首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The analysis of monoclonal antibodies glycosylation is a crucial quality control attribute of biopharmaceutical drugs. High throughput screening approaches for antibody glycoform analysis are required in various stages of process optimization. Here, we present high throughput screening suitable mass spectrometry-based workflows for the analysis of intact antibody glycosylation out of cell supernatants. Capillary electrophoresis and liquid chromatography were coupled with quadrupole time-of-flight mass spectrometry or Orbitrap mass spectrometry. Both separation methods offer fast separation (10–15 min) and the capability to prevent the separated cell supernatant matrix to enter the mass spectrometry by post-separation valving. Both mass spectrometry instruments provide comparable results and both are sufficient to determine the glycosylation pattern of the five major glycoforms of the measured antibodies. However, the Orbitrap yields higher sensitivity of 25 μg/mL (CE-nanoCEasy-Orbitrap mass spectrometry) and 5 μg/mL (liquid chromatography-Orbitrap mass spectrometry). Data processing was optimized for a faster processing and easier detection of low abundant glycoforms based on averaged charge-deconvoluted mass spectra. This approach combines a non-target glycoform analysis while yielding the same glycosylation pattern as the traditional approach based on extracted ion traces. The presented methods enable the high throughput screening of the glycosylation pattern of antibodies down to low μg/mL-range out of cell supernatant without any sample preparation.  相似文献   

2.
《Electrophoresis》2017,38(9-10):1353-1365
Capillary and microfluidic chip electrophoresis technologies are heavily utilized for development, characterization, release, and stability testing of biopharmaceuticals. Within the biopharmaceutical industry, CE‐SDS and M‐CGE are commonly used for purity determination by separation and quantitation of size‐based variants. M‐CGE is used primarily as an R&D tool for product and process development, while cGMP release and stability testing applications are commonly reserved for CE‐SDS. This paper describes the establishment of an M‐CGE platform method to be used for R&D and cGMP applications, including release and stability testing, for monoclonal antibodies. The M‐CGE platform method enables testing for product development support and cGMP release and stability using the same method, and utilization of one CE technology for the entire lifecycle of a biopharmaceutical product. Critical method parameters were identified, and the analytical design space of those critical parameters was defined using design of experiments (DOE) studies. Once defined through DOE studies, the method design space was validated according to ICH Q2 (R1) guidelines. Additional molecules of the same validated class were verified for use in the method by experimental confirmation of accuracy, specificity, and stability indicating capabilities. The platform method model facilitates rapid utilization of the method in development and GMP testing environments, and eliminates the need for individual validations for assets of the same class entering early stage development.  相似文献   

3.
In this study, we performed high-throughput and precise single nucleotide polymorphism (SNP) typing by fluorescent capillary electrophoresis single-strand conformation polymorphism (CE-SSCP) analysis. A system composed of a multicapillary DNA analyzer, a newly developed sieving matrix, four different colors of fluorescent labels, and a multiplex polymerase chain reaction (PCR) enabled low-cost and highly reliable SNP typing. Moreover, this system enabled the estimation of SNP allele frequencies using pooled DNA samples, which should be beneficial for large-scale association studies. Thus, fluorescent CE-SSCP analysis is a useful method for large-scale SNP typing.  相似文献   

4.
陈泓序  屈锋 《色谱》2018,36(3):195-208
单克隆抗体药物在生物制药行业占有重要地位,是生物医药领域发展的主要方向。因此,单克隆抗体药物的质量控制已成为全球生物制药企业及法规机构关注的热点,对单克隆抗体药物精确表征的需求日益增加。毛细管电泳技术具有分离效率高、分析速度快、分离模式多、样品用量少等特点,已成为单克隆抗体药物分析和质量控制的重要手段。该文对毛细管凝胶电泳、毛细管等电聚焦、毛细管区带电泳等模式在单克隆抗体药物的纯度分析、等电点测定、电荷异质性分析和N-寡糖分析的应用进行综述,以期为国内单克隆抗体研究开发和生产的企事业单位提供技术参考。  相似文献   

5.
We have developed a novel, high-throughput approach for molecular mass determination of proteins from 14 200 to 116 000 based upon multiplexed, absorbance-based capillary electrophoresis. Via capillary multiplexing, 96 samples were analyzed simultaneously within 30 min. Detection with ultraviolet light obviates the need for protein staining or derivatization. The detection limit of the system was estimated at 5 microg/ml bovine serum albumin (BSA) when sampled from 12.5 mM Tris-HCl. The linear dynamic range was over two orders of magnitude from 5 microg/ml to 1000 microg/ml for BSA. Better than 5% sizing accuracy for protein molecular mass determination and excellent run-to-run and day-to-day reproducibility was obtainable with the described method.  相似文献   

6.
High-throughput analysis of telomerase by capillary electrophoresis   总被引:2,自引:0,他引:2  
The enzyme telomerase is expressed in (85-90)% of all human cancers, but not in normal, non-stem cell somatic tissues. Clinical assays for telomerase in easily obtained body fluids would have great utility as noninvasive, cost-effective methods for the early detection of cancer. The most commonly used method for the detection and quantification of telomerase enzyme activity is the polymerase chain reaction (PCR)-based assay known as the telomerase repeat amplification protocol or TRAP assay. Most of the TRAP assay systems use a slab-gel based electrophoresis system to size and quantify the PCR-amplified extension products. We are developing high-throughput capillary electrophoresis (CE) methods for the analysis of TRAP/PCR products. The TRAP assay was conducted on lysates of the human lung cancer cell line A-549 in reactions containing 5-100 cells. TRAP/PCR products were generated using a fluorescent 4,7,2'4'5'7',-hexachloro-6-carboxyfluorescein(HEX)-labeled TS primer and analyzed on the Applied Biosystems Model 310 CE system using POP4 polymer. After analysis with GeneScan and Genotyper software, the total peak areas of the TRAP ladder extension products were computed using Microsoft Excel. Results were compared with unlabeled TRAP/PCR products analyzed on the Bio-Rad BioFocus 3000 CE system using 6% high molecular weight polyvinylpyrrolidone (HMW PVP) polymer and SYBR Green I dye. Both CE systems were able to resolve the TRAP ladder products with high reproducibility and sensitivity (5-15 cells). With the appropriate robotic sample handling system, these CE methods would enable performing the telomerase TRAP assay with increased sensitivity, reproducibility and automation over slab-gel methods.  相似文献   

7.
8.
Sodium dodecyl sulfate capillary gel electrophoresis has been used to separate and quantify murine monoclonal antibodies. The method uses a murine IgG, whose subclass differs from the analyte antibody, as an internal reference. The internal reference is chosen based on knowing that mouse IgG1 can be separated from mouse IgG2a or IgG2b. Good intra- and inter-day reproducibility [relative standard deviation (RSD)<2%] of peak-area ratio has been obtained. A calibration curve also demonstrates high linearity (R2=0.9999) of response for the analyte. The described method is highly suitable for accurate determination of the antibody concentration even if a capillary electrophoresis apparatus is unable to provide good injection reproducibility.  相似文献   

9.
Ventzki R  Stegemann J 《Electrophoresis》2003,24(24):4153-4160
We report a novel separation method that is applicable to both DNA and protein samples, based on electrophoresis in a three-dimensional (3-D) geometry. In contrast to conventional electrophoresis, samples are applied in a two-dimensional, planar array to one of the surfaces of a 3-D geometry separation medium. Loading onto a plane results in a very high sample capacity. Sample migration and separation occur along the third spatial dimension, which is perpendicular to the loading plane. The key problem of electrophoresis in a 3-D geometry separation setup is that temperature gradients are caused by Joule's heat, affecting the electrical conductivity and viscosity of the separation medium. A means of achieving straight sample migration under these circumstances is to force heat flow through the separation medium parallel to the axis of sample migration. This can be done by dissipating the heat via the electrode sides of the gel and blocking any other heat transfer. The separation of DNA and proteins by this method has been tested using agarose gel electrophoresis, polyacrylamide gel electrophoresis, and sodium dodecyl sulfate-polyacrylamide gel electrophoresis. Data were acquired off-line by conventional staining methods as well as on-line by detection of laser-induced fluorescence. We describe how to excise samples from the separation medium for preparative purposes. Possible unique applications of this 3-D geometry electrophoresis separation method are also discussed.  相似文献   

10.
Analytical platforms that characterize charge heterogeneity in therapeutic proteins, such as mAbs, are important tools that can be used to define quality attributes. CZE separates protein moieties close to their native state and is a valuable physicochemical analytical method that can be used in parallel with other orthogonal methods for characterization and comparability. In this study, custom conditions for the analysis of charge heterogeneity of two mAbs were developed with regard to critical parameters in the BGE, running conditions, and sample treatment. The method application was tested for up to four mAbs and one mAb fragment. The electropherograms showed specific profiles and contrasting levels of basic and acidic isoforms with respect to the main isoform. Issues that surround this method, such as peak tailing and capillary lifetime, are summarized. Using this method, the identities of rituximab and trastuzumab were confirmed, based on the correspondence between the biosimilars and reference products, noninterference of the sample matrix, and the ability to separate spiked samples of related mAbs. The RSD of the isoform content and migration time for the method repeatability were less than 2 and 1%, respectively.  相似文献   

11.
Sugawa S  Kawano T  Nara Y  Isomura T 《Electrophoresis》2006,27(7):1300-1302
The automation of SDS-PAGE required substantial investment. To lower this barrier, we devised a cost-effective, simple, and general method where samples are loaded on SDS-PAGE gels held by a newly devised "Gel Adaptor" on a general automated liquid handler. In this method, the liquid handler loads samples on the SDS-PAGE gels held at an angle of 80 degrees on the Gel Adaptor so that the samples can be vertically loaded on the narrow paths of the wells of the slanted gels. This method allows the automated liquid handler to load 144 samples on SDS-PAGE gels in approximately 10 min, greatly reducing the time and cost for high-throughput SDS-PAGE analyses.  相似文献   

12.
Ultrathin-layer agarose gel electrophoresis is a novel combination of the established methodologies of slab gel electrophoresis and capillary gel electrophoresis. This new format provides a multilane separation platform with rapid analysis time and excellent sensitivity by using laser-induced fluorescence scanning detection system. Sample injection onto the ultrathin-layer separation platform is easily accomplished by membrane mediated loading technology. In this paper, we demonstrate the sensitivity and high-throughput fashion of this novel separation and detection system for rapid genotyping of the coagulation factor V Leiden mutation by polymerase chain reaction (PCR)-restriction fragment length polymorphism (RFLP) analysis. The PCR amplified fragment from exon 10 of the factor V gene was digested by the Mnl I restriction enzyme, followed by automated ultrathin-layer agarose gel electrophoresis analysis with "in migratio" fluorescent labeling during the separation process. Due to its speed and automation, this method should be considered for large scale screening of factor V Leiden mutation.  相似文献   

13.
《Electrophoresis》2017,38(3-4):401-407
Four methods were compared for analysis of host‐cell protein (HCP) impurities in a recombinant mAb. First, CZE‐MS/MS was used to analyze the digest of an HCP sample following extraction of the mAb with proteins A and L affinity columns; 220 protein groups and 976 peptides were identified from the depleted HCP digest. Second, a nanoACQUITY UltraPerformance LCH system was also used to analyze the depleted HCP digest; 34 protein groups and 53 peptides from 50 ng of the depleted HCP digest and 290 protein groups and 1011 peptides were identified from 1 μg of the depleted HCP digest. Third, 185 protein groups and 709 peptides were identified by CZE‐MS/MS from the HCP digest without depletion. Fourth, a strong cation exchange SPE was coupled to CZE‐ESI‐MS/MS using online pH gradient elution for analysis of the HCP digest without depletion. A series of five pH bumps were applied to elute peptides from the strong cation exchange monolith followed by analysis using CZE coupled to a Q Exactive HF mass spectrometer; 230 protein groups and 796 peptides were identified from the HCP digest without depletion.  相似文献   

14.
15.
de Jong EP  Melanson JE  Lucy CA 《Electrophoresis》2004,25(18-19):3153-3162
Traditional protein labeling reactions for capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection suffer from a variety of disadvantages. The reactions can be nonquantitative on a reasonable time scale, require relatively high concentrations of protein and fluorophore, and can give multiple reaction products that can not be separated. Herein, we describe a new noncovalent labeling technique that is rapid, selective for myoglobin, and gives a simple reaction product. Myoglobin is denatured with either 5.4 M urea or low pH (2.0). The denatured myoglobin releases its nonfluorescent heme group. A fluorescent porphyrin (protoporphyrin IX (PPIX) or its zinc (II) complex, Zn-PPIX), is added to the mixture and the solution conditions are altered (dilute to 0.54 M urea or adjust pH to 7.0) to allow myoglobin refolding. Upon refolding, the protein incorporates PPIX from solution, thus making the reaction product fluorescent. The experimental conditions have been optimized for both urea and low-pH denaturation of myoglobin. The latter procedure produces a detection limit of 50 nM. Alternatively, the reaction can be performed without denaturation by a simple exchange of the porphyrins. The use of Zn-PPIX yields the most efficient reaction. The low-pH reaction is unaffected by a 2000-fold excess of bovine serum albumin.  相似文献   

16.
Total N-linked oligosaccharide profiling method for recombinant monoclonal antibody (rmAb) using capillary electrophoresis with laser-induced fluorescence detection (CE-LIF) and an approach for detailed structural analysis of N-linked oligosaccharide were developed. A CE-LIF method using 2-aminobenzoic acid (2-AA) as a fluorogenic reagent allowed sensitive detection of several minor peaks besides typical asialo-biantennary complex type oligosaccharides in the analysis of N-linked oligosaccharide from a commercial rmAb pharmaceutical, rituximab. These minor peaks were successfully assigned as sialo-biantennary complex type and high-mannose type oligosaccharides by comparison with the migration times of 2-AA derivatized oligosaccharides which were separately fractionated and determined by high-performance liquid chromatography (HPLC) and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). In development of biopharmaceuticals, it is important to evaluate these minor oligosaccharides, because some of these minor glycans are likely to influence immunogenicity and clearance rate in vivo. The repetitive analysis using CE-LIF showed excellent precision in relative corrected peak areas. These results demonstrate that the present CE-LIF method is applicable for both structural characterization and quantitative profiling of N-linked oligosaccharides derived from rmAb pharmaceuticals. The present method will be a powerful tool for rapid, quantitative and exhaustive evaluation of N-linked oligosaccharides in various stages of rmAb pharmaceutical development such as clone selection, bioprocess control, and routine lot release testing to ensure product efficacy and consistency.  相似文献   

17.
丛宇婷  胡良海 《色谱》2016,34(12):1186-1191
单克隆抗体药物是一类以免疫球蛋白G的结构为基础的大分子糖蛋白药物,为癌症、自身免疫疾病以及病毒感染等多种疾病的治疗提供了全新的途径。单抗药物的糖基化修饰类型及水平对其稳定性、清除率、免疫原性、抗体依赖细胞毒性及补体依赖细胞毒性等都有一定的影响。单抗药物的迅速发展及其在多种疾病治疗中日益凸显的重要性都对单抗药物的研发及用药安全等方面提出了更高的要求。因此,建立规范可靠的单抗药物糖基化修饰分析方法有着十分重要的意义。该综述将简要介绍单克隆抗体药物糖基化修饰及相关的定性、定量分析方法。  相似文献   

18.
D Wheeler  D Tietz  A Chrambach 《Electrophoresis》1992,13(9-10):604-608
Abnormally slow migration of DNA is conventionally viewed as being due to an abnormal conformation relative to "linear" standards. The evidence for this rests on a few instances where nonlinear DNA structures have been established by independent methods and yield low mobilities relative to standards. Transverse pore gradient gel electrophoresis of authentically bent kinetoplast DNA and of an upstream activator sequence (UAS) of an E. coli operon promoter shows in addition that curves of migration distance vs. gel concentration ("Ferguson curves") of such abnormally conformed DNA differ from those of "linear" standards. Since Ferguson curves are interpretable with regard to molecular size in concordance with a mathematical model (Ogston model), transverse pore gradient gel electrophoresis provides a simple means of correlating abnormally slow migration of DNA with molecular size. In addition, transverse pore gradient gel electrophoresis is able to distinguish between DNA banding which exhibits a steeper dependence on gel concentration than "linear" standards from one which shows the same dependence. The former appears characteristic of circularly bent DNA and gives rise to a substantial retardation, the latter of bending across a knot or kink in the DNA chain associated with a relatively minor retardation relative to standards. Circularly bent restriction fragments formed from kinetoplast DNA retain the characteristic intersecting Ferguson curves on the transverse pore gradient gel. Another authentically "abnormal" DNA structure recognizable on transverse pore gradient gels is supercoiled DNA derived from the reaction of topoisomerase with a plasmid. Different lengths of supercoiled sequences give rise to parallel Ferguson curves clearly intersecting with those of linear standards.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

19.
Zhang Y  He Y  Yeung ES 《Electrophoresis》2001,22(11):2296-2302
Routine genetic analysis of large numbers of individuals by polymerase chain reaction (PCR) using capillary electrophoresis is often restricted by the low throughput of standard protocols and the tedious sample preparation process. Here, we demonstrate that capillary electrophoresis with UV detection can be used in PCR-based DNA analysis starting from clinical samples without purification or complicated sample manipulation. After PCR reaction using cheek cells, blood, or HIV-1 gag DNA, the reaction mixtures were injected into a capillary array either on-line or off-line by base stacking. The use of multiplexed absorption detection and the elimination of any purification steps both before and after PCR reaction can potentially provide significant benefits compared to current methods for DNA analysis with regard to time, cost, and labor.  相似文献   

20.
A capillary zone electrophoresis (CZE) method was developed for the rapid analysis of charge heterogeneity of immunoglobulin G (IgG) monoclonal antibodies (mAbs). The separation was carried out in a short, dynamically coated fused-silica capillary. A number of separation parameters were investigated and optimized, including pH, concentration of the separation buffer (ε-amino caproic acid), concentration of the triethylenetetramine (TETA) dynamic coating, the capillary internal diameter and the field strength used for the separation. The effects of between-run flushing of the capillary and the data acquisition rate were also evaluated. Under the optimized conditions, a fast (<5 min), selective and reproducible separation of mAb charge variants was achieved under a very high electric field strength (1000 V/cm). This method also requires only a short conditioning of the capillary, with between-run conditioning completed within 2 min. The method was evaluated for specificity, sensitivity, linearity, accuracy and precision. The same separation conditions were applied to the rapid separation (2-5 min) of charge variants of multiple monoclonal antibodies with pI in the range of 7.0-9.5. Compared with other existing methods for charge variants analysis, this method has several advantages including a short run time, rapid capillary conditioning and simple sample preparation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号