF was applied to the analysis of the flavins in spinach and lettuce leaves.  相似文献   

6.
Lam MT  Le Chris X 《The Analyst》2002,127(12):1633-1637
A competitive immunoassay using capillary electrophoresis with laser-induced fluorescence was developed for vancomycin. Capillary electrophoresis using a Tris-glycine running buffer provided adequate separation of the antibody-bound from the unbound fluorescent probe (tracer) in less than 4 min. Laser-induced fluorescence polarization (LIFP) provided high sensitivity detection and simultaneous monitoring of fluorescence intensity and polarization. A fluorescence polarization value of 0.30 confirmed the formation of the antibody-tracer complex. Calibration curves showed a working linear range of 2-3 orders of magnitude with a minimum detectable concentration of 0.98 ng mL(-1) (or 1.1 fg vancomycin). Clinical samples obtained from patients undergoing vancomycin treatment were analyzed for vancomycin and the results correlated well with a standard immunoassay based on latex particle detection that was routinely used by a hospital laboratory. Only 1/10 of the reagents were needed as compared with the standard immunoassay.  相似文献   

7.
A new analytical method for baclofen (4-amino-3-p-chlorophenylbutyric acid) based on capillary electrophoretic separation and laser-induced fluorescence detection has been developed. Naphthalene-2,3-dicarboxaldehyde was used for precolumn derivatization of the non-fluorescent drug. Optimal separation and detection were obtained with an electrophoretic buffer of 50 mM sodium borate (pH 9.5) and a He-Cd laser (excitation at 442 nm, emission at 500 nm). Linearity (r > or = 0.99) over three orders of magnitude was generally obtained and the concentration limit of detection was in the nanomolar level. Coupled with a simple cleanup procedure, the method was successfully applied to the analysis of baclofen in human plasma. Recovery of spiked baclofen in plasma was 98%. The relative standard deviation values on peak size and migration time were 7.9% and 0.4%, respectively. The limit of detection of baclofen in plasma was 10 ng/ml.  相似文献   

8.
Phycobiliproteins are derived from the photosynthetic apparatus of cyanobacteria and eukaryotic algae. They are composed of a protein backbone to which linear tetrapyrrole chromophores are covalently bound. Furthermore, they are water-soluble highly fluorescent, and relatively stable at room temperature and neutral pH. For this reason, capillary electrophoresis-laser induced fluorescence (CE-LIF) seems the idea method for determination of these important proteins. The effects of buffer additives such as sodium dodecyl sulfate (SDS)and putrescine on the separation of the three major phycobiliprotein types, namely allophycocyanin, phycocyanin, and phycoerythrin, with excitation and emission maxima at 652/660, 615/647, and 565(494)/575 nm, respectively, are considered. Detection limits for these proteins by CE-LIF are some 60-500 times better than by absorbance detection. The development of a fast and sensitive CE-LIF assay such as this is of potential significance to our understand ing of chemical and biological oceanographic processes.  相似文献   

9.
The industrial application of nitrocellulose depends on its nitrogen content. When nitrocellulose presents high nitrogen content is used in the manufacture of explosives whereas nitrocellulose with low nitrogen content is used to make a wide range of daily and non-explosive products (e.g. cigarettes, paints, lacquers). This fact makes really important to develop a method for the determination and discrimination of nitrocellulose samples. This work reports, for the first time, the qualitative determination of nitrocellulose previously derivatized with 8-aminopyrene-1,3,6-trisulfonic acid (APTS) by capillary electrophoresis (CE-LIF) with laser-induced fluorescence detection (CE-LIF). APTS-labeled nitrocellulose was determined in lowly and highly nitrated nitrocellulose samples present in collodions and smokeless gunpowders, respectively, after their pulverization in liquid nitrogen. The method described enables the visual discrimination of different nitrocelluloses on the basis of the different electrophoretic profiles obtained, and provides a useful tool to determine nitrocellulose. Additionally, the use of field-amplified sample injection (FASI) enabled enhanced sample detection, which made it possible to determine nitrocellulose contained in ∼15 μg of gunpowder.  相似文献   

10.
毛细管电泳-激光诱导荧光检测法测定抗癫痫药加巴喷丁   总被引:1,自引:0,他引:1  
蔡元丽  杨甲甲  王宇飞  白珂珂  李晖 《色谱》2010,28(12):1179-1184
建立了毛细管电泳-激光诱导荧光(CE-LIF)测定抗癫痫药加巴喷丁的方法。加巴喷丁经4-氯-7-硝基苯并-2-氧杂-1,3-二唑(NBD-Cl)衍生化后,采用10 mmol/L硼砂-10 mmol/L十二烷基硫酸钠(pH 9.75)的缓冲体系,加巴喷丁在6 min内实现高效基线分离。方法的线性范围为0.01~10 mg/L(r=0.9997),检出限为2 μg/L,定量限为10 μg/L。方法的平均回收率为100.2%~103.1%,相对标准偏差为0.15%~1.00%(n=3)。该方法灵敏、快速、准确和可靠,已用于加巴喷丁药物制剂的质量控制。  相似文献   

11.
A novel method is presented to detect DNA fragments separated by capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection using inverse-flow derivatization. In electrophoresis, the intercalating dye, thiazol orange was only added to the separation buffer at the positive polarity. The negatively charged DNA fragments migrated from the negative polarity to the positive polarity, while the positively charged dye migrated in the opposite direction. When DNA fragments met with dye ions, the DNA–dye complexes were formed. The complexes continued migrating to the positive end, due to their net negative charges. When the complexes passed through the detection window, the fluorescent signals were generated. Importantly, DNA fragments migrated as their native state before DNA–dye complexes were formed. This procedure was used to detect double stranded DNA (dsDNA) and single stranded DNA (ssDNA) fragments, and polymerase chain reaction (PCR) products. The excellent resolution and good reproducibility of DNA fragments were achieved in non-gel sieving medium. This procedure may be useful in genetic mutation/polymorphism detections.  相似文献   

12.
Limited by the lack of a sensitive, universal detector, many capillary-based liquid-phase separation techniques might benefit from techniques that overcome modest concentration sensitivity by preconcentrating large injection volumes. The work presented employs selective solid-phase extraction by immunoaffinity capillary electrochromatography (IACEC) to enhance detection limits. A model analyte, fluorescein isothiocyanate (FITC) biotin, is electrokinetically applied to a capillary column packed with an immobilized anti-biotin-IgG support. After selective extraction by the immunoaffinity capillary, the bound analyte is eluted, migrates by capillary zone electrophoresis (CZE), and is detected by laser-induced fluorescence. The column is regenerated and reused many times. We evaluate the performance of IACEC for selective trace enrichment of analytes prior to CZE. The calibration curve for FITC-biotin bound versus application time is linear from 10 to 300 seconds. Recovery of FITC-biotin spiked into a diluted urinary metabolites solution was 89.4% versus spiked buffer, with a precision of 1.8% relative standard deviation (RSD).  相似文献   

13.
A competitive immunoassay based on capillary electrophoresis (CE) with laser-induced fluorescence (LIF) has been developed for the determination of recombinant hirudin (r-hirudin) in biological mixtures. Hirudin, a thrombin inhibitor, is a polypeptide of 65 amino acids. To check purity levels and perform pharmacokinetic studies of (r-hirudin), specific and reproducible analysis methods are demanded. The work involved the development of separation conditions allowing for routine analysis of plasma samples. In this study, r-hirudin was labeled with fluorescein isothiocyanate (FITC), and FITC-labeled r-hirudin was purified using high-performance liquid chromatography. The purified product was then mixed with the sample followed with the addition of anti-hirudin antibody. Free, antibody-bound, and tagged r-hirudin could be separated within 5 min by CE analysis using uncoated fused-silica capillary with high reproducibility. The developed method can be used to determine r-hirudin with good precision and a detection limit lower than 20 nM. This result demonstrates the feasibility of the CE-LIF immunoassay method for the determination of r-hirudin in plasma samples.  相似文献   

14.
Su P  Zhang XX  Chang WB 《Electrophoresis》2003,24(18):3197-3201
An immunoassay for estrone (E(1)) in women's serum, based on the competitive reaction between fluorescein-labeled complete antigen and E(1) with limited amount of anti-estrone monoclonal antibody is described. A thermally reversible hydrogel, poly-N-isopropylacrylamide (pNIPA), was added to the buffer to improve the reproducibility. With a laser-induced fluorescence (LIF) detector, the capillary electrophoretic immunoassay (CEIA) can be applied to determine E(1) at a concentration lower than 19.6 pg/mL. The E(1) levels in ten normal women's serum were measured at the range of 118.6-222.0 pg/mL.  相似文献   

15.
Liu X  Ma L  Lin YW  Lu YT 《Journal of chromatography. A》2003,1021(1-2):209-213
A novel method based on capillary electrophoresis coupled to laser-induced fluorescence detection (CE-LIF) was developed for the determination of abscisic acid (ABA), which is an essential phytohormone during plant growth and development. ABA was labeled with 8-aminopyrene-1,3,6-trisulfonate via reductive amination in presence of acetic acid and sodium cyanoborohydride. The derivatization yield was maximized by optimizing several derivatization parameters including derivatization reagent concentration, reaction temperature and time. The conjugate was separated and quantitated by CE-LIF. The linearity of ABA was determined in the range from 0.1 to 10 micromol l(-1) with a correlation of 0.9979. The derivatization limit of detection for ABA was found to be 56 fmol (corresponding to the concentration of 2.8 x 10(-8) mol l(-1)). The detection limit for ABA was 5.5 amol for an injection volume of 5 nl. As a preliminary application, the proposed method was successfully applied to determining trace amount of ABA in the crude extracts of tobacco without extra purification and enrichment procedure and showed a better selectivity and sensitivity than those conventional methods used in determination of ABA.  相似文献   

16.
Yu L  Li SF 《Electrophoresis》2005,26(22):4360-4367
There is a need to develop simple yet effective preconcentration methods to enhance concentration sensitivity for CE analysis of trace level analytes in real samples, particularly when commonly available but less sensitive detection methods, e.g., UV detection, are used. In this report, a hyphenated online preconcentration strategy combining dynamic pH junction with sweeping (i.e., dynamic pH junction-sweeping) was employed for the analysis of four toxic pyrrolizidine alkaloids (PAs) of senkirkine, senecionine, retrorsine, and seneciphylline in Chinese herbal medicine (Kuan donghua). Direct electrokinetically focusing of a large sample volume injection (up to 20% of capillary length) on the capillary was performed using the dynamic pH junction-sweeping method. A sample matrix consisting of 10 mM phosphate with 20% methanol at pH 4.0 and a BGE containing 20 mM borate, 30 mM SDS, and 20% methanol at pH 9.1 were utilized to realize dynamic pH junction-sweeping for PAs. This online preconcentration strategy resulted in sensitivity enhancement factors ranging from 23.8- to 90.0-fold for the four toxic PAs, giving an LOD as low as 30 ppb for the PAs. Critical factors such as sample matrix type, pH, and salt concentration were also examined to achieve higher sensitivity enhancement, shorter analysis time, and better resolution. The results indicate that the proposed dynamic pH junction-sweeping technique is a powerful alternative approach for identification and determination of trace levels of these toxic PAs and other hydrophobic, protonatable compounds in real samples.  相似文献   

17.
Hirudin, a thrombin inhibitor, is a polypeptide of 65 amino acids. To check purity levels and perform pharmacokinetic studies of recombinant hirudin (r-hirudin), a specific and reproducible analysis method is required. Capillary electrophoresis (CE) is rapidly becoming an important procedure for the analysis of biological molecules. Recently, CE combined with immunoassay has emerged as a new analytical technique. CE-based immunoassay (CEIA) is a sensitive and specific method combining laser-induced fluorescence (LIF) and immunoassay. Therefore, in this study, we specifically investigated fluorescence labeling and determination of r-hirudin by CEIA with a LIF detector using labeled r-hirudin and polyclonal antibody. r-Hirudin was labeled with fluorescein isothiocyanate (FITC). FITC-labeled r-hirudin was purified using high-performance liquid chromatography (HPLC). The method is based on preincubation of r-hirudin and antibody for 20 min, followed by CE analysis using an uncoated capillary. Free and bound r-hirudin were separated within 5 min using CE with high reproducibility. This study demonstrated that the CEIA method could be applied to quantitative analysis of r-hirudin in biological fluids.  相似文献   

18.
Ellipticine (5,11-dimethyl-6H-pyrido[4,3-b]carbazole), an alkaloid isolated from Apocynaceae plants, exhibits an antitumor activity, which is exceptionally high against several specific types of tumors. Ellipticine is also interesting as an anticancer drug as it has limited side effects and lacks of hematological toxicity. Various methods to study intercalating activity of this drug have been developed. However, to our best knowledge, capillary electrophoresis (CE) as a technique combining high separation resolution with various detection options has never been used for these purposes. In this study, a novel separation method based on CE with laser-induced fluorescence (CE-LIF) detection has been developed for the determination of ellipticine and for the monitoring of ellipticine-DNA interaction. Sodium acetate (50 mM, pH 4.5) was used as a background electrolyte and LIF detection at λ(ex) = 488 nm. The limit of detection for ellipticine was determined to be 5 × 10?? M. A total of 20% dimethyl sulfoxide was found optimal as sample solvent. Additionally, intercalation of ellipticine into the double-stranded DNA was investigated. Signal corresponding to ellipticine was decreasing and a new peak appeared and was growing. It can be concluded that CE-LIF is a method applicable to in vitro studies of ellipticine-DNA complexes.  相似文献   

19.
Yu CZ  He YZ  Han F  Fu GN 《Journal of chromatography. A》2007,1171(1-2):133-139
A post-column reactor with coaxial-gap mode is developed for laser-induced fluorescence detection (LIF) in capillary electrophoresis (CE). The reactor can be assembled simply and conveniently, in which a thin polyimide sleeve of 10-mm length obtained from the capillary coating is used to align separation and reaction capillary with a 20 microm gap. Naphthalene-2,3-dicarboxaldehyde and 2-mercaptoethanol are used as derivatization reagents and delivered into the reaction capillary through the annulus between the separation capillary and polyimide sleeve and the gap of two capillaries by gravity. A reaction distance from the gap to detection point is 5mm. For the post-column reactor of CE-LIF, several configuration parameters are optimized, including liquid level difference between the derivatization solution and outlet buffer, annular dimension between the outer diameter of etched separation capillary and the inner diameter of polyimide sleeve, and reaction distance, etc. The detection limits in the range from 8.0x10(-8) to 1.0x10(-6) mol/L and linear calibration range more than two orders of magnitude are obtained for amino acids. The separation efficiency ranges from 1.35x10(5) to 1.67x10(5) theoretical plates.  相似文献   

20.
A method based on the presence of a dynamic pH junction within the capillary to induce band narrowing for enhanced detection sensitivity for some peptides is presented. This technique is predicated on a sharp reduction in an analyte's migration velocity following a reversal of its electrophoretic direction from the acidic sample zone to the basic BGS zone. Larger-than-usual injection volumes of samples in relatively high-conductivity matrices were enabled, without degrading peak shape, resolution and efficiency. The size of the original sample plug was reduced by as much as 38-fold, and improvement in detector response in terms of peak height by as much as 124-fold was obtained. The effects of pH and concentration of the sample matrix, and the length of sample injection on the efficiency of the technique are discussed.  相似文献   