首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Phthaloylchitosan (PHCS) has been synthesized by a simple and low-cost method using chitosan and phthalic anhydride as organic precursors by microwave irradiation. Techniques of nuclear magnetic resonance (NMR), FT-IR spectroscopy and transmission electron microscope (TEM) were used to characterize the structure and properties of the Phthaloylchitosan. Moreover, glassy carbon electrode modified with Phthaloylchitosan and carbon nanotube (PHCS–CNT/GCE) was prepared by casting of the PHCS–CNT solution on GCE. The electrochemical behavior of PHCS–CNT/GCE was investigated and compared with the electrochemical behavior of Phthaloylchitosan modified GC (PHCS/GC), carbon nanotube modified GC (CNT/GC) and unmodified GC using cyclic voltammetry (CV). The Phthaloylchitosan film is electrochemically inactive; similar background charging currents are observed at bare GC. Electrochemical parameters, including apparent diffusion coefficient for the Fe(CN)63-/4- redox probe at PHCS–CNT/GCE is comparable to values reported for GCE, CNT/GCE and PHCS/GCE. The PHCS–CNT/GCE sensor responded linearly to tyrosine (Tyr) in the concentration of 1.0 × 10–6 to 8.0 × 10–4 M with detection limit of 3.0 × 10–7 M at 3σ using amperometry. In addition, the PHCS–CNT/GCE displayed good reproducibility, high sensitivity and good selectivity towards the determination of Tyr, making it suitable for the determination of Tyr in clinical and medicine.  相似文献   

2.
Hwang GH  Han WK  Park JS  Kang SG 《Talanta》2008,76(2):301-308
A bismuth-modified carbon nanotube electrode (Bi-CNT electrode) was employed for the determination of trace lead, cadmium and zinc. Bismuth film was prepared by in situ plating of bismuth onto the screen-printed CNT electrode. Operational parameters such as preconcentration potential, bismuth concentration, preconcentration time and rotation speed during preconcentration were optimized for the purpose of determining trace metals in 0.1M acetate buffer solution (pH 4.5). The simultaneous determination of lead, cadmium and zinc was performed by square wave anodic stripping voltammetry. The Bi-CNT electrode presented well-defined, reproducible and sharp stripping signals. The peak current response increased linearly with the metal concentration in a range of 2-100 microg/L. The limit of detection was 1.3 microg/L for lead, 0.7 microg/L for cadmium and 12 microg/L for zinc (S/N=3). The Bi-CNT electrode was successfully applicable to analysis of trace metals in real environments.  相似文献   

3.
A simply prepared DNA immobilized on a carbon nanotube paste electrode (CNTPE) was utilized to monitor dopamine ion concentration using the cyclic voltammetry (CV) and square-wave (SW) stripping voltammetry methods. The optimum analytical conditions were sought. The result obtained was a very low detection limit compared to other common voltammetry methods. The optimal parameters were found to be as follows: 3.5 pH, 0.48 V SW amplitude, 71 Hz frequency, 5 s accumulation time, 0.01 V increment potential, and -1.3 V (anodic-*-) and 1.2 V (cathodic-o-) accumulation potentials. Given these conditions, the linear working range was observed to be within 0.01-0.11 microg L(-1) (SW anodic and CV). The analytical detection limit was determined to be SW anodic and CV: 4.0 microg L(-1) (2.1 x 10(-11) mol L(-1)) dopamin, and the relative standard deviation at the dopamine concentration of SW anodic 0.05 microg L(-1) was 0.02% (n=15) at the optimum conditions.  相似文献   

4.
Lu TH  Sun IW 《Talanta》2000,53(2):443-451
A nafion film coated glassy carbon electrode (NFGCE) was employed for the determination of paraquat. Paraquat was accumulated onto NFGCE by the cation-exchange feature of nafion at open circuit potential in basic medium followed by cathodic differential pulse voltammetric (CDPV) determination in a medium containing permanganate ions. The sensitivity for the determination of paraquat was improved through the electrocatalytic reduction of permanganate by the reduced paraquat. With 3-min accumulation, the analytical signal versus concentration dependence was linear from 1.0 to 100 ppb with a detection limit of 0.5 ppb. The interference from common metal ions was minimized by addition of ethylenediaminetetraacetate (EDTA) into the sample solution. The use of nafion also improves the resistance to interference from surfactants.  相似文献   

5.
Single-wall carbon nanotubes (SWNT) were dispersed into water in the presence of dicetyl phosphate (DCP), and then a SWNT-DCP film-coated glassy carbon electrode (GCE) was constructed. The electrochemical behavior of acetaminophen at bare GCE and SWNT-DCP modified GCE were compared, suggesting that the SWNT-DCP-modified GCE significantly enhances the oxidation peak current of acetaminophen. A sensitive and simple electrochemical method with a good linear relationship in the range of 1.0 × 10−7–2.0 × 10−5 mol L−1, was developed for the determination of acetaminophen. The detection limit is 4.0 × 10−8 mol L−1 for 3-min accumulation. This method was successfully demonstrated with tablets.  相似文献   

6.
7.
This work exploited a sequential injection lab-on-valve (LOV) system for the determination of cadmium by anodic stripping voltammetry (ASV). A miniaturized electrochemical flow cell (EFC) was fabricated in LOV, in which a nafion coated bismuth film electrode was used as working electrode. The cadmium was electrodeposited on the electrode surface in bismuth solution, and measured with the subsequential stripping scan. Under optimal conditions, the proposed system responded linearly to cadmium concentrations in a range 2.0-100.0 μg L−1. The detection limit of this method was found to be 0.88 μg L−1. By loading a sample volume of 800 μL, a sampling frequency of 22 determinations h−1 was achieved. The repeatability expressed as relative standard derivation (R.S.D.) was 3.65% for 20 μg L−1 cadmium (n = 11). The established method was applied to analysis of trace cadmium in environmental water samples and the spiked recoveries were satisfactory.  相似文献   

8.
Chunya Li 《Mikrochimica acta》2007,157(1-2):21-26
Multi-wall carbon nanotubes (MWNT) were dispersed into water in the presence of dicetyl phosphate (DCP), and MWNT-DCP composite film coated glassy carbon electrodes (GCE) were constructed. The electrochemical properties of 2-chlorophenol at a bare GCE and MWNT-DCP modified GCE were compared. It was found that MWNT-DCP modified GCEs significantly enhance the oxidation peak current of 2-chlorophenol and lowers its oxidation overpotential, suggesting great potential in the sensitive determination of 2-chlorophenol. Finally, a sensitive and simple voltammetric method was developed for the determination of 2-chlorophenol. The oxidation peak current increases linearly with the concentration in the range of 1.0 × 10−7–2.0 × 10−5 mol L−1, and the detection limit is 4.0 × 10−8 mol L−1 for 2 min accumulation. The method was successfully used to determine 2-chlorophenol in waste water samples.  相似文献   

9.
An electrochemical method for the determination of trace levels of mercury based on a multi-walled carbon nanotubes (MWNT) film coated glassy carbon electrode (GCE) is described. In 0.1 mol L–1 HCl solution containing 0.02 mol L–1 KI, Hg2+ was firstly preconcentrated at the MWNT film and then reduced at –0.60 V. During the anodic potential sweep, reduced mercury was oxidized, and then a sensitive and well-defined stripping peak at about –0.20 V appeared. Under identical conditions, a MWNT film coated GCE greatly enhances the stripping peak current of mercury in contrast to a bare GCE. Low concentrations of I remarkably improve the determining sensitivity, since this increases the accumulation efficiency of Hg2+ at the MWNT film coated GCE. The stripping peak current is proportional to the concentration of Hg2+ over the range 8×10–10–5×10–7 mol L–1. The lowest detectable concentration of Hg2+ is 2×10–10 mol L–1 at 5 min accumulation. The relative standard deviation (RSD) at 1×10–8 mol L–1 Hg2+ was about 6% (n=10). By using this proposed method, Hg2+ in some water samples was determined, and the results were compared with those obtained by atomic absorption spectrometry (AAS). The two results are similar, suggesting that the MWNT-film coated GCE has great potential in practical analysis.  相似文献   

10.
11.
An adsorptive stripping voltammetric method for the determination of the pesticide dinoseb (2-sec.-butyl-4,6-dinitrophenol) at the mercury film electrode is described. The deposition of the mercury film on a glassy carbon disk electrode was optimized. The temperature, at which the mercury film was deposited, was demonstrated to have a strong influence on the stripping peaks, the first one being much more intense than the second. A systematic study of the variables affecting the stripping response was carried out by differential pulse voltammetry. The results obtained have been compared with those at the HMDE; a significant improvement in the sensitivity of the method developed with the MFE was observed. Using a 300 s accumulation time, the limits of determination and detection were 3.6 × 10–10 and 1.1 × 10–10 mol L–1, respectively. The effect of the presence of several herbicides on the dinoseb response was also tested. The method has been applied to the determination of the pesticide in spiked apple juice at two concentration levels: 12.0 and 1.2 g L–1 of juice.  相似文献   

12.
The electrochemical behavior of roxithromycin (RM) at a single-wall carbon nanotube (SWNT) coated glassy carbon (GC) electrode was studied. It was found that RM could produce an irreversible anodic peak at the electrode. When the pH of supporting electrolyte (i.e. phosphate buffer solution) was 7 the peak potential was 0.86V (vs. SCE). The electrochemical reaction contained electron and proton transfer, and the electron-transfer coefficient (α) was ca. 0.87. The anodic peak depended on the adsorption of RM, the maximum adsorption amount was about 3.99×10(-10)molcm(-2). The adsorbed RM could be removed by cycling between 0.1 and 1.1V in a blank solution for about two minutes, and the electrode thus could be regenerated. Under the optional conditions, the anodic peak current was linear to RM concentration over the range of 5.0×10(-6) to 1.0×10(-4)M. The limit of detection was 5.0×10(-7)M (S/N=3) for 180s accumulation at -0.8V. The modified electrode had good stability and repeatability, and it was successfully applied to the determination of RM in medicine samples.  相似文献   

13.
Gustavsson I  Lundström K 《Talanta》1983,30(12):959-962
The potential applicability of a pyrolytic carbon film electrode in the differential-pulse anodic-stripping voltammetric determination of cadmium and lead in sea-water is demonstrated. The performance at the 10−10M level is compared with that of a satisfactory glassy-carbon electrode. The two types of electrode display comparable behaviour in anodic-stripping voltammetry, but the pyrolytic carbon film electrode needs less pretreatment.  相似文献   

14.
Magnesium l-ascorbic acid 2-phosphate (MAAP) and α-tocopherol acetate (α-TAc), as the stable vitamin C and vitamin E derivative, respectively, are often applied to skin care products for reducing UV damage. The encapsulation of MAAP (0.5%, g/mL) and α-TAc (5%, g/mL) together within the polyacrylonitrile (PAN) nanofibers was demonstrated using a coaxial electrospinning technique. The structure and morphology characterizations of the core-shell fibers MAAP/α-TAc-PAN were investigated by SEM, FTIR and XRD. As a negative control, the blend nanofibers MAAP/α-TAc/PAN were prepared from a normal electrospinning method. The results from SEM indicated that the morphology and diameter of the nanofibers were influenced by concentration of spinning solution, the polymer component of the shell, the carrying agent of the core and the fabricating methods, and the core-shell nanofibers obtained at the concentration of 8% had finer and uniform structure with the average diameters of 200 ± 15 nm. From in vitro release studies it could be seen that both different fiber specimens showed a gradual increase in the amount of α-TAc or MAAP released from the nanofibers. Furthermore, α-TAc and MAAP released from the blend nanofibers showed the burst release at the maximum release of ~15% and ~40% during the first 6 h, respectively, but their release amount from the core-shell nanofibers was only 10–12% during the initial part of the process. These results showed that core-shell nanofibers alleviated the initial burst release and gave better sustainability compared to that of the blend nanofibers. The present study would provide a basis for further optimization of processing conditions to obtain desired structured core-shell nanofibers and release kinetics for practical applications in dermal tissue.  相似文献   

15.
In this work, an electrochemical sensor 1-phenyl-3-methyl-4-(2-furoyl)-5-pyrazolone/multiwalled carbon nanotubes/glassy carbon electrode (GCE) was prepared for the determination of xanthine (XN) in the presence of an excess of uric acid. Cyclic voltammetry and differential pulse voltammetry were used to characterize the electrode. The oxidation of XN occurred in a well-defined peak having E p 0.73 V in phosphate buffer solution of pH 6.0. Compared with the bare GCE, the electrochemical sensor greatly enhanced the oxidation signal of XN with negative shift in peak potential about 110 mV. Based on this, a sensitive, rapid, and convenient electrochemical method for the determination of XN has been proposed. Under the optimized conditions, the oxidation peak current of XN was found to be proportional to its concentration in the range of 0.3~50 μM with a detection limit of 0.08 μM. The analytical utility of the proposed method was demonstrated by the direct assay of XN in urine samples and was found to be promising at our preliminary experiments.  相似文献   

16.
运用循环伏安法及线性扫描伏安法研究了间苯二胺在金纳米粒子/碳纳米管修饰玻碳电极上的电化学行为,优化并建立了一种直接测定间苯二胺的电化学分析方法。结果表明,与裸玻碳电极相比,金纳米粒子/碳纳米管修饰电极能显著提高间苯二胺的氧化峰电流。在优化条件下,氧化峰电流与间苯二胺浓度在3.0×10-8~1.0×10-6mol/L范围内呈现良好的线性关系,检出限为1.0×10-8mol/L,对1.0×10-7mol/L的间苯二胺溶液平行测定10次的RSD为4.2%。测定了实验室废水中的间苯二胺含量,3次测定结果的平均回收率为99.7%,RSD为2.1%。  相似文献   

17.
壳聚糖修饰玻碳电极卷积伏安法测定环境水中的EDTA   总被引:1,自引:0,他引:1  
制备了壳聚糖修饰玻碳电极 ,研究了Fe(EDTA) -在修饰电极上的吸附还原行为 ,用卷积伏安法通过Fe(EDTA) -的检测测定了环境水中的EDTA。在优化的实验条件下 ,峰电流值与 8.0× 1 0 -7~ 5 .0× 1 0 -6mol L的EDTA呈线性关系 ,回归方程为epp′ =0 .75 2 5c - 0 .661 3,r =0 .991 ,最低检出限为 5 .0× 1 0 -7mol L ,5次测定的相对标准偏差小于 5 .8%。对实际样品测定的回收率为98 1 %~ 1 0 5 % ,对比HPLC的结果 ,相对偏差小于 5 %。  相似文献   

18.
19.
The oxidation of acetaminophen was studied at a glassy carbon electrode modified with multi-walled carbon nanotubes and a graphite paste. Cyclic voltammety, differential pulse voltammetry and square wave voltammetry at various pH values, scan rates, and the effect of the ratio of nanotubes to graphite were investigated in order to optimize the parameters for the determination of acetaminophen. Square wave voltammetry is the most appropriate technique in giving a characteristic peak at 0.52 V at pH 5. The porous nanostructure of the electrode improves the surface area which results in an increase in the peak current. The voltammetric response is linear in the range between 75 and 2000 ng.mL?1, with standard deviations between 0.25 and 7.8%, and a limit of detection of 25 ng.mL?1. The method has been successfully applied to the analysis of acetaminophen in tablets and biological fluids.  相似文献   

20.
In this work, a multi-wall carbon nanotube (MWNT) film-modified glassy carbon electrode (GCE) was constructed for the determination of 8-hydroxydesoxyguanosine (8-OHdG). The electrochemical behaviors of 8-OHdG were examined using cyclic voltammetry (CV) and linear sweep voltammetry (LSV), suggesting that MWNT film facilitates the electron transfer of 8-OHdG and then significantly enhances the oxidation peak current of 8-OHdG. Finally, a sensitive and simple electrochemical method with a good linear relationship in the range of 8.0 × 10−8 ∼ 5.0 × 10−6 mol 1−1, was developed for the determination of 8-OHdG. The detection limit is 9.0 × 10−9 mol 1−1 for 6-min accumulation. This newly-proposed method was successfully used to detect 8-OHdG in urine samples. Published in Russian in Elektrokhimiya, 2008, Vol. 44, No. 3, pp. 351–356. The text was submitted by the authors in English.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号