首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
On-line coupling between CIEF and ESI/MS based on the use of bare fused-silica capillaries and glycerol-water media, recently developed in our laboratory, has been investigated for the separation of milk whey proteins that present close pI values. First, a new rinsing procedure, compatible with MS detection, has been developed to desorb these rather hydrophobic proteins (α-casein (α-CN), bovine serum albumin (BSA), lactoferrin (LF)) from the inner capillary wall and to avoid capillary blockages. Common hydrochloric acid washing solution was replaced by a multi-step sequence based on the use of TFA, ammonia and ethanol. To achieve the separation of major whey proteins (β-lactoglobulin A (β-LG A), β-lactoglobulin B (β-LG B), α-lactalbumin (α-LA) and BSA, which possess close pI values (4.5-5.35), CIEF parameters i.e. carrier ampholyte nature, capillary partial filling length with ampholyte/protein mixture and focusing time, have been optimized with respect to total analysis time, sensitivity and precision on pI determination. After optimization of sheath liquid composition (80:20 (v/v) methanol-water+1% HCOOH), quantitation of β-LG A, β-LG B, α-LA and BSA was performed. The limits of detection obtained from extracted ion current (EIC) and single ion monitoring (SIM) modes were in the 57-136 nM and 11-68 nM range, respectively. Finally, first results obtained from biological samples demonstrated the suitability of CIEF-MS as a potential alternative methodology to 2D-PAGE to diagnose milk protein allergies.  相似文献   

2.
Two capillary isoelectric focusing (CIEF) systems have first been optimized: one uses a bare silica capillary and 30% (v/v) of glycerol in the separation medium while the other uses a coated capillary and an aqueous background electrolyte. To perform permanent capillary coating, two neutral polymers have been compared: hydroxypropylcellulose (HPC) and polyvinylalcohol (PVA). HPC coating gave best results for electroosmotic flow (EOF) limitation on a wide pH range: as compared to a bare silica capillary, it allowed to decrease EOF by 96% at pH 7.2 after acidic and basic treatments, whereas PVA coating lead only to a 76% decrease. The glycerol CIEF system was more satisfying for the separation of model proteins classically used as pI markers. Finally, the use of "narrow pH cuts" of carrier ampholytes added to commercial ampholyte mixtures allowed increasing resolution up to a factor 2.4 at a chosen pH for the separation of pI markers and milk proteins.  相似文献   

3.
The use of quasi-isoelectric anolytes and catholytes has been investigated to improve CIEF performances. Narrow pH cuts of carrier ampholytes (NC) have been compared to more conventional couples of anolytes/catholytes (phosphoric acid/sodium hydroxide and glutamic acid/lysine). First, a CIEF setup that consists in a bare silica capillary and 70:30 water/glycerol separation medium has been used. The experiments have shown that when using NC instead of more classical anolytes and catholytes, an increase in the protein detection time was observed and the resolutions obtained for neutral and acidic proteins were doubled. Moreover, according to the NC fraction used, the resolution was modified. In order to investigate further the mechanisms involved, a second setup using a capillary coated with hydroxypropylcellulose was used. With this setup no difference has been observed when changing anolyte and catholyte nature. A simple methodology has then been developed to evaluate EOF during focusing and mobilization steps of CIEF experiments. It highlighted the crucial role played by EOF when using a bare silica capillary. EOF indeed decreased by 33% during mobilization step when using NC instead of classical anolytes and catholytes.  相似文献   

4.
Cao F  Luo Z  Zhou D  Zeng R  Wang Y 《Electrophoresis》2011,32(10):1148-1155
In this work, a novel graft copolymer, hydroxyethylcellulose-graft-poly(2-(dimethylamino)ethyl methacrylate) (HEC-g-PDMAEMA), used as physical coatings of the bare fused-silica capillaries, was synthesized by using ceric ammonium nitrate initiator in aqueous nitric acid solution. EOF measurement results showed that the synthesized HEC-g-PDMAEMA graft copolymer-coated capillary in this paper could suppress EOF effectively compared to the bare fused-silica capillary, and efficient separations of basic proteins were also achieved. The electrical charge of the coated capillary wall could be modulated by varying not only the pH of the running buffer, but also the grafting ratio of poly(2-(dimethylamino)ethyl methacrylate) grafts, which makes possible the analysis of basic and acidic proteins in the same capillary. The effects of poly(2-(dimethylamino)ethyl methacrylate) grafting ratio in HEC-g-PDMAEMA and buffer pH on the separation of basic proteins for capillary electrophoresis were investigated in detail. Furthermore, egg white proteins and milk powder samples were separated by the HEC-g-PDMAEMA-coated capillary. The results demonstrated that the HEC-g-PDMAEMA copolymer coatings have great potential in the field of diagnosis and proteomics.  相似文献   

5.
To stabilize electroosmotic flow (EOF) and suppress protein adsorption onto the silica capillary inner wall, a cationic hydroxyethylcellulose-graft-poly (poly(ethylene glycol) methyl ether methacrylate) (cat-HEC-g-PPEGMA) graft copolymer composed of cationic backbone and bottle brush-like side chains was synthesized for the first time and used as a novel physically adsorbed coating for protein separation by capillary electrophoresis. Reversed (anodal) and very stable EOF was obtained in cat-HEC-g-PPEGMA-coated capillary at pH 2.2-7.8. The effects of degree of cationization, PEGMA grafting ratio, PEGMA molecular mass, and buffer pH on the separation of basic proteins were investigated. A systematic comparative study of protein separation in bare and HEC-coated capillaries and in cat-HEC-g-PPEGMA-coated capillary was also performed. The basic proteins can be well separated in cat-HEC-g-PPEGMA-coated capillary over the pH range of 2.8-6.8 with good repeatability and high separation efficiency, because the coating combines good protein-resistant property of bottle brush-like PPEGMA side chains with excellent coating ability of cat-HEC backbone. Besides its success in separation of basic proteins, the cat-HEC-g-PPEGMA coating was also superior in the fast separation of other protein samples, such as protein mixture, egg white, and saliva, which indicates that it is a promising coating for further proteomics analysis.  相似文献   

6.
A new application of the polymeric ionic liquid (PIL) in capillary electrophoresis is reported. Poly(1-vinyl-3-butylimidazolium bromide) was physically adsorbed on silica capillary as the simple and effective coating for capillary electrophoresis (CE) analysis, in which the PIL is not present in the background electrolyte. The electroosmotic flow (EOF) of the PIL-coated capillary as compared with that of the bare fused-silica capillary shows a different dependence on electrolyte pH values. The EOF is reversed over a wide pH range from 3.0 to 9.0 and shows good repeatability. It is also found that the coated capillary has a good tolerance to some organic solvents, 0.1 M NaOH and 0.1 M HCl. The PIL-coated capillary has been employed in different areas. Both the basic proteins and anionic analytes can be well separated by PIL-coated capillaries in a fast and easy way. The PIL-coated capillary is also able to separate organic acid additives in a grape juice. The results showed that this type of coating provides an alternative to the CE separation of anions and basic proteins.  相似文献   

7.
In this study, bare gold nanoparticles (GNPs) immobilized in the sol-gel-pretreated fused-silica (FS) capillary as a stationary phase for open-tubular capillary electrochromatography (OT-CEC) are for the first time shown to be able to separate both hydrophobic polyaromatic hydrocarbons (PAHs) as well as hydrophilic cationic antimicrobial peptides. Model mixture of four PAHs, naphthalene, fluorene, phenanthrene, and anthracene, was resolved by OT-CEC in the GNP-modified FS capillaries using the hydro-organic background electrolyte (BGE) composed of 20 mmol/L sodium phosphate buffer, pH 7, modified with ACN at 8:2 v/v ratio. On the other hand, three synthetic analogues of an antimicrobial peptide mastoparan PDD-B, basic tetradecapeptides INWKKLGKKILGAL-NH(2), INSLKLGKKILGAL-NH(2) and NWLRLGRRILGAL-NH(2), were separated in aqueous acidic BGEs, pH 2.1-3.1, composed of weak acids (formic and acetic) or amphoteric amino or imino acids (aspartic or iminodiacetic), utilizing the advantage of a slow reversed (anodic) EOF and slightly positive charge of the GNP-modified FS capillary suppressing the adsorption of cationic peptides on the inner capillary wall and improving their resolution.  相似文献   

8.
We examined the elution behavior of isoluminol isothiocyanate (ILITC)-labeled biomolecules (α-amino acids, peptides, and proteins) in an open-tubular capillary chromatography system using an untreated fused-silica capillary tube and a water-acetonitrile-ethyl acetate mixture carrier solution. Such an open-tubular capillary chromatography is called "tube radial distribution chromatography (TRDC)" for convenience. A mixture of ILITC and ILITC-labeled biomolecules was analyzed using TRDC with chemiluminescence detection that provided simple instrument without a light source and complex optical devises. The ILITC and the labeled twenty α-amino acids were separated, in this order or the reverse order, or not separated with an organic solvent-rich and water-rich carrier solution. Their elution behavior was considered to be of hydrophilic or hydrophobic nature of ILITC and the labeled α-amino acids. The ILITC and the labeled protein, alcohol dehydrogenase and bovine serum albumin, were separated in this order with an organic solvent-rich carrier solution, while they were eluted in the reverse order with a water-rich carrier solution, based on the TRDC separation performance. The TRDC system worked with the untreated open-tubular capillary tube not using any specific capillary tubes, such as coated, packed, or monolithic.  相似文献   

9.
Wu J  Pawliszyn J 《Talanta》1992,39(10):1281-1288
A robust, inexpensive and versatile capillary electrophoresis (CE) system for routine and rapid analysis is reported, which consists of a rugged cartridge holding a 20-mum i.d. 15-cm long capillary, and an inexpensive, universal and sensitive concentration gradient detector. The design of the cartridge simplifies the sample introduction process and makes it possible to perform many separation modes, including moving boundary capillary electrophoresis (MBCE), capillary zone electrophoresis (CZE), capillary isotachophoresis (CITP) and capillary isoelectric focusing (CIEF), on the same system. This arrangement provides more information about a sample's components since analytes can be separated by different modes performed on the same CE system. The detector only consists of a low-power HeNe laser, or laser diode, and a photodiode position sensor. Amino acids and proteins of 10(-6)-10(-3)M concentration can be separated by different capillary electrophoretic modes, and detected directly by the detector. The universal detector shows particularly good sensitivity when applied to CE separation modes having self-concentration and focusing effects. Femtomoles of proteins were separated and detected with CIEF. In addition, a short and narrow capillary allows use of high electrical fields which facilitate rapid separations. Four amino acids at millimolar concentrations were fully separated and detected in less than 80 sec by the MBCE mode when a high electric field was applied. The physical size of the whole system is much smaller than that of conventional CE instruments with UV absorbance or fluorescence detector.  相似文献   

10.
An integrated platform consisting of protein separation by CIEF with monolithic immobilized pH gradient (M‐IPG), on‐line digestion by trypsin‐based immobilized enzyme microreactor (trypsin‐IMER), and peptide separation by CZE was established. In such a platform, a tee unit was used not only to connect M‐IPG CIEF column and trypsin‐IMER, but also to supply adjustment buffer to improve the compatibility of protein separation and digestion. Another interface was made by a Teflon tube with a nick to couple IMER and CZE via a short capillary, which was immerged in a centrifuge tube filled with 20 mmol/L glutamic acid, to exchange protein digests buffer and keep electric contact for peptide separation. By such a platform, under the optimal conditions, a mixture of ribonuclease A, myoglobin and BSA was separated into 12 fractions by M‐IPG CIEF, followed by on‐line digestion by trypsin‐IMER and peptide separation by CZE. Many peaks of tryptic peptides, corresponding to different proteins, were observed with high UV signals, indicating the excellent performance of such an integrated system. We hope that the CE‐based on‐line platform developed herein would provide another powerful alternative for an integrated analysis of proteins.  相似文献   

11.
Liposome capillary electrophoresis (LCE) using unilamellar liposomes composed of the zwitterionic phospholipid 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC) as a suspended pseudo stationary phase has been investigated for its capability at separating peptides and proteins in bare fused-silica capillaries. The study has explored different strategies for allowing the liposome suspension to act as a disperse pseudo stationary phase with the ability of modulating selectivity, resolution and separation performance of peptides and proteins in bare-fused silica capillaries. Such strategies comprise the use of capillaries either partially or totally filled with the liposome suspension, whereas the electrolyte solution is liposome-free, or the incorporation of the liposomes into the buffer solution employed for rinsing the capillary and as the background electrolyte. Three synthetic peptides of similar amino acid sequence and four basic standard proteins have been employed as test analytes. Varying the volume of the liposome suspension introduced in the capillary promoted differentiated variations in the migration velocity of the three peptides reflecting their selective interactions with the liposomes. Efficient separation of basic proteins was obtained at pH 7.4 in a bare fused-silica capillary with the electrolyte solution containing 60 μM POPC.  相似文献   

12.
A brush-like copolymer consisting of poly(ethylene glycol) methyl ether methacrylate and N,N-dimethylacrylamide (PEGMA-DMA) was synthesized and used as a novel static physically adsorbed coating for protein separation by capillary electrophoresis for the first time, in order to stabilize electroosmotic flow (EOF) and suppress adsorption of proteins onto the capillary wall. Very stable and low EOF was obtained in PEGMA-DMA-coated capillary at pH 2.2-7.8. The effects of molar ratio of PEGMA to DMA, copolymer molecular mass, and pH on the separation of basic proteins were discussed. A comparative study of bare capillary with PEGMA-DMA-coated capillary for protein separation was also performed. The basic proteins could be well separated in PEGMA-DMA-coated capillary over the investigated pH range of 2.8-6.8 with good repeatability and high separation efficiency because the copolymer coating combines good protein-resistant property of PEG side chains with excellent coating ability of PDMA-contained backbone. Finally, the coating was successfully applied to the fast separation of other protein samples, such as protein mixture and egg white, which reveals that it is a potential coating for further proteomics analysis.  相似文献   

13.
A high performance liquid chromatography system, a sample preparation device, and an imaged capillary IEF (CIEF) instrument are integrated and multiplexed on-line. The system is equivalent to two-dimensional polyacrylamide gel electrophoresis (2-D PAGE), by transferring the principle of 2-D separation to the capillary format. High performance liquid chromatography (HPLC) provides protein separation based on size using a gel filtration chromatography (GFC) column. Each eluted protein is sampled and directed to a novel microdialysis hollow fiber membrane device, where simultaneous desalting and carrier ampholyte mixing occurs. The sample is then driven to the separation column in an on-line fashion, where CIEF takes place. The fluidic technology used by our 2-D system leads to natural automation. The coupling of the two techniques is simple. This is attributed to high speed and efficiency of the sample preparation device that acts as an interface between the two systems, as well as the speed and simplicity of our whole column absorption imaged CIEF instrument. To demonstrate the feasibility of this approach, the separation of a mixture of two model proteins is studied. Sample preparation and CIEF were complete in just 4-5 min, for each of the eluted proteins. Total analysis time is about 24 min. Three-dimensional data representations are constructed. Challenges and methods to further improve our instrument are discussed, and the design of an improved horseshoe-shaped sample preparation sample loop membrane interface is presented and characterized.  相似文献   

14.
Graf M  Wätzig H 《Electrophoresis》2004,25(17):2959-2964
Capillary isoelectric focusing (CIEF) is an important tool for the quality assurance of biotechnologically maintained drugs and for proteome analysis. The critical performance parameters of this technique are the precisions of isoelectric point (pI) values and peak areas. Compared to capillary zone electrophoresis (CZE), where precise results can be obtained (e.g., 0.5% relative standard deviation (RSD) for peak areas, n = 60), only few data are available for CIEF experiments. So far, reproducible data of pI values (RSD = 0.5%) have been acquired, but peak areas show inferior results (about 3-15% RSD). Nonstable capillary coatings and protein adsorption have been discussed as possible reasons. Recent work of Righetti et al. [25, 27] has proven that the use of coated capillaries can reduce the adsorption of proteins by 50% but cannot prevent it. In our CIEF experiments irregular and poorly reproducible peak patterns have been observed. In a long-time experiment of 106 repeated runs, an overall RSD of 10% was obtained for peak areas, RSD of 2% only in series of about 10 consecutive replicates. Especially at higher concentrations the reproducibility deteriorates. This seems to be the result of a self-amplifying process, induced by adsorbed protein molecules, leading to further agglomerations. CZE control experiments in linear polyacrylamide (LPA)-coated capillaries proved a strong pH dependency of these effects within a small range. Compared to bare fused-silica surfaces, adsorption effects are reduced but not inhibited. An enhancement of reproducibility in CIEF experiments can be achieved only by controlling the interactions of proteins and capillary walls.  相似文献   

15.
A new set-up was constructed for capillary isoelectric focusing (CIEF) involving a sampling capillary as a bypass fixed to the separation capillary. Sample solutions were subjected to a previously established pH gradient from the sample capillary. Besides performing conventional CIEF, the separation of ampholytic compounds with isoelectric points (p/s) beyond the pH gradient was carried out on this system. This method was termed as pH gradient driven electrophoresis (PGDE) and the basic mathematical expressions were derived to express the dynamic fundamentals. Proteins such as lysozyme, cytochrome C, and pepsin with p/s higher than 10 or below 3 were separated in a pH gradient provided by Pharmalyte (pH 3-10). Finally, this protocol convincingly exhibited its potential in the separation of a solution of chicken egg white.  相似文献   

16.
The separation of the basic drug lidocaine and six of its metabolites has been investigated both by using volatile aqueous electrolyte system, at low pH and by employing non-aqueous electrolyte systems. In aqueous systems, the best separation of the compounds under the investigated conditions was achieved by using the electrolyte 60 mM trifluoroacetic acid (TFA)/triethylamine (TEA) at pH 2.5 containing 15% methanol. With this electrolyte, all seven compounds were well separated with high efficiency and migration time repeatability. The separations with bare fused-silica capillaries and polyacrylamide-coated capillaries were compared with higher separation efficiency with the latter. On the other hand, near baseline separation of all the seven compounds was also obtained by employing the non-aqueous electrolyte, 40 mM ammonium acetate in methanol and TFA (99:1, v/v), with comparable migration time repeatability but lower separation efficiency relative to the aqueous system.  相似文献   

17.
The surface properties of novel stationary phases in packed and open tubular columns for capillary electrochromatography (CEC) were examined by measuring the streaming potential in a home made apparatus. The surfaces investigated include materials such as porous styrenic sorbents and octadecyl-silica as well as fused-silica tubing, in both raw and surface modified forms. Functionalization of the surface was carried out, for instance, by reductive amination or organosilane grafting on to capillary inner wall. The dependence of the streaming potential on pH was examined with aqueous solutions in the pH range from 2.5 to 9.0. Electrokinetic properties of 50 microm I.D. fused-silica capillaries have been determined by both streaming potential and electrosmotic flow measurements. Both methods gave similar pH profiles of the zeta-potential and the isoelectric points. This confirms the viability of our approach to evaluate the specific charged groups of the packing which is one of the important factors influencing electrosmotic flow (EOF) velocity and protein adsorption during a chromatographic run. In addition to bare silica capillaries, styrenic monolithic columns with different surface functionalities, which have been extensively used in our laboratory for CEC separation of peptides and proteins, were employed for comparison of two methods. Plots of zeta potential as a function of percent ACN show a complex behavior, indicating that zeta potential cannot be predicted simply from binary mixture solvent properties. It is demonstrated that the evaluation of the zeta potential by the streaming potential method is nondestructive, relatively fast, without untoward effects introduced by Joule heating and yet another means for the characterization of the surfaces under conditions employed in CEC.  相似文献   

18.
Wang T  Ma J  Wu S  Yuan H  Zhang L  Liang Z  Zhang Y 《Electrophoresis》2011,32(20):2848-2856
An integrated platform with the combination of protein and peptide separation was established via online protein digestion, by which proteins were first separated by CIEF, online digested by a trypsin immobilized enzyme microreactor, trapped and desalted by two parallel trap columns, separated by nanoreversed-phase and finally identified by MS. In such a platform, two hollow fiber membrane interfaces were used. One was applied to supply catholyte and electric contact, and another to supply adjustment buffer to improve the compatibility of protein separation and tryptic digestion. A poly(octadecyl acrylate-co-ethylene dimethacrylate) monolithic column served as the trap column to capture sample and to remove the ampholytes from CIEF. A hybrid silica monolith-based immobilized trypsin microreactor was used for online protein digestion. To evaluate the performance of such a platform, a 4-protein mixture with a loading amount of only 0.29?μg, was analyzed, and sequence coverages for BSA, myoglobin, β-lactoglobulin and ribonuclease A were 8, 26, 10 and 54%, respectively. Furthermore, such an integrated platform was successfully applied for the analysis of proteins extracted from Escherichia coli, and 101 proteins were positively identified. We anticipate that the integrated platform developed herein will provide a promising tool for low-abundance protein identification with the combination of top-down and bottom-up approaches.  相似文献   

19.
Mao Y  Zhang X 《Electrophoresis》2003,24(18):3289-3295
A comprehensive two-dimensional (2-D) separation system, coupling capillary reverse-phase liquid chromatography (cRPLC) to capillary isoelectric focusing (CIEF), is described for protein and peptide mapping. cRPLC, the first dimension, provided high-resolution separations for salt-free proteins. CIEF, the second dimension with an orthogonal mechanism to cRPLC afforded excellent resolution capability for proteins with efficient protein enrichment. Since all sample fractions in cRPLC effluents could be transferred to the CIEF dimensions, the combination of the two high-efficiency separations resulted in maximal separation capabilities of each dimension. Separation effectiveness of this approach was demonstrated using complex protein/peptide samples, such as yeast cytosol and a BSA tryptic digest. A peak capacity of more than 10 000 had been achieved. A laser-induced fluorescence (LIF) detector, developed for this system, allowed for high-sensitive detection, with a fmol level of peptide detection for the BSA digest. FITC and BODIPY maleimide were used to tag the proteins, and the latter was found better both for separation and detection in our 2-D system.  相似文献   

20.
Quasi‐interpenetrating network (quasi‐IPN) of linear polyacrylamide (LPA) with low molecular mass and poly(N,N‐dimethylacrylamide) (PDMA), which is shown to uniquely combine the superior sieving ability of LPA with the coating ability of PDMA, has been synthesized for application in dsDNA and basic protein separation by CE. The performance of quasi‐IPN on dsDNA separation was determined by polymer concentration, electric field strength, LPA molecular masses and different acrylamide (AM) to N,N‐dimethylacrylamide (DMA) ratio. The results showed that all fragments in Φ×174/HaeIII digest were achieved with a 30 cm effective capillary length at –6 kV at an appropriate polymer solution concentration in bare silica capillaries. Furthermore, EOF measurement results showed that quasi‐IPN exhibited good capillary coating ability, via adsorption from aqueous solution, efficiently suppressing EOF. The effect of the buffer pH values on the separation of basic proteins was investigated in detail. The separation efficiencies and analysis reproducibility demonstrated the good potentiality of quasi‐IPN matrix for suppressing the adsorption of basic proteins onto the silica capillary wall. In addition, when quasi‐IPN was used both as sieving matrix and dynamic coating in bare silica capillaries, higher peak separation efficiencies, and better migration time reproducibility were obtained.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号