首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Abstract

This study develops a method for solid phase microextraction (SPME) of ten widespread herbicides from water. The selected herbicides belong to different chemical groups are EPTC, molinate, propachlor, trifluralin, atrazine, propazine, terbuthylazine, prometryne, alachlor. Their determination was carried out by gas chromatography with flame thermionic and mass spectrometric detection. To perform the SPME, two types of fibre have been assayed: Carbowax-divinylbenzene (CW-DVB) of 65 μm thickness and polydimethylsiloxane-divinylbenzene (PDMS-DVB) of 65 μm thickness. The main factors affecting the SPME process such as pH, ionic strength, methanol content, memory effect, stirring rate and adsorption-time profile were studied. The method was applied to spiked natural waters such as ground water, sea water, lake water and river water in a concentration range of 0.1 to 10 μg/L. Limits of detection with each of the detectors were determined to be 1 – 20 ng/L in PDMS-DVB and 2–20 ng/L CW-DVB fibres. The recoveries of herbicides compared to distilled water were in relatively high levels 78.3–127.3 % and the average r2 values of the calibration curves were above 0.99 for all the analytes. The SPME conditions were finally optimized in order to obtain maximum sensitivity and samples were applied for the trace-level determination in river water samples originating from Ioannina region (Greece).  相似文献   

2.
This study develops a method for the analysis of seven fungicides in environmental waters, using solid-phase microextraction (SPME). The analyzed compounds--dicloran, chlorothalonil, vinclozolin, dichlofluanid, captan, folpet and captafol--belong to different classes of chemical compound (chloroanilines, sulphamides, phthalimides and oxazolidines) and are used mainly in agriculture and as antifouling paints. Their determination was carried out by gas chromatography with electron-capture and mass spectrometric detection. To perform SPME, four types of fibre have been assayed and compared: polyacrylate (85 microm), polydimethylsiloxane (100 and 30 microm), carbowax-divinylbenzene (CW-DVB 65 microm) and polydimethylsiloxane-divinylbenzene (65 microm). The main parameters affecting the SPME process such as pH, salt additives, methanol content, memory effect, stirring rate and adsorption-time profile were studied. The method was developed using spiked natural waters such as ground water, sea water, river water and lake water in a concentration range of 0.1-10 microg/l. Limits of detection of studied compounds were determined in the range of 1-60 ng/l, by using electron-capture and mass spectrometric detectors. The recoveries of all fungicides were in relatively high levels (70.0-124.4%) and the average R2 values of the calibration curves were above 0.990 for all the analytes. The SPME conditions were finally optimized in order to obtain the maximum sensitivity. The potential of the proposed method was realized by applying it to the trace-level screening determination of fungicides and antifouling compounds in sea water samples originating from various Greek marinas.  相似文献   

3.
刘志超  胡霞林  刘景富 《色谱》2010,28(5):513-516
以涂有聚二甲基硅氧烷(PDMS)的石英光导纤维作为固相微萃取纤维,建立了一次性固相微萃取与高效液相色谱联用测定环境水样中的菲、荧蒽和屈3种多环芳烃(PAHs)的方法。实验考察了解吸时间、萃取时间、搅拌速度、盐效应以及样品溶液pH值对萃取效率的影响,优化得到的萃取和解吸条件为: 于60 mL样品溶液中放入两段萃取纤维(1.5 cm)和1.2 g氯化钠,在1200 r/min搅拌速度下萃取60 min,取出萃取纤维并转入120 μL甲醇中密封静置解吸24 h后,取20 μL解吸液进行液相色谱测定。该方法对于菲、荧蒽和屈的检出限分别为0.17、0.17和0.08 μg/L;精密度(以测定0.5 μg/L PAHs标准溶液6次的相对标准偏差计)小于8%;实际样品中3种PAHs的加标回收率为80.0%~107%。该方法快速简便,纤维一次性使用,克服了污染物在纤维上残留的问题。  相似文献   

4.
Solid-phase microextraction (SPME) has been optimized and applied to the determination of the organophosphorus insecticides diazinon, dichlofenthion, parathion methyl, malathion, fenitrothion, fenthion, parathion ethyl, bromophos methyl, bromophos ethyl, and ethion in natural waters. Four types of SPME fiber coated with different stationary phases (PDMS, PA, PDMS-DVB, and CW-DVB) were used to examine their extraction efficiencies for the compounds tested. Conditions that might affect the SPME procedure, such as extraction time and salt content, were investigated to determine the analytical performance of these fiber coatings for organophosphorus insecticides. The optimized procedure was applied to natural waters - tap, sea, river, and lake water - spiked in the concentration range 0.5 to 50 micro g L(-1) to obtain the analytical characteristics. Recoveries were relatively high - >80% for all types of aqueous sample matrix - and the calibration plots were reproducible and linear (R(2)>0.982) for all analytes with all the fibers tested. The limits of detection ranged from 2 to 90 ng L(-1), depending on the detector and the compound investigated, with relative standard deviations in the range 3-15% at all the concentration levels tested. The SPME partition coefficients (K(f)) of the organophosphorus insecticides were calculated experimentally for all the polymer coatings. The effect of organic matter such as humic acids on extraction efficiency was also studied. The analytical performance of the SPME procedure using all the fibers in the tested natural waters proved effective for the compounds.  相似文献   

5.
The use of a different optimization procedure that involves Experimental Design (ED) and Artificial Neural Networks (ANN) for the off-line coupling solid-phase microextraction-micellar electokinetic chomatography (SPME-MEKC) is presented. This combination of ED and ANN, mathematical tools not previously used in SPME-MEKC optimization, allowed us to obtain good extraction efficiencies in the SPME procedure for the determination of a group of eleven triazine herbicides in groundwater samples. Both extraction and desorption steps were carried out by solution stirring at 900 rpm. Optimal conditions for the off-line SPME procedure were: extraction with a poly(dimethylsiloxane)/divinylbenzene SPME fiber for 120 min, 10% (w/v) NaCl, desorption time 40 min, and 70% (v/v) of methanol/buffer as desorption mixture. Detection limits lay between 0.80 microg L(-1) and 4.89 microg L(-1). Finally, the optimized method was applied to the determination of these compounds in spiked and non-spiked groundwater samples using a previously optimized MEKC separation.  相似文献   

6.
Headspace solid-phase microextraction (HS-SPME) has been developed for the analysis of seven organophosphorus insecticides, i.e. diazinon, fenitrothion, fenthion, ethyl parathion, methyl bromophos, ethyl bromophos and ethion in natural waters. Their determination was carried out using gas chromatography with flame thermionic and mass spectrometric detection. To perform the HS-SPME, two types of fibre have been assayed and compared: polyacrylate (PA 85 microm), and polydimethylsiloxane (PDMS 100 microm). The main parameters affecting the HS-SPME process such as temperature, salt additives, memory effect, stirring rate and adsorption-time profile were studied. The method was developed using spiked natural waters such as ground, sea, river and lake water in a concentration range of 0.05-1 microg/l. The HS-SPME conditions were optimized in order to obtain the maximum sensitivity. Detection limits varied from 0.01 to 0.04 microg/l and relative standard deviations (RSD <17%) were obtained showing that the precision of the method is reliable. The method showed also good linearity for the tested concentration range with regression coefficients ranging between 0.985 and 0.999. Recoveries were in relatively high levels for all the analytes and ranged from 80 to 120%. Water samples collected from different stations along the flow of Kalamas river (NW Greece) were analyzed using the optimized conditions in order to evaluate the potential of the proposed method to the trace-level screening determination of organophosphorus insecticides. The analysis with HS-SPME has less background interference and the advantage of its non-destructive nature reveal the possibility of the repetitive use of the SPME fibre.  相似文献   

7.
Graphene is a novel and interesting carbon material that could be used for the separation and purification of some chemical compounds. In this investigation, graphene was used as a novel fiber‐coating material for the solid‐phase microextraction (SPME) of four triazine herbicides (atrazine, prometon, ametryn and prometryn) in water samples. The main parameters that affect the extraction and desorption efficiencies, such as the extraction time, stirring rate, salt addition, desorption solvent and desorption time, were investigated and optimized. The optimized SPME by graphene‐coated fiber coupled with high‐performance liquid chromatography‐diode array detection (HPLC‐DAD) was successfully applied for the determination of the four triazine herbicides in water samples. The linearity of the method was in the range from 0.5 to 200 ng/mL, with the correlation coefficients (r) ranging from 0.9989 to 0.9998. The limits of detection of the method were 0.05‐0.2 ng/mL. The relative standard deviations varied from 3.5 to 4.9% (n=5). The recoveries of the triazine herbicides from water samples at spiking levels of 20.0 and 50.0 ng/mL were in the range between 86.0 and 94.6%. Compared with two commercial fibers (CW/TPR, 50 μm; PDMS/DVB, 60 μm), the graphene‐coated fiber showed higher extraction efficiency.  相似文献   

8.
采用一步合成法制备磁性氧化石墨烯材料(GO-Fe_3O_4),将其用作磁性固相吸附剂对环境水样中的6种三嗪类除草剂进行萃取和富集,并与高效液相色谱-串联质谱法相结合进行测定。以扫描电镜和傅立叶红外光谱对合成材料进行了表征,并考察了GO-Fe_3O_4用量、萃取时间、水样的pH值及离子强度和解吸条件等因素对萃取效率的影响。6种三嗪类除草剂的检出限为0.1~1.0 ng/L,富集倍数可达616~902倍。将方法应用于苏州地区太湖水、运河水和护城河水等实际水样的分析,加标回收率为85.4%~117.6%,相对标准偏差为1.2%~10.0%。该方法操作简单快速,富集倍数较高,检出限低,可用于水样中痕量三嗪类除草剂残留的检测。  相似文献   

9.
A polypyrrole (Ppy)/graphene (G) composite was developed and applied as a novel coating for use in solid-phase microextraction (SPME) coupled with gas chromatography (GC). The Ppy/G-coated fiber was prepared by electrochemically polymerizing pyrrole and G on a stainless-steel wire. The extraction efficiency of Ppy/G-coated fiber for five phenols was the highest compared with the fibers coated with either Ppy or Ppy/graphene oxide (GO) using the same method preparation. Significantly, compared with various commercial fibers, the extraction efficiency of Ppy/G-coated fiber is better than or comparable to 85 μm CAR/PDMS fiber (best extraction efficiency of phenol, o-cresol, and m-cresol in commercial fibers) and 85 μm polyacrylate (PA) fiber (best extraction efficiency of 2,4-dichlorophenol and p-bromophenol in commercial fibers). The effects of extraction and desorption parameters such as extraction time, stirring rate, and desorption temperature and time on the extraction/desorption efficiency were investigated and optimized. The calibration curves were linear from 10 to 1000 μg/L for o-cresol, m-cresol, p-bromophenol, and 2,4-dichlorophenol, and from 50 to 1000 μg/L for phenol. The detection limits were within the range 0.34-3.4 μg/L. The single fiber and fiber-to-fiber reproducibilities were <8.3 (n=7) and 13.3% (n=4), respectively. The recovery of the phenols spiked in natural water samples at 200 μg/L ranged from 74.1 to 103.9% and the relative standard deviations were <3.7%.  相似文献   

10.
This study develops a method for the analysis of biocides Irgarol 1051 and Sea Nine 211 in environmental water samples, using solid-phase microextraction (SPME). Their determination was carried out using gas chromatography with flame thermionic (FTD), electron-capture (ECD) and mass spectrometric detection. The main parameters affecting the SPME process such as adsorption-time profile, salt additives and memory effect were studied for five polymeric coatings commercially available for solid-phase microextraction: poly(dimethylsiloxane) (100 and 30 microm), polyacrylate, poly(dimethylsiloxane)-divinylbenzene (PDMS-DVB 65 microm) and Carbowax-divinylbenzene (65 microm). The method was developed using spiked natural waters such as tap, river, sea and lake water in a concentration range of 0.5-50 microg/l. All the tested fiber coatings have been evaluated with regard to sensitivity, linear range, precision and limits of detection. Typical RSD values (triplicate analysis) in the range of 3-10% were obtained depending on the fiber coating and the compound investigated. The recoveries of biocides were in relatively high levels 60-118% and the calibration curves were reproducible and linear (R2>0.990) for both analytes. The SPME partition coefficients (Kf) of both compounds were also calculated experimentally in the proposed conditions for all fibers using direct sampling. Finally the influence of organic matter such as humic acids on extraction efficiency was studied, affecting mostly Sea Nine 211 uptake by the fiber. Optimum analytical SPME performance was achieved using the PDMS-DVB 65 microm fiber coating in ECD and FTD systems for Sea Nine 211 and Irgarol 1051, respectively.  相似文献   

11.
The solid-phase microextraction (SPME) technique using a 75 mm film of carboxen/polydimethylsiloxane was applied to the analysis of chloroacetanilide herbicides (acetochlor, alachlor, butachlor, metolachlor, and propachlor) residues. The feasibility of SPME with gas chromatography electron capture detection analysis has been evaluated. The effects of experimental parameters such as magnetic stirring, salt addition, humic acid addition, pH value, and extraction time, as well as desorption temperature and time, were investigated. Analytical parameters such as linearity, repeatability and limit of detection were also evaluated. The inhibition of humic acid to the extraction of chloroacetanilide herbicides was observed. A standard addition method for calibration was recommended to reduce deviations caused by matrix interferences. The proposed method provided a simple and rapid analytical procedure for chloroacetanilide herbicides in water with limits of detection 0.002-0.065 microg/L for deionized water, and 0.005-0.22 microg/L for farm water. The relative standard deviations (n = 5) for analyses of farm water were 7-20% for 5 [corrected] microg/L chloroacetanilide herbicides. This application was illustrated by the analysis of sample collected from farm water in the Chung-hwa area, Taiwan.  相似文献   

12.
A ceramic/carbon composite was developed and applied as a novel coating for solid-phase microextraction (SPME). The ceramic/carbon coating exhibited several good properties for SPME, such as high extraction quantities and enhanced thermal and organic solvent stability. Under scanning electron microscopy (SEM), the tightly attached coating layer on stainless steel wire revealed excellent mechanical characteristics. Single fiber and fiber-to-fiber reproducibility were less than 6.9 and 9.5%, respectively. The effects of extraction and desorption parameters such as extraction time, stirring rate, ionic strength, and desorption temperature and desorption time on the extraction/desorption efficiency were investigated and optimized. Coupled to gas chromatography with a flame thermionic detector, the optimized SPME method was applied to the analysis of organophosphorus pesticides (OPPs) in aqueous samples. The calibration curves were linear from 0.05 to 200 ng mL(-1) for fenchlorphos, pirimiphos-methyl, chlorpyrifos, ethion and from 0.2 to 200 ng mL(-1) for quinalphos, and the limits of detection were between 5.2 and 34.6 ng L(-1). The recovery of the OPPs spiked in real water samples at 5 ng mL(-1) ranged from 86.2 to 103.4% and the relative standard deviations were less than 8.5%.  相似文献   

13.
A solid‐phase microextraction (SPME) fiber coated with poly(methacrylic acid‐ethylene glycol dimethacrylate) coupled to GC with a micro electron‐capture detector was developed for the determination of four chlorphenols in water samples for the first time. A novel and simple method for the preparation of this novel SPME fiber was proposed by copolymerization of methacrylic acid and ethylene glycol dimethacrylate in an appropriate solvent using a glass capillary as a “mold”. The factors affecting the polymerization were optimized in detail. Furthermore, the extraction performance of the poly(methacrylic acid‐ethylene glycol dimethacrylate) fiber was evaluated. Moreover, experimental headspace‐SPME parameters, such as extraction temperature, extraction time, salt concentration, stirring speed, and pH, were optimized by orthogonal array experimental designs. Under the optimized conditions, the target analytes were linear in the range of 0.2–50 ng/mL, and the correlation coefficients were all greater than 0.99. RSD was less than 8.9%, and the detection limits were in the range of 0.1–10 ng/L. Four cholorphenols were detected from tap and lake water samples using the proposed method, with the recoveries of spiked natural water samples were ranged from 91.8 to 110.8, and 90.6 to 111.4% for tap and lake water samples, respectively.  相似文献   

14.
A novel solid-phase microextraction (SPME) method coupled to gas chromatography with electron capture detection (GC-ECD) was developed as an alternative to liquid-liquid and solid-phase extraction for the analysis of short-chain chlorinated paraffins (SCCPs) in water samples. The extraction efficiency of five different commercially available fibres was evaluated and the 100-microm polydimethylsiloxane coating was the most suitable for the absorption of the SCCPs. Optimisation of several SPME parameters, such as extraction time and temperature, ionic strength and desorption time, was performed. Quality parameters were established using Milli-Q, tap water and river water. Linearity ranged between 0.06 and 6 microg l(-1) for spiked Milli-Q water and between 0.6 and 6 microg l(-1) for natural waters. The precision of the SPME-GC-ECD method for the three aqueous matrices was similar and gave relative standard deviations (RSD) between 12 and 14%. The limit of detection (LOD) was 0.02 microg l(-1) for Milli-Q water and 0.3 microg l(-1) for both tap water and river water. The optimised SPME-GC-ECD method was successfully applied to the determination of SCCPs in river water samples.  相似文献   

15.
Feng J  Sun M  Liu H  Li J  Liu X  Jiang S 《Journal of chromatography. A》2010,1217(52):8079-8086
A novel solid-phase microextraction fiber based on a stainless steel wire coated with Au nanoparticles was prepared and has been applied, coupled with gas chromatography, to the extraction of aromatic hydrophobic organic chemical pollutants in rainwater and soil extract. The solid-phase microextraction fiber exhibited excellent extraction efficiency and selectivity. Effects of extraction time, extraction temperature, ionic strength, stirring rate and desorption conditions were investigated and optimized. Single fiber repeatability and fiber-to-fiber reproducibility were less than 7.90% and 26.40%, respectively. The calibration curves were linear in a wide range for all analytes. Correlation coefficients ranged from 0.9941 to 0.9993. The as-established SPME-GC method was used successfully to two real natural samples. Recovery of analytes spiked at 10 μg L(-1) and 100 μg L(-1) ranged from 78.4% to 119.9% and the relative standard deviations were less than 11.3%.  相似文献   

16.
A solid-phase microextraction (SPME) method was applied to an extended monitoring survey of priority pesticides for the European Union for a period of 12 months in water of the Kalamas River (Epirus region of northwestern Greece) in order to determine their concentrations and seasonal variations. Polydimethylsiloxane-coated fiber (100 microm) was used. The samples were screened using gas chromatography with flame thermionic detection. Detection was confirmed by gas chromatographymass spectroscopy. The most frequently detected pesticides were some of the more commonly used herbicides, such as S-ethyl-N,N-di-n-propylthiol carbamate (EPTC), trifluralin, atrazine, deethylatrazine, terbuthylazine and alachlor, and insecticides, such as carbofuran, diazinon, disulfoton, parathion methyl, parathion ethyl, fenthion and ethion. Concentrations of individual compounds ranged from 0.020 to 0.3 microg/L. Greater pesticide concentrations occurred during the seasons of application. A comparison with a well-established solid-phase extraction (C18 disks) procedure was performed for samples of high-season application (May-September) in order to confirm the effectiveness of the SPME technique. The results demonstrate the suitability of the SPME method for routine screening multiresidue analysis in natural waters.  相似文献   

17.
C18-MCM-41新型涂层在固相微萃取中的应用   总被引:2,自引:1,他引:1  
固相微萃取(SPME)是集采样、萃取和富集于一体的样品前处理技术,该技术于1990年由Pawliszyn提出。由于其不使用有机溶剂,且简便、快速、样品用量少,因而,倍受分析工作者的青睐。  相似文献   

18.
采用水热处理和溶胶-凝胶法在镍钛合金(NiTi)纤维表面组装了二氧化硅纳米片(SiO2NFs),成功制备了新型SiO2纤维涂层,并用苯基三氯硅烷进行了自组装表面修饰,得到了可用于固相微萃取(SPME)的NiO/TiO2@SiO2NFs-Ph纤维。将制备的SPME纤维与高效液相色谱联用,通过对典型芳香化合物的分析评价了所制备纤维的萃取性能。该纤维对多环芳烃(PAHs)具有较高的萃取率和良好的萃取选择性。实验优化了pH值、搅拌速率、萃取温度、萃取时间和离子强度对PAHs萃取率的影响。在优化条件下,5种PAHs在各自的范围内呈良好的线性关系,相关系数(r)大于0.999,检出限为0.013~0.108 μg/L。使用单根纤维对含有50 μg/L PAHs的加标水样进行萃取,其含量的日内及日间RSD分别为4.1%~5.9%和4.8%~6.8%。实际环境水样中5种PAHs在10 μg/L和30 μg/L加标水平下的加标回收率分别为90.8%~105.7%和93.6%~103.1%。该法制备的NiO/TiO2@SiO2NFs-Ph纤维稳定性高、制备重现性好,适用于环境水样中目标PAHs的富集和测定。  相似文献   

19.

A method based on solid-phase microextraction and gas chromatography nitrogen-phosphorus detector for the determination of common organonitrogen pesticides (ONPs) in aqueous samples was described. Three kinds of commercially available coated fused-silica fibres were compared: 100 µm PDMS, 85 µm PA, and 65 µm CW-DVB; 65 µm CW-DVB was the most sensitive fibre coating for the analytes' determination. The extraction time, the stirring, the content of salt, and the content of organic solvents were found to have a significant influence on extraction efficiency. The optimised conditions were 65 µm CW-DVB fibre, 40 min extraction time, with rapid stirring and concentration of NaCl was fixed at 0.25 g/mL. The linear range was 0.1-100 µg/L for most of the compounds. The limits of detection (LODs) ranged from 0.02 mg/L (for trifluralin, simazine, terbuthylazine, cyanazine, and pendimethalin) to 0.08 µg/L (for terbutryn) and RSD % of repeatability were for most of the compounds below 10%. Thus the maximum level set by the European Union for pesticides and drinking waters can be verified. The recovery of spiked water samples was compared and validated with the liquid-liquid extraction one. Environmental water samples were analysed and trifluraline was detected.  相似文献   

20.
A high-temperature-resistant solid-phase microextraction (SPME) fiber was prepared based on polyetherimide (PEI) by the electrospinning method. The PEI polymeric solution was converted to nanofibers using high voltages and directly coated on a stainless steel SPME needle. The scanning electron microscopy images of PEI coating showed fibers with diameter range of 500–650 nm with a homogeneous and smooth surface morphology. The SPME nanofibers coating was optimized for PEI percentage, electrospinning voltage, and time. The extraction efficiency of the coating was investigated for headspace SPME of some environmentally important polycyclic aromatic hydrocarbons from aqueous samples followed by gas chromatography–mass spectrometry measurement. In addition, the important extraction parameters including extraction temperature, extraction time, ionic strength, as well as desorption temperature and time were investigated and optimized. The detection limits of the method under optimized conditions ranged from 1 to 5 ng L?1 using time-scheduled selected ion monitoring mode. The relative standard deviations of the method were between 1.1 and 7.1 %, at a concentration level of 500 ng L?1. The calibration curves of polycyclic aromatic hydrocarbons showed linearity in the range of 5–1000 ng L?1. The developed method was successfully applied to real water samples and the relative recovery percentages obtained from the spiked water samples were from 84 to 98 % for all the selected analytes except for acenaphthene which was from 75 to 106 %.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号