首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
Molecular images of documents were obtained by sequentially scanning the surface of the document using desorption atmospheric pressure chemical ionization mass spectrometry (DAPCI‐MS), which was operated in either a gasless, solvent‐free or methanol vapor‐assisted mode. The decay process of the ink used for handwriting was monitored by following the signal intensities recorded by DAPCI‐MS. Handwritings made using four types of inks on four kinds of paper surfaces were tested. By studying the dynamic decay of the inks, DAPCI‐MS imaging differentiated a 10‐min old from two 4 h old samples. Non‐destructive forensic analysis of forged signatures either handwritten or computer‐assisted was achieved according to the difference of the contour in DAPCI images, which was attributed to the strength personalized by different writers. Distinction of the order of writing/stamping on documents and detection of illegal printings were accomplished with a spatial resolution of about 140 µm. A Matlab® written program was developed to facilitate the visualization of the similarity between signature images obtained by DAPCI‐MS. The experimental results show that DAPCI‐MS imaging provides rich information at the molecular level and thus can be used for the reliable document analysis in forensic applications. © 2013 The Authors. Journal of Mass Spectrometry published by John Wiley & Sons, Ltd.  相似文献   

3.
Desorption electrospray ionization mass spectrometry (DESI-MS) is employed in the forensic analysis of documents. Blue ballpoint pen inks applied to ordinary writing paper are examined under ambient conditions without any prior sample preparation. When coupled to an automated moving stage, two-dimensional molecular images are generated. Proof-of-principle experiments include characterization of a simulated forged number and examination of older written records. This application of DESI has advantages over extractive techniques in terms of speed and sample preservation. The effects of the desorbing solvent composition, in this case a mixture of methanol and water, and of flow rate, are evaluated. Results suggest that the solubility of the analyte (dyes Basic Blue 7, Basic Violet 3 and Solvent Blue 26) plays an important role in desorption from the paper surface.  相似文献   

4.
An atmospheric pressure ionization source based on desorption electrospray ionization technology for a bench-top hybrid FTICR mass spectrometer is described. The ion source was characterized using low-molecular-weight-weight pharmaceutical samples. The dependences of signal intensities on various experimental parameters (solvent composition, surface temperature, spray voltage, etc.) were studied. Based on the results obtained, plausible mechanisms of desorption electrospray ionization for the analytes under the study are discussed.  相似文献   

5.
Desorption electrospray ionization (DESI), an established ambient ionization method in mass spectrometry (MS) for the analysis of organic compounds, is applied here to trace detection of inorganic salts, including inorganic oxidants. In-situ surface analysis of targeted compounds, including nitrogen-, halogen- and sulfur-salts, down to sub-nanogram levels, was performed using DESI-MS. Successful experiments were carried out in both the negative and the positive ion modes; simple anions and cations as well as small cluster ions were observed. Various surfaces are examined and surface porosity effects were briefly explored. Absolute detection limits on porous polytetrafluoroethylene (PTFE) of 120 pg (surface concentration 0.07 ng mm−2) and 50 pg (surface concentration 0.03 ng mm−2), were achieved for sodium chlorate and sodium perchlorate, respectively. The compounds of interest were examined in the presence of a hydrocarbon mixture to assess matrix effects: only a two- or three-fold decrease in the target ion intensity was observed. Commercial fireworks were analyzed to determine perchlorate salts in complex mixtures. This work demonstrates the potential applicability of ambient ionization mass spectrometry to forensic investigations involving improvised explosives.   相似文献   

6.
In this article, the effect of spray solvent on the analysis of selected lipids including fatty acids, fat‐soluble vitamins, triacylglycerols, steroids, phospholipids, and sphingolipids has been studied by two different ambient mass spectrometry (MS) methods, desorption electrospray ionization‐MS (DESI‐MS) and desorption atmospheric pressure photoionization‐MS (DAPPI‐MS). The ionization of the lipids with DESI and DAPPI was strongly dependent on the spray solvent. In most cases, the lipids were detected as protonated or deprotonated molecules; however, other ions were also formed, such as adduct ions (in DESI), [M‐H]+ ions (in DESI and DAPPI), radical ions (in DAPPI), and abundant oxidation products (in DESI and DAPPI). DAPPI provided efficient desorption and ionization for neutral and less polar as well as for ionic lipids but caused extensive fragmentation for larger and more labile compounds because of a thermal desorption process. DESI was more suitable for the analysis of the large and labile lipids, but the ionization efficiency for less polar lipids was poor. Both methods were successfully applied to the direct analysis of lipids from pharmaceutical and food products. Although DESI and DAPPI provide efficient analysis of lipids, the multiple and largely unpredictable ionization reactions may set challenges for routine lipid analysis with these methods. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

7.
Aspects of the development of mass spectrometry over the past three decades are briefly reviewed and growth points in the subject are identified. Molecular imaging by mass spectrometry is one such growth area. The development of a capability for 2D chemical imaging of surfaces is described, based on the combination of a desorption electrospray ionization (DESI) ion source with an automated surface stage capable of x, y translational motion. The lateral resolution of this new system is found to be less than 200 microns, using a test ink pattern. Chemical imaging of surfaces is demonstrated using model examples of organic and biological systems: (i) imaging of a 2D pattern written in different colored inks on photographic paper and (ii) imaging of thin coronal sections of rat brain tissue fixed onto a glass microscope slide. In both cases, full mass spectra are recorded as a function of x,y-position on the surface. In the chemical imaging example, the distributions of the two different inks on the paper surface were mapped by tracking the abundance of the intact organic cation which characterizes each particular ink dye. In the tissue imaging example, distributions of specific lipids in coronal sections of rat brain tissue were followed from the abundance distributions in 2D space of the deprotonated lipid molecules recorded in the negative ion mass spectra. These latter distributions reveal distinct anatomical features of the rat brain. The results of these studies demonstrate the feasibility of performing surface imaging studies using DESI and show that at this stage of its development it has a lateral spatial resolution of a few hundred microns.  相似文献   

8.
A liquid chromatography/mass spectrometry (LC/MS) method using desorption electrospray ionization (DESI) as a versatile interface has been established, which allows a wide range of elution flow rates, online derivatization via reactive DESI and further combination with electrochemistry.  相似文献   

9.
Chemical profiling of barley (Hordeum vulgare) leaves was demonstrated using direct and indirect desorption electrospray ionization (DESI) imaging mass spectrometry. Direct DESI analysis of the untreated leaves was not possible despite a significant content of hydroxynitrile glucosides known to reside in the epidermis of the leaves. Instead, the epidermis was stripped off the leaves, thus allowing direct DESI imaging to be performed on the back of the epidermis. Furthermore, indirect DESI imaging was performed by making imprints in porous Teflon of the intact leaves as well as of the stripped epidermis. The DESI images reveal accumulation of hydroxynitrile glucosides in the leaf epidermis, homogeneously distributed throughout the surface. The indirect DESI approach enables relative quantitation, confirming variations of hydroxynitrile glucosides content in primary leaves of three different cultivars of barley seedlings. The study presents an example of how to overcome the morphological barriers from the plant surface and perform rapid and repeatable DESI imaging. In addition, a comparison is made of direct and indirect DESI imaging, contributing to the characterization of the recently developed method of indirect DESI imaging of plant material via porous Teflon imprints.  相似文献   

10.
Clinically obtained human kidney stones of different pathogenesis were dissolved in acetic acid/methanol solutions and then rapidly analyzed by surface desorption atmospheric pressure chemical ionization mass spectrometry (SDAPCI-MS) without any desalination treatment. The mass spectral fingerprints of six groups of kidney stone samples were rapidly recorded in the mass range of m/z 50-400. A set of ten melamine-induced kidney stone samples and nine uric acid derived kidney stone samples were successfully differentiated from other groups by principal component analysis of SDAPCI-MS fingerprints upon positive-ion detection mode. In contrast, the mass spectra recorded using negative-ion detection mode did not give enough information to differentiate those stone samples. The results showed that in addition to the melamine, the chemical compounds enwrapped in the melamine-induced kidney stone samples differed from other kidney stone samples, providing useful hints for studying on the formation mechanisms of melamine-induced kidney stones. This study also provides useful information on establishing a MS-based platform for rapid analysis of the melamine-induced human kidney stones at molecular levels.  相似文献   

11.
12.
Surface-assisted laser desorption/ionization (SALDI) substrates have been fabricated using nanospiked polyurethane (PU) substrates that are replicated by a low-cost soft nanolithography method from silicon nanospike structures formed with femtosecond laser irradiations. The strongest mass spectrometry (MS) signal of Angiotensin II was obtained on 45-nm Au-coated nanospiked PU substrates. The effective ionization appears to be due to surface plasmon excitation. Such low-cost and identical SALDI substrates can be used for MS analysis of various molecules with high reproducibility.  相似文献   

13.
14.
The salt tolerance of desorption electrospray ionization (DESI) was systematically investigated by examining three different drug mixtures in the presence of 0, 0.2, 2, 5, 10, and 20% NaCl:KCl (1:1) from different surfaces. At physiological salt concentrations, the individual drugs in each mixture were observed in each experiment. Even at salt concentrations significantly above physiological levels, particular surfaces were effective in providing spectra that allowed the ready identification of the compounds of interest in low nanogram amounts. Salt adducts, which are observed even in the absence of added salt, could be eliminated by adding 0.1% 7 M ammonium acetate to the standard methanol:water (1:1) spray solvent. Comparison of the salt tolerance of DESI with that of electrospray ionization (ESI) demonstrated better signal/noise characteristics for DESI. The already high salt tolerance of DESI can be optimized further by appropriate choices of surface and spray solution.  相似文献   

15.
An on-probe pyrolyzer has been constructed and interfaced with desorption electrospray ionization (DESI) mass spectrometry (MS) for the rapid analysis of non-volatile pyrolysis products. The detection and analysis of non-volatile pyrolysis products of peptides, proteins and the synthetic polymer poly(ethylene glycol) were demonstrated with this instrument. The on-probe pyrolyzer can be operated off-line or on-line with the DESI source and was interfaced with a tandem MS (MS/MS) instrument, which allowed for structure characterization of the non-volatile pyrolytic products. Advantages of this system are its simplicity and speed of analysis since the pyrolysis is performed in situ on the DESI source probe and hence, it avoids extraction steps and/or the use of matrices (e.g., as in MALDI–MS analyses).  相似文献   

16.
An on-probe pyrolyzer has been constructed and interfaced with desorption electrospray ionization (DESI) mass spectrometry (MS) for the rapid analysis of non-volatile pyrolysis products. The detection and analysis of non-volatile pyrolysis products of peptides, proteins and the synthetic polymer poly(ethylene glycol) were demonstrated with this instrument. The on-probe pyrolyzer can be operated off-line or on-line with the DESI source and was interfaced with a tandem MS (MS/MS) instrument, which allowed for structure characterization of the non-volatile pyrolytic products. Advantages of this system are its simplicity and speed of analysis since the pyrolysis is performed in situ on the DESI source probe and hence, it avoids extraction steps and/or the use of matrices (e.g., as in MALDI–MS analyses).  相似文献   

17.
The number and type of atmospheric pressure techniques suitable for sampling analytes from surfaces, forming ions from these analytes, and subsequently transporting these ions into vacuum for interrogation by MS have rapidly expanded over the last several years. Moreover, the literature in this area is complicated by an explosion in acronyms for these techniques, many of which provide no information relating to the chemical or physical processes involved. In this tutorial article, we sort this vast array of techniques into relatively few categories on the basis of the approaches used for surface sampling and ionization. For each technique, we explain, as best known, many of the underlying principles of operation, describe representative applications, and in some cases, discuss needed research or advancements and attempt to forecast their future analytical utility. Copyright (c) 2008 John Wiley & Sons, Ltd.  相似文献   

18.
Electrospray laser desorption ionization mass spectrometry (ELDI/MS) was used to rapidly distinguish authentic banknotes from counterfeits of the US dollar and the New Taiwan dollar. The banknotes' surfaces were irradiated with a pulsed ultraviolet laser, after which the desorbed ink compounds entered an electrospray plume and formed ions via interactions with charged solvent species. Authentic banknotes were found to differ from their counterfeit equivalents in their surface chemical compositions. The detected chemical compounds included various polymers, plasticizers and inks; these results were comparable with those obtained using solvent extraction followed by electrospray ionization mass spectrometry analysis. Because of the high spatial resolution of the laser beam, ELDI/MS analysis resulted in minimal damage to the banknotes. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

19.
Steroids have important roles in the progress of pregnancy, and their study in maternal urine is a non-invasive method to monitor the steroid metabolome and its possible abnormalities. However, the current screening techniques of choice, namely immunoassays and gas and liquid chromatography–mass spectrometry, do not offer means for the rapid and non-targeted multi-analyte studies of large sample sets. In this study, we explore the feasibility of two ambient mass spectrometry methods in steroid fingerprinting. Urine samples from pregnant women were screened by desorption electrospray ionization (DESI) and desorption atmospheric pressure photoionization (DAPPI) Orbitrap high resolution mass spectrometry (HRMS). The urine samples were processed by solid phase extraction for the DESI measurements and by enzymatic hydrolysis and liquid–liquid-extraction for DAPPI. Consequently, steroid glucuronides and sulfates were detected by negative ion mode DESI–HRMS, and free steroids by positive ion mode DAPPI–HRMS. In DESI, signals of eleven steroid metabolite ions were found to increase as the pregnancy proceeded, and in DAPPI ten steroid ions showed at least an order of magnitude increase during pregnancy. In DESI, the increase was seen for ions corresponding to C18 and C21 steroid glucuronides, while DAPPI detected increased excretion of C19 and C21 steroids. Thus both techniques show promise for the steroid marker screening in pregnancy.  相似文献   

20.
Matrix-assisted laser desorption/ionization - imaging mass spectrometry is an alternative tool, which can be implemented in order to obtain and visualize the “omic” signature of tissue samples. Its application to clinical study enables simultaneous imaging-based morphological observations and mass spectrometry analysis. Application of fully informative material like tissue allows obtaining the complex and unique profile of analyzed samples. This knowledge leads to diagnosing disease, studying the mechanism of cancer development, selecting the potential biomarkers as well as correlating obtained images with prognosis. Nevertheless, it is worth noticing that this method is found to be objective but the result of the analysis is mainly influenced by the sample preparation protocol, including the collection of biological material, its preservation, and processing. However, the application of this approach requires a special sample preparation procedure. The main goal of the study is to present the current knowledge on the clinical application of matrix-assisted laser desorption/ionization with imaging mass spectrometry in cancer research, with particular emphasis on the sample preparation step. For this purpose, several protocols based on cryosections and formalin-fixed paraffin-embedded tissue were compiled and compared, taking into account the measured metabolites of potential diagnostic importance for a given type of cancer.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号