首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This work presents the transportation of Li+ ions at the interface of a charging LiCoO2 electrode through the substrate-generation/tip-collection (SG/TC) feedback mode of scanning electrochemical microscopy (SECM). The TC current, due to the reduction of the ethylene carbonate (EC) supermolecule, is collected more strongly at 1.8 V than that of the Li+(DEC) n at 2.5 V near at the substrate because of the increased concentration of the supermolecule Li+(EC)m, which means that the electrolyte is not uniformly distributed over the substrate. The smooth SG/TC current loop is formed at the probe position optimized by the probe scan curve technique between the LiCoO2 substrate with 4.0 V and the probe with 1.8 V, which is applied to analyze the Li+ ion transport at the interface of the LiCoO2 electrode. Moreover, the LiCoO2 substrate, which has a flat surface, is imaged to the nonuniform surface electrochemically by the SECM. We infer that these experimental techniques will help analyze transporting Li+ ions at the interface and the electrochemical uniformity of the electrode.  相似文献   

2.
The electrocatalytic activity of platinum for hydrogen oxidation in 0.01 M H2SO4 + 0.1 MNa2SO4 solution has been investigated by scanning electrochemical microscopy (SECM) technique. The cyclic voltammogram (CV), approach curve, area scan imaging and chronoamperometric methods have been used. The results indicate that the imaging capability of the SECM feedback mode can be used more efficiently to visually identify materials' electrocatalytic activity, compared with the approach curve method for identification of the conductive or insulating nature of a surface. The SECM imaging method has demonstrated the effects of Pt substrate potential on the electrocatalytic oxidation of hydrogen under a constant tip potential. It is found that the more positive the Pt substrate potential, the lower the electrocatalytic activity of the Pt. Furthermore, the chronoamperometric results support the variation of the electrocatalytic activity with the Pt substrate potential as well.  相似文献   

3.
We have studied the micropatterning and characterization of the organic monolayers using cyclic voltammetry (CV), scanning electrochemical microscopy (SECM), atom force microscopy, and AC impedance, and have determined the electrochemical parameters, i.e., the apparent reaction rate constant (K f) and the coverage of the electrode surface (θ). CV and SECM experiments demonstrated that the surface of the modified electrode represents an insulating substrate for ferricyanide. Using the high sensitivity of the electron transfer of ferricyanide to the modification of the gold surface with DNA, we selected this reaction as a probe to study the different modification stages at this modified electrode. SECM images obtained from bare, partially modified, and totally modified electrodes showed very good resolution with different topographies or null according to the extent of modification. Based on a comparison with the results of the experiments, a reasonable agreement can be obtained, which means a conjunction of these techniques.  相似文献   

4.
Titanium and alloys with titanium as the major component are widely used for making biomedical implants, such as artificial dental roots. In our laboratory, we have studied the kinetics of the self-healing reaction of the TiO2 film that forms on the surface of such an implant. Amperometric SECM approach curves were recorded over the surface of a grade 4 titanium (Ti G4) dental implant sample at specific times after the metal surface had been exposed to an air-saturated buffer solution. A ferrocene methanol redox mediator and a platinum microelectrode tip (r = 12.5 μm) were used in the experiments. The effective rate coefficient (keff) values for the mediator regenerating surface reaction were estimated using Wittstock's method from the approach curves recorded at different time points. Decreasing values of keff over time indicated an increasing rate of formation of the passivating TiO2 film.  相似文献   

5.
In this study, the effects of forced convection on scanning electrochemical microscopy (SECM) experiments in feedback mode using ferrocenemethanol as redox mediator are presented. Forced convection, which enhances the mass transfer inside the system, was generated via an electrical high precision stirrer integrated into the SECM setup. A thin‐film interdigitated array electrode serving as model substrate was investigated with probe scan curves in z‐direction and SECM imaging in constant height mode utilizing ultramicroelectrodes (UME) with diameters (dprobe) of 25 μm and 12.5 μm. It was found that forced convection increased the overall current during SECM imaging without distorting distinctive features of the imaged structure when working with a 25 μm UME at substrate‐to‐tip distances of 14 μm and 11 μm. Furthermore, the electrochemical contrast was improved under hydrodynamic conditions for a substrate‐to‐tip distance of 11 μm and scan rates of 5 μm s?1, 10 μm s?1, 20 μm s?1 and 40 μm s?1. When further decreasing the gap between the UME and the substrate to 9 μm almost no effects of the forced convection were observed. Consequently, for a 25 μm UME, forced convection led to higher currents and improved performance during SECM experiments in feedback mode at substrate‐to‐tip distances of 14 μm and 11 μm, whereas no effects were observed for a 12.5 μm UME at a distance of 8 μm.  相似文献   

6.
Lanlan Zhu  Wenrui Jin 《Talanta》2008,77(2):804-808
Scanning electrochemical microscopy (SECM) is a powerful tool to examine the respiratory activity of living cells. However, in SECM measurements of cell respiratory activity, the signal recorded usually also includes the signal corresponding to the cell topography. Therefore, measurements of cell respiratory activity using conventional SECM techniques are not accurate. In the present work, we develop a method for accurate measurement of the respiratory activity of single living cells using SECM. First, cells are immobilized on a glass substrate modified with collagen. Then, a Pt ultramicroelectrode tip of SECM held at −0.50 V is scanned along the central line across a living cell and a SECM scan curve, i.e., the relationship of the tip current versus the displacement (the first scan curve) is recorded with a negative peak. The peak current ip on this first scan curve is composed of ip1, which corresponds to the cell respiratory activity and ip2, which corresponds to the cell topography. In order to isolate the ip2 component, the cell is killed by exposing it to 1.0 × 10−3 mol/L KCN for 10 min. The tip is then scanned again with the same trace over the dead cell, and a second SECM scan curve is recorded. Noting that the topography of the dead cell is the same as that of the living cell, this second scan curve with a negative peak corresponds now only to the cell topography. Thus, ip2 is obtained from the second SECM scan curve. Finally, ip1 corresponding to the respiratory activity of the living cell can be accurately calculated using ip1 = ip − ip2. This method can be used to monitor real-time change in the respiratory activity of single cells after exposing them to KBr, NaN3 and KCN.  相似文献   

7.
A voltammetric and scanning electrochemical microscopy (SECM) investigation was performed on an inherently chiral oligomer-coated gold electrode to establish its general properties (i.e., conductivity and topography), as well as its ability to discriminate chiral electroactive probe molecules. The electroactive monomer (S)-2,2′-bis(2,2′-bithiophene-5-yl)-3,3′-bibenzothiophene ((S)-BT2T4) was employed as reagent to electrodeposit, by cyclic voltammetry, the inherently chiral oligomer film of (S)-BT2T4 (oligo-(S)-BT2T4) onto the Au electrode surface (resulting in oligo-(S)-BT2T4-Au). SECM measurements, performed in either feedback or competition mode, using the redox mediators [Fe(CN)6]4− and [Fe(CN)6]3− in aqueous solutions, and ferrocene (Fc), (S)-FcEA, (R)-FcEA and rac-FcEA (FcEA is N,N-dimethyl-1-ferrocenylethylamine) in CH3CN solutions, indicated that the oligomer film, as produced, was uncharged. The use of [Fe(CN)6]3− allowed establishing that the oligomer film behaved as a porous insulating membrane, presenting a rather rough surface. This was inferred from both the approach curves and linear and bidimensional SECM scans, which displayed negative feedback effects. The oligomer film acquired semiconducting or fully conducting properties when the Au electrode was biased at potential more positive than 0.6 V vs. Ag|AgCl|KCl. Under the latter conditions, the approach curves displayed positive feedback effects. SECM measurements, performed in competition mode, allowed verifying the discriminating ability of the oligo-(S)-BT2T4 film towards the (S)-FcEA and (R)-FcEA redox mediators, which confirmed the results obtained by cyclic voltammetry. SECM linear scans indicated that the enantiomeric discriminating ability of the oligo-(S)-BT2T4 was even across its entire surface.  相似文献   

8.
Electrochemical detection of H2 using scanning electrochemical microscopy (SECM) has shown to hold great promise as a sensitive characterization method with high spatial resolution for active surfaces generating H2. Herein, the factors contributing to the current that is measured by SECM in generation/collection mode for H2 detection are studied. In particular, the concentration gradient of H2 at the substrate, the H2/H+ recycling between the SECM tip and substrate and hemispherical profile of H2 diffusion has been discussed. It was postulated that H2/H+ recycling plays a dominant role in the oxidative current measured in generation/collection mode of SECM when the microelectrode is positioned in close vicinity of substrate. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

9.
Scanning electrochemical microscopy (SECM) was used to monitor in situ hydrogen peroxide (H2O2) produced at a polarized water/1,2-dichloroethane (DCE) interface. The water/DCE interface was formed between a DCE droplet containing decamethylferrocene (DMFc) supported on a solid electrode and an acidic aqueous solution. H2O2 was generated by reducing oxygen with DMFc at the water/DCE interface, and was detected with a SECM tip positioned in the vicinity of the interface using a substrate generation/tip collection mode. This work shows unambiguously how the H2O2 generation depends on the polarization of the liquid/liquid interface, and how proton-coupled electron transfer reactions can be controlled at liquid/liquid interfaces.  相似文献   

10.
The fabrication of a gold microelectrode modified with iridium oxide film (IrOx) and its use as tip with a dual function in SECM experiments is reported. The defective structure of the coating onto the microelectrode surface was used as strategy to combine the advantages of both amperometric (for current‐distance determination) and potentiometric (for pH sensing) SECM operation modes. Approach curves, using oxygen and hexaammineruthenium(III) as redox mediators, were obtained without significant loss of the performance and reproducibility of the potentiometric pH response. This allowed the precise positioning of the proposed tip above a substrate in SECM experiments and, subsequently, to monitor pH at the substrate surface. The IrOx modified microelectrode was applied successfully in SECM experiments involving the local proton consumption during the nitrate reduction at a copper cathode surface.  相似文献   

11.
研究病变细胞和组织的异常表现可为理解重大疾病发生发展的病理机理和新型药物筛选提供重要参考.扫描电化学显微镜(Scanning electrochemical microscopy, SECM)是一种基于电化学原理的扫描探针显微镜,通过记录探针在样品表面扫描时的电流或电位等信息,对活细胞的形态和多种化学信息进行原位、实时...  相似文献   

12.
Herein, the scanning electrochemical microscopy (SECM) approach is applied to study the formation of thiol-porphyrin self-assembled monolayer (SAMs). Using cyclic voltammetry (CV), the formation process is characterized adopting different probe molecules. The observed phenomena indicate that the formation process is affected by solution properties and the molecular structure of the probe molecules. In K(3)Fe(CN)(6) , the SAMs show a strong electron-transfer (ET) blocking effect on a pure porphyrin-modified electrode. However, addition of metal ions to the porphyrin molecules leads to ET. A consistent tendency is observed throughout the modification process using CV and SECM methods. Furthermore, k(eff) values, the apparent heterogeneous rate constants, obtained for different modification periods affirm the validity of these results. SECM images are used to collect surface information in the course of the modification process when the substrate potential is 0.5 V versus Ag/AgCl. The effect of the substrate potential indicates that the oxidation of the porphyrin molecules is supported by more positive potentials because of the similar bimolecular reaction of the porphyrin ring with positive charge and the probe molecules with negative charge.  相似文献   

13.
We used a new reactive species OH? to fabricate active horseradish peroxidase (HRP) micropatterns with a high resolution by scanning electrochemical microscopy (SECM) coupled with a carbon fiber disk electrode as the SECM tip. In this method, except for active HRP micropatterns predesigned other regions on a HRP‐immobilized substrate were deactivated by OH? generated at the tip held at ?1.7 V in 1.0 mol/L KCl containing 2.0×10?3 mol/L benzoquinone (BQ) (pH 8.0). The feedback mode of SECM with a tip potential of ?0.2 V was used to characterize the active HRP micropatterns in 1.0 mol/L KCl containing 2.0×10?3 mol/L BQ and 2.0×10?3 mol/L H2O2.  相似文献   

14.
《Electroanalysis》2017,29(6):1532-1542
Glucose oxidase (GOx) is an enzyme, which is used for the development of enzymatic biofuel cells. Therefore in this research redox competition mode of scanning electrochemical microscopy (RC‐SECM) was applied for the investigation of glucose oxidase (GOx) catalyzed reaction kinetics. The GOx was immobilized by glutaraldehyde on substrates of different electrical conductivity: (i) gold covered glass was used as conducting substrate and (ii) plastic poly(methyl methacrylate) was used as non‐conducting substrate. Current vs distance dependencies were registered by SECM at different concentrations of glucose in the absence of redox mediator. The potential of −750 mV vs Ag/AgCl(3 M KCl) was applied to the microelectrode (ME), which was used as a probe in SECM, in order to register oxygen reduction current. Consumption of oxygen by the GOx based layer was evaluated according to principles determined by Michaelis‐Menten kinetics. Apparent Michaelis constants K M (app.) were calculated from the dependencies of current vs glucose concentration. In both these cases the K M (app.) value increased when the distance between ME and enzyme modified surface was increasing from 10 to 30 μm, while the K M (app.) value decreased by increasing the distance from 30 to 60 μm.  相似文献   

15.
Pt microelectrodes (50 μm diameter) were positioned by means of scanning electrochemical microscopy assisted z-approach curves and in situ modified with nickel tetrasulfonated phthalocyanine tetrasodium salt as electrocatalytic layer for the specific oxidative detection of nitric oxide. The thus modified electrodes were then moved over a layer of adherently growing human umbilical vein endothelial cells (HUVEC) in order to amperometrically detect nitric oxide (NO) released from the cells upon stimulation with bradykinin. This approach actually takes advantage of the use of SECM to define a sequential procedure that enables the in situ functionalisation of the SECM tip thus allowing to accurately control the separation between the functionalised SECM tip and the cell population.  相似文献   

16.
Scanning electrochemical microscopy (SECM) was employed for sensitive detection of single base mismatches (SBMs) in a sandwiched dsDNA. Ferrocenecarboxylic acid (Fc), covalently conjugated to the dsDNA, was oxidized to Fc+ via the DNA‐mediated charge transfer from the underlying gold substrate, and reduced back to Fc by SECM tip generated ferrocyanide. The electrocatalytic oxidation of SECM tip‐generated ferrocyanide was sensitive to presence, as well as the type of SBMs. Apparent standard rate constants (k0app) values for different SBMs, both near the electrode surface and far from it, were evaluated by SECM. The method can detect SBMs independent of their position in dsDNA.  相似文献   

17.
18.
Local ion activity changes in close proximity to the surface of an oxygen depolarized cathode (ODC) were measured by scanning electrochemical microscopy (SECM). While the operating ODC produces OH? ions and consumes O2 and H2O through the electrocatalytic oxygen reduction reaction (ORR), local changes in the activity of OH? ions and H2O are detected by means of a positioned Pt microelectrode serving as an SECM tip. Sensing at the Pt tip is based on the pH‐dependent reduction of PtO and obviates the need for prior electrode modification steps. It can be used to evaluate the coordination numbers of OH? ions and H2O, and the method was exploited as a novel approach of catalyst activity assessment. We show that the electrochemical reaction on highly active catalysts can have a drastic influence on the reaction environment.  相似文献   

19.
 An investigation of an array of four Pt microband electrodes 25 μm wide and spaced 25 μm apart was performed with the scanning electrochemical microscope (SECM). Where possible the SECM measurements were confirmed with conventional electrochemical measurements. It is shown how the sensiti- vity of the SECM recycling current to the activity of the underlying surface can be used to probe the homogeneity of enzyme-modified microelectrodes. The diffusion of H2O2 between these micro enzyme- electrodes and unmodified electrodes was investigated and it was demonstrated how the SECM can be a powerful tool in the elucidation of the properties of these electrodes. Received June 8, 1998. Revision November 12, 1998.  相似文献   

20.
We report on the surface micropatterning of conductive surfaces via the electrochemical triggering of a click reaction, the copper(I) catalyzed azide–alkyne cycloaddition reaction (CuAAC) by SECM via a two-step approach: (i) functionalization on the entire surface with azido-aryl groups by using the diazonium approach followed by (ii) the covalent linkage of alkyne-bearing ferrocene by CuAAC within a local area by SECM. More precisely, the click reaction was triggered by Cu(I) catalyst generation for 30 min at the SECM tip positioned ≈ 10 μm above the azido-aryl modified surface. The dimension of the spot obtained under these conditions was ≈ 75 μm. The electrochemical imaging by SECM of the ultra thin area locally clicked with ferrocene moieties was made thanks to the electrocatalytic properties of the ferrocene modified surface towards ferrocyanide electrooxidation. This local clicking procedure opens the gate to further controlled functionalization of restricted small substrates.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号